Application for Building Permit
Deck Construction with Stairs
z~
1-:
50'
ol~8
L
@House
~ 16' +- 17'-
w
~
...-
.
Q)
OJ
en
.to_.:, ~'_l---:--
'.".'..:.:...;'~~.
...,' . ,'"
" \'" 'II" ,',
. gj :-
Existing Upper Deck
/'
. 17'
Proposed Lower Deck
& Stairs
f..
...
\"' ~ ]:0)0::>- *d Existing Raised Deck b
I-WO'" "':
CJ~ "" ;:"UlO ~
is 8 z"w z ~: Q)
...s 0. o"z> ~
..... ::J ;:- :1:_0 0
0 Wt)~a::
B ~ " u () , :: .0:(0.. (!)
o ::J CJ ... W..lo:D.. W ~
~l!)-'~NVt >uo" e::
wzow 0
,.. ,.. Ul n:WWID 0
'-.iuuz~t zll.>...J
.zzo~~ woo~ 0
~ 0: 0: u {) wwO::J: Owner: Micheal Ramirez
::J ::J woJ ma::~ll) .J Address: 559 South 70tll Street
01 ~ ~ h: ' \ wg<!:E: W
~ 0 0 f- ~,v. " ~OWO l.L Springfield. Or. 97478
\. <: J:UIjjj (!) Phone: 746-1546
zl-
zoo'" Z
-.s:: ... ~ oQI-~
<:>' z~,,5 l.llWW<t:...i a:: Contraclor: Larry L. Wilson
-:::::: o::~OD<c Il. LLW Inc.
"" Q~ 111<::(<:(lJ.!iJ
I- Ig~~ii: U) CCB# 147922
0 0. (J)~U)!r~ l.L 744-8053
li_l a: 1--2WO 0
" U ZUlQI-" 6i NO*15'E 50,00'
W Ul WZ!d:~Z >-
u w Ul 1-0 - 0 Dale: 2/09/05
'" Ul 0 Ul z-a:1-9 I- W
n: ~ w w a: o~wu- U 6
w Ul - .J W l)o::~W;:'
W 'j:': n: <::( [r z ww<ca~ Ir
Co Z - 0 " 0 ;;: 0.
"( 0 Z }- W 0 J:!Jo::o:::c 0.
ON:lUJ-'<(O 1-"00.1- .,;
Lot 1 00
Scale 1" = 30'
ISheet 1 of 4
Ii.,...
u
I 1
I ,
I I
: I
I I
1 I
I I
I I '" I I
-L ~ : I I '
/----: !--------I 1-----:;
Existing upper deck
Open stairway (see
typical on sheet 4)
Open stairway to existing deck
(see typical on sheel4)
\
\
'1
II
II
Approl<. 5'
, >(_4X6P.T.
/-
_4X4P.T.
" 'f" \
I.""....,\@
k-
:,j 3
I_
I
'I
______1-
/
Existing concrete patio
12" concrete cylinders
Min. depth under ground 12"
Existing ~ock
Side View of Proposed Deck & Stairs
Scale 1" = 3'
Note: Hand rails and guard rails are not shown on this sheet.
See sheet 4 for typical hand rail and guard rail details.
Guard rails will be installed on the north and east sides of the
proposed deck. Guard rails and hand rails will be installed on
both sides of both stairs accessing the existing upper deck and
the patio from the proposed deck.
=
I
L_~
t-1
I I
I I
I I
I I
I
""T
2X 12P.T.
7' minimum
Existing raised deck
House
"
I
I I
I I
(~l
\ 1,:\ \
I~~I
~I 4X6P.T. I I.
,I 4X4P.T',I-,---:L
, ,,' ,. I
I \':.' \ I~ ,I
I ,., , ,
~'~J L ~r
A-Il""
/ J\',..,.,' Concrete
. :.,'... ~ house
c ,:" ; footing
(jj \ 4" lip on footing
Mid,span support. I
Approx. 8' span :.' -'
12" concrete cylinders
Min. depth under ground 12"
Approximately 6' span -.--I
Note:
P.T. == Pressure treated for ground contact
Duradeck = Treated for above ground
Simoson Ties used to attach concrete to
posts, posts to beams, joist hangers and
misc. Siml;)son Ties will have Z max zjnc
treatment to help prevent corrosion
because of the CA.B .21PCF treatment
for ground contact lumber.
All nails, bolts, washers and nuts will be
galvanized.
Sheet 2 of 4
I
I Step framework (proposed
I deck to existing raised deck)
1_____\-___
I=OL =~ ~
L
II )I()
(U_
;JJJ
"u/ .~
Stair framew~rk (deck,to P~tiO) . , ~
Note: Hand rails and guard rails are not shown
on this sheet. See sheet 4 for typical hand rail
and guard rail details.
Guard rails will be installed on the north and
east sides of the proposed deck. Guard rails
and hand rails will be installed on both sides
of both stairs accessing the existing upper
deck and the patio.
Maximum span distance is 4' 0" between
supports for the proposed beams.
n
, " :/~
3/8" concrete boits
"""-
, ...
o
, Existing concrete patio
Existing rock retaining wall
Existing raised deck
----
---.-
--_.,----
~
(!)
.=c-t.~
4X 6 P.T.
Spliced 2 X 6 PT, nail to ea. Joist
r----,., ~ __
.J,:-
Approx. 8' span
~'
Existing6X6P.T. - .,
upper deck posts . .......
2 X 8 P.T. Hem.-Fir
'\.
/.~
~.....c-
\;1 .J
1
24" centers
~
"--'-.-.~
m,
12" concrete cylinders
~ , ,--f,,:,~
(", I \f;) _ LI:~~:~:~~I~;~~~:'o~~~ _ _~~_ _I] ,:.
,/~ I ~ -,- - - ~ - - - -C-=.".~- -tL~
f.,C] L:L ~~- ~~=='" _ tl=~:)! :;~'~~nJe~Xp~~~T.
1) gVI I J'~. II @J
, , 0 " .,' I '.
' .' b-~IT-=- == =- = 11= =- . ,'- = rj"
u U
: I:
-~
u
I~ 3' cantilever .....1:
Approx. 6' span
u-
c j
Approx. 8' span
Planned View of Substructure
Scale 1" = 3'
~
>11
I
House
,I
1
4" lip on house footing
4 X 4 Duradeck
posts (alt cedar)
"-
"
f
I Sheet 3 of 4
; 0:~::ing
~
'E
k>
'"
l
2 X 6 duradeck
~J
-'-'-~-~-'---'-----=~
-2 X 4 duradeck
---?-
-'
4 X 4 duradeck
posts (a~. cedar)
1 %,'X1~" __~.
cedar spindles
---------
- - . . - . - -
5' maximum
~~~t-
2 X 4 duradeck
Notes:
P.1. = Pressure treated for ground contact
Poi.
~ 01-
.
'\. = Gal. 3/8" carriage bolts
<,
Duradeck = Treated for above ground
The typical guard rail system shown will
be installed on north and east sides of
the proposed deck.
Notes: Spacing between posts is 5' maximum
measured at same angle as the stairs
Lower stair connection for the stairs that access
the existing upper deck is two 3/8" gal. carriage
bolts
Typical Guard Rail Section
Scale 1" = 2'
(f) """"'"" ;;.,~
C~
2 X 4 duradeck
r;;;:,::'~
'- Vllaximum spacing
2 X 6 duradeck
4 X 4 duradeck
t"osts (alt cedar)
Guard and railing systems will be installed on
both sides of the proposed stairs that access the
existing upper deck and the patio floor
/
//
/ /: I
//'~Q.-c
'- / /: I sf'-
.......-J< /: [ '/
/ I:
3/8" X 5" concrete boll -\ t',' J ./
o < r ~ Gal. 3/6" carriage bolts
2X12P.T. ~ 'I_~ 2-./
~,f;!;b ('" Concrete patio
". ",.:,..,'-:..\<, 1I.,'...\..... .\.; \"""" \ '. .'\'....-
I:J .....: .
1%"X1W'
cedar spindles
@- 2X4durad
r Proposed deck
~
2 X 12 PT. header
connected with six
3/8" gal. carriage bolts
to deck end piece
Rise will be 8".maximum & run will be 10" minimum
with a 1" nose on each step.
Height of top rail will be ~ches above the
nose of the tread ~
Three stringers (2 X 12 P.T)
Stair width of the proposed stairs accessing the
existing upper deck is 3' or 2'10" inside of the rails
Scale 1" = 2'
Stair width of the proposed stairs accessing the
concrete patio is 4' or 3'10" inside of the rails
Typical Stair & Guard/Hand Rail Section
I Sheet 4 of 4