Loading...
HomeMy WebLinkAboutPlans Applicant 10/17/2024LAM STOCK#1 PLANING MILLSAWMILL "B"WAREHOUSEWHSE OB-4OB-3STORAGE YARDWATER TOWERFUEL BINSAWMILL "A"CENTRAL BARKINGPOND(LAM PLANT)SHED #2CRANELAMINATING PLANT21st STREETEVAPORATION #2 PLANING MILLOB-2Main STWAREHOUSE#3 PLANING MILLOVERHEAD UTILITIESOVERHEAD UTILITIESOVERHEAD UTILITIESHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTFORMERVENEER PLANT21st STREETENTRANCE#4 PLANER MILL#4 GLULAM PLANTWHSE OFFICEOB-1PLANTSERV.BOILERHOUSE28th STENTRANCEGREEN SORTERLOG TRUCKENTRANCENOPARKINGNO PARKING NOPARKING NOPARKINGNOPARKINGNOPARKINGNO PARKING NOPARKINGNOPARKINGNOPARKINGNOPARKINGNO PARKING Prel im inary -Not forConstructionPROJECT:23101REVISIONS:CHECKED:wilson-architecture.com | 541-912-0878Springfield Plant ImprovementsRosboroPermit ApplicationDATE: 05.15.2024CW1Site PlanOverallSite Plan - OverallVEHICLE PARKING SUMMARYTOTAL VEHICLE PARKING - CAMPUSA001200'100'50'0'1" = 100'EXISTING319NEW10TOTAL329ACCESSIBLE PARKING PER OSSC TABLE 1106.2 -CAMPUS WIDEEXISTING3RESTRIPED4NEW2TOTAL PROVIDED9REQUIRED8COVERED BIKE PARKING - CAMPUSEXISTING82Accessible Parking PlanOB1 South1/8" = 1'-0"3Accessible Parking PlanOB4 East1/8" = 1'-0"4Accessible Parking PlanOB4 South1/8" = 1'-0"5Accessible Parking PlanOB2 South1/8" = 1'-0"6Accessible Parking PlanGlulam Building East1/8" = 1'-0"ACCESSIBLE PARKING - KEYNOTES1.SEE FIGURE 1 OF REFERENCE STANDARD FOR ADDITIONALINFORMATION.2.SEE FIGURE 2 OF REFERENCE STANDARD FOR ADDITIONALINFORMATION.3.SEE FIGURE 4 OF REFERENCE STANDARD FOR ADDITIONALINFORMATION.4.SIGN R7-8 "RESERVED PARKING". SEE FIGURE 8 OFREFERENCE STANDARD FOR ADDITIONAL INFORMATION.5.SIGNS R7-8 "RESERVED PARKING" OVER SIGN R7-8P "VANACCESSIBLE". SEE FIGURE 9 OF REFERENCE STANDARD FORADDITIONAL INFORMATION.6.SIGNS R7-8 "RESERVED PARKING" OVER SIGN O0R7-8C"WHEELCHAIR USER ONLY". SEE FIGURE 10 OF REFERENCESTANDARD FOR ADDITIONAL INFORMATION.7.PAVEMENT MARKING, 4" WHITE.8.LOCATE NEW PAVEMENT MARKING LINE AT EXISTINGPAVEMENT MARKING.9.ACCESS AISLE. SEE FIGURE 1 OF REFERENCED STANDARDFOR LINE SPACING AND LAYOUT.10.PAVEMENT MARKINGS TO DEFINE ACCESSIBLE ROUTE FROMACCESS AISLE TO ENTRANCE AT DRIVING SURFACE.11.INTERNATIONAL SYMBOL OF ACCESSIBLE. SEE FIGURE 6 OFREFERENCED STANDARD.12."NO PARKING" PAVEMENT MARKING. SEE FIGURE 7 OFREFERENCED STANDARD.13.WHEEL STOP.14.SLOPE OF EXISTING PAVEMENT SLOPES LESS THAN 2% INALL DIRECTIONS. PAVEMENT TO REMAIN.15.EXISTING CURB CUT TO REMAIN.16.EXISTING PARKING MARKING TO REMAIN.17.CARPORT ROOF STRUCTURE SUPPORT TO REMAIN.18.BUILDING ENTRANCE.ACCESSIBLE PARKING - GENERAL NOTESa.PARKING STALL AND SIGN STANDARDS REFERENCED HEREPER OREGON TRANSPORTATION COMMISSION STANDARDSFOR ACCESSIBLE PARKING SPACES, AUGUST 2018.2A0013A001OB1OB2GLULAMBUILDINGOB4OB4CARPORT#2121334WALLMOUNT4POSTMOUNT6POSTMOUNT5WALLMOUNT5WALLMOUNT5POSTMOUNT5POSTMOUNT4WALLMOUNT18'-0"9'-0"9'-0"3'-6"9'-0"±9'-0"9'-0"18'-0"18'-0"9'-0"8'-0"9'-0"5'-6"6'-0"9'-0"18'-0"5'-8"18'-0"4'-0"9'-0"8'-0"7TYP7TYP7TYP7TYP7TYPNOTE: SEE CIVIL DRAWINGS INSITE IMPROVEMENT PACKAGEFOR LOCATION OF PARKINGAREA RELATIVE TO BUILDING.ALIGNALIGNALIGN888999910111111111111111112121212121213141414141516TYP16TYP16TYP17TYP1818181818EVCHARGINGSTATION TOSOUTHERNTWO SPACES5A0016A0014A00106.15.2024 /4 A141 /2A141/1 A141 /3 A141 A A B D F 1 2 13 3 4 5 6 7 9 8 10 11 12 J L L N Q R T V VCEMPSU 19'-9"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"21'-0"30'-0"23'-10 1/2"23'-7 1/2"6'-3"31'-0"19'-7 1/2"18'-10"18'-8"36'-8"14'-10"15'-4 1/2" 208'-9" 8'16' 32'0 1/16" = 1'-0" 1 A151 2 A151 6'-0" G K P1.1 P1.2 P1.3 P1.5 P1.8 P1.9 P1.10P1.11 P1.12 P1.13 7'-7"BIKE STORAGE PLANER BUILDING P1 A119.1 1 2 A119.1 P1.4 A119.2 1 AIR COMPRESSOR & DRYER ROOM 119 SHOP 112 EYE WASH 111 8'-0" 1'-6"1'-6"8"2'-10"4'-1"15'-9"14'-7 1/2"1'-8"2'-1"3'-4" 8'-7"29'-0"21'-10 1/2"22'-3"22'-8"21'-0"21'-0"21'-0"21'-0"20'-4 1/2"6"B.L.B.L.Building Line (B.L.)B.L.6"6'-0"8'-0"4'-0"4'-0"4'-0"13'-0" SEP-1, Ref. Plumbing P1.6 P1.7 2'-0"2'-0"Wheel stop wall, Ref. Structural Wheel stop wall, Ref. Structural Electrical Equipment, Ref. Electrical Column Protection, Typ. by Owner Cast in place bollards at exterior openings, typ. FIRE RISER 121EB6.16W111'-0"MODULAR DEFERRED340'-9"Preliminary equipment / platform extents for reference only, typ. 121.1 6'-0"8'-0"11'-0"2'-0"2'-0"EB6.16W1120.1 FIRE RISER 120 2 A161 0 1 28'-1 5/8"4'-3"13'-4 1/2"4'-3"Planer motor base pedestal, Ref. Structural 01 4'-2" Embedded beam, Ref. Structural 01 Door opening, typ 01 GENERAL NOTES - FLOOR PLAN a. SEE SHEET A160 FOR WALL ASSEMBLIES. b.EXTENTS OF EQUIPMENT PLATFORM WILL BE DEFERRED SUBMITTAL. c."MODULAR DEFERRED" REFERS TO MODULAR UNITS BY OWNER TO BE SUBMITTED FOR PERMIT AS A DEFERRED SUBMITTAL. WALL LEGEND - FLOOR PLAN NEW WALL -THERMAL INSULATION NEW WALL -ACOUSTICAL INSULATION NEW WALL -NO INSULATION NEW WALL -PEMB EXTERIOR ASSEMBLY CHECKED: wilson-architecture.com | 541-912-0878 DATE: PROJECT: REVISIONS:05.29.2024 23101 CW A111 OVERALL PLAN -FIRST FLOOR Planer Mill ROSBORO PLANT ROSBORO BID AND PERMIT SET 1Floor Plan First Floor REVISIONS DATE # DESCRIPTION 08/28/2024 01 PLN-REV-01 PLN-REV-01 -08.28.2024 FE FEFEFEFE FE FE FE FE FE FE FE FE FE FEFEC FE FE FEC FE H H800x2050 H 800x2050 H STRAPPER BUNDLE CUT SAW PAPER FEEDER 800x2050H H 561 428 800x2050 HH 800x2050 HH HH 800x2050 HH800x2050800x2050HHH 800x2050 H 800x2050 H H H 800 x20 50 HLINEBAREXHAUST EXHAUST FRESHWORK DIRECTIONPO WE R INPUTELECTRIC CABINETMOBILE PLA TFORMFOR BELT CHANGEPO WE R INPUTELECTRIC CABINETLRLEFT(L) OR RIGHT (R) FIXED SIDEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEELECTRIC CABINETPO WE R INPUTRLLEFT (L) OR RIGHT (R) FIXED SIDEBEAM OUTFEED FRONT BENCH FLOOR SUMP SANITARY WASH BASIN BENCH WH GENERAL NOTES - FLOOR PLAN /3 A240 /1A240/2 A240 /4 A240 1 1 8 8 21 22 A U R P K L G E C 30'-0"20'-0"24'-0"22'-0"30'-0"30'-0"30'-0"19'-0"16'-6"25'-0"25'-0"18'-6"6'-6" 6" 29'-6"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"25'-0"21'-0"31'-4"31'-4"31'-4"28'-9" 23 24 25 26 27 28 29 200'-0"470'-0" W 23'-0"30 31 32 33 34 35 36 38 T 10' 20' 40'0 1" = 20'-0" 52 2 19 1511 11 3 3 4 7 6 17 1 A251 MEETING / OFFICE OFFICE OFFICE OFFICE FD FD FD WASH STATION Cast in place bollards at exterior openings, typ.1'-0"GLULAM BUILDING G1 G1.9G1.8G1.7G1.6G1.5G1.4 G1.3 G1.2G1.1 G1.19 G1.18 G1.17 G1.16 G1.15 G1.14 G1.13 G1.12 G1.11 2 A251 63'-6"SHOP 113 110.1 BREAK AREA 101 G1.10 G1.20 A219.1 1 QC LAB 104 DISPLAY AND LOBBY 100 A219.3 1 A219.2 1 A219.4 1 37 1'-3" 28'-9" 6" 20 20 18'-0"6'-10"24'-0"3'-8" 8'-5"15'-0"15'-0" 4'-2"EQ EQ 6'-10" 3'-8" 13'-2"13'-2" 3'-0"EQ EQ3'-0" 18 13'-6" 13 85'-0"6'-6" 7'-7" 17'-0" 17'-0" 6'-6"18'-6"25'-0"25'-0"16'-6" 22'-6" 1614 22'-6" 5'-10" SUPPLIES 111 GRINDING 112 FD FIRE RISER 1 131 FIRE RISER 2 132 IT 106 JANITOR 105 6'-0"AIR COMPRESSOR 124 6'-0"8'-0"11'-0"6'-0"12'-6"20'-0"3-TON CRANE 3-TON CRANE Column Protection, Typ. by Owner FIRE RISER 3 133 FIRE RISER 4 134 FIRE RISER 5 135 111.1 112.1 FD 113.1 RR 5 109 TOTES & RESIN 11014'-6"13'-7"36" High Curb WH 124.1 124.2 124.3 A219.2 3 FD RR 3 107 RR 4 108 110'-0"PARTS 120 130.1131.1132.1 133.1134.1 120.1 Louver, Ref. Mech.1'-0"230'-0"BIKE STORAGE WALL LEGEND - FLOOR PLAN NEW WALL -THERMAL INSULATION NEW WALL -ACOUSTICAL INSULATION NEW WALL -NO INSULATION NEW WALL -PEMB EXTERIOR ASSEMBLY CHECKED: wilson-architecture.com | 541-912-0878 DATE: PROJECT: REVISIONS:09.10.2024 23101 CW A211 OVERALL PLAN -FIRST FLOOR Glulam Building ROSBORO PLANT ROSBORO BID AND PERMIT SET First Floor 1Floor Plan