HomeMy WebLinkAboutBuilding Miscellaneous 2007-8-14 CertainTeed II Builders Statement Homeowner Name / Jobsite Name , Jl4C\ S. 40~ (:-t Home Address _ f \<'.QO\~ S. L,.\-Q(L{ Installer I Contractor (sign) Builder (sign) Inspected By (sign if required) OPEN ATTIC APPLICATION R-YALUE To obtain a thermal resistance (R)el: 60 49. 44 38 30 26 22 19 13 11 CEILINGS WALLS FLOORS MINIMUM BAGS PER 1000 SQ. FT. Bags per 1000 sq. ft. 01 net area: 31.4 252 22.4 19.1 14.9 12.8 10.8 9.3 6.2 5.3 A-VALUE 3R . ~ C ,- Vz...-z-. u~~' 'InsuISafe@ SP Fiber Glass Blowing Insulation" ". - ~. \~<'0\~\J~ Company Name MAXIMUM NET sa. rr. PER BAG COVERAGE Conlanls of bag shall notcov8r morelhan: (sq. ft.) 31.9 39.7 44.6 52.5 67.1 77.9 92.9 107.4 161.7 190.5 9, - ~4 .C17 L:late , Company Name Date Date MINIMUM WEIGHT-, POUNDS PER SQ. FT. Weighl per sq. ft of inslalled insulation shall not be less than: (Ibs.) 0.972 0.780 0.695 0.591 0.462 0.398 0.334 0.289 0.192 0.163 MINIMUM INSTALLED THICKNESS Installed insulation shall not be less than: (in.) 22.00 16.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 ..r- / I '-^ MINIMUM SETTLED THICKNESS Minimum setlled insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10,25 8.75 7.75 5.25 4.50 BATTSIROLLS (.....) <~ THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must install the minimum number of,bags per 1,000 sq. h. of net area for each R.Value listed. The maximum net coverage must not exceed that specified for each R-Value. . The insulation must be installed at or above the specified installed thickness for each R.Value. . Failure to install the required minimum weight per sq. h. of insulation at or ab'ove the initial installed thickness will result in reduced R,Value. . This product should not be mixed with other blown insulations or the thermal claims will become invalid. -- .. I 1.\ . t:.)() I NET AREA (SO. FT.) I\~OO I '3,f'1 THICKNESS "\~ :r~;"f .,- INSU~SAFE SP ~ ./" BAGS USED DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO:NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES, THIS WARNING DOES NOT APPLY TO TYPE IC ~IGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. @2007 CertainTeed Corporation .... , A Saint-Gobain Company:. " 30-24-298 Builders Statement 2/07 . ....., .' , . ". ..) ~ Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@ SP Fiber Glass Blowing Insulation CertainTeed. CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 COVERAGE'CHART-OPEN ATTIC APPLICATION The follo~ing thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. ~ " MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM A-VALUE BAGS PEA 1000 SQ. FT. PEA BAG COVERAGE POUNDS PER SQ. fT. INSTA.L.L.ED THICKNESS SETTLED 'THICKNESS To obtain a Bags per Contents of bag Weight per sq. ft. of Installed insulation Minimum settled insulation thermal resistance 1000 sq. ft. shall nolcover installed insulation shall shall rlol be less than: shall nolbe lesslhan: (R) of: of net area: more than: (sQ. ft.) not be lesslhan: (lbS.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 10.75 t6.75 38 19.1 52,5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3 .' -'---' REQUIRED OR MINIMUM MAXIMUM NET sa, FT. MINIMUM WEIGHT- INSTALLED R.VAlUE BAGS PER 1000 sa. FT. PEA BAG COVERAGE POUNDS PER SQ. FT. THICKNESS To obtain a Bags per Contents of bag Weight per sq. ft. of InslaJledinsuiation thermal resistance 1000 sq. ft. shall not cover installed insulation shall shall not be less than: (R)of: of net area: rnorethan: (sa. ft,) nol be less than: (Ibs.) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0.533 4.00 15 16.1 62,0 0.500 3.75 14. 15.1 66.4 0.467 3.50 _/" READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow The higher the R-Value, the greater the insulating power Compare insulation R-Values before you buy. There are other factors to consider The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, ttJe type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. (92007 CertaillTeed Corporation A Saint-Gobain Company 30-24-298 Manufacturer Fact Insulation Sheet 2107