Geotechnical & Construction Servires
Daily Field Report
Client:
Mr. Joe McCormack
Lane Transit District
PO Box 7070
Eugene, Oregon
Project: L TD Gateway Mall Station
3000 Gateway Street
Springfield, Oregon
Date:
Project No.:
Report No.:
Inspector:
ID No.:
09-30-08
2087170
E-21360
A Fenstermacher
525882-49
ICC
Inspection of: Reinforced Concrete
Contractor: . Brown Contracting
Weather:""'OvercasC'---' -
BF> ,,[6'.: COM2008-00440
',---
Continuous Inspection: 0
Periodic Inspection: 0
Performed inspection on the reinforcing s'teel in pedestrian walkway canopy footings at
lines C26, C28, C29, C30, C31, C32, C33, C35 and C36. Reinforcing steel was
checked for size, grade, laps, quantities, locations, ties, clearance and supports.
. Anchor bolts were checked for size, quantity and embedment. Bolts were secured in-
place with templates.
Observed the placement of 40 cu/yds. of Eugene Sand and Gravel 3000 psi concrete
'(Mix 313()65) into areas noted above. Concrete was placed directly fiom truck and was
mechanically consolidated. . Cast one (1) set of four (4) 4" x 8" concrete test cyiinders.
Notified Adam Hughes (Brown Contracting)' of on-site test results. Concrete
temperature 71 F; air temperature 62F; slump 2".
. Mr. Hughes was asked to notify our office when additional services are needed.
. To the best of our knowledge, the work inspected was in accordance with plans dated
03-12-08 and appiicable ~orkmanship provisions of the I.B.C., except if noted above.
Reviewed By:
13a~::f2::r--
Technical Manager'
c:
Rowell Brokaw- Mark Young (email)
Arig Engineering- Jok Ang (email) .
Balzhiser Hubbard- Tina Guard (em ail)
Brown Contracting- Adam Hughes (email)
. City of Springfieid
MLM:sc
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclose~ ~thout FEI Testj~g & Inspection, lnc.'s Written authori~ti~n.
7flJ NW c<meo Avenue' CavaDis, QegJ197330' phme (541) 757-4698, fax(541) 757-2991
29540 BAirport Road. Eugene, Oegon 97402. phme (541)684-3849' fax (541) 13840851
630flJ CorporntePlace, Surte2' Bend, Oregon 97701. phone (541) 382-4844 . fax (541) 382-4846
SPPl
.'..r
. .,4'._
Page 1 of 1
.'~'.ltlri;.lt~':II~.II'J~1iWSiI
Geotechnical & ConstrucIion Services
Daily Field Report
Client: Mr. Joe McCormack Project: ' LTD Gateway Mall Station Date: 10-02-08 ,
Lane Transit District 3000 Gateway Street Project No.: 2087170
PO Box 7070 Springfield, Oregon Report No.: E-21395
Eugene, Oregon Inspector: A. Fenstermacher
10 No.: 5258882-49
/ ICC
Inspection of: Reinforced Concrete Weather: Showers Continuous Inspection: D
Contractor: Brown Contracting BP No.: COM2008-00440 Periodic Inspection: It!
Performed inspection on the reinforcing steel in remaining pedestrian walkway canopy
footings (except at lines C37). Reinforcing steel was chlkked for size, grade, laps,
quantities, locations, ties, clearance and supports. Anchor bolts were checked for size,
quantities and embedment, bolts were secured in-place with templates.
Observed the placement of 33 cu/yds. of Eugene Sand an'd Gravel 3000 psi concrete
(Mix 313065) into areas noted above. Concrete was placed directly from truck and was
mechanically consolidated. .Cast one (1) set of four (4) 4" x 8" concrete test cyiinders,
Notified Adam Hughes (Brown Contracting)'of on-site results: Concrete temperature
70F;air tem perature. 62F.; slump 4".
Mr. Hughes was asked to notify our.office when additional services are needed.
To the best of our knowledge, the work inspected was in accordance with 'plans dated
03:12-08 and applicable workmanship provisions Of the LB,C" except if noted aboye.
Reviewed By:
;1, ~/Jty-
. . Michael L Meyer
Technical Manager
.
c:
Rowell Brokaw- Mark Young (email)
Ang Engineering- Jok Ang (email)
BalzhiserHubbard- Tina Guard (email) .
Brown Contracting- Adam Hughes (em ail)
City'of Springfield
MLM:sc
This,report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not ~e reproduced in partor fuUand/or any part
the"reaf be disclosed without FEI Testing & Inspection, Inc,'s Written,authorization.
. .
7ffJ tm ComeIiAvenue: CavalJis, 0'e9Jn 97330, phone (541) 757-4698, fax (541) 757-2991
29540 B Airpat Road . Eugene, 0'e9Jn 97402 . phone (541)684J849' fax (541) 684J851
63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 3824844 . fax (541 )382-4846