Loading...
HomeMy WebLinkAboutPermit Miscellaneous 2007-10-18 / r71-~-Y1-- CertainTeed III Builders Statement InsulSafe@ SP Fiber Class Blowing Insulation ~ 1)"1) ~,,,C;I' Homeowner Name I Jobsite Name . L,/()I ~...o,....sT()"'e. ~ Address , , K;\ ~ I" Installer I'Contractdr (sign) Builder (sign) /Mlf ;../,1dll /o-/~-d7 Date t:ll WIo,i'J1 {$ CompanY,Name Company Name Date Inspected By (sign if required) Dale OPEN ATTIC APPLICATION R.VALUE Tooblain a thermal resistance (R) of: 60 49 44 38 30 26 22 19 13 11 CEILINGS WALLS FLOORS I MINIMUM . MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS Bags per Contents of bag Weight per sq. ft. of Installed insulation Minimum settled insulation l000sq, ft. shall not cover installed insulalionshalJ shall not be less than; shall not be less than: of nel area: morelhan: (sq. fl.) nol be less Ihan: jibs.) (in.) (in.) 31.4 31.9 0.972 22.00 22.00 25.2 I 39.7 0.780 18.50 18.50 22.4 I 44.6 0.695 16.75 16.75 19.1 I 52.5 0.591 14.50 14.50 14.9 I 67:1 0.462 11.75 11.75 12.8 77.9 0.398 10.25 10.25 10.8 I 92.9 0.334 8.75 8.75 9.3 107.4 0.289 7.75 7.75 6.2 I 161.7 0.192 5.25 5.25 5.3 190,5 0.163 4.SO 4.SO A.VALUE I THICKNESS .1 NET AREA (SQ. FT.) INSULSA71011 BAGS USED BATTSJR.9LLS (.....) :JR I 111'12. I 2q/5 !'JCf ~ 3(J I I r').2.5 I I / ..2\ I 220 O'rl I /' :l-S I 3<"00 THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R-Value listed. ' . The maximum net coverage must not exceed that specified for each R-Value. The insulation must be installed at or above the specified installed thickness for each R-Value. . Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R-Value. ' )", . This product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. @2007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Builders Statement 2/07 Manufacturer Insulation Fact Sheet InsulSafe@ SP CertainTeed. This is CertainTeed Corporation Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 .^ . ~ COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when i~sulation is installed with pneumatic equipment in a horizontal open blow application. MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER SQ. FT. INSTALLED THICKNESS SETTLED THICKNESS To obtain a Bags per Conlenlsofbag Weightpersq,lt.of Inslalledinsulation Minimumseltledinsulation thermal resistance 1000 sq. ft. shall noleaver installed insulation shall shall not be less than: shall nalbe less than: (R)al: of nel area: more than: (SQ. ft.) nolbe less than: (Ibs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10,25 22 10.8 92.9 0.334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 53 190.5 0.163 4.50 4.50 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WAllS, flOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3 REQUIRED OR MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- INSTALLED R.VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER sa. FT. THICKNESS To oblain a Bags per Contents 01 bag Weight per sq. ft. of Installed insulation thermal resistance 1000 sq. fl. shall noleaver inslalled insulalion shall shall not be lesslhan: (Rlof: of net area: more than: (sq. ft.) not be less than: (Ibs.) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0.533 4.00 1S 16.1 62.0 0.500 3.75 14 15.1 66.4 0.467 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values The chart shows the R-Value of this insulation R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. @2007 CertainTeed Corporation A Sainl-Gobain Company 30-24-298 Manufacturer Fact Insulation Sheet 2107