8U1 ers Statement Fiber Class Blowing Insulation
H!~e~me/JOb~e (~h~?{ I!
.
&;];rt7~a1;#~
Installer I Conlraclor (sign) { W~~::.~ oalf/Oy & ?-
BUilder (sign)
Inspected By (sign If required)
,
,
,
OPEN ATTIC APPLICATION
R VALUE
'To obtam a
thermal resistance
(R) of
60
49
44
38
30
26
22
19
13
II
CEILINGS
WALLS
FLOORS
I MINIMUM
BAGS PER 1000 sa FT
Bags per
1000sq ft
of net area
314
252
224
191
149
128
108
93
62
53
A VALUE
5H
"----
11)
I
I
MAXIMUM NET sa FT
PER BAG COVERAGE
Contents of bag
shall not cover
more than (sq ft)
319
397
446
525
671
779
929
1074
1617
1905
Company Name
MINIMUM WEIGHT- ;
POUNDS PER sa FT
Welghlpersq ft of
Installed Insulation shall
no! be lesslhan (Ibs)
0972
0780
0695
0591
0462
0398
0334
0289
0192
0163
NET AREA (Sa FT) INSULSAFE SP (.....)
VOCJ
t/'
-,
.
Date
MINIMUM
SETTLED THICKNESS
Mlnlrnumsettledmsulallon
shall not be less than
(In)
2200
1850
1675
1450
1175
1025
875
775
525
450
BATTS/ROLLS (v)
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
In accordance with the chart above,.you must Install the minimum number of bags per 1,000 sq ft of net ~rea for each
R-Value listed \
The maximum net coverage must,not exceed thaI specified for each R-Value
. The insulation must be Installed alor above the specified Installed thickness for each R-Value
Failure to Install the required minimum weight per sq ft of InsulaliOn at or above the Initial Installed thickness Will result In
reduced R- Value \
.
. ThiS product should not be mlxed\Wlth other blown insulations or the thermal claims Will become Invalid
- ~
DANGER RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES THIS WARNING DOES NOT APPLY TO TYPE Ie LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH'THERMALLY PROTECTED BALLASTS
@2007 CertalnTeed Corporation
~
THICKNESS
1t,J. 02
,
9'
7rb S-
A Saint Gobaln Company
Date
MINIMUM
INSTALLED THICKNESS
Installed Insulation
shall not be less than
(10)
2200
1850
1675
1450
1175
1025
875
775
525
450
BAGS USED
/7
30 24 298 BUilders Statement 2107
-;
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Glass Blowing Insulation
CertalnTeed Corporation
PO Box 860
Valley Forge, PA 19482
CertainTeed II
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages speCified when insulation
IS Installed with pneumatic equipment In a hOrizontal open blow application
MINIMUM MAXIMUM NET sa FT MINIMUM WEIGHT- MINIMUM MINIMUM
A VALUE BAGS PER 1000 sa FT PER BAG COVERAGE POUNDS PER sa FT INSTALLED THICKNESS SETTLED THICKNESS
To obtain a Bags per Conlenlso/bag WeTghf per sq It 01 Installed InsulatlOf! Mill/mum settlOO insulatIOn
thermal resistance 1oo0sq ft shallnolcover Installed Insulation shall shall nol be less Ihan shall not be lesstnan
(A) 01 of net area more than (sq ft) nolbelesslhan (Ibs) (m) (m)
60 314 319 0972 2200 2200
49 252 397 0780 1850 1850
44 224 446 0695 1675 1675,
38 191 525 0591 .1450 1450 ..~
30 149 671 0462 1175 1175
26 128 779 0398 1025 1025
22 108 929 0334 875 875
19 93 1074 0289 775 775
13 62 1617 0192 525 525
11 53 1905 0163 450 450
R-Values are determined In accordance with ASTM C687 and C518 Compiles with ASTM C764 dS Type 1 pneumatic
Application ,
Initial Installed thickness testing per ASTM C1374 usmg Umsul VoluMatlc III, 4th gear, 15-Inch gate openmg, 150 ft x
4-mch diameter Internally corrugated blowmg hose
COVERAGE CHART-CLOSED CAVITY RETROFIT (WAllS, flOORS, CEILINGS) APPLICATIONS
The following thermal performances are achieved at the thicknesses, weights and coverages -speCIfied when InsulatJOn
IS Installed with pneumatic equipment In Sidewalls Based on a deSign denSity of 1 6 pcf/25 6 Kg/m3
R VALUE
To obtain a
thermal resistance
(R) of
29
22
16
15
14
REQUIRED OR MINIMUM
BAGS PER 1000 sa FT
Bags per
1000sq ft
of net area
312
237
172
161
151
MINIMUM WE1GHT-
POUNDS PER sa FT
Welghfpersq ft 01
Inslalled msulatlon shall
not be less than (Ibs)
0967
0733
0533
0500
0467
MAXIMUM NET sa FT
PER BAG COVERAGE
Contents of bag
shall notcQver
morelhan (sq fl.)
321
423
581
620
664
READ THIS BEFORE YOU BUY
INSTALLED
THICKNESS
Installed msvJalJDn
shall not be lesslhan
/(m)
725
550
400
375
350
'---
(
The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the
R-Value, the greater the Insulating power Compare Insulation R-Values before you buy
,
There are other factors to consider The amount of Insulation you need depends mainly on the
(
climate you live In Also, your fuel savings from insulation Will depend up,on the climate, the type
and size of your house, the amount of Insulation already In your house, and your fuel use patterns
and family size If you buy too much Insulation, It will cost you more than what you'll save on fuel
To get the marked R-Value, It IS essential that thiS Insulation be Installed properly
What you should know about R-Values
@QOD?CertamTeed Corporation
A Samt Gobaln Company