OPEN ATTIC APPLICATION
R-VALUE
To obtain a
thermal resistance
(R}al:
60
49
44
38
30
26
22
19
13
11
I MINIMUM
BAGS PER 1000 SQ. FT.
Bags per
1000 sq. ft.
al nel area:
31.4
25.2
22.4
19.1
14.9
12.8
10.8
93
6.2
53
tl- \~VA
InsulSafe@ SP
Fiber Class Blowing Insulation
f(~h'r In\. v L, td'l (!{)
Company Name
MAXIMUM NET SQ. FT.
PER BAG COVERAGE
Contents of bag
shall naleover
more than: (sQ. ft.)
31.9
39.7
44.6
52.5
67.1
77.9
92.9
107.4
161.7
190.5
Company Name
MINIMUM WEIGHT-
POUNDS PER sa. FT.
Weight per sq. ft. of
installed insulation shall
not be lesslhan: (Ibs.)
0.972
0.780
0.695
0.591
0.462
0.398
0.334
0.289
0,192
0.163
/ - f7-0A
Date
Date
Date
MINIMUM
INSTALLED THICKNESS
Installed insulation
shall not be less than:
(in,)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50
MINIMUM
SETTLED THICKNESS
Minimumsellledinsulalion
shall not be less than:
/in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4,50
/
R-VALUE THICKNESS NET AREA (SQ. FT.) INSULSA'1> I BAGS USED BATTSlROLLS (v)
..JB /4 If L i.J. Lj 0 I 75
CEILINGS
WALLS /
,;t( 6zo
FLOORS
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. In accordance with the chart above, you must instali the minimum number of bags per 1,000 sq. ft. of net area for each
R-Value listed.
. The maximum-net coverage must not exceed that specified for each A-Vaiue.
. The insulation must be instalied at or above the specified instalied thickness for each A-Value.
. Failure to instali the required minimum weight per sq. ft. of insuiation at or above the initial installed thickness wili result in
reduced A-Value.
. This product should not be mixed with other biown insulations or the thermal claims wili become invalid.
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS.
@2007 CertainTeed Corporation
....
A Saint-Gobain Company
30-24-298 Builders Statement 2107
,....
,-
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Glass Blowing Insulation
CertainTeed II'
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow application.
MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
R-VALUE BAGS PER 1000 sa. n. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS
To obtain a Bags per Contents of bag Weight per sq. ft. of Installed insulation Minimum settled insulation
thennal resistance 1000 sq. ft. shall not cover installed insulation shall shall not be less than: shall not be less than:
(A) of: of net area: more than: (SQ. ft.) not be less than: (Ibs.) On.} (in.)
60 31.4 31.9 0.972 22.00 22.00
49 25.2 39.7 0.780 18.50 18.50
44 22.4 44.6 0.695 16.75 16.75
38 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0,398 10.25 10.25
22 10.8 92.9 0.334 8.75 8.75
19 93 107.4 0.289 7.75 7.75
13 6.2 161.7 0.192 5,25 5.25
11 5.3 190.5 0.163 4,50 4.50
R-Value5 are determined in accordance with ASTM C687 and CS18. Complies with ASTM C764 as Type 1 pneumatic
Appl ication.
Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; lS-inch gate opening; 150 ft. x
4-inch diameter internally corrugated blowing hose.
COVERAGE CHART-ClOSEO CAVITY RETROFIT (WAllS, flOORS, CEILINGS) APPLICATIONS
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m]
REaUIRED OR MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- INSTALLED
R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER sa. FT. THICKNESS
To obtain a Bags per Conlentsofbag Weight per sq. ft,of Installed insulation
thermal resistance 1000 sq. ft. shall nolcover installed insulation shall shall not be less than:
(A) of: of net area: more than: (sQ. It.) not be less than: (Ibs.) (in.)
29 31.2 32.1 0.967 7.25
22 23.7 42.3 0.733 5.50
16 17.2 58,1 0.533 4.00
15 16.1 62.0 0.500 3.75
14 15.1 66.4 0.467 3.50
READ THIS BEFORE YOU BUY
What you should know about R-Values.
The chart shows the R-Value of this insulation. Rmeans resistance to heat flow The higher the
R-Value, the greater the insulating power. Compare insulation R-Values before you buy.
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use patterns
and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly.
@Q007 CertainTeed Corporation
A Saint-Gobain Company
30.24.298 Manufacturer Fact Insulation Sheet 2107