HomeMy WebLinkAboutPermit Correction Notice 1976-1-27 '--' 1...-... ."'-' 1 e . CITY OF SPRINGFIELD CITY HALL 344 NORTH "A" STREET SPRINGFIELC, OREGON CATF Gem Lumber Company 3539 Commercial Springfield, OR 97477 f ~ l I I l ~.. Mill Maintenance Electrical Inspection on 1-26-76 2~ hours inspection at $15.00 per hour January 27, 1976 - -... ~,--...._-- ,.---- - . -- .. .-- ~_.- ,-. _J TOTAL $37.50 ._#..-" '--~em Lumber Cant. WIRING INSTALLER ADDRESS OF INSTALLATION TYPE OF STRUCTURE ~le~rical Inspection tftport ADDRESC: L.ABEL Nf"" USED HEIGHT W"RING METHOD: NON-METALLIC SHEATHED CABLE 0 ARMORED CABL.E 0 CONDUIT 0 , OW N E R CHANGES ORDERED ADDRESS 23. Hand held hoist button at log dumD has bad cord. ground button. 747-4221 (CITY OR TOWN) DATE POWER CO. (CITY OR TOWNI Should hI" 1"'..e.p.l.a..c..et'h l..-=-S!.; 1"'1" to- . 2~ hours inspection at $15.00 per hour - $37.50 COVER INSPECTOR -a.? FINAl ~ ACCOMPANIED BY WIRING INSTALLER .---- '----. Elect~cal Inspection RlBort. 747-4221 Mill Maintenance Inspection 3539 Commercial ADDRESS (CITY OR TOWN) ":t"1Q ('n.,..."o...,.i,,1 L.ABEL Nf"" ADDRESS OF INSTALLATION Mill 1-26-76 TYPE OF STRUCTURE USED HEIGHT DATE WIRING METHOD: NON.METALLIC SHEATHED CABLE 0 ARMORED CABLE 0 CONDUIT 0 OWNER POWER CO, Gem Lumber Company 3539 Commercial ADDRESS (CITY OR TOWN) CHANGES ORDERED 1. Repair and replace bad pipe and wires on log haul. 2. Replace J box and repair conduits under cut off saw. 3_ T..abel circuit!': i~np1 at cut nff !':s:ltJ!':,' 4. Remove wires at east cut off saw location. 5. Replace covers on J-boxes under cut-off saw. 6. Secondary of lighting transformer is not grounded. \ I 8. 9. 10. 11. l2. 13. 14. 15. 16. 17. l8. 19. 20. 21. 22. " COVER 7. What appears to be ground wire under cut-off saw is loose. Did not find a ground rod. Remove or repair all broken conduits on barker conveyor system. Secure conduits to bark bin. Secure conduit to bark conveyor motor. Replace cover on range recp. in chipper shed. Label breakers in lighting panel for loads. Cannot see transformer secondary ground at chipper center. Secure conduits that are loose and bent under chipper conveyor. Replace covers on boxes. Secure conduit on west side of log haul to mill. Seal all open KO's. At head rig M.C.C. replace cover and KO seals in 4-S box. Replace broken flex to motor for little log haul. Receptacles in filing room all have re~~r~~d polarity J' -L.. ... - 4-0 cover must be replaced near tank ,up.de,:r"fuill. Much E.M.T. conduit thru plant is pulled apart or b'ent should be re1)laced with rigid steel conduit. FINAl .11 ~(j~~ {1 r; ACCOMPANIED BY INSPECTOR