HomeMy WebLinkAboutPermit Building 2008-7-25
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
54 I -726-3676 Fax
541-726-3769 InspectIOn Lme
SITE ADDRESS 655 S 71ST ST
ASSESSOR'S PARCEL NO 1802022105501
CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO. cOM2008-00916
ISSUED' 07/25/2008
APPLIED. 06/24/2008
EXPIRES: 0112512009
VALUE: $ 96,49500
SPRINGFIETYPE OF WORK Smgle FamIly ReSIdence
PROJECT DESCRIPTION Smgle Family ReSIdence
Owner
Address
CHRISTENSEN STEPHEN KIM
40084 MCKENZIE HWY
SPRINGFIELD OR 97478
TYPE OF USE
New
ResIdentIal
Phone Number 541-954-4260
I CONTRACTOR INFORMATION I
Contractor Type
General
Electncal
Mechamcal
Plumbmg
Contractor
CONSTRUCTION SYSTEMS 2
DA VE STUCK ELECTRIC, LLC
BEYMER HEATING & SHEET METAL CO
SPECIALTY PLUMBING CO
LIcense
33758
158177
4483
102974
Expiration Date
06/05/2009
01/01/2010
11/14/2008
11/21/2009
Phone
541-747-3554
541-485-8855
541-688-5004
541-686-4191
BUILDING INFORMATION I
1 Lot SIZe
1500 Sq Ft 1st Floor
Wall Heat Sq Ft 2nd Floor
Electnc Sq Ft Basement
Electric Sq Ft GaragelCarport
P.j!t.ll~ 0 S~J,t pther,~, .,,"0 V01' T to
ATTENdJa; PQccupant Load ,ty
f,o\I<)w rules ado!", ...
__1'<':" !, - n l,;encer
I DEVELOPMENT INFo~"'rI(1I't~_001_0G1~ ' _ 1-
0090 You may obtain,' REQ~IRED PA~I;CING
calling tlIiI,"ilI~er (, Total ,. on 2
number for thG;Orcr" Haridlc;'~ped~l
Center IS 1-[h)\J-toTn~'i~t')
760
# of Umts
Pllmary Occupancy Group
Secondary Occupancy Group
Primary ConstructIOn Type
Secondary ConstructIOn Type
# of Bedrooms
I
R-3
U
VB
# of Stones
Height of Structure
Type of Heat
Water Type
Range Type
Energy Path
Sprinkled BUlldmg
2
Front yard Setback
Side I Setback
Side 2 Setback
Rearyard Setback
Solar Setbacks
3000
10 00
5900
1400
10 00
Overlay Dlst
# Street Trees Rqd
Paved Drive Rqd
% 01 Lot Coverage
r'r, r . I PUBLIC IMPROVEMENTS'
~ '- I ..J
Street Improvement~ r::S r'Lr,j tiT SHALL EXPIRE IF THE WORK
Storm Sewer AvaIlalliJ'i -:~ "'lED U:'iDc'i THIS PERlvilT IS NOT
Special InstructIOn CO: ,',::1 'CEO 0 fi IS ABANDONED FOR
AI~Y 180 UAY PERIOD
Notes Stormwater piped to 8" pipe m private dramage easement
Paee I of 4
14,810
919
Sidewalk Type
Downspouts/Drams
-iii~
Status
Issued
CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: cOM2008-00916
ISSUED: 07/25/2008
APPLIED' 06/24/2008
EXPIRES: 01/2512009
VALUE' $ 96,49500
225 F,fth Street, Spnngfield, OR
541-726-3753 Phone
54 I -726-3676 Fax
541-726-3769 Inspection Lme
I V al~atIon DescrintlOn I
Dwelhnes
V Wood Frame
$ Pel Sq Ft
or multlpher
$10500
Square Footage
or Bid Amount
91900
Value
Date Calculated
DescriptIOn
Tvne of ConstructIOn
Total Value of Project
$96,495 00
$96,495 00
06/24/2008
L.F,,~\ PiWJ
Fee DescnntlOn Amount PaId Date Paid Receipt Numbel
*** SDC ANNEXATION CREDIT $-375 55 7/25/08 1200800000000000813
-Mechamcal Issuance Fee- $20 00 7/25/08 1200800000000000813
+ 10% Admmlstratlve Fee $95 60 7/25/08 1200800000000000813
+ 12% State Surcharge $11472 7/25/08 1200800000000000813
+ 5% Technology Fee $58 05 7/25/08 1200800000000000813
2 Baths One or Two FamIly $280 00 7/25/08 1200800000000000813
BUlldmg Permit $609 97 7/25/08 1200800000000000813
Dryer Vent $700 7/25/08 1200800000000000813
Exhdust Hoods $10 00 7/25/08 1200800000000000813
Mnllmum/Adjustment Mechanical $1900 7/25/08 1200800000000000813
Plan Review Major - Plannmg $205 00 7/25/08 1200800000000000813
Sanltdry Sewer - Improvement $469 29 7/25/08 1200800000000000813
Sanitary Sewer - Reimbursement $61717 7/25/08 1200800000000000813
SDC MWMC AdmmlstratlOn $10 00 7/25/08 1200800000000000813
SDC MWMC Improvement $990 39 7/25/08 1200800000000000813
SDC MWMC Reimbursement $9535 7/25/08 1200800000000000813
SDC SamtarylStorm AdmlD $96 29 7/25/08 1200800000000000813
SDC Transpo Improvement $862 25 7/25/08 1200800000000000813
SDC Trdnspo Relmhursement $19548 7/25/08 1200800000000000813
SDC Tr dnsportatlOn Admm $6776 7/25/08 1200800000000000813
Storm Dramage ImpervIOus Area $41661 7/25/08 1200800000000000813
Storm Sewer Each Addtll00' $1600 7/25/08 1200800000000000813
Vent Fan $1400 7/25/08 1200800000000000813
WIIlamalane Smgle Family $2,513 00 7/25/08 1200800000000000813
Total Amount Paid
$7,40738
I Plan RevIews I
06/23/2008 06/24/2008 APP LLH
06/24/2008 06/27/2008 APP TSS
06/24/2008 07/14/2008 APP CJC
Paee 2 of 4
Stormwater piped to 8" pIpe ID
private dram age easement
IRltIal Review
Pubhc Works Review
Structural Review
-~~
CITY OF SPRINGFIELD
Building/Combination Permit
Status
Issued
PERMIT NO: cOM2008-00916
ISSUED: 07/25/2008
APPLIED' 06/24/2008
EXPIRES. 01/25/2009
VALUE $ 96,495,00
225 FIfth Street, Sprmgfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 InspectIOn Lme
Plannm2 Review
06/24/2008
07/16/2008
APP TAJ
Accordmg to contractor less than 5
trees wIll be removed Addlhonal
trees wIll be fenced offfrom
constructIOn actIVIty If more than 5
trees are removed, a Tree Felhng
PermIt IS reqUired
Choose street trees from the Nallve
Trees for Hillside Development hst
m the Street Tree Handout
To Request an mspection call the 24 hour recordmg at 726-3769 All mspectIOns requested before 7 00
a.m. WIll be made the same working day, mspectIOns requested after 7'00 a m will be made the followmg
work day
~n~.nprtiow
EroslOn/Gradmg Inspecllon Prior to ground disturbance and after eroSIOn measures are mstalled
Footmg After trenches are excavated
Foundahon After lorms are erected but prior to concrete placement
Post and Beam Prior to floor msulatlOn or deckmg
Floor Insulahon Pnor to decklllg
Shear Wall Nalhng Before covermg sheathmg With fimsh matenals
Framlllg InspectIOn Pnor to cover dnd after all rough m mspectlOns have been approved
Wall InsuldtlOn Prior to cover
CeJlmg InsulatIOn Pnor to cover
Fnldl BUlldmg After all reqUIred mspectlOns have been requested and approved and the buIldmg IS complete
Underfloor Plumbmg Prior to IIlsulatlOn or deckmg
Rough Plumbmg Prior to cover and meludmg reqUIred testmg
Water Lme Prior to filhng trench and meludmg reqUIred testmg
Samtary Sewer Lme Pnor to filhng trench and meludmg requIred testmg
Storm Sewer LlIle Pnor to fillmg trench
VIer Electrical Ground Install ground rod at footmg and call for mspectlOn m conjunchon With footmg dnd/or
foundation inspectIOn
Rough ElectriC Pnol to Cover
Fmal Electnc When all electncal work IS complete
Rough Mechanical Pnor to Cover
Fmal Mechamcal When all mechamcal work IS complete
Underfloor Mechamcdl Prior to msulatlOn or deckmg and meludmg reqUIred testmg
Paee 3 of 4
_.......,,~ ~
Wir
Status
Issued
225 FIlth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 InspectIOn Line
CITY OF SPRINGFIELD.
Building/Combination Permit
PERMIT NO: cOM2008-00916
ISSUED 07/25/2008
APPLIED: 06/24/2008
EXPIRES: 01/2512009
VALUE' $ 96,49500
By signature, I state and agree, that I have carefully exammed the completed dpphcatlOn and do hereby certIfy that all
informatIOn hereon IS true and correct, and I further cerlIfy that any dnd all work performed shall be done m accordance With
the Ordinances of the City of Spnngfield and the Laws 01 the State of Oregon pertammg to the work descnhed herem, and
that NO OCCUPANCY WIll be made of any structure Without permissIOn of the Commumty ServIces DIVISIon, BUlldmg Safety
I further certify that only contractors and employees who are In comphance With ORS 701 005 wIll be used on thIS project
I further agree to ensure that all reqUired mspectlOns are requested dt the proper lIme, that each address IS readable from the
street, thdt the perm::;;1d IS located at the front of the property, and the approved set of plans wIll remam on the site at all
t.mes dUV7i ( ? _ 2- S- _0 ~
( I/'.
Owner or Con'l1'l1ctors SIgnature
Paee 4 01 4
Date
DIRECT RUNOFF TO CITY STORM SYSTEM
I IMPERVIOUS SF x I COS! PER S F CHARGE
I 120400 $0346 I = I $41661 I
RUNOFF ROUTED TO DRYWCLL DESIGNED AND CONSTRUCTED TO CITY STANDARDS
I IMPERVIOUS S F I x I COST PER S f I x I DISCOUNT RATE I I
I 0 00 I I $0 346 I I 50% I ~ I
JOURNAL OR JOB NUMBER
NAMC OR COMPANY
LOCATION
TAX LOl NUMBER
DEVCLOPMENT TYPE
NEW DWELLING UNITS
- -~--
I STORM DRAINAGE
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT WORKSHEET
I~
If/)
,~
C1
o
U
c.::
~
It/;
;8
;;j
COM2008-00916
Stephen KIm Chn"ten<;en
655 South 71 st Street
1802022105501
SINGLE FAMILY RESIDENCE
I BUILDING SIZE (Sf
LOT SIZC (Sf)
o
o
DISCOUNT
$000
I
I
I 1070
l
$41661
$41661
ITEM 1 TOTAL - STORM DRAINAGE SDC
2 SANITARY SEWER - CITY
A RLIMBURSEMENT COST
I NUMBER OF DFU', I x
I 23 I
B IMPROVEMENT COST
I NUMBCR Of DfU's I x
I 23 ,
COST PER DFU
$26 83
$617 17
I 1091
COSfPER DFU
$20 40
$469 29
1092
~ r
$1,08646
ITEM 2 TOTAL - CITY SANITARY SEWER SDC
J TRANSPORTATION
A REIMBURSCMeNI COST
I AD fTRJP RATE I
I 957 I
B IMPROVEMENT COST
I ADT TRIP RATE I
I 957 I
x
I NUMBCR Of UNIJ S I x I
I 1 I I
$19548
11093
I
x INCWTRJPFACTORI
I 100 I
COST PCR TRIP
2043
x
I NUMBLR IOF UNIJ S: x I
1094
x INCW TRJP FACTORI
I 100 I
ITEM 3 TOTAL- TRANSPORTATION SDC
=1
COST PER TRJP
$90 10
$1,05773
$862 25
4 SANITARY SEWER - MWMC
A REIMBURSEMEN r COS r
INUMBER OF fEU's I x
I I I
B IMPROVEMENT COST
INUMBER OF FEU's I x
I I I
ICOST PER fEU
I $9535
$95 35
1054
ICOST PER FEU
I $990 39
= $990 39 I 1055
($375 55) I 1054
$10 00 1056
~ , $720 19 I
~I $3,280 99 I
I~ CHARGe
I $16405
MWMC CRLDIT IF APPLICABLE (SEe REVERSE)
MWMC ADMINISTRATIVE FEE
ITEM 4 TOTAL - MWMC SANITARY SEWER SDC
SUBTOTAL (ADD ITEMS 1,2,3, & 4)
5 ADMINISTRATIVE FEE
I SUBTOTAL x I ADM FEE RATE
I $328099 I 5%
TOTAL SANITARY ADMINISTRATION FEE
TOTAL TRANSPORTATION ADMINISTRATION FEE
9629
$6776
1079
1078
Todd Smgleton
TOTAL SDC CHARGES
PREPARED BY
6/27/2008
=, $3,445 04
DATF
DRAINAGE FIXTURE UNIT (DFU) CALCULA nON TABLE
NUMBER OF NEW FlXI URES x UNIT EQUIVALENT = DRAINAGE FIX11JRE UNITS
(NOTE FOR REMODELS CALCULATE ONLY TIlE NET ADDIT10NAL FtXTURES)
NO OF FIX I URLS DRAINAGE
UNIT FIXTURE
FIXTURF TYPE NEW OLD COUIV ALENT UNITS
I BATHTUB 2 0 3 = 6
IDRJNKING FOUNTAIN 0 0 1 = 0
IfLOOR DRAIN 0 0 3 = 0
IlNTCRCCPTORS FOR GREASE I OIL / SOLIDS / El C 0 0 3 = 0
IINTERCEP roRS FOR SAND / AUTO WASH I ETC 0 0 6 = 0
I LAUNDRY TUB 0 0 2 = 0
ICLOTHESW ASHER I MOP SINK 1 0 3 = 3
ICLOTHESWASHER - 3 OR MORE lEA) 0 0 6 = 0
IMOBILE HOME PARK TRAP (I PCR TRAILER) 0 0 12 = 0
IRECEPTOR FOR RErRJG / WATER STATION I CTC 0 0 1 = 0
IRECEPTOR FOR COM SINK / DISHW ASHI:R / ETC 1 0 3 = 3
ISHOWER SINGLE STALL 0 0 2 = 0
I SHOWER GANG (NUMBER OF HEADS) 0 0 2 = 0
I SINK COMMERCiALlRESIDENl IAL KITCHEN 1 0 3 = 3
ISINK COMMCRCIAL BAR 0 0 2 = 0
ISlNK WASH BASIN/DOUBLE LAVATORY 0 0 2 = 0
ISINK SINGLE LAVATORYIRESIDENTIAL BAR 2 0 1 = 2
IURJNAL, SlALL/WALL 0 0 5 = 0
ITOILET, PUBLIC INSTALLATION 0 0 6 = 0
ITOILET. PRJVAfE lNS1ALLAlION 2 0 3 6
MISCELLANEOUS DFU TYPE NUMBER OF I:.DU'S
20 = 0
TOTAL DRAINAGE FIXTURE UNITS 23
*EDU (EqUivalent Dwelhng VOlt) IS a discharge equivalent 10 a SlnJ!:le farmlv dwelling umt (20 DFU's) set at 167 gallons per day
MWMC CREDIT CALCULA nON TABLE BASED ON COUNTY ASSESSED VALUE
II
I
I
I'
I
I
I
I
,
--I--~~~i~~~T~~O 'Ij
-, $5 29 ,",1+
~- --'-$529__ I 1- f
_lJ _ .$519+ li!cl-4""- -
- $5 12~:f.0't~
, -
:::" ,;:,":~ $4 98 -,~, ';
~~~-d $4 80 ,~ I
IT -II. L -$4 63- -=--=.:::.-_ -,,-
L" I
: "]"1','$440 I 1 ~
~ 'T 1- I "I
'-,$407 '
1 i, -~i I;
1'1. ~ ,$367- ""i_-, - I
, c -$322 r"-
__I... _L
, r
- $273 ,-
I r~::'1..u.'
$2 25,~ ,1 -,
_ -'..-$1 80~t 'I "
L ~,lL_L $1 59 - ..~- -I::
't'" - I
$145 "'"'/'
" - L ;-
$~2-.?,__,J I'~
'" -L$1 09 -n:~""-1r~=~ I
f-r ~ -"'=~-t$0 92 ~ '
L t: ' --, ~1-"" I
, $072 IT ft 'JurJ-
-, $048' -' :J-~~l
- - fir
~ $0 28LL -~::....!
'-e- "1-=
~-"--~" $0 09 , " I
- "
; -:__~ _$0 O~::_-_~ ,
YEAR
ANNEXED
BEFORE 1979
1979
1980
1981
1982
1983
]984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
]997
1998
1999
2000
2001
IS LAND ELGIBLE FOR ANNEXATION CREDIT"
(Enter I for Yes, 2 for No)
IS IMPROVEMENT ELGIBLE FOR ANNeX CREDIT"
(Enter I for Yes, 2 for No)
BASE YEAR
1979
CREDIT FOR LAND (IF APPLICABLE)
VALUE /1000 CREDIT RATE
$70 99 x $5 29
~ ,
$37555
CREDIT FOR IMPROVEMEN f (IF AFl ER ANNEXATION)
VALUE / 1000 CREDIT RA TC
$000 x $529 ~ ,
o
=
$37555
TOTAL MWMC CREDIT
\
'I
I
I
I
I
11
I
I
I
il
,\
225 FIfth Street
Sprmgfield, Oregon 97477
541-726-3759 Phone
"I'AtN~'!.!'IItLD~~
J
.. If
".JA "'II r
81L-
CIty of Sprmgfield OfficIal ReceIpt
Development ServIces Department
PublIc Works Department
Job/Journal Number
COM2008-009l6
COM2008-009l6
COM2008-00916
COM2008-009l6
COM2008-009l6
COM2008-00916
COM2008-009l6
COM2008-009l6
COM2008-00916
COM2008-009l6
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-009l6
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-00916
COM2008-00916
Payments
1 ype of Payment
Check
cRecemtl
RECEIPT #,
1200800000000000813
Date. 07/2512008
DescnptlOn
Storm Drainage ImpervIOus Area
Santtary Sewer - Reimbursement
Samtary Sewer - Improvement
SDC Transpo Reimbursement
SDC Transpo Improvement
SDC MWMC Reimbursement
SDC MWMC Improvement
SDC MWMC AdministratIOn
SDC SamtarylStorm Admin
SDC TransportatIOn Admin
*** SDC ANNEXATION CREDIT ***
BUilding Permit
2 Baths One or Two Family
Storm Sewer Each Addtl 100'
Plan Review Major - Planning
Vent Fan
Exhaust Hoods
Dryer Vent
MInImum/AdJustment MechanIcal
-MechanIcal Issuance Fee-
WllIamalane Single Family
+ 5% Technology Fee
+ 12% State Surcharge
+ 10% Administrative Fee
Paid By
Item Total
Check Number AuthOrizatIOn
Received By Batch Number Number How Received
CONSTRUCTION SYSTEMS 2 NjM
18196
In Person
Payment Total
Page 1 of 1
11 30 30AM
Amount Due
41661
61717
469 29
19548
862 25
9535
990 39
1000
9629
6776
(37555)
609 97
280 00
1600
205 00
1400
10 00
700
1900
2000
2,51300
5805
11472
9560
$7,407 38
Amount Paid
$7,40738
$7,407 38
7/25/2008
r
".j
\.
"
,""''''
'"
-a
l'nginl'Pring
;J
V9~1
K &A Engineering, Inc.
3327 Roanoke Ave., Eugene, OR 97408
(541) 684-9399 Voice
(541) 684-9358 FAX
August 27, 2008
Project 106.08
Construction Systems 2
40084 McKenzie Hwy,
Springfield, OR 97478
Subject: Foundation pad constru~ction _~ ~__ ,
Springfield pennit no. ~ 'OOM2008-00916
655 S. 71~ St, Spring n
PURPOSE AND SCOPE
As requested, K & A Engineering, Inc. has made on-site inspections during con.struction of the foundation pad
for the new single-family dwelling proposed for construction at the subject project site. The purpose of our
inspections were to provide on-site guidance for foundation pad preparation so that the pad would provide
adequate support to the building foundation.
The scope of our services included a visual inspections of the site during foundation pad construction,
recommendations made on-site to you and your contractor, and this letter that summarizes our observations
and recommendations.
FOUNDATION PAD CONSTRUCTION
Ourunderstanding is that the proposed foundation for the subject project consists of a conventional cast-in-
place reinforced concrete spread footing system that includes a continuous perimeter strip footing/stem wall
and isolated and strip footings within the crawlspace.
Soils at the site, as exposed during excavation, consisted of 1.5 to 2.0,feet of brown gravelly silt with roots over
1 to 2-feet of tan/orange, stiff, plastic silt or clay over decomposed sandstone/siltstone.
The depth of the excavation ranged from 2.5 to 4.0-feet with the highest cut located at the southeast comer (the
highest grade of the natural ground surface). Groundwater was intercepted in any of the excavation.
Based on our recommendations, all organic soils were stripped and removed from the foundation pad area. The
foundation area was excavated so that subgrade underneath footings consisted of stiff tan/orange plastic
silt/clay or into decomposed sandstone/siltstone at an elevation that is at least 2.5-feet below the final elevation
of the ground surface on the outside of the perimeter foundation. All loose soils were removed from the native
silt/clay or sandstone/Siltstone subgrade, and the native silt/clay or sandstone/siltstone subgrade underneath
footings was covered with 2 to 3-inches of %-inch (-)dense-graded crushed aggregate.
,
K & A Engineering, Inc.
SUMMARY AND RECOMMENDATIONS
General Suitability .
The founda~on pad, as prepared, is suitable to support the proposed founda~on. The stiff plas~c clay/silt and
decomposed sandstone/siltstone subgrade, as prepared, is suitable to support the proposed founda~on.
Foundation Support
Foo~ngs should be supported by the prepared founda~on pad subgrade. The final grade around the perimeter
founda~on should be at an eleva~on of at least 2.5-feet above the subgrade underneath the perimeter strip
footings. We recommend an allowable bearing capacity of 1 ,500-pounds per square foot for conven~onal strip
and spread foo~ngs supported on the prepared subgrade.
Retaining Wall
A portion of the excava~on on the southeast corner of the founda~on pad required and excava~on that exceeded
the height of a conventional footing and stem wall. K & A Engineering, Inc. provided recommendations for a
footing and stem wall designed to retain the cut embankment. These recommendations were provided under a
separate cover letter dated August 20. 2008.
Drainage
We recommend !hat a footing drain system be installed at the base of the perimeter strip footing at the exterior
side of the foundation. This system consists of a perforated drainpipe covered with a minimum of 12-inches of
drain rock that is enveloped with separation geotextile. The perforated drainpipe should be connected to a solid
drainpipe that routes intercepted groundwater to an appropriate disposal pOint for stormwater.
The roof drain system should not be connected to the footing drain system. Roof drainage and foundation
drainage may be routed in one solid collector pipe downhill of the foundation.
Rnally, we recommend installation of a low-point crawlspace drain in the northeast portion of the crawlspace or
at the lowest area of the crawlspace. The low-point crawlspace inlet should be located at the subgrade and
should be covered with a screen or grate to prevent soil or gravel from entering the drain. The low-point drain
should be routed to a suitable disposal point for storm water, and may be connected to the common
rOOf/footing drain collector pipe downhill of the foundation.
Expansive Soils
The tan/orange stiff plastic sins/clays have a moderate potential for volume change wnh changes in water
content. .our recommendation for minimum subgrade depth below the final perimeter grade (see above) was
made to minimize the hazard of expansive soil.
SPECIACATlONS
Drain Rock
Drain rock should consist of 1 'h to 3-inch clean, open-graded, and durable round river stone or angular quarry
stone. '
Sull9rade
Subgrade refers to compacted, graded native stiff tan/orange silts and clays or decomposed sandstone/siltstone
underneath stripped and grubbed organic layers that will support foundation loads.
Project: 106.08 655 S. 71" St., Springfield, Oregon
Client Construction Systems.2
Page 2 of 4
August 27, 2008
K & A Engineering, Inc.
Separation Geotexiile
Separation geotextile should consist of a non-woven, needle-punched, polypropylene fabric meeting the
following specifications:
Table 1 - Separation Geotextile Specitications
I Properly Test . Specification
Method
I Grab Strength ASTM >1.4kN
04632
I Tear Strength ASTM ;" 0.5 kN
04533
I Puncture Strength ASTM > 0.5 kN
04833
I Burst Strength ASTM > 3,500 kPa
03786
I Permittivity ASTM > .02 sec-1
04491
I Apparent Opening Size (ADS) ASTM US Std. Sieve 70
04571
I Ultraviolet Stability ASTM > 50% re1. After 500 hours
04355 exposure
Separation geotextile should be placed free of wrinkles or other discontinuities. Tom, punctured, or damaged
fabric should be replace. Separation geotextile should have a minimum lap at seams of 12-inches.
Drain Pipe
Drainpipe for foundation drain systems shall consist of 3-inch minimum diameter rigid AOS3000 Triplewall pipe
or schedule 40 PVC. Perforations should be either prefabricated by the pipe supplier, or constructed by drilling
'h-inch diameter holes spaced at 8" into solid pipe: Perforations should be placed down. .
Project: 106.08 655 S. 71~ S1., Springfield, Oregon
Client: Construction Systems 2
Page 3 of 4
August 27, 2008
:
K & A Engineering, Inc.
LIMITATIONS AND USE OF GEOTECHNICAL RECOMMENDATIONS
This report has been prepared for the exclusive use of Construction Systems 2 and its design consultants and
contractors for the proposed residential development.
This geotechnical investigation, analysis, and recommendations meet the standards of care of competent
geotechnical engineers providing similar services at the time these services were provided. We do not warrant
or guarantee site surface or subsurface conditions. Exploration test holes indicate soil conditions only at
specific locations (i.e. the test hole locations) to the depths penetrated. They do not necessarily reflect soil/rock
materials or groundwater conditions that exist between or beyond exploration locations or limits.
The scope of our services does not include construction safety precautions, techniques, sequences, or
procedures, except as specifically recommended in this report. Our services should not be interpreted as an
environmental assessment of site conditions.
\
\
Thank you for. the opportunity to be of service. Please call us if you have questions or need further assistance.
Respectlu lIy,
~RES liJ~t"
Michael Rembold!, P.E.
Principle, K & A Engineering, Inc.
Project: 106.08 , 655 S. 71" St., Springfield, Oregon
Client: Construction Systems 2
Page 4 of 4
August 27, 2008