HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2008-7-22 .l ~ . >5 l"'~;1 Information ,.,..,. .To Build On ' Engineering . Consulting . Testing Date Performed: Client: July 22, 2008 DAILY FIELD REPORT I Report Number: ' 722-80193-6 Ken Lafayette Advanced Mechanicallnc PO Box 397 Brownville, OR 97327 Project Name: Yolanda Elementary School Boiler Addition 3250 Yolanda Street Springfield, Oregon Project Location: P.O..No.: Type of Structure: Type of Inspection: Permit No,: Weather: COM2008-00093 Overcast Masonry Field Observations and Comments Performed visual inspection of during construction of placement of grout in the foliowing locations: 8" CMU walis top out , lift 8'10 to top of wall in new boiler room walis, ReinforCing' steel was checked for grade, size, lap, placement and 'clearances where applicable, 'AIi celis were 'relatively clean and mordr projections are within the limits of the International Building Codes, Grout 'was placed by pump and mechanicaliy consolidated, AIi celis were grouted solid, Cast one (1) set of three (3) (8x8x16) grout test samples, Contractor wa~ advised of ali on-site test results and was asked to notify our office when additional services are needed, To the best ',f our knowledge, the work inspected above was in accordance with the building department'approved design drawings specifications and applicable workmanship provisions of the International Building Codes, Tvne of Material Supplier Mix# Slump Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) Number of Samples Total Yardaile Placed Inspector: Curt Halstead, ICC# 1060568.84 CCB# 176269 Set #1 Knife Riyer 247HG3R100 10" 55' 70' 10:40 AM 1500 3 3 If you have any questions regarding this report, please feel free to contact u~ at 541-746-9649, Respectfuliy ~~mitted, i5~~r=wustries, Inc, David Smith Branch Manager c: Advance Mechanical - ken@advancemechanicalinc,com Springfield School District - gjames@sps,lane,edu Sol arc Engineering - jacky@solar-ae,net City of Springfield THIS REPORT IS PRQVIDEDFOR THE INFORMATION OF THE CLIENT QNL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD I PARTY, 8Y ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL- SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, In,,' 1Q4Q-A Shelley Street. Springfield, OR 9747[. Phone 541/746-9649. Fax 541/746-7163 ...... ~\ , 'l~~.'Information ",~. .To Build Oil Engineering . Consulting. Testing DAILY FIELD REPORT Date Performed: July 21, 2008 Report Number: 722-80193-5 Client: Ken Lafayette Project Name: Yolanda Elementary School Advanced Mechanicallnc Boiler Addition PO Box 397 Project Location: 3250 Yolanda Street Brownville, OR 97327 Springfield, Oregon P,O, No.: Permit No,: COM2008-00093 Type of Structure: Weather: Clear Type of Inspection: Masonry Field Observations arid Comments Performed. continuous inspection during the construction of placement of grout in the following locations: 8" CMU walls, 2nd 'lift up 4'10 to 8'10 above finish floor new boiler room walls, Reinforcing steel was inspected for grade, size, lap, placement and clearances where applicable, All cells were relatively clean and mortar projections are within the limits of , the International Building Codes, ,Grout was placed by pump and mechanically consolidated, Contractor was advised of all on-site test results and was asked to notify our office when additional services ,are needed, To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Codes, Tvo.. of Mat..rial Set #1 Supplier Knife River Mix # 24 7HB3R 100 Slump 10" Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) Number of Samples Total Yardage Placed Inspector: Curt Halstead, ICC# 1060568-84 CCB# 176269 700 720 10:30 AM 2,000 21/2 If you have any questions regarding this report, please feel free to contact uS,at 541-746-9649, Respectfully SUb~!eed, l ofession rv~/n~es, Inc, David Smith - Branch Manager c: Advance Mechanical - ken@advancemechanicalinc,com Springfield School District - gjames@sps,lane,edu Solarc Engineering - jacky@solar-ae,net City of Springfield RECEIVED SEP 0 3 l008 THIS REPORT 1$ PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED Professional Service Industries,. Inc. . 1040-A Shelley Street. Springfield, OR 97477 . Phone 541/746-9649 . Fax 541046-7163