Loading...
HomeMy WebLinkAboutPlans Applicant 12/9/2024 (3)12-31-2024 SHEET JOB #1159 1B OF 9CITY SITE PLANSCALE @ 1/8" = 1'- 0"THESE DRAWINGS ARE THE PROPERTY OF: "LUKE DESIGNS" AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER EXCEPT WITH THE PROPER WRITTEN PERMISSION OF LUKE DESIGNS, INC. DATE: REVISED: DESIGNED BY: ENGINEERED BY: MONTY LUKE DECEMBER 2, 2024 FINAL PLAN287 DEADMOND FERRY RD.SPRINGFIELD, OREGON 97477DESIGN: 541-746-7757 / ENGINEERING: 541-357-3031DesignsAND ENGINEERINGPAPER SIZE @ 36" X 24"PROPOSED 6-PLEX TOWNHOME DESIGN FOR:GS ENTERPRISES OREGON, LLCLOCATED AT: 503 17TH STREETSPRINGFIELD, OREGON 97477BUILDER: GEREMIAH ROBERTS #541-852-2312AMMON LUKE SITE PLAN 1/8" = 1'-0"NORTH17TH STREET54.36'16'-0" EXISTINGDRIVEWAY102'-0" WIDE FOR (6) 17' WIDE UNITS (SHOWN)18'-0" (MIN)24'-0" (MIN)12'-0"8'-0" (+-) 188.70' 188.70' (1) CAR GARAGE 19/0 X 16/0 UNIT #A (1) CAR GARAGE 19/0 X 16/0 UNIT #B (1) CAR GARAGE 19/0 X 16/0 UNIT #C (1) CAR GARAGE 19/0 X 16/0 UNIT #D (1) CAR GARAGE 19/0 X 16/0 UNIT #E (1) CAR GARAGE 19/0 X 16/0 UNIT #F 5'-0"(6) 9/0 X 18/0 PARKING TOTAL IMPERVEOIS DRIVEWAY/PARKING AREA (4,781 SQ. FT) WATER RUN OFF WILL DRAN TO FRONT WATER GARDEN 23'-0" (MAX) 132'-0" (MAX)5'-0" x 29'-0" (144 SQ. FT.) WATER GARDEN4'-0"5'-0"54'-0" 63'-0" DRIVEWAY24"7'-0" P.U.E.S.U.B. POWER BOX HERE (7) S.U.B. WATER METERS HERE EXISTING S.U.B. POWER POLE HERE CONCRETE/ASPHALT FLAT WORK TO BE DETERMINED AND CONFIRMED AT THE SITE BY CONTRACTOR (TYP) ALL UTILITY HOOK-UPS TO BE DETERMINED AND CONFIRMED AT THE SITE BY GENERAL CONTRACTOR PER ALL LOCAL BUILDING CODES (TYP) ALL BUILDING ROOF WATER RUN-OFF WILL DRAN TO 10' X 32' X 6' DEEP (320 SQ. FT.) UNDERGROUND SOAKING TRENCH TO BE LOCATED HERE - SEE ALL ENGINEERING SPECS PROVIDED BY ERIC FAVREAU P.E. ALL PARKING LOT WATER RUN-OFF WILL DRAN FROM THE REAR PROPERTY TO THE FRONT, AND INTO A 5' X 29' X 30" DEEP (144 SQ. FT.) WATER GARDEN PLANTER AS SHOWN SEE ENGINEERING SPECS PROVIDED BY ERIC FAVREAU P.E. IF MINI-SPLIT DUCTLESS HEAT PUMP SYSTEMS ARE USED, THE OUTIDE A.C. UNITS WILL BE LOCATED HERE. GENERAL CONTRACTOR TO CONFIRM AT THE SITE NEW MAIL BOX FOR EACH TOWNHOME TO BE LOCATED ON EXTERIOR WALL AS MARKED HERE TELECOMMUNICATION UTILITY CABINET TO BE LOCATED AT THIS LOCATION - TO BE CONFIRMED BY CONTRACTOR PROPOSED SEWER EASEMENT LINE HERE TO BE CONFIRMED NOTE: NOTE: A B A B 18'-0" DRIVEWAY1'-4"10'-0"(CONT)5'-0"30'-0"17'-0"17'-0"17'-0"17'-0"17'-0"17'-0" C C C C C C C ALL ASPHALT PAVING TO HAVE 1/8" PER FOOT MIN. SLOPE TO FRONT WATER GARDEN (TYP) E D D D D D D D 7'-0" PUE 6'-0"10'-0" (MIN) 7'-0" P.U.E. (CONT)5'-0"10'-0" E F F SSSSSSSSSSSSSSSSSSSSSSSSSSSSSDSDSDSDSDSDSDSDSDSDSDSDSDSDEX SD17TH STEX 12'APPROACH28' PAVE 40' ROW TL 3300 TL 3200 TL 3400 TL 2000 TL 2100 ±2.5'OHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWTREE TO BE REMOVED SPRINGFIELD, OR 97477503 17TH STSITE ASSESSMENTNO.APPROVED:DESCRIPTIONREVISIONSBYDATE503 17TH ST SPRINGFIELD, OR 97477 TL 17-03-36-24-03300 SIZE: 0.23 ACRES APPLICANT: GS ENTERPRISES OREGON LLC (541) 852-2312 APPLICANT'S REPRESENTATIVE: FAVREAU ENGINEERING 2206 COUNTRY HAVEN DR EUGENE, OR 97408 (541) 556-4425 PROPERTY INFO SHEET C1 EUGENE, OR 97408 (541) 556-44252206 COUNTRY HAVEN DRE R IC J. F A V R E A USEP. 12 , 2 0 1 7OREGONREGISTERED PROFES S I ONALE N G I NEER DATE: 11/26/24 TL: 17-03-36-24 LOT: 03300 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 10 SITE NO SCALE VICINITY MAP LEGEND THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS AND THE CITY OF SPRINGFIELD. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND INDEMNIFY AND HOLD DESIGN PROFESSIONALS HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. ANY ESTIMATED QUANTITIES HEREON ARE ONLY FOR THE PURPOSE OF OBTAINING THE NECESSARY PERMITS, AND FAVREAU ENGINEERING, LLC DOES NOT GUARANTEE THE ACCURACY OF THE ESTIMATED QUANTITIES. THE CONTRACTOR SHALL PERFORM HIS OWN QUANTITY TAKEOFF BEFORE SUBMITTING A BID FOR ANY PORTION OF THE IMPROVEMENTS COVERED BY THESE PLANS. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS INCLUDING POTHOLING AND LOCATING EXISTING UNDERGROUND UTILITIES AND SHALL REPORT DISCREPANCIES TO THE ENGINEER PRIOR TO COMMENCEMENT OF WORK. THIS DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE EXISTING PUBLIC SANITARY SEWERSS PROPERTY BOUNDARY ENGINEER'S NOTE NOTICE TO CONTRACTOR SOIL TYPE 96 - NEWBERG LOAM, SOIL GROUP A - WELL-DRAINED FEMA THE SITE IS LOCATED IN ZONE "X" AS SHOWN ON FIRM COMMUNITY PANEL NO. 41039C1142F, DATED JUNE 2, 1999. NO BASE FLOOD ELEVATION DETERMINED. WELLHEAD PROTECTION THE SUBJECT SITE IS WITHIN THE 20-YEAR TIME OF TRAVEL ZONE, PER CITY MAPPING. EXISTING PUBLIC STORM DRAINSD EXISTING OHVERHEAD WIRE EXISTING TREE OHW C1 - SITE ASSESSMENT C2 - SANITARY SEWER PLAN SHEET INDEX SSSSSSSSSSSSSSSSSSSSSSSSSDSDSDSDSDSDSDSDSDSDSDSDEX SD17TH STEX 12'APPROACH28' PAVE 40' ROW TL 3300 TL 3200 TL 3400 TL 2000 TL 2100 ±2.5'OHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWSS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS INSTALL (6) 4" PVC SEWER LATERALS 2% SLOPE MIN INSTALL SANITARY SEWER MANHOLE. ENSURE 6" OF SPACING BETWEEN ENTRIES INTO MANHOLE, WITH NEW INVERT ELEVATIONS AT A MINIMUM OF 0.1' ABOVE EXISTING IE OUT ELEVATION, AND A MAXIMUM OF 1' ABOVE EXISTING IE OUT ELEVATION. POTHOLE EXISTING SANITARY SEWER LINE PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES. SS PROP SSMH RIM: 466.91 IE OUT EX (N): 459.04 IE IN EX (S): 459.09 IE IN PROP (W): 459.14 - 460.04 EX 8" SS IN EX 8" SS OUT 6" MIN 6" MIN0.1' MIN1' MAX4" LATERAL (TYP) MANHOLE CONECTION DETAIL NO SCALE SPRINGFIELD, OR 97477503 17TH STSEWER PLANNO.APPROVED:DESCRIPTIONREVISIONSBYDATESHEET C2 EUGENE, OR 97408 (541) 556-44252206 COUNTRY HAVEN DRE R IC J. F A V R E A USEP. 12 , 2 0 1 7OREGONREGISTERED PROFES S I ONALE N G I NEER DATE: 11/26/24 TL: 17-03-36-24 LOT: 03300 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 10 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSDSDSDSDSDSDSDSDSDSDSDSDSDSDEX SD17TH STEX 12'APPROACH28' PAVE 40' ROW TL 3300 TL 3200 TL 3400 TL 2000 TL 2100 ±2.5'OHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWTREE TO BE REMOVED SPRINGFIELD, OR 97477503 17TH STSITE ASSESSMENTNO.APPROVED:DESCRIPTIONREVISIONSBYDATE503 17TH ST SPRINGFIELD, OR 97477 TL 17-03-36-24-03300 SIZE: 0.23 ACRES APPLICANT: GS ENTERPRISES OREGON LLC (541) 852-2312 APPLICANT'S REPRESENTATIVE: FAVREAU ENGINEERING 2206 COUNTRY HAVEN DR EUGENE, OR 97408 (541) 556-4425 PROPERTY INFO SHEET C1 EUGENE, OR 97408 (541) 556-44252206 COUNTRY HAVEN DRE R IC J. F A V R E A USEP. 12 , 2 0 1 7OREGONREGISTERED PROFES S I ONALE N G I NEER DATE: 10/3/24 TL: 17-03-36-24 LOT: 03300 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 10 SITE NO SCALE VICINITY MAP LEGEND THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS AND THE CITY OF SPRINGFIELD. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND INDEMNIFY AND HOLD DESIGN PROFESSIONALS HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. ANY ESTIMATED QUANTITIES HEREON ARE ONLY FOR THE PURPOSE OF OBTAINING THE NECESSARY PERMITS, AND FAVREAU ENGINEERING, LLC DOES NOT GUARANTEE THE ACCURACY OF THE ESTIMATED QUANTITIES. THE CONTRACTOR SHALL PERFORM HIS OWN QUANTITY TAKEOFF BEFORE SUBMITTING A BID FOR ANY PORTION OF THE IMPROVEMENTS COVERED BY THESE PLANS. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS INCLUDING POTHOLING AND LOCATING EXISTING UNDERGROUND UTILITIES AND SHALL REPORT DISCREPANCIES TO THE ENGINEER PRIOR TO COMMENCEMENT OF WORK. THIS DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE EXISTING PUBLIC SANITARY SEWERSS PROPERTY BOUNDARY ENGINEER'S NOTE NOTICE TO CONTRACTOR SOIL TYPE 96 - NEWBERG LOAM, SOIL GROUP A - WELL-DRAINED FEMA THE SITE IS LOCATED IN ZONE "X" AS SHOWN ON FIRM COMMUNITY PANEL NO. 41039C1142F, DATED JUNE 2, 1999. NO BASE FLOOD ELEVATION DETERMINED. WELLHEAD PROTECTION THE SUBJECT SITE IS WITHIN THE 20-YEAR TIME OF TRAVEL ZONE, PER CITY MAPPING. EXISTING PUBLIC STORM DRAINSD EXISTING OHVERHEAD WIRE EXISTING TREE OHW