HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2007-6-21 j\,' " ' 3i :lI ill! :: K-a K & A Engineering, Inc, 3327 Roanoke Ave" Eugene, OR 97408 (541) 684-9399 Voice (541) 684-9358 FAX ~ n gin ~ ~ r in 9 June 21,2007 Project: 151.06 Hayden Enterprises, Inc. 2464 SW Glacier Drive #110 Redmond, OR 97756 Subject: Jasper Meadows subdivision,-Lot 259 Springfield, OR Foundation Soils 57(;,'" fCJ "".'q' . PURPOSE AND SCOPE ' At your request, K & A Engineering, Inc, has completed a geotechnical investigation of the existing soils on the subject property, Our understanding is that a wood-framed single,family residence supported by a cast-in- place concrete spread footing foundation is proposed for construction on this site. The purpose of our investigation was'to determine the suitability of the soils for construction of the proposed structure, and provide recommendatfons for construction of the foundation, The scope of our services is limited to general suitability with respect to bearing capacity and expansive soils,. FOUNDATION PAD PREPARATION The project site is located on aresidentiallot in the new "Jasper Meadows" subdivision. The lot is mostly level and there are no apparent slope movement hazards, Foundation preparation involved constructing a level foundation pad on native undisturbed soils, This required excavating and removing approximately 2.0 to 4.0-feet of decomposing organic silt with roots from the : foundation pad area, After the excavation and removal of these soils, approximately 1 ,O,foot of 'I.-inch. minus dense graded crushed aggregate was placed and compacted over S-inch minus "pit run" fill. This served to . provide a uniform surface for footing construction.. The fill materials were pla'ced and then compacted using a vibratory steel drum roller. We tested the in'place density of the crushed aggregate fill and have determined that the average dry density exceeds 95% of maximum as determined by ASTM D69S. The field test results are attached to this report. , K- & A Engineering, Inc, . SUMMARY AND RECOMMENDATIONS The project site, as prepared, is suitable to. support the proposed foundations. We recommend a design allowable bearing capacity of 2,500-pounds per square foot. The soils present a moderate shrink/swell hazard. Foundation loads should bear on undisfurbed native silts a minimum depth of 36-inches below final grade around the perimeter foundation. The prepared foundation pad meets these recommendations. . Final grading around the foundation pad should raise the grade above the foundation using native or imported silts and should slope away from the foundation. . We recommend approval of the foundafion pad, as constructed, by the building official. Thank you for the opportunity to be of service, Please call us if you have questions or need further assistance. . Respectfully, .~ ------ Steve Schultz, EJ T. K & A Engineering, Inc, EXPIRES DEe' 3 0 2008 , Revised on 11/19/07 due to the platted lot numbers being different than the design lot numbers. Client: Hayden Enterprises Jasper Meadows-Lot 259, Springfield, OR Project: 151.06 . Page 2 of 2 June 21 , 2007 " .- Density of Soil and Soil,Aggregates:ln.Place ASTM 02922 and 03017' I Project: 151.06 I Site. Address: Jasper Meadows--Lot 259 I Permit No: I Date: 5/16/2007 I Density Test Type':IDH I Dperator:ISS I Material Type:13/4" (-) from Springfield Quarry I Maximum Dry Denstiy, pcfl128.0 I Standardization and Reference ChecklA Density . (Standard Deviations) (S,D,) 1.65 If\. Moisture, I (S,D:) . Moist Dry Density, Density, '. Water Compaction, Test No, pet pcf Content, % % Remarks 1 126.4 I 120.7 4.7 ,94.3% . " 2 128.3 I 121.4 5.7 94.8% 3 137,1 I 130.9 4.7 102,3% 4 128.4 I 121.8 5.4 95.2% I I I I I I I I I I I I I I I " I I I I I I I I I I I I I I I I I Average: 96,7% Std. Dev.: 3.78% 1.49 I I j I I I I 1 Direct Transmission (DT) (specify depth, in.) or Air Gap Backscatter (AGB) (specifiy(T)ouchable or (U)ntouchable mqde ' Test performed using Seaman Nuclear Corp model C-300, SN 21113 Client: Hayden Enterprises, Inc. Project: 151.06 K & A Engineering, Inc, . r. , , 11/19/2007