HomeMy WebLinkAboutComments SUB 6/10/2008 'K. SPRlNl,II LLO U IILll 'Y BOAlZD I I [(. fRtC 'll It\ h r ( I ;-... II It 1001 Main Street Springfield OR 97477 4819 Tel 541 726 2395 Fax 541 726 2399 www subutll com TO 6/4/2008 CITY OF SPRINGFIELD DEVELOPMENT SERVICES DEPARTMENT DEVELOPMENT REVIEW COMMITTEE Date Received Planner MEM II llO! O~ PLANNER Molly Markarian CASE # SUB2008-00022 (17-02-28-00 TL 00303) [ lOVERHEAD SERVICE [X ] UNDERGROUND SERVICE II LOCATION OF NEAREST ELECTRICAL CONNECTION 60 FEET EAST OF PROPERTY LINE AT POLE 90056 III EASEMENT LOCATION AND WIDTH IV .~ STANDARD 7' STREET SIDE EASEMENT COMMENTS FROM THE APPLICANT'S NARRATIVE ON PARAGRAPH 2 STATES "THE EXISTING OVERHEAD POWER AND SERVICE POLE WILL BE RELOCATED" THIS WILL BE MORE DIFFICULT (NOT IMPOSSIBLE) AND EXPENSIVE TO DO FOR THE FOLLOWING REASONS 1) THIS IS NOT A SIMPLE SERVICE POLE BUT A DISTRIBUTION POLE IT HAS HIGH VOLTAGE PRIMARY OVERHEAD AND A PRIMARY UNDERGROUND TAP THAT FEEDS A TRANSFORMER LOCATED 180 FEET TO SOUTH ON 55TH PLACE 2) IF THE POLE MOVES, THE UNDERGROUND FEED WOULD NEED TO BE REPLACED THE UNDERGROUND CONDUCTOR WAS MANUFACTURED IN 1976 THERE IS A 50/50 CHANCE THE CONDUCTOR IS DIRECT BURIED AND NOT IN CONDUIT THIS WOULD BE A VERY EXPENSIVE CABLE TO REPLACE IF IT IS DIRECT BURIED (WOULD HAVE TO CROSS HIGH BANKS ROAD) IT WOULD STILL BE EXPENSIVE TO REPLACE EVEN IF IT WAS IN CONDUIT WE WOULD NEED TO VACTOR AT 1198 55TH PLACE TO DETERMINE IF THE CONDUCTOR IS IN CONDUIT BEFORE WE COULD PROVIDE A COST FOR MOVING THE POLE AND REPLACING THE CONDUCTOR 3) THIS PRIMARY LINE SERVES HUNDREDS OF CUSTOMERS WE COULD NOT TAKE THAT LINE OUT OF SERVICE THIS MEANS THE POLE WOULD HAVE TO BE MOVED WITH THE HIGH VOLTAGE CONDUCTORS HOT (ENERGIZED) WHICH IS DANGEROUS AND EXPENSIVE THE UNDERGROUND FEED AND RISER (THAT ARE CURRENTLY ON THE POLE TO BE MOVED) WOULD ALSO NEED TO BE MOVED ADDING EXPENSE GUENTER MATYSZAK ENGINEERING TECHNICIAN SPRINGFIELD UTILITY BOARD 541-736-3296 ~S249 F-\~T;. 600 KVAR o -- ~ I u 1 -----__~~ 150A ~ ~ J~ .1.. -_____ '" 150A ' ,- ;;:-:::::::'2\0- ------------____= _....., ~ _ ~ ~ 1... 90050-45 90052-450-:--------... ----------=---- ~, I ___ '" -L9~ 25C251 Ro 0 _______________ \ ~/ ~_~___-' o 'An '90054-45 ~L\\' /___ \ 0 90055-45V~ '------ ---~-S56 :g 90051-40 10---- ------ _______________ .l? .7 G.H N~\ - - - ~ --=:; ~ _,_ ~ ~ I \ ~ 90053-35' ---............ . ~.L \\\ ~ 90056-45 ~ ~ \ ~ "" -------~\\~----, "Beeoo 00.......::: '" 'I ~ 90057-45_ ' 56070-40 I ~ 058-350~m-- o /198 I u '~ -------------- ,90A003 _____________ 1/09 , ------------- -~ \75CI83,'J _____________ _____________ ~ 1186 [76E087 ~ '/186 I UrJoqG Q..O\lNfJ F~ I fRo^" p('I....~ croo~ To I T~f1NSrotZf\'J~ l5C (9,34 '" "I- It) "I- It) "I- (i) ~ '" h ~ ~ ~ V] /110 \/ / \ I "'>Ql1c._.d.n '" '" '" f ~ . ~ . fOLt;' _~ O~OiER. W~((rlS )0 mOVE" DWYER fRoPr2RTY ____________I 1103 I <1 ~"n71-A~ 1174 95093-30 , \ Page 1 of 1 MARKARIAN Molly From GORDON Gilbert SubdiVISion Tentative SUB2008-00022 Bill Dwyer Address 5560 High Banks Road EXisting Use Residential Proposal Create Dwyer 5-lot single family residential subdivIsion Planner Molly Markanan, Planner II Sent Tuesday, June 10, 2008 823 AM To MARKARIAN Molly Cc GERARD Alan, FECHTEL Melissa 'Rl Subject DRC Comments-SubdivIsion Tentative SUB2008-00022 Bill Dwyer {,\lol Urcl ~ oece,,,ed ~ Date'" r" ~E~ p\aOoe. " \ Fire Department Comments Water Supply OK Access 1 The fire apparatus access road/dnveway shall support an 80,000 Ib load per 2007 Spnngfield Fire Code 503 2 3 and SFC Appendix D102 1 2 The fire apparatus access road/dnveway shall have "No Parking-Fire Lane" signs posted on both sides per 2007 Spnngfield Fire Code 503 3 and SFC Appendix D103 6 Gilbert R Gordon Deputy Fire Marshal Spnngfield Fire and Life Safety 225 Fifth Street Spnngfield, OR 97477 Phone 541-726-2293 E-Mail gaordon((i)cl sonnafield or us 6/1 0/2008