Loading...
HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2008-9-17 l ~~;lInformation ,.,~. .To Build On Engineering . Consulting. Testing DAILY FIELD REPORT Date Performed: September 17, 2008 Report Number: 722-80177-27 Client: John Saraceno Project NamEi': A3- Academy of Arts & Springfield School District Academics ,. -:....----. -.... 525 Mill Street Project Location: 615 Main Street._ Springfieid, OR 97477 Springfield, Orego~ B.P, No,:, Shop/Field: Shop Type of Inspection: Welding Weather: Clear Field Observations and Comments Performed continuous visual inspection of the following items: Root pass on store front radius 1 st to 5th column and 6th to 9th column to beam connections lower attachment. Final welds will be inspected at a later date, In-progress weiding was monitored to the erectors FCAW welding procedure specifications, Weidments were inspected for size, length, profile and locations, To the best of our knowledge;.the work inspected is in conformance with approved drawings, . specifications and applicable D1, 1 codes, Contractor was asked to notify our office when .additionai services,are needed, Inspector: David F. Smith certification # 0877340-85 CCB #176269 If you have any questionSTegarding'this report, plea'se feel iree to contact us at 541-746-9649, Respectfully Submitted, ~':1":m-"~ David Smith Branch'Manager .~~- ... 0{j;~ .. . 'zj-;l '[~. ~/,',: c . ..J, . _'" "r . (' .. . c: City of Springfield Lee Construction Branch Engineering Solarc Architecture Professional Underground Service THIS REPORT IS PROVIDED FOR THE INFC!RMA rlON OF THE CLIENT. ONL y, THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND fTS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOIJT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBfTED. Professional Service Ind~strie5, Inc.. 1040A Shell~ .Sf.. Springfield, OR 97477. Phone 5411746.9649. Fax 5411746-7163 l"'~;1 Information I"0ii7. .To Build On Engineering . Consulting . Testing Date Performed: Client: September 19, 2008 Lee Construction PO, Box 10367 Eugene, OR 97401 P.Q, No.: Type of Structure: Type of Inspection: CMU Wall Structural Masonry DAILY FIELD REPORT Report Number: 722-80177-28 Project Name: A3 Building Project Location: 615 Main Street, Springfield OR Permit No.: Weather: partiy cloudy Field Observations and Comments Performed visual inspection of reinforcing steel at the following locations: CMU walls: Trash enclosure from 8' to 12'. Interior walls at room's 111A, 112A from F,F to 3' 4", north wallfrom F,F to 3' 4", Reinforcing steel was inspected for size, grade, lap, placement, and clearances where applicable, Reinforcing steel was placed in accordance with the approved design drawings and specifications, All cells were relatively clean and mortar projections are within the limits of the Uniform Building Code, Grout was placed by pump and mechanically consolidated, Only cells containing reinforcing steel were grouted solid, Empty cells were covered with grout paper to be insulated later. NOTE: Interior walls and exterior 0 and N wall were grouted solid, To the best of our knowledge, the work inspected above was in accordance with the building department. approved design drawings, specifications and applicable workmanship provisions of the International Building Code, Contractor was advised of all on-site results and asked to notify our office when additional services are needed, Tvoe of Material Supplier Mix# Slump Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) Numbe'r of Samples Total Yardaoe Placed Inspector: Steven Wilder - ICC# 0874615-84 CCB #176269 Gr2llt Knife River 247HG3R100 10" N/A 72 74 1:30PM 2000 req, n/a 5 vds, 3000 placed If you have any questions regarding this report, please feel free to contact us at 541-746-9649, , , Respectfully Submitted, Professional Se Ice Industries; Ine, .I)~\f, David Smith Branch Manager C: City of Springfield Branch Engineering Solarc Architecture Professional Underground Service Springfield School District - John Saraceno THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT aNL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PAR__F8l!P,,~R6jjS\t~4&/~oW~H/!l(ey'lllr'I!<!F"'~~Iili1lfil!jlf.'l9Fm~~IlLPIi&Y~t{I7~~T_ "I<l\l'!l4'mlf~'7163 L"~;lInformation ",~. .To Build On Engineering . Consulting . Testing DAILY FIELD REPORT Date Performed: September 10, 2008 Report Number: 722-80177-21 Client: John Saraceno Project Name: A3 - Academy of Arts & Springfield School District Academics 525 Mill Street Project Location: 615 Main Street Springfield, OR 97477 Springfield, Oregon B.P. No.: Shop/Field: Shop Type of Inspection: Weiding Weather: Clear. ~ Field Observations and Comments Performed continuous visual, inspection of the following items: Partial-pene welds on column 4C, K to H attachment. Fit- up of weld joints were inspected for workmanship, In-progress welding was monitored to the fabricators FCAW welding procedure specifications, Weldments were inspected for size, length, profile and locations, To the best of our knowledge, the work inspected is in conformance with attached drawings, specifications and applicable.D1, 1 codes, The , following item's were not in conformance: No approved drawing, Engineering approval detail to follow, Fabricator. was ' asked to notify our office when additional services are needed, . Inspector: David F. Smith certification # 0877340-85 CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649, Respectfully Submitted, D~.srJr~"" David Smith Branch Manager c: City of Springfield Lee Construction Branch .Engineering Solarc Architecture Professional Underground Service I\>~c Of; ~/J/L'- -l $ '0, 1.?.?Q' THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THfRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. . , Professional Service Industries, Inc.. 1Q40A Shelley St.. Springfield, OR 97477. Phone 541/746--9649. Fax 5411746-7163 -- l ~~;lInfonnation ",~. .To Build On Engineering. Consulting . Testing . DAILY FIELD REPORT Date Performed: Client: August29,2008 John Saraceno Springfield School District 525 Mill Street Springfield, OR 97477 Report Number: 722-80177-16 A3 - Academy of Arts & Academics 615 Main Street Springfield, Oregon Project Name: Project Location: B,P, No.: Type of Inspection: Welding Weather: Overcast Field Observations and Comments Performed continuous visual inspection on partial penetration grove and multi pass fillet welds on TUBE steel column 4C, (4) 8B and (3) 8A. Also inspected TUBE steel and channel deck supports 6H, 6C, 70, 7B, 7A. 7F, 9K, 9H, (2)9F, Tube steel columns BH, 9A, 9B, 90, 9C, 3D, (4) 5B, 5C,5A, 3C, 4A, 4B, 2B and 2C,' Welding was'performed by (1). certified welder Matt Roper #8668 using FCAW process with E71T -1 wire, Fit-up of weld joints were inspected for workmanship, In-progress welding was monitored to the fabricator's weiding procedure specifications, Weldments were inspected for size,. length, profile and locations, To the best of our knowledge, the work inspected is in conformance with ap[>roved drawinQs, specifications and applicable 01,1 codes, Inspector: Curt H.alstead CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649, Respectfuliy Submitted, Professional Service Industries, Inc. 1l~ s ~ Branch Manager c: City of Springfield Lee Construction Branch Engineering Sol arc Architecture Professional Underground Service THIS REPORT 1$ PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT. BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PI.RTV ,:rY lJ.NYU;;.lJ.N,<:'; FXr:FPT IN FULL WITHOUT TJ../F WRITTEN P~RMJSSION OF PROFESSIONAL SERVICE INDUSTRIES. IS PROHIBITED. Professional Service Industries, Inc.. 1040-A Shetley Street. Springfield, OR 97477. Phone 541/746-9649. Fax 541(746.7163 L "~;l Information ,.,..,. .To Build On Engineering. Consulting . Testing DAILY FIELD REPORT Date Performed: August 25, 2008 Report Number: 722-80177-14 Client: John Saraceno Project Name: A3 - Academy of Arts & Springfield School District Academics 525 Mill Street Project Location: 615 Main Street Springfield, OR 97477 Springfield, Oregon B.P, No,: Shop/Field: Field Type of Inspection: Welding Weather: Partly cloudy Field Observations and Comments Performed periodic visual inspection of the following items: Performed reinspectionof single pass fillet welds on tube steel column 46, REF 7,1 (C) ASI #21, welding in acceptable. Weldments were inspected for size, length, profile and locations. To the best of our knowledge, the work inspected is in conformance with approved drawings, specifications and 'applicable D1, 1 codes, Inspector: Curt Halstead ICC# 1060568-85 CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfuliy Submitted, Professional serv(e ~ries, Inc. ~('- David Smith Branch Manager c: City of Springfield Lee Construction Branch Engineering Solarc Architecture Professional Underground Service THIS REPORT IS PROVIDED FOR THE INF=ORMATIQN OF THE CLIENT QNL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, Inc. . 1040-A Shelley Street. Springfield, OR 97477 . Phone 541/746-9649 . Fax 541/746-7163