HomeMy WebLinkAboutPermit Verification 2007-7-25 (2) ~,\ ~ "-\ CertainTeed III Builders Statement \ 1 \ C'J,j\30E,/ I -" I InsulSafe@ SP Fiber Class Blowing Insulation 3;297- .?;Z97 //<;~.,. Sfl Homeowner Name I Jobsite Na~e SJJf,';,q -t','e!c/ O/Z Home;;~ 11IJ- Installer I Contractor (sign) 7 / ;z..s-/ a 7 Builder (sign) Company Name Home Insulation Contractors Inc. 34151i ~\'M 00<= T&~.I'~'9V389 Builders Board II8S oafe , Date Inspected By (sign if required) Date OPEN ATTIC APPLICATION I MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM A-VALUE BAGS PEA 1000 SQ. FT. PER BAG COVERAGE POUNDS PER sa, FT. INSTALLED THICKNESS SEITtED THICKNESS To obtain a Bags per Contenls of bag Weighl per sq. ft. of Inslalledinsulation Minimum settled insulation thermal resistance 1000 sq. ft. shall nclcove installed insulation shall shall nol be less than: shall nalba less than: (Rlol: of net area: more than: (s~ not be less than: (Ibs.) (in.) (in.) 60 31.4 31.9 0.972 I 22.00 22.00 49 25.2 '39.7 0.780 I 18.50 18.50 44 22.4 44.6 0.695 I 16.75 .16.75:- ~>> 19.1 52.5 0.591 I 14.50 \. 14.50'\ 30 14.9 67.1 0.462 .J 11.75 11:75..... 26 12.8 77.9 0.398 10.25 10.25 22 ---1-- , 10.8 92.9 0.334 ,I 8.75 8.75 19 I 9.3 107.4 0.289 7.75 7.75 13 I 6.2 161.7 0.192 /1 5.25 5.25 11 I 5.3 190.5 0.163 'I 4.50 4.50 -..' -. ,:;'." THICKNESS NET .AREA (Sa. FT.) INSULSAFE SP (V) BAGS USED BATTSlAOLLS (V) A.VALUE CEILINGS WALLS FLOOAS THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R-Value listed. . The maximum net coverage must not exceed that specified for each R-Value. . The insulation must be installed at or above the specified installed thickness for each R-Value. . Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R-Value. . This product should not be mixed with olher blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. C2007 CertainTeed Corporation A Saint-Gobain Company 30,24.298 Builders Statement 2107 "" Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@ SP Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 CertainTeed 1:-1 COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. MINIMUM WEIGHT- POUNDS PER sa. FT. Weight per sq. ft. 01 installed insulation shall not be less than: (Ibs.) 0.972 0.780 0.695 0.591 0.462 0.398 0.334 .... ., . ",.,.#'.,..: . .J "... '.->-<~. R-Values are determined in accordance with ASTM C687 and- CS18. Complies with ASTM C764 as Type 1 Application. R-VALUE MINIMUM BAGS PER 1000 sa. FT. To obtain a thermal resistance (R}of: 6() 49 44 38 30 26 22 19 13 11./ Bags per 1000 sq. fl. of net area: 31.4 25.2 22.4 19.1. 14.9 12.8 10.8 9.3 6.2 5.3 MAXIMUM NET sa. FT. PER BAG COVERAGE Contents of bag . shall not cover more than: (sq. fl.) 31.9 39.7 44.6 52.5 67.1 77.9 92.9 107.4 161.7 '190.5 ,- MINIMUM INSTALLED THICKNESS Installed insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 MINIMUM SETTLED THICKNESS Minimum sellled insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 pneumatic Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; lS-inch gate opening; lS0 ft. x 4-inch diameter internally corrugated bl6:;Jng hose. . COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/2S.6 Kg/m'. REaUIRED OR MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- INSTALLED A-VALUE BAGS PER 1000 sa. FT. PEA BAG COVERAGE POUNDS PEA sa. FT. THICKNESS Tooblain a Bags per Contents of bag Weighl per sq. fl. of Installed insulation thermal resistance 1000 sq. ft. shall not cover installed insulation shall shall nol be less than: fR) of: 01 net area: more than: (sq. ft.) nol be less than: (Ibs.) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0.533 4.00 15 16.1 62.0 0.500 3.75 14 15.1 66.4 0,467 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. @2007 CertainTeed Corporation A Saint-Gobain Company 30-24.298 Manufacturer Fact Insulation Sheet 2/07