HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2008-7-18 l...~ ;ZInjormation fI~. .To Build On . Engineering . Consulting . Testing DAILY FIELD REPORT Date Performed: July 18, 2008. Report Number: 722-80193-4 Client: Ken Lafayette Project Name: Yolanda Elementary School Advanced Mechanicallnc Boiler Addition PO Box 397 Project Location: 3250 Yolanda Street Brownville, OR 97327 Springfield, Oregon P.O. No.: Permit No.: COM2008-00093 Type of Structure: ." Weather: '. Clear .... Type of Inspection: Concrete'. Field Observations and Comme~ts Performed visual inspection of reinforcing steeLin the fol)owing 10catiDns: 8". CMU boiler room 2' 8" to 6' 8" from footing. Reinforcing steel was checked for grade, 'size, lap" placement and clearances where applicable. Reinforcing steel. was placed i~ accordance with the ap'proved 'designdrawings; details 1 and 2/04 dated 1/16/08. .AII cells were relati~ely clean and mortar projections are within .the limits of the International Building Codes. Performed continuous inspection .' during placement of grout'in the locations listed above. Grout was placed by pump arid inechanically.consDlidated', All cells grouted solid. Contractor was asked.to'notify our office when additional services are needed.. To the best of our knowledge, 'the work inspected above was in accordance with' the. building department approved design drawings, specifications' and applicable wDrkmanship provision's of the International Building Codes. " . . Tvoe of Materia] . Set #1 . Supplier Knife River Mix # 247HG3R100 Slump 8" Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) .' Number of Samples Total. Yardage Placed 2.5 Inspector: David Smith, ICBO #0877340'34 OBOA# 442 CCB# 176269 78" .,',' 11:00AM ".' .' ',.1 ';" If you haveany questions regarding this report, please feel free to contact us at 541-746-9649. . . 'd. .,..' Respectfully su~~~;ted, lSSSional s: ~~es, Inc. David~ .' . Branch Manager .. ," ....... c: Advance Mechanical - ken@advanc'emechanicalinc.com Springfield School District - gjames@sps.lane.edu Solarc Engineering - jacky@solar-ae.net City of Springfield . ." ".. ",' '. .'-. --' - . '. . THIS REPORT 1$ PROVIDED FOR THE INFORMATION OF THE CLIENT ONI:.. Y. THE R~PRODUCTION OF THIS REPo'RT;aiANY,METH,OD, 'AND'ITS TR~NS"1ITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, W/THOUTTHE WRITTEN PERA1f~S/qN.o~ ~ROFESSIONAL SERViCE iNDUSTRIES, IS PROHIBITED. Professional Service.lndustriE!s, Inc,. 1040-A Shelley Street. Springfield, OR 97477. Phone 541n46-9649. Fax 541n46-7J63 L "'~;lInformation ,.,~. .To Build On Engineering . Consulting . ~sting DAILY FIELD REPORT Date Performed: May 27, 2008 Report Number: 722-80193-3 Client: Ken Lafayette Project Name: Yolanda Elementary School Advanced Mechanicallnc Boiler Addition PO Box 397 Project Location: 3250 Yolanda Street Brownville, OR 97327 Springfield, Oregon P.O. No.: Permit No.: COM2008-00093 . Type of Structure: Weather: Clear Type of Inspection: Concrete Field Observations and Comments Performed visual inspection of reinforcing steel in the following locations: 8" CMU exterior wall from top of footing to 2' 10".and top of slab to l' 4" at interiDr wall. Reinforcing steel was checked for grade,'size, lap, placement and clearances where applicable. Reinforcing steel was placed.in accordance with .the approved design drawings; details 1 and 2/04 dated .1/16/08 (see comments). All cells were relatively clean and mortar projections are within the . limits of the International Building Codes. 'Performed continuous inspection. during placement of. grout in the locations listed above. . Grout was placed. by pump and mechanically consolidated..AII cells grouted solid. Additional Comments: Specifications call out (2) #5's at bond beams, corners, and door jamb. (2).#4's placed as per' detail at bond. beams, additional #4's placed at corners and jamb. Need Engineering approval for bond beam rebar. Contractor was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Buildin'g Codes, except as noted. Iyoe of Material Set #1 . Supplier Knife River Mix # 247HG3R100 Slump 8" Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) Number of Samples Total Yardar/e Placed 3 Inspector: David Smith, ICBO #0877340-34 OBOA# 442 CCB# 176269 67" 69" 2:00 PM If you have any questions regarding this report, please feel free to contact us at 541-746-9649.' David Smith . Branch Manager c: Advance Mechanical - ken@advancemechanicalinc.com Springfield School District - gjames@sps.lane.edu Sol arc Engineering - jacky@solar-ae.net City of Springfield THIS REPORT 1$ PROVIDED FOR THE fNFQRMA TION OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY. BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, Inc.. 1040-A Shelley Street. Springfield, OR 97477. Phone 541/746-9649. Fax 541/746-7163 l...~;l Information ,.,..,. .To Build On Engineering 0 Consulting on.stin'bAIL Y FIELD REPORT Date Performed: May 14, 2008 Report Number: 722-80193-2 Client: Ken Lafayette Project Name: Yolanda Elementary School Advanced Mechanical Inc Boiler Addition PO Box 397 Project Location: 3250 Yolanda Street Brownville, OR 97327 Springfteld, Oregon. P.O. No.: Permit No.: COM2008-00093 Type of Structure: Weather: Clear Type of Inspection: CDncrete Field Observations and Comments Performed visual inspection during the placement of concrete in the following locations: footings for boiler room building on south east corner of school. Concrete' was placed by pump and mechanically consolidated. Cast one (1) set of three (3) (4x8)'concrete test cylinders.. Conlractor was aSKed to notify'our office when additional services are needed. -To the be'st of our knowledge, the' work inspected above was iri accordance with the' building department .approved design, drawings, specifications and applicatileworkmanship provisions of ihelnternational Building Codes. Tvop. of M~tp.ri~1 Set #1 Supplier' ES& G . Mix# 314045 Slump 4.1/4" Air Content 4.5% Ambient Temperature 67' Material Temperature 72' Time Placed 2:05 PM Design Strength (psi) 4,000 Number of Samples 3 Total Yardaqe Placed 7 Inspector: Verlyn Bearden. ICC #01080077 CCB# 176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully sUb1~~~dUi . D~s~rv: C~ Inc. David Smith I . . Branch Manager c: Advance Mechanical - ken@advancemechanicalinc.com Springfield School District - gjames@sps.lane.edu Sol arc Engineering - jacky@solar-ae.net City of Springfield THIS REPORT IS PROVIDED FOR THE INFQRMA rlON OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND lTS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, 1$ PROHIBITED. Professional Service Industries, Inc.. 1040-A Shelley Street. Springfield, OR 97477. Pho.ne 5411746-964~. Fax 5411746~7163 l...~.lillnfonnation ~~,,'.:!'. To Build On 1l!nfI,." ...... ~. 'JNtIng Client: Address: Ken Lafayette Advanced Mechanicallnc PO Box 397 Brownville, OR 97327 COMPRESSION REPORT Project No.: 722-80193-1 P . N Yolanda Elementary School' rOJ. ame: Boiler Addition Location: 3250 Yolanda Streel Springfield, Oregon Placement Data: Material: Concrete Footing for boiler room building on south east corne of school Location Sampled At: 4' south of northwest corner Date Cast: 05/14/08 Date Rec'd: TiC1~~:10';: IMiX 3N1~~45 Weather: 05/15/08 Clear Desi!ln Stren!lth (psi): Cylinder No. 08-0961 08-0962 08-0963 reauired 4,000 , Test Date Field Cure (days) Lab Cure (days) j Yardage Load: 1 ITotal: 7 Supplier: . Euaene Sand & Gravel ~ Slump (in.): ASTM C143 Max. Aggr. Size: Air Content: ASTM C231 Air Temperature (F): Material Temp. (F): A$TM Cl064 Max Temp (F): Min T."mo (F): Specimen Size: Unit Weight (pet): ASTM C138 Time Cast: 2:05 PM A.dditives: Results Reported To: Compressive Strength Data ASTM C39 placed 4,000 , Diameter or Dimensions (inches) Cross Sed. Area . Cylinder WT. (s.i.)' .(Ibs.) Max Load (tbs I Compo Strength Fracture Type U Test Time . . . (psi) C12J1-0J 6 27 27 4.00 4.00 12.57 12.57 Age (days) 5/12/2008 6/11/2008 6/1 1/2008 7 28 28 4.00 I. 12.5i .. 4 -- Diagonal wIno crac~ing at ends' d 1 - Cone (bcith ends) 2 - ConeNertical Cracks (one end)- "3 - Columnar- Remarks: c: Advance Mechanical - ken@advancemechariicalinc.com Springfield School District - gjames@sps.lane.edu Solarc Engineering - jacky@solar-ae.nel City of Springfield . 8.4 49,070 8.4 68,235 8.5 69,245 5 - Side fractures (at top of bottom) Dale: B:P. No.: P.O. No.: Cast By: Field TestData 41/4" 1/2" 4.5% 6r 720 4x8 Curing Conditions: Conlraclor (Leon) 3,900 5,430 5,510 SPRINGFIELD OFFICE 1040 - A Shelley Street Springfield, Oregon 97477 (541)746-9649 - (541)746-7163 fax August 8, 2008 CCB#176269 COM200B-00093 Verlyn Bearden I day F.e. Remainder ASTM Capping Method C617;OJ 3 3 3 9:16AM 2:34 PM 2:38 PM x X X 6 - Top fra'ctures (same a"s #5 but end of ~ylin(fer is pointed) . R t Jeclfully Submilled, P ('SSiOnal fArVices Industries, Inc . , \tv f tAli "--- Slillen E. Wilder Laboralory Supervisor THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL y, THE REPRo'DUCTlON OF THIS REPORT BY ANY METHOD, AND ITS TRA'NSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL, IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES. .