HomeMy WebLinkAboutPermit Building 2008-7-10
CertainTeed II
Builders Statement
c;- CJ (0
M~
InsulSafe@ SP
Fiber Glass Blowing Insulation
C~~
Homeowner Name I Jobslte Name
/1 ~
ilZ~~I7~ H~!:.~ ?~rC)8
BUilder (sign) Company Name Date
Inspected By (sign If reqUired) Date
OPEN ATTIC APPLICATION
MINIMUM MAXIMUM NET sa FT MINIMUM WEIGHT- MJNIMUM MINIMUM
R VALUE BAGS PER 1000 sa FT PER BAG COVERAGE POUNDS PER SO FT INSTALLED THICKNESS SETTLED THICKNESS
Tooblatn a Bags per Contenls of bag Welghlpersq fI of Installedmsula\lon MtnlmUmsetlledmsulatlon
thermalreslslance 1000 sq ft shall not cover Installed insulation shall shall nol be less than shall nol be less lhan
(R) of of net area morelhen (sq ft) nOlbelessthan(lbs) (In) (In)
60 314 319 0972 2200 2200
49 252 397 0780 1850 1850
44 224 446 0695 1675 1675
38 191 525 0591 1450 1450
30 149 671 0462 1175 1175
26 128 779 0398 1025 1025
22 108 929 0334 875 875
19 93 1074 0289 775 775
13 62 1617 0192 525 525
11 53 1905 0163 450 450
WALLS
R VALUE THICKNESS NET AREA (Sa FT) INSULSAFE SP (V) BAGS USED
1'8 I Cf f'a ';,/ I.r;A V-- 9Cf
:)/ t;' /iz. ;) t3 ('){J
'J"y- ~ (11/)-
BATTSJROLLS (v)
CEILINGS
/'
~
FLOORS
L-/"
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. In accordance With the chart above, you must Install the minimum number of bags per 1 ,000 sq It of net area lor each
R-Value listed
.'
. The maximum net coverage m-ust not exceed that specIfied for each R-Value \..;-
,
. The insulation must be Installed at or above the specified Installed thickness lor each R-Value
. Failure to Install the required minimum weight per sq It of Insulation aj or above the initial Installed thickness Will result In
reduced R-Value \
This product should not be mixed With other blown Insulations or the thermal claims Will become invalid
DANGER RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS '
@2007 CertalnTeed Corporation
A Saint Gobaln Company
30 24 298 BUilders Statement 2/07
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Glass Blowing Insulation
CertalnTeed Corporation
PO Box 860
Valley Forge, PA 19482
CertainTeed II
COVERAGE CHART-OPEN ATTIC APPLICATION
The follOWing thermal performances are achlcved at the thicknesses, weights and coverages specltlcd when insulation
IS Installed With pneumatic cqulpment In a hOrizontal open blow application
MINIMUM MAXIMUM NET sa FT MINIMUM WEIGHT- MINIMUM MINIMUM
R VALUE BAGS PER 1000 sa FT PER BAG COVERAGE POUNDS PER sa. FT INSTALLED THICKNESS SETILED THICKNESS
loobtam a Bags per Contents 01 bag Welghtpersq fI of Installed insulation Minimum settled Insulation
thermalreslslance 1000 sq ft shall not cover Installed insulation shall shallnolbelessthan shall not be less then
(R) 01 cine! area more than (sq ft) not be less Ihan (Ibs) (In) (In)
60 314 319 0972 2200 2200
49 252 397 0780 1850 1850
44 224 446 0695 1675 1675
38 191 525 0591 1450 1450
30 149 671 0462 1175 1175
26 128 779 0398 1025 1025
22 108 929 0334 875 875
19 93 1074 0289 775 775
13 62 1617 0192 525 525
11 53 1905 0163 450 450
R-Values are determined In accordance With ASTM C687 and C518 Complies With ASTM C764 as Type 1 pneumatic
Application
Initial Installed thickness testing per ASTM C1374 uSing Unlsul VoluMatlc III, 4th gear, 15-lnch gate opening, 150 ft x
4-mch diameter mternally corrugated blOWing hose
COVERAGE CHART-ClOSED CAVITY RETROFIT (WAllS, flOORS, CEILINGS) APPLICATIONS
I
The follOWing thermal performances are achieved at the thlckncsses, weights and coverages speCified when insulation
IS mstalled With pneumatic equipment In Sidewalls Based on a deSign denSity of 1 6 pcf/25 6 KglmJ
I REQUIRED OR MINIMUM MAXIMUM NET sa FT MINIMUM WEIGHT- INSTALLED
R VALUE BAGS PER 1000 sa FT PER BAG COVERAGE POUNDS PER sa FT THICKNESS
Tooblam a Bags per Conlents of bag Welghtpersq fI of Installed insulation
thermal resistance 1000sq ft shall nolcover Installed insulation shall shall not be less than
(R) of of nel area morelhan (sQ ft) nolbe less than (Ibs) (in)
29 312 321 0967 725
22 237 423 0733 550
16 172 581 0533 400
15 161 620 0500 375
14 151 664 0467 350
READ THIS BEFORE YOlJ BlJY
What you should know about R-Values
The chart shows the R-Value of thiS insulation R means resistance to heat flow The higher the
R-Value, the greater the Insulating power Compare Insulation R-Values before you buy
There are other factors to consider The amount of Insulation you need depends mainly on the
climate you live In Also, your fuel savings from Insulation will depend upon the climate, the type
and size of your house, the amount of Insulation already In your house, and your fuel use patterns
and family size If you buy too much Insulation, It Will cost you more than what you'll save on fuel
'-~ii:,i , To get the marked R-Value, It IS essential that thiS Insulation be Installed properly
""'i?~ ~ i,?Y.......w.)
~
m007 CertamTeed Corporallon
A Samt Gobaln Company
3024298 Manulacturer Facllnsulatlon Sheet 2107