Loading...
HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2008-6-11 4"~=. ~t_J >5 CcJ~',,1k;aJ & Construction Servioes Compressive Strength of Masonry Prisms ASTM C 1314 11~'II~I~;.I~Il'W;'IIIJ~IIIH'" CLIENT Mr, Jim Thomas Wildish Building Co, P,O, Box 7428 Eugene, Oregon 97401 PROJECT BPNO. , LCAFRC Complex Phase II Operations Maintenance Shop 3110 Pierce Parkway' Springfield, Oregon iCgM?008-00052 DATE PROJECT NO, REPORT NO, ,06-11-08 2077102 5875 DATE CONSTRUCTED DATE GROUTED SOLID XX DESIGN (F'M) SPECIMEN STORAGE LOCATION 05-13-08 05-14-08 HOLLOW 1500 ASTMC1314 8" CMU walls on line A, from 8 to 9, on '9, from A to C, on C, from 8 to 9 (top of slab to 40") and on line 8,6, from A to C (top of slab to 4'0"), FEI REP. R. Manama DATE RECEIVED PRISM I.D. TIME WEATHERlTEMP. MORTAR: PSIITYPE1800 psilType S SAND CEMENT, LIME OTHER TEMP. SOURCE/I.D. Spec Mix! Bagged .' GROUT: ,PSI AGG, SIZE , CEMENT ADDITIVE SLUMP TEMP. SOURCE/I.D. TICKET NO. 05-15-08 8" x 8" x 16" Smooth Face 1:50 PM Partly Cloudy/70" 2500 psi '3/8" t9" 71" ESG/Mix 312531 60003334 SPECIMEN SPECIMEN SPECIMEN NET CROSS- COMPRESSIVE TEST AGE HEIGHT ' LENGTH WIDTH SECTIONAL TOTAL STRENGTH DATE (DAYS) (IN:) (IN,) (IN.) AREA (IN,2) LOAD (LBS) (PSI) 05-22-08 8 16,00 7,625 8,50 64,81 I 176600 I 2720 06-11-08 28 16,00 7,625 8,50 64,81 I 208000 I 3210 06-11-08 28 16,00, 7,625 8,50 64,81 I 222300 I 3430 REMARKS: Jim Haines (Haines Bros, Masonry) was advised of on-site test results, Reviewed By: ~~e:~ Technical Manager c: Barrantine Bates Lee - (e-mail) kpff Consulting Engineers - (e-mail) Oregon Military Dept. - (e-mail) , City of Springfield MLM:jw AVERAGE STRENGTH (PSI) 3320 This report and/or enclosed test data is the confidential property of the client to whom iUs addressed and pertains to the specific process andlor material evaluated. As such, information contained herein shall not be reproduced.in part or full andlor any part thereof.be disclosed without FEI Testing & Inspection, Inc.'s written. authorization. 700 rm ComeII Avenue' Corvallis, Oregoo 97330, phone (541) 757-4698, fax(541}757-2991 29540 BAirport Road, Eugene, Oregoo 97402, phone (541)684<3849' fax (541) 6B4-3851 63050 Corporate Place, Suite 2 ' Bend, Oregon 97701 'phone (541) 382-4844 . fax (541) 382-4846 -)) ~.P.... ~rt. Page 1 of 1 11r.'lttlrl-;4I1~.'1lI:"IIIJ~_ Geotechnical & Construdi:ln Servioas Daily Field Report Client: Mr, Jim Thomas Project: LCAFRC Complex Phase II Date: 06-09-08 Wildish Building Co, Operations Maintenance Shop Project No.: 2077102 P.O, Box 7428 3110 Pierce Parkway Report No.: E-20311 Eugene, Oregon 97401 ' Springfield, Oregon Inspector: R. Marjama 10 No.: 5235029-X4 ICC Inspection of: Masonry Weather: Overcast Continuous Inspection: 0 Contractor: Wildish Building Co, BPNo.: CO M 2008-.00052 Periodic Inspection: 0 Performed final inspection on the reinforcing steel in the 8" CMU walls on line 8,6, from A to C, on 9, from A to C (21 '4" sloping to 27'4" following roof line). ' Reinforcing steel was checked for grade, size, lap, placement and clearance. Cells were relatively clean and free of excessive .mortar projections, Observed the placement of 3.0 cu.lyds, of Eugene Sand and Gravel 2500 psi grout (Mix 312531), Grout was placed by pump and was mechanically consolidated, All cells were fully grouted in one lift, Grout slump :1:9"; grout temperature 67F: air temperature 58F, Jim Haines (Haines Bros, Masonry) was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 10-29-07 and applicable workmanship provisions of the I.B,C., except if noted above, Reviewed By: A.'/~ Michael L. Mey(!r - , Technical Manager c: Barrantine Bates Lee -'(e-mail) kpff Consulting Engineers - (e-mail) Oregon Military Dept. - (e-mail) , City of Springfield MLM:jw This report andlor enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or futl andlor any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 700 MN CaneII Avenue' CavaIIis. CIregx197330' phme(541) 7574698' fax (541) 757-2991 29540 BAirpat Rood, Eugene, CIregx197402' phme(541)684J849' fax (541) 684-3851 63050 Corporate Place, Suite' 2 ' Bend, Oregon 97701 'phone (541) 382-4844 ' fax (541 ) 382-4846