Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2008-10-1 , ' {.;,., "'Pl' " ".... , ".,"', ..... W:'II~lrf;"lf~'lI;'IIII~.I~I. CLIENT EWEB 500E. 4th Ave. Eugene, Oregon DATE CAST STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO. CONCRETE TEMP AIR TEMP POUR LOCATION LOAD 4 SAMPLED Geotechnical & CoosUucfun SeIviCes Compressive Stre.ngttl of Concrete , (ASTM C 39) PROJECT Hayden Bridge Water Filtration Plant Expansion Springfield, Oregon 10-01-08 2087168 6007 DATE PROJECT NO. REPORT NO. B.P. NO. Pending 09-03-08 ' CAST BY A. Fenstermacher DATE RECEIVED 09-04-08 4000 psi SPECIMEN SIZE 4" x 8" 4000 psi SACKS SUPPLIER Knife River 40-SE7 CEMENT MAX SIZE AGG. 3/4" AEA, super plasterizer AIR CONTENT 5.0% 4 TICKET NO, 3159287 SLUMP 81/2" 76" F YARDAGE 10.0 OF 55.0 TIME 12:30 PM 65~ F WEATHER Clear SPECIMENSTORAGE ASTM C31 Contact basin east buttresses, east perimeter wall and east two-thirds of North perimeter wall. (ground Level to bottom of slab elevation) Bottom lift in north wall. approximately40' from'west side. ' AVERAGE TEST AGE AREA WEIGHT TOTAL COMPRESSIVE STRENGTH TIME OF TYPE OF DATE (DAYS) (IN.') (LBSl LOAD (LBS) STRENGTH (PSI) (PSI) TEST FRACTURE- f 09-10-08 7 I '12.56 8.4 58000 4620 8:35 AM 5 10-01-08 28 12.56 8.5 75400 6000 3:15 PM 5 I 10-01-08 28 I 12.56 8.5 74700 5950 5975 3:20 PM 5 I Hold I *"1 - End Cones 2- Cone/Split 3 - Columnar 4 - Diagonal 5 - Side (top and bottom) 6 - Side (top or bottom) REMARKS: . Jake (Wildish) was advised of on-site test results. Reviewed By: , :!:~~ Technical Manager ' c: EWEB- Mike Stickling (em ail) EWEB- Wally McCulloU9h (email) OBEC- Pete Slocum (email) Wild ish Building Co.- Kevin Fitzjarrell (email) Wildish Building Co.- Jake Stucky (email) City of Springfield Knife River MLM:sc ' ~~L ~dm~\ ~6)~'L~ ," This report and/orenclosed test data is the confidential property of the client to whom iUs addressed and pertains to the specific process andlor material evaluated. As such, information contained her~in shall not be reproduced in part or full andler any part thereof be disclosed without FEI Testing & Inspection,.lnc.'s writt~n authorization. 7ffJ NN ComeIIAvenue' CavaIis, Oregon 97330, phone (541) 757-4698, fax (541) 757-2991 29540 BAirpat Road . Eugere, Oregon 97402 . phone (541) 684-3849 . fax (541) 684-3851 63050 Corporate Place, Suite 2 . Bend. Oregon 97701. phone (541) 382-4844 . fax (541) 382-4846 SfiJ Page 1 of 1 11:"II~I~:.I~~':'A'IIIUIII~llJl Geotedlnical &. Construction Servires Daily Field Report Client: EWEB Project: Hayden Bridge Water Filtration Date: 09-15-08 500E. 4th Ave. Plant Expansion Project No.: 2087168 Eugene, Oregon Springfield, Oregon Report No.: E-21209 Inspector: A, Fenstermacher ID No.: 5258882-49 ICC, Inspection of: Epoxy Anchors and Reinforcing Steel Weather: Clear Continuous Inspection: 0 Contractor: Wildish BPNo.: Pending Periodic Inspection: 0 Performed continuous Inspection during the installation of four (4) 3/4" x 24" horizontal stainless steel all thread anchors into existing buttress at the south east corner. Prior to installation, the predrilled holes were cleaned with compressed air and a brush. Verified minimum embedment of 7". Anchors 'were secured with Epcon A7 (ICC~ES ESR-6582, expiration date 11-07-09). Performed preliminary inspection on the reinforcing steer for slab numbers 1 and 2. Reinforcing steel was checked for size, grade. laps, quantities, locations, ties, clearance and supports, Note: additional slab top reinforcement at north buttress is not in place. A final inspection will be performed prior to concrete placement. Jake (Wildish) was asked to notify our office when additional services'are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 02/2008 and applicable workmanship provisions of the !.B.C., except if noted above. Reviewed By: ;11, t~ Michael L. Meyer Technical Manager c: EWEB- Mike Stickling (email) EWEB- Wally McCullough (email) OBEC- Pete Slocum (em ail) Wildish Building Co.- Kevin Fitzjarrell (em ail) Wildish Building Co.- Jake Stucky (email) City of Springfield RECEIVED E>(\Dt ~~ 0..0.'t'Lt?:J " This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process andlor material evaluated. As such, infonnation contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc. 's written authorization. 7ffJ NVV ComeIIAvenue' OwaJtis, QegJn 97330, phore(541) 757-4698, fax (541) 757-2991 29540 B Airport Road . Eugene, QegJn 97402 . phone (541) 684;3849' fax (541) 684-3851 63050 Corporate Place, Suite 2 . Bend. Oregon 97701 . phone (541 ) 382-4844 . fax (541) 382-4846 , '