Loading...
HomeMy WebLinkAboutPermit Building 2008-7-25 Carlson Testing, Inc. MJIn Office ro Bo,23814 Tlgard Oregon 97281 Phone (503) 684-3460 Fax (503) 684-0954 Salem Office 4060 Hudson Ave, NE Salem Oregon 97301 rhone (503) 589-1252 FIlA (503) 589-1309 Bend Office r 0 Box 7918 Bend, Oregon 97708 rhone (541) 330-9155 Fax (541) 330-9163 Daily Report of Reinforced Concrete Chent SAFEWAY STORES INC - PHIL JUTTELSTAD PrOject SAFEWAY STORE -*1094 RF:MODr,T, - SPRINGFIELD Address 1891 PIONEER PKWY E ~ SPRINGFIELD, OR JUrIsdIctIOn CTI representatIve P L SANETRA OBOA 447 was on site thIS date Ju1 25. 2008 to perform Speelal InspectIOn for Permit COM2008~0471 DFS #(s) SCOPE OF INSPECTION I Cheeked m with supenntendent or chent representative Name OTIS Company JAMES E JOHN CONSTRUCTION 2 Type of work [i] Concrete GJ Remforcmg 3 Work mc1uded [X] Sampling GJ InspeetIOn 4 InspectIOn was 'IBC W Contmuous 0 PeriodiC 5 Work performed GJ In the field 0 At preeast shop REINFORCING 1 ReViewed prevIous InspectIon reports? 2 Forms clear of debrIS? 3 Type, grade, size quantIty, spacmg and conditIon conform? 4 Venfied forms will nommally result m hardened concrete of the reqUired cross-sectIOnal dimenSIOns 5 Venfied IoeatIOn of remforemg steel, pIpes, conduIts and sleeves with respeet to minimum concrete cover 1.6 Venfied type and location ofsplIees length of contact laps and mm dIameter of bends I. 7 Venfied support & anchorage of remforemg steelm the fonns 1_8 Ventled structural embedments In the forms wIth-regard to fabneatIOn, quality and type 9 Venfied structrual embedments In the forms wIth regard to weld inSpectIOn, quantity, and permIts Issued 10 Verified cast In place anchors DescnptlOn of structure mspected [to Include gnd hnes, elevations (floors) and drawmg details] FOOTTNr, AT ?-i ~ ~~~~ n~ G Yes No N/A x x x x I X I I 1 I x I I I 1 ^ CTI Job # SPRINGFIELD S0805'00 ro Number 108018 CONCRETE MIX DeSign approved? GJ Yes 0 No 0 N/A 2 MODltored loads arnvmg atJob site for correct Mlx# 2435NE50VO Slump 4+/~1 % AIr 3 Type of samples made? 4 x 8 CONCRETE CYLINDERS Number of sets 1 Samples per set 4 4 Inspeeted plaelDg and eonsohdatlOn of approx 5 CUbIC yards of concrete x Loealion of eonerete placement [to melude gnd lines, elevations (floors) and drawmg details] SAMR AS BELOW After :.arnples are te<;ted results Will follow on break report x REPORT SUMMARY Work IDspeeted was GJ Completed 0 In progress 2 Completed work. mspected was 10 compliance wIth _ ___ ~ GJ Approved plans and specIficatIOns D Shop drawmgs o RFI 0 DeSign ehange 0 SubmIttal 0 N/A Ix Doeument #(s) S 1 1 & S 1 ? Dated 3L11-' n R 3 Noncompliance Item(s) were noted thiS date, detaIls on followlDg page(s) 0 Yes 0 No [X] N/A - 4 NoncomplIanee Item(s) were relDspeeted thiS date, details on followmg page(s) 0 Yes 0 No GJ N/A D Conform 0 Remam In progress Report(s) findlDgs were dIscussed and left With OTIS of JAMES E JOHN CONSTRUCTION Based on the Code, approval IS requIred from the BUlldlDg OffiCIal before the SPECIAL INSPECTED Ilems noted above ean be covered Carlson Testmg has no authOrity to dIrect work of contractors or subcontractors o See additIOnal report page(s) 0 Dlstnbute artaebments Page of Dally Report of Remforced Concrete CTI Job # S0805400 For 07/25/2008 Project. SAFEWAY STORE #1094 REMODEL - SPRINGFIELD Notes: In some cases more than one box may be checked for a gIVen Item on the front page Our reports pertain to the material tested/Inspected only InformatIOn contained herein IS not to be reproduced, except In full, without prIor authorIzation from thIS office Ifthere are any further questIOns regarding thIS matter, please do not hesitate to contact thiS office Respectfully submItted, CARLSON TESTING, INC Reviewed By Steven Dugger RevIew Date 07/31/2008 PLS/KMF S~FEWAY STORES INC - PHIL JUTTELSTAD TO CITY OF SPRINGFIELD BUILDING DEPARTMENT ASSOCIATED CONSULTANTS INC - MANOUCH YAGANEH BENNER STANGE ASSOCIATES - JIM PARK JAMES E JOHN CONSTRUCTION CO INC - KRIS SIMENSEN FAX/503-657-6496 FAX/503-384-0459 FAX/503-670-0235 FAX/360-696-9723