HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2008-9-17
l ~~;lInformation
,.,~. .To Build On
Engineering . Consulting. Testing
DAILY FIELD REPORT
Date Performed: September 17, 2008 Report Number: 722-80177-27
Client: John Saraceno Project NamEi': A3- Academy of Arts &
Springfield School District Academics
,. -:....----. -....
525 Mill Street Project Location: 615 Main Street._
Springfieid, OR 97477 Springfield, Orego~
B.P, No,:, Shop/Field: Shop
Type of Inspection: Welding Weather: Clear
Field Observations and Comments
Performed continuous visual inspection of the following items: Root pass on store front radius 1 st to 5th column and 6th
to 9th column to beam connections lower attachment. Final welds will be inspected at a later date, In-progress weiding
was monitored to the erectors FCAW welding procedure specifications, Weidments were inspected for size, length,
profile and locations, To the best of our knowledge;.the work inspected is in conformance with approved drawings, .
specifications and applicable D1, 1 codes, Contractor was asked to notify our office when .additionai services,are
needed,
Inspector: David F. Smith certification # 0877340-85
CCB #176269
If you have any questionSTegarding'this report, plea'se feel iree to contact us at 541-746-9649,
Respectfully Submitted,
~':1":m-"~
David Smith
Branch'Manager
.~~-
... 0{j;~ ..
. 'zj-;l
'[~. ~/,',: c .
..J, . _'" "r .
(' .. .
c: City of Springfield
Lee Construction
Branch Engineering
Solarc Architecture
Professional Underground Service
THIS REPORT IS PROVIDED FOR THE INFC!RMA rlON OF THE CLIENT. ONL y, THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND fTS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOIJT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBfTED.
Professional Service Ind~strie5, Inc.. 1040A Shell~ .Sf.. Springfield, OR 97477. Phone 5411746.9649. Fax 5411746-7163
l"'~;1 Information
I"0ii7. .To Build On
Engineering . Consulting . Testing
Date Performed:
Client:
September 19, 2008
Lee Construction
PO, Box 10367
Eugene, OR 97401
P.Q, No.:
Type of Structure:
Type of Inspection:
CMU Wall
Structural Masonry
DAILY FIELD REPORT
Report Number:
722-80177-28
Project Name:
A3 Building
Project Location:
615 Main Street, Springfield OR
Permit No.:
Weather:
partiy cloudy
Field Observations and Comments
Performed visual inspection of reinforcing steel at the following locations: CMU walls: Trash enclosure from 8' to 12'.
Interior walls at room's 111A, 112A from F,F to 3' 4", north wallfrom F,F to 3' 4", Reinforcing steel was inspected for
size, grade, lap, placement, and clearances where applicable, Reinforcing steel was placed in accordance with the
approved design drawings and specifications, All cells were relatively clean and mortar projections are within the
limits of the Uniform Building Code, Grout was placed by pump and mechanically consolidated, Only cells containing
reinforcing steel were grouted solid, Empty cells were covered with grout paper to be insulated later. NOTE: Interior
walls and exterior 0 and N wall were grouted solid, To the best of our knowledge, the work inspected above was in
accordance with the building department. approved design drawings, specifications and applicable workmanship
provisions of the International Building Code, Contractor was advised of all on-site results and asked to notify our
office when additional services are needed,
Tvoe of Material
Supplier
Mix#
Slump
Air Content
Ambient Temperature
Material Temperature
Time Placed
Design Strength (psi)
Numbe'r of Samples
Total Yardaoe Placed
Inspector: Steven Wilder - ICC# 0874615-84
CCB #176269
Gr2llt
Knife River
247HG3R100
10"
N/A
72
74
1:30PM
2000 req,
n/a
5 vds,
3000 placed
If you have any questions regarding this report, please feel free to contact us at 541-746-9649,
, ,
Respectfully Submitted,
Professional Se Ice Industries; Ine,
.I)~\f,
David Smith
Branch Manager
C: City of Springfield
Branch Engineering
Solarc Architecture
Professional Underground Service
Springfield School District - John Saraceno
THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT aNL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PAR__F8l!P,,~R6jjS\t~4&/~oW~H/!l(ey'lllr'I!<!F"'~~Iili1lfil!jlf.'l9Fm~~IlLPIi&Y~t{I7~~T_ "I<l\l'!l4'mlf~'7163
L"~;lInformation
",~. .To Build On
Engineering . Consulting . Testing
DAILY FIELD REPORT
Date Performed: September 10, 2008 Report Number: 722-80177-21
Client: John Saraceno Project Name: A3 - Academy of Arts &
Springfield School District Academics
525 Mill Street Project Location: 615 Main Street
Springfield, OR 97477 Springfield, Oregon
B.P. No.: Shop/Field: Shop
Type of Inspection: Weiding Weather: Clear.
~
Field Observations and Comments
Performed continuous visual, inspection of the following items: Partial-pene welds on column 4C, K to H attachment. Fit-
up of weld joints were inspected for workmanship, In-progress welding was monitored to the fabricators FCAW welding
procedure specifications, Weldments were inspected for size, length, profile and locations, To the best of our
knowledge, the work inspected is in conformance with attached drawings, specifications and applicable.D1, 1 codes, The
, following item's were not in conformance: No approved drawing, Engineering approval detail to follow, Fabricator. was '
asked to notify our office when additional services are needed,
. Inspector: David F. Smith certification # 0877340-85
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649,
Respectfully Submitted,
D~.srJr~""
David Smith
Branch Manager
c: City of Springfield
Lee Construction
Branch .Engineering
Solarc Architecture
Professional Underground Service
I\>~c
Of; ~/J/L'-
-l $ '0,
1.?.?Q'
THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THfRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED.
. ,
Professional Service Industries, Inc.. 1Q40A Shelley St.. Springfield, OR 97477. Phone 541/746--9649. Fax 5411746-7163
--
l ~~;lInfonnation
",~. .To Build On
Engineering. Consulting . Testing
. DAILY FIELD REPORT
Date Performed:
Client:
August29,2008
John Saraceno
Springfield School District
525 Mill Street
Springfield, OR 97477
Report Number:
722-80177-16
A3 - Academy of Arts &
Academics
615 Main Street
Springfield, Oregon
Project Name:
Project Location:
B,P, No.:
Type of Inspection:
Welding
Weather:
Overcast
Field Observations and Comments
Performed continuous visual inspection on partial penetration grove and multi pass fillet welds on TUBE steel column
4C, (4) 8B and (3) 8A. Also inspected TUBE steel and channel deck supports 6H, 6C, 70, 7B, 7A. 7F, 9K, 9H, (2)9F,
Tube steel columns BH, 9A, 9B, 90, 9C, 3D, (4) 5B, 5C,5A, 3C, 4A, 4B, 2B and 2C,' Welding was'performed by (1).
certified welder Matt Roper #8668 using FCAW process with E71T -1 wire, Fit-up of weld joints were inspected for
workmanship, In-progress welding was monitored to the fabricator's weiding procedure specifications, Weldments were
inspected for size,. length, profile and locations, To the best of our knowledge, the work inspected is in conformance
with ap[>roved drawinQs, specifications and applicable 01,1 codes,
Inspector: Curt H.alstead
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649,
Respectfuliy Submitted,
Professional Service Industries, Inc.
1l~ s ~
Branch Manager
c: City of Springfield
Lee Construction
Branch Engineering
Sol arc Architecture
Professional Underground Service
THIS REPORT 1$ PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT. BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PI.RTV ,:rY lJ.NYU;;.lJ.N,<:'; FXr:FPT IN FULL WITHOUT TJ../F WRITTEN P~RMJSSION OF PROFESSIONAL SERVICE INDUSTRIES. IS PROHIBITED.
Professional Service Industries, Inc.. 1040-A Shetley Street. Springfield, OR 97477. Phone 541/746-9649. Fax 541(746.7163
L "~;l Information
,.,..,. .To Build On
Engineering. Consulting . Testing
DAILY FIELD REPORT
Date Performed: August 25, 2008 Report Number: 722-80177-14
Client: John Saraceno Project Name: A3 - Academy of Arts &
Springfield School District Academics
525 Mill Street Project Location: 615 Main Street
Springfield, OR 97477 Springfield, Oregon
B.P, No,: Shop/Field: Field
Type of Inspection: Welding Weather: Partly cloudy
Field Observations and Comments
Performed periodic visual inspection of the following items: Performed reinspectionof single pass fillet welds on tube
steel column 46, REF 7,1 (C) ASI #21, welding in acceptable. Weldments were inspected for size, length, profile and
locations. To the best of our knowledge, the work inspected is in conformance with approved drawings, specifications
and 'applicable D1, 1 codes,
Inspector: Curt Halstead ICC# 1060568-85
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfuliy Submitted,
Professional serv(e ~ries, Inc.
~('-
David Smith
Branch Manager
c: City of Springfield
Lee Construction
Branch Engineering
Solarc Architecture
Professional Underground Service
THIS REPORT IS PROVIDED FOR THE INF=ORMATIQN OF THE CLIENT QNL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED.
Professional Service Industries, Inc. . 1040-A Shelley Street. Springfield, OR 97477 . Phone 541/746-9649 . Fax 541/746-7163