BUILDING SPECIFICATIONS
DIVISION DIDO-GENERAL
.0101 CODES: All construction methods, materials and workmanship
shall comply wifh the 2003 EDITIOI'J OREGON DWELLING SPECIALTY
CODE FOR ONE AND TWO F AMIL Y DWELLINGS comprised 01 the 2000
Edition of ICC International Residential Code for One and Two
Family Dwellings with Oregon A.mendments dated April I, 2003,
Construction shall aisa comply with all City, County and
Federal codes, ordinances and regulations os applicable.
0102' PERMITS: The owner will provide and pay lor all permits and
fees except where other provision is mode by contract.
0103 UTILITIES: Owner to provide,
0104 SUBSTITUTIONS: Certain processes, types of equipment or kinds
of materials are specified by manufacturer IS nome, brand or
catalog number to establish a basis 01 qualify or deslrabilily
for the purpose intended. Exclusions of products of equal
quality or desirability to those specified Is not Intended,
Sub-Contractors to secure approval of substitutions from owner.
Submit sufficient Inlormatlon an specific product or producls
for evaluation. Samples may be required.
OIOS CHECKING: Canlractor shall verily and coordinate all dimensions
and conditions on all drawings and at construction site before
proceeding. Discrepancies are to be brought to the attention of
the owner, the designer, and/or the engineer as appropriate, and
fully resolved before construction is commenced.
0107 CLEANING OF SURF ACES: All surlaces must be clean and In good
condition at jab completion,
0106 COOPERATION: Contractor and subcontractors shall lully
cooperate In carrying out the work. Contractor to do or be
directly responsible for all construction bracing, temporary
shoring, furring and building In, and providing all openings.
chases, etc., required by yarious subcontractors. Where work of
one subcontractor Is installed over surfaces applied by other
trades, the commencement of work by the first mentioned
subcontractor constitutes acceptance of the surfaces, and cannot
b~ used for an excuse should subsequent failures occur.
DIVISION 0200 - SITE WORK
0201 EARTHWORK,
A, Excavations or Iills shall be so constructed or protected
that they do not endanger 1110 or property,
B. Remove trash. rubbish and other obstructions from site prior
to starting earthwork,
C. Do excavation work for structure and other work shown on the
drawings, carefully trimmed to lines and elevations required for
the work. Permanent cuts and fills shall not be steeper than 2
horizontal to I vertical unless approved by the building
allicial.
D, Stockpile excavated material for backllil purposes at
approved locations. Only clean, granular material is acceptable
for re-use.
E, The building alllcial may require 0 sail test to determine
the soills characteristics.
F. Lot sholl be provided with adequate drainage and shail be
graded so as to drain surface watsr away from foundation walls.
Said grade shall loll a minimum 01 six inches within the first
fen leet, except as restricted by lot lines, slopes, walls, etc,
where drains, swales or ot~er approved means shall
be provided to ensure drainage away from structure.
G. A foundation perimeter drain sholl be installed which ....ilI
drain roof discharge to a point at least five feet from the
foundation walls or to an approved system.
0202 BACKFILLING:
A, Backflil adjacent to concrete walls shail not be placed until
the wall has sufficlenf strength or has been sufficiently braced
to prevent damage by the backfill.
B, Bel ore placing backllll, remove all screeds, screed stakes,
other wood, debris and material subject to rot, corrosion or
subterranean termite cttack.
C, Backfill malerlal shall be clean and granular, piaced in
6-lnch lifts. and compacted.
D. Dispose of all unsuitable and excess material off site.
Conform to local laws and ordinances relating to waste disposal
on property of others.
;j
-\
~ !
DiVISION 0300 - CONCRETE
0301 GENERAL REQUIREMENTS,
A. Concrete design. components, storage, mixture, placement and
reinforcement shall conform to Chapter 4.
B, Protect all concrete Irom damage and use special care an all
exposed concrete to prevent staining or discoloration.
C, Damaged concrefe shall be repaired, or removed and replaced
with fle'M concrete at the discretion of the owner.
D. Form all concrete surfaces, ~xcept bottom of footings and top
of slabs,
E. Footings shyll be pla::ed on undisturbed soli or compacted
lill. All I ill maloriais shall be Iree 01 vegetation and
foreign material. A solis investigation report and a report of
satlslactory placement 01 lill shall be submitted to the
build;og ollicial describing fills greafer than 4" thick which
will be used to support the loundations 01 any building or
structure. Except where approved# fill depths under slabs shall
not exceed .24" for clean sand-or gra-vel and all for earth.
F. Stepped footings are required where the ground surface slopes
more than one foot In ten feet.
G. Remove all foreign matler and wet down soli before placement
01 concrete.
H. Isolation Joints shall be provided between all siabs and
loundatlan walls, using (2) thicknesses 01 30# bulldsr's lelt or
3/S11 asphalt impregnated sheeting.
0302 FORMWORK:
A, Farms shall be substantial, sutliciently tight and properly
braced to prevent leakage and maintain position and shape.
B, Farms and shoring shall not be removed until the structure
has sulllclent ~lrength to supporf salsly Ifs weight and all
loads placed fhereon,
0303 REINFORCEMENT:
A, Use only new, clean stock, Iree Iram rusf, scale, greose and
other coatings, Reier to ACI 3IB-77,
B, Reinforcement shall conlorm to ASTM A-GIS with delormations
to ASTM A-30S, Grode 40,
C. Reinforcement sizes and locations shall be os shown on plans
or os noted below:
~
SPLICE LAP LENGTH
Bar Size Concrete
,. 3 I'-G"
14 2:'-011
# S 2'-G"
Masonry
2:'-011
21_611
31_011
CONCRETE COVER
3" Concrete deposited against earth
211 Formed concrete against earth
3/4" To tap 01 slab on grade
D. A grounding electrode system shall be installed as noted in
E3S07 and E3S0B and must be coordinated wifh the elecfrical
contractor.
0304 CAST -IN-PLACE CONCRETE:
A. Basement walls and foundations not exposed to weather and
basement slabs and inferior slabs on grade, except garage floor
siabs, shall be 2S00 psi compressive strength concrete at 26
days,
B. Porches, carport slabs and steps exposed to the weather,
basement walls, foundation wolls, exterior walls, and other
vertical concrete work exposed to fhe weather and garage floor
slabs shall be 3000 psi compressive strength concrete at 26
days.
C, 3000 psi concrete and other concrete which may be subject to
freezing and thawing during construction sholl be air
entrained. Total air content (percent by volume of concrete)
shall be not less than five per cent or more than seven per
cent.
D. The minimum cement content 01 concrete mixtures for exterior
porches, carport slobs and steps that will be exposed to
freezing and thawing in the presence of deleing chemicals sholl
be as specified in ACI 31B.
E, The top surlace 01 all lootlngs shall be level. The bottom
surface 01 loatings may have a slope nof exceeding I In 10,
Footings shall be stepped where il is necessary to change ths
elevation 01 the top surface of the footings or where the slope
01 the bottom surlace 01 the looting will exceed I in 10,
F, Finishing (vertical surlaces): Correct all aggregate pockets
and other delects, Grind 011 fins and projections and remove
stains. Exterior surfaces of foundation walls enclosing living
space or storage below linished grade shall be dampproaled using
llThoroseal Foundation Coatlngll or equal.
G, Finishing (slabs), Surlace IInishes shall be on plans. Areas
nofed "Brush Finish" shall have 1/6" high attenuations, with
pattsrn and styie as approved by the owner,
030S EMBEDMENTS:
A. Anchor balfs atfachlng mud sills to concrete laundatlons,
sholl be one-half Inch diameter spaced at six feet maximum on
center. and extend at least seven inches into the concrete.
There must be an anchor bolt within twelve inches of each corner
and each piece 01 sill shall have at least two bolts,
B, Posf bases. hoid-downs, vents, door openings and conduits
shall be located accurately as shown on plans.
DIVISION 0600 - CARPENTRY
OGOI GENERAL,
A, All structural dimension lumber shall be graded and marked as
noted in Section RS02 and R602.
B, Approved end-Jointed lumber may be used interchangeably with
solid-sawn members 01 the same species and grade,
C, All structural lumbsr sizes have been designed using WWPA
grading rules. II these members bear the stamp 01 a dlllerent
grading agency, adjustmenls to sizes may need to be mode,
OG02 POSTS: Posts and columns shall be Dougias fir/Larch, Grade
Select Slructural F.O,H.C. Pasts shall be pressure treated II
so noted on plans.
~~~-------'~--""'-"""'"'-'-"""""""'<J.dl......LI<IUJ_" __
~~~ .~--._~- ~
-'--~~--n-lni 1l11T111T1 ,.111" tl1-nr,r '~"I ~".~_
,..--.-.~ ~- .-. -~-~._._~---"--~,
OG03 BEAMS, HE~,DERS AND STRINGERS: All members 2" to 4" thick and S"
or more wide shpll be Douglas fir/Larch, Beams and Stringers
Class, Grade #1. All 611 thick members shoJi be Douglas
fir ILarch, Beams and Stringers Class, Grade Select Structural.
All door and window headers sholl be 4x6 minimum unless noted
otherwiss, Glued-laminated timbers shail be 24F-V4, 01/ grade
at simple spans gnd 24F-V8, Of/ grade at cantilevers or multiple
supports unless noted otherwise.
OG04 STUDS: Studs shail be Douglas fir/Larch, Grade #2 at all load
bearing walls with size and spacing as shown on plans. Utility
grade lumber may be used il spaced per Table RG02.3(5), Cripples
under headers sholl be continuous to sole plate. Top plates In
load-bearing walls sholl be doubled with joints offset 4Sl1
minimum. Block all stud walls where required for sheathing.
Align load-bearing studs as noted in Section RG02.3.3, Interior
nonbearing partitions may be capped with a single top plate.
Foundation cripple walls shall be constructed as noted In
Section R602.9. All wood members in contact ....ith concrete shall
be pressure treated.
OGOS JOISTS: Floor and ceiling Joists shail be Dougias fir/Larch,
Grade #2, All rim joists and end joists shall be caulked In
place during Iraming, Doubie ail end joists and all joists
under parallel bearing partitions, Lap joists 611 minimum at
Interior bearing supports where possible, otherwise provide
1_1/2'1 minimum bearing on wood or metal supports and 311 on
masonry or use approved joist hangers Floor openings shall be
Iramed as noted in Section R502.10,
OGOG RAFTERS: Raffers shall be Douglas fir/Larch, Grade #2 with size
and spacing as sho....n on plans. All rafters sholl be notched to
provide full bearing at supports.
OG07 TRUSSES: Manulacfurer 01 wood Iiaor or raol trusses shail
supply caples of truss design drawings and calculations to the
building official and owner, Trusses shail be designed per section
RS02.1I.1 by a regesfered protesslonal. Designs drawings shail include
all information noted in sections R50.2.11.4 and ReOl.IO.!.
Trusses shall b.e installed with all fasteners,hangers and bracing
as required by fhe manufacturer. Truss members sholl not be drilled,
cut, notched or altered in any manner unless so designed.
*** NOTE ***
BUILDER IS STRONGLY CAUTIONED TO
VERIFY ALL TRUSS DIMENSIOIJS INCLUDING
EXACT SLOPE, REQUIRED HEEL HEIGHT,
OVERHANG CONDITION AND SPECIAL LOADING,
TRUSS DIMENSIONS SHOWN IN THESE PLANS
ARE INTENDED TO BE APPRDXIMA TE ONLY.
OG06 SHEA THING, Raal and wail sheathing shail be 7/IG" Oriented
Strand Board (OSB) or 1/2" CDX Plywood with face grain
perpendicular to supports and staggered joints. Floor sheathing
shail be as shown on plans, All slructural sheathing shall be
graded and marked as noted in Secfion RS03.2.1, RS03.3.I, RG04
or R605. If required, diaphragms and shear ....olls shall be
constructed as required by the engineer or os shown on plans.
OG09 STRESSED SKiN PANELS shail be shipped, stored handled and
installed per the manufacturer's Instructions.
OGIO SOLE PLATES: Sale plates in contact with cancrefe shall be
pressure treated douglas lir/Larch,
06i1 NAILING, Ail nailing shail be as notsd In Tabiel RG02.3(1) and
R60.2.3(2}. Metal connectors sholl be installed with all nails,
bolts or other fasteners as required by manufacturer.
OGI2 BRACING, Wail and cripple wall bracing shall be provided as per
Secllan RG02.9 and RG02.10.
OGl3 METAL CONNECTORS: Simpson strong tie, or approved equal.
OGI4 BLOCKING: Full depth solid blocking 01 utliity grade lumber is
required at all bearing walls and at the bearing points of all
joists and raffers, Cross bridging between 2xl4 and larger
rafters and 2:x12 and larger joists is required at 101_011 O.C.
maximum. Bracing between roof or floor trusses sholl be
installed as required by manulacturer,
0615 NOTCHING: Notching, cutting and drilling of studs, plaies,
joists or rafters shall conlorm to Section. RS02.6, RG02.G,
and R602,7,
OGIG ORAFTSTOPPING, Drallstopplng and Fire Blocking shall be
constructed and installed as required hy Section RS02.12 and
RG02.6,
OGi7 FINISH CARPENTRY:
A. Stairways shall be constructed as shown on plans and as noted
In Section R314,
B. Handrails and guardrails shall be constructed as she....n on
pions and as noted in Sections R31S and R3IG.
C, Wood or hardboard paneling shall conlarm to Section R702.S,
OGI6 INTERIOR WALL COVERING,
A. All interior structural components shall comply 'W'ith the
Department of Housing and Urban Dev~lopment (HUD) formaldehyde
emission standards (#24 CFR part 32BO) 01 ,2 ppm (parts per
million) lor piywood and .3 ppm lor particie board, Plywood or
particle board stamped tl meets HUD r .,;-qulremeflt~'1 or tlHUD
approvedll etc. shall be acceptable. Infsr:vr grade plywood,
wafer board, particle board, and orien1~d strand board mode with
phenol-based resins and stamped lIExp'Jsure jll shedl be
acceptable. ExteJio~ gLa!te c,pmponentz m~d. il(lih phenol-based
resins and stomped Exterior shall be '.:.'cc<,~p~i?ble.
B, All gypsum board joints and impertedlons shQII be filled and
tape~ ,
C. All surfaces shall be sanded for paint or wollpape:r or
textured as specified by owner. ' ",
D. All exposed interlor gypsum board cornors ~hall be reinforced
with metal edge trim.
E. Gypsum board shall not be installed un1i1 weather protection
is provided.
F. Gypsum board, support spacing and the size and spacing of
lasteners shall aomply with Section R702.3.
G. Garages shall be completely separated from residence and its
attic with 1/2" gypsum board applied to the 90rage side, All
structure supporting a floor-ceiling separation shell be covsred
with 1/2" gypsum board,
DGI9 EXTERIOR WALL COVERING, Siding ,hall be as shown an
plans and conform to Section R703 with attachment per Table
R703.4 unless nofed otherwise. Panel type siding shall have
shiplapped verllcal joints aver framing members and tlashed or
lapped horizontal joints.
OG20 ATTIC ACCESS: A readily accessible Iramed attic access hatch of
nof iess than 22 inches by 30 inches shall be provided 10 any
attic area having a clear height of over 30 inches.
DIVISION 0700 - THERMAL AND MOISTURE PROTECTION
0701 GENERAL:
A, The conditioned spaces 01 these plans are intended to comply
wllh Prescriptive Compliance Path I 01 Table NII04.IO) unless
noted othsrwlse.
6. All insula ling materials to comply with Sections R320 and
NII04,
C. All insulation shall be applied uniformly and in a manner to
prevent compression. Insulation shall be spliJ evenly around
pipes, wires, ducts or other obstructions and cut in around
outlet boxes.
D. Exterior joints around windows and door frames, between wall
cavities and window and door frames, between 'Wall and
foundation, between wall and roof, betwtien wall panels, at
penetrations or utility services through \~alls, floors and roofs
and all other openings in the exterior envelopes shall be
caulked, gasketed, weather-stripped or otherwise sealed.
0702 FLOOR INSULATION:
A. 211 thick (R-15 minimum) extruded polystyrene foam insulation
(approved lor under slab use) shall be installed around enlire
perimeter of monolithic floor slab in 011 heated areas. The
insulation shell extend downward Irom the top 01 the slab to fhe
bottom 01 the thickened edge, The insuiation shall be protected
as shown on plans to 0 minimum of 61' below grade. The complete
area under slab shall be covered with 6-mil polyethylene or
approved equal.
B, 2" thick (R-i5 minimum) extruded polysfyrene loam insulation
(approved for under slab use) shall be installed around enlire
perimeter of floating floor slab in all heated areas. The
Insulation shall extend downward from the top of the slob for a
minimum distance of 2411, or downward to the bottom of the slab,
then horizontally beneath the slab for a mbimum total distance
of 2411. The complete area under slab and under insulation shall
be covered with G-mil polyethylene or approved equal.
C, R-2S fiberglass batt insulation, supported by lath or
corrOSion-proof wire, shall be installed flush under floors over
all crawlspoces. Support system (wood lath, corrosion-resistant
wire, or rot-resistant twine) is required to hold insulation in
place without compressing it. Use baffles if required to
maintain ciearance around crawl space vents, Insfalll perm
maximum kraft paper vapor retarder between 2x decking and
underlayment. Separate vapor retarder is not required in floors
constructed with plywood or OSB sheafhing. Ground caver 01
G-mll black p,olyethyiene with joints lapped 12" minimum and
turned up 12 I at edges is required of all crawl spaces.
0703 WALL INSULATiON:
A, (R-21) Krait laced (I-perm dry cup maximum) high density
Iiberglassbatt Insulation shall be lace slapled to inside
(warm) surface 01 studs in all walls separating heated from
unheated spaces.
B. (R-21) Fire-rated foil-laced high density fibergiass batt
insulation shall be insfalled Inside below grade concrete walls
enclosing heated spaces. Insulation sholl be lace stapied to
2x4 framed Interior linish well held in from concrefe wall so
that insulation does not contact concrete. Insulation must
extend Irom the bottom 01 the above-grade subflcor 10 the top 01
the below-grade finished floor. The rim joist area musf be
insulated.
0704 CEILING INSULATION:
A. (R-38) Fiberglass batt or loose till fibergiass, cellulose or
rock wool insulation shall be installed on Ilaf ceilings. Loose
fili insulation may be used only where rool slope Is 4/12 or
greater and headroom at ridge Is at least 44 inches. Loose fill
insulation must be installed per label indications of pounds
required per square foot or bags per 1000 square feet.
~~-~---"-_._.~-~
-
~
B, (R-30) Foil faced liberglass batt insulation shall be
installed on sloped cellings constructed wllh single rcffers.
C. (R-30) Krait laced fibergiass batt Insulalion shall be
Insialled on ceilings with a slope of greater than 2/12 and an
attic space above.
D. (R-30) Loose till fiberglass, cellulose or rock wool
insulation may be used on sloped ceilings provided slope is 2/12:
or less and headroom at ridge is at l!3ast 44 inches. Loose till
Insulation must be installed per label Indications of pounds
required per square foot or bogs per 1000 square feet.
E, (R-21) Fall laced fiberglass batt Insulation may be Installed
In partially vaulted cellings and ceilings totaling not more
than 150 square feet in area for dormers, bay windo.....s, etc.
Space must be filled (except for required ventilation space) and
a 0.5 perm (dry cup) vapor retarder installed on warm
(in winter) side.
F. All ceilings without an attic space above sholl have a vapor
barrier with a maximum 0.5 perm rating.
G. All attic accesses and skylight wells shall be insulated to
the same R-value as the surroundIng ceiling. A ttlc access
hatches shall be weather-stripped,
H. Rigid, weather-resistant baffles ,hall be Installed to
deflect soffit ventilation air above insulation and to keep
insulation clear from attic hatches. Non-combustible baffles
shall be installed to provide 311 clearance around flues, metal
chimneys, gas vents or fixtures that require clearances or
ventilation for fire safety.
070G ROOFiNG:
A. Roofing materials and application to comply with Chapfer 9.
B. Rooling shall be applied with all Ilashing and accessories
recommended by manufacturer or os required for a watertight
assembly. Finish roofing materials shall be approved by owner.
C, Gutters shall be installed at iower edgs 01 all rool slopes,
Downspouts from gutters to discharge into stormwater drain.
Owner to approve style and color.
0707 VENTILATION,
A. Screened soffit, eave, ridge or roof jock vents sholl be
supplied as shown aD plans with a minimum rafia 01 net vent
opening to ventilated area of I to 150. Ratio may be reduced to
I to 300 II vents are arranged as noted in Section R60G. Screen
shall hove I/SP minimum to 1/411 maximim square openings of
corrosion resistant wire.
B. Crewl space shall be ventilated by means of screened openings
through foundation stem walls as shown on plans. Total net
opening and arrangement of vents sholl be as noted in Section
R40B.I. Screen shall have 1/6" square openings 01
corrosion-resistant wire or another malerlal as noted in
Section R406.2,
0706 MUD SiLL, Both top and bottom 01 mud sill shail be caulked or
gasketed.
0709 THERMAL BREAK, Concrete slabs on grade in conditioned spaces
shall be thermally broken from slabs in adjacent unconditioned
spaces.
DIVISION OBOO - DOORS. WINDOWS AND GLASS
0601 DOORS:
A, Door sizes shall be as noted on plans, with type, IInishes
and hardware as selected by owner. All egress doors sholl be
readily openable Iram the side Irom which egress Is to be made
without the use of a key or special knowledge or effort.
B. Exterior doors (except main entry door) to have a maximum
0.20 U-Value, One door (26 square leet maximum) to have
e maximum 0.54 U-Value. All exterior doors to have an air
leakage rating of 0.37 cfm maximum per square foot of door
area, Ail exterior doors shall be I 3/'1" thick minimum and be
weather-stripped (do not use sticky bock foam).
C. Doors with glozing of 2.5 square teet or larger and sliding
glass doors shall be tested and certified as noted in
Section R613.
D, Openings bstween garage and residence shail be equipped with
solid wood or honeycomb core steel doors not less than I 3/SI1
thick or 20-minute fire-rated doors.
lire-rafed doors,
E. Hinged shower doors shall open outward.
0602 WINDOWS:
A. Window brand and style shall be as directed by owner. Sizes
shall be as noted on plans. NOTE: Sizes of windows shown on
plans are nominal only, Vsrlfy rough opsnlng required belore
framing.
B, All windows shail be double glazed with a maximum 0.40
U-Value and shall meet the fenestration requirements of Section
Nil04.6, Ail windows shall be tested and certified as noted in
Secllon RGI3. Ail windows must be labeled with U-Value or
U-Value ciass except as noted in Section Nil04.4.J.
D. Sleeping rooms shall hove at least one openable egress window
or door as shown on plans and os required by Section R310.
NOTE: Sizes of windows sho....n on plans are nomInal only. Verify
CLEAR OPENING dimensions lor egress windows as required by code,
E, Windows shall be set onto a bead 01 caulking,
F. Skylights shall be constructed of double glozing, with inner
pone tempered, in a metal frame or os noted in Section R308.6
with 0 maximum 0.50 U-Value. Skylight area shall be not more
than 2 per cent of heated floor area.
G. Glass doors and enclosures fur showers, hot tubs, ....hlrlpools.
saunas, steam rooms and bathtubs, fixed, swinging or sliding
glazing in doors and storm doors, and 011 glazing and mirrors
within 2411 of doors or INithin ISII of floors, and all glazing in
railings andglazing used in barriers around swimming pools and
spas shall be tempered and permanently marked per Section R306.J.
Excep'ions are noted in Section R30B.J. R306.1.1 ANO 30B.4,
DIVISION 0900 - FINISHES
0901 GENERAL:
A. All interior finishes and materials to conform to Sections
R3i9 and R702, Wall and ceiling finishes shall have a
liame-spread classilicatian 01 not greater than 200 except as
noted In Section R319.J and a smoke density not greater than 4S0,
B, All exterior linlshes and materlais shall conform to Section
R703 and Table R703.4.
0902 INTERIOR PAINT, Latex paint with colors shall be approved by
owner.
0903 EXTERIOR PAINT, Latex or stain with color to be approved by
owner.
0904 OTHER WALL FINISHES: Contractor to coordinate with owner where
wall paper, paneling, or wainscotting ore desired.
090S FLOOR FiNiSHES:
A. Carpet shall be pralessionaily ins tailed with pad, tack strip
and metal trim as required. Carpet and pad shall be approved by
owner.
B. Cushion vinyl type shall be approved by owner.
DIVISION 1000 - SPECIAL TIES
1001 Cabinets, closet organizers, shelves and other built-ins shall
be as shown on plans and as arranged by owner.
1002 PREFABRICATED FIREPLACES:
A. Prefabricated fireplaces and chimneys may be constructed
using listed and labled zero-clearance prefabricated metal type
with triple wall stainless steel chimney pipe enclosed in INood
stud wall and chase. Installation shall be strictly in
accordance ....ith the manufacturers instructions and Section R1004.
B. All fireplaces and stoves sholl be equipped with a closable
source of outside air for combustion in accordance with Section
RIOOS. Duct shall be constructed 01 non-cambustlbie material.
In addition, lireplaces must be equipped with a tight-fitting
flue damper and gloss or metal doors. 1003 site address: copy
R32S.J.
DIVISION 1500 - MECHANICAL
mOl GENERAL, Ail heafing, ventilating, cooiing and plumbing
compcnents and installation shail comply Chapters II Ihraugh 32
and Appendix A, B, C and 0 and 011 other applicable regulations
therein referenced.
IS02 HVAC SYSTEM,
A, HVAC system shall be as shawn an plans. All equipment shall
be approved by the building official or shall bear the label 01
on approved testing agency and shall be permanently labeled as
noted in Section Mi303,
6, System shall be designed and insfailed by a qualilied
confractor, Contractor shall suppiy HV AC duct diagrams or
drawings and/or heat loss or energy use calculations, and
equipmenf speciticatlons, il required by the buiiding official.
C, Ths temperature 01 each HVAC zone shall be cantroiled by a
thermostat, All thermostats must be numericaily marked and
cap obis 01 being set between SS and 7S degrees lor heating-only
thermostats; bet....een 70 and 85 degrees for cooling-only
thermostats: and between SS and 8S degrees lor thermos tots that
confral both heating and cooiing, The system control must have
a switch or other means of setting back or shutting 011 heating
and cooling during periods at reduced need.
D, AdJustabie registers or space heaters shall bs Installed In
011 rooms except baths and utility area.
E. Ducts, plenums, returns and enclosures Installed In
unconditioned space shall be insulated to R-S. Ducts shall be
sealed 01 all joints and corners (inciuding prefabricated
joints), at junctIons between outlet registers and Interior
surfaces, and at 011 places where the ducts penetrate the
building enveiope, No ducts shall be run In exterior walls,
F. Ducts penetrating the wall or ceiling separating the dweiling
from the garage shall be constructed and installed as noted in
Section R309.1.I.
G. Nan-combustible lire-stopping shall be provided at all gaps
around mechanical lines at ceilings and floor levels.
H. Bathrooms shall be heated and ventilated with combination
heater/iighl/lan with model to be approved by owner. Bafhraom
exhaust fans to have a capacity olaf ieast SO CFM, must exhaust
directly to the exterior, and must include backdratt dampers,
I, Kitchen shall be equipped with an exhaust Ian with a capacity
at at least 100 CFM, musl exhaust directly to the exterior, must
Include a backdraft damper and must conform to the requirements
of section MiS02 or MIS04,
J. Clothes dryer shall venf direclly to the exterior 01 the
building envelope through a back-droll damper and must conlarm to the
-
-