HomeMy WebLinkAboutPlans Applicant 10/17/2024LAM STOCK#1 PLANING MILLSAWMILL "B"WAREHOUSEWHSE OB-4OB-3STORAGE YARDWATER TOWERFUEL BINSAWMILL "A"CENTRAL BARKINGPOND(LAM PLANT)SHED #2CRANELAMINATING PLANT21st STREETEVAPORATION
#2 PLANING MILLOB-2Main STWAREHOUSE#3 PLANING MILLOVERHEAD UTILITIESOVERHEAD UTILITIESOVERHEAD UTILITIESHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTHYDRANTFORMERVENEER PLANT21st STREETENTRANCE#4 PLANER MILL#4 GLULAM PLANTWHSE
OFFICEOB-1PLANTSERV.BOILERHOUSE28th STENTRANCEGREEN SORTERLOG TRUCKENTRANCENOPARKINGNO
PARKING
NOPARKING NOPARKINGNOPARKINGNOPARKINGNO
PARKING
NOPARKINGNOPARKINGNOPARKINGNOPARKINGNO
PARKING
Prel
im
inary
-Not forConstructionPROJECT:23101REVISIONS:CHECKED:wilson-architecture.com | 541-912-0878Springfield Plant ImprovementsRosboroPermit ApplicationDATE: 05.15.2024CW1Site PlanOverallSite Plan - OverallVEHICLE PARKING SUMMARYTOTAL VEHICLE PARKING - CAMPUSA001200'100'50'0'1" = 100'EXISTING319NEW10TOTAL329ACCESSIBLE PARKING PER OSSC TABLE 1106.2 -CAMPUS WIDEEXISTING3RESTRIPED4NEW2TOTAL PROVIDED9REQUIRED8COVERED BIKE PARKING - CAMPUSEXISTING82Accessible Parking PlanOB1 South1/8" = 1'-0"3Accessible Parking PlanOB4 East1/8" = 1'-0"4Accessible Parking PlanOB4 South1/8" = 1'-0"5Accessible Parking PlanOB2 South1/8" = 1'-0"6Accessible Parking PlanGlulam Building East1/8" = 1'-0"ACCESSIBLE PARKING - KEYNOTES1.SEE FIGURE 1 OF REFERENCE STANDARD FOR ADDITIONALINFORMATION.2.SEE FIGURE 2 OF REFERENCE STANDARD FOR ADDITIONALINFORMATION.3.SEE FIGURE 4 OF REFERENCE STANDARD FOR ADDITIONALINFORMATION.4.SIGN R7-8 "RESERVED PARKING". SEE FIGURE 8 OFREFERENCE STANDARD FOR ADDITIONAL INFORMATION.5.SIGNS R7-8 "RESERVED PARKING" OVER SIGN R7-8P "VANACCESSIBLE". SEE FIGURE 9 OF REFERENCE STANDARD FORADDITIONAL INFORMATION.6.SIGNS R7-8 "RESERVED PARKING" OVER SIGN O0R7-8C"WHEELCHAIR USER ONLY". SEE FIGURE 10 OF REFERENCESTANDARD FOR ADDITIONAL INFORMATION.7.PAVEMENT MARKING, 4" WHITE.8.LOCATE NEW PAVEMENT MARKING LINE AT EXISTINGPAVEMENT MARKING.9.ACCESS AISLE. SEE FIGURE 1 OF REFERENCED STANDARDFOR LINE SPACING AND LAYOUT.10.PAVEMENT MARKINGS TO DEFINE ACCESSIBLE ROUTE FROMACCESS AISLE TO ENTRANCE AT DRIVING SURFACE.11.INTERNATIONAL SYMBOL OF ACCESSIBLE. SEE FIGURE 6 OFREFERENCED STANDARD.12."NO PARKING" PAVEMENT MARKING. SEE FIGURE 7 OFREFERENCED STANDARD.13.WHEEL STOP.14.SLOPE OF EXISTING PAVEMENT SLOPES LESS THAN 2% INALL DIRECTIONS. PAVEMENT TO REMAIN.15.EXISTING CURB CUT TO REMAIN.16.EXISTING PARKING MARKING TO REMAIN.17.CARPORT ROOF STRUCTURE SUPPORT TO REMAIN.18.BUILDING ENTRANCE.ACCESSIBLE PARKING - GENERAL NOTESa.PARKING STALL AND SIGN STANDARDS REFERENCED HEREPER OREGON TRANSPORTATION COMMISSION STANDARDSFOR ACCESSIBLE PARKING SPACES, AUGUST 2018.2A0013A001OB1OB2GLULAMBUILDINGOB4OB4CARPORT#2121334WALLMOUNT4POSTMOUNT6POSTMOUNT5WALLMOUNT5WALLMOUNT5POSTMOUNT5POSTMOUNT4WALLMOUNT18'-0"9'-0"9'-0"3'-6"9'-0"±9'-0"9'-0"18'-0"18'-0"9'-0"8'-0"9'-0"5'-6"6'-0"9'-0"18'-0"5'-8"18'-0"4'-0"9'-0"8'-0"7TYP7TYP7TYP7TYP7TYPNOTE: SEE CIVIL DRAWINGS INSITE IMPROVEMENT PACKAGEFOR LOCATION OF PARKINGAREA RELATIVE TO BUILDING.ALIGNALIGNALIGN888999910111111111111111112121212121213141414141516TYP16TYP16TYP17TYP1818181818EVCHARGINGSTATION TOSOUTHERNTWO SPACES5A0016A0014A00106.15.2024
/4 A141 /2A141/1 A141
/3 A141
A
A
B D
F
1
2
13
3
4
5
6
7
9
8
10
11
12
J L
L
N Q R T V
VCEMPSU
19'-9"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"21'-0"30'-0"23'-10 1/2"23'-7 1/2"6'-3"31'-0"19'-7 1/2"18'-10"18'-8"36'-8"14'-10"15'-4 1/2"
208'-9"
8'16' 32'0
1/16" = 1'-0"
1
A151
2
A151
6'-0"
G
K
P1.1 P1.2 P1.3
P1.5
P1.8
P1.9
P1.10P1.11
P1.12
P1.13 7'-7"BIKE
STORAGE
PLANER BUILDING
P1
A119.1
1
2
A119.1
P1.4
A119.2
1
AIR COMPRESSOR &
DRYER ROOM
119
SHOP
112
EYE WASH
111
8'-0"
1'-6"1'-6"8"2'-10"4'-1"15'-9"14'-7 1/2"1'-8"2'-1"3'-4"
8'-7"29'-0"21'-10 1/2"22'-3"22'-8"21'-0"21'-0"21'-0"21'-0"20'-4 1/2"6"B.L.B.L.Building Line (B.L.)B.L.6"6'-0"8'-0"4'-0"4'-0"4'-0"13'-0"
SEP-1, Ref. Plumbing
P1.6
P1.7
2'-0"2'-0"Wheel stop wall,
Ref. Structural
Wheel stop wall, Ref. Structural
Electrical Equipment, Ref. Electrical
Column Protection, Typ.
by Owner
Cast in place
bollards at
exterior
openings, typ.
FIRE RISER
121EB6.16W111'-0"MODULAR
DEFERRED340'-9"Preliminary equipment /
platform extents for
reference only, typ.
121.1
6'-0"8'-0"11'-0"2'-0"2'-0"EB6.16W1120.1
FIRE RISER
120
2
A161
0 1
28'-1 5/8"4'-3"13'-4 1/2"4'-3"Planer motor base
pedestal, Ref. Structural
01
4'-2"
Embedded beam,
Ref. Structural
01
Door opening, typ
01
GENERAL NOTES - FLOOR PLAN
a. SEE SHEET A160 FOR WALL ASSEMBLIES.
b.EXTENTS OF EQUIPMENT PLATFORM WILL BE
DEFERRED SUBMITTAL.
c."MODULAR DEFERRED" REFERS TO MODULAR UNITS
BY OWNER TO BE SUBMITTED FOR PERMIT AS A
DEFERRED SUBMITTAL.
WALL LEGEND - FLOOR PLAN
NEW WALL -THERMAL INSULATION
NEW WALL -ACOUSTICAL INSULATION
NEW WALL -NO INSULATION
NEW WALL -PEMB EXTERIOR ASSEMBLY
CHECKED:
wilson-architecture.com | 541-912-0878
DATE:
PROJECT:
REVISIONS:05.29.2024
23101
CW A111
OVERALL PLAN -FIRST FLOOR
Planer Mill
ROSBORO PLANT
ROSBORO
BID AND PERMIT SET
1Floor Plan
First Floor
REVISIONS
DATE # DESCRIPTION
08/28/2024 01 PLN-REV-01
PLN-REV-01 -08.28.2024
FE
FEFEFEFE
FE
FE
FE
FE FE FE FE
FE
FE
FEFEC FE
FE
FEC
FE
H H800x2050
H
800x2050
H
STRAPPER
BUNDLE
CUT SAW
PAPER
FEEDER
800x2050H H
561
428
800x2050 HH
800x2050 HH
HH
800x2050
HH800x2050800x2050HHH
800x2050
H
800x2050
H
H
H 800 x20 50 HLINEBAREXHAUST
EXHAUST
FRESHWORK DIRECTIONPO WE R INPUTELECTRIC CABINETMOBILE PLA TFORMFOR BELT CHANGEPO WE R INPUTELECTRIC CABINETLRLEFT(L) OR RIGHT (R) FIXED SIDEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEFIXE D PLATFORMFOR BELT CHANGEELECTRIC CABINETPO WE R INPUTRLLEFT (L) OR RIGHT (R) FIXED SIDEBEAM OUTFEED
FRONT
BENCH
FLOOR SUMP
SANITARY
WASH BASIN
BENCH
WH
GENERAL NOTES - FLOOR PLAN
/3 A240 /1A240/2 A240
/4 A240
1
1
8
8 21 22
A
U
R
P
K
L
G
E
C
30'-0"20'-0"24'-0"22'-0"30'-0"30'-0"30'-0"19'-0"16'-6"25'-0"25'-0"18'-6"6'-6"
6"
29'-6"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"25'-0"21'-0"31'-4"31'-4"31'-4"28'-9"
23 24 25 26 27 28 29
200'-0"470'-0"
W 23'-0"30 31 32 33 34 35 36 38
T
10' 20' 40'0
1" = 20'-0"
52
2 19
1511
11
3
3 4
7
6 17
1
A251
MEETING / OFFICE
OFFICE OFFICE
OFFICE
FD
FD
FD
WASH
STATION
Cast in place bollards at
exterior openings, typ.1'-0"GLULAM
BUILDING
G1
G1.9G1.8G1.7G1.6G1.5G1.4
G1.3
G1.2G1.1
G1.19
G1.18
G1.17
G1.16 G1.15 G1.14 G1.13 G1.12
G1.11
2
A251
63'-6"SHOP
113
110.1
BREAK AREA
101
G1.10
G1.20
A219.1
1
QC LAB
104
DISPLAY AND
LOBBY
100
A219.3
1
A219.2
1
A219.4
1
37
1'-3"
28'-9"
6"
20
20
18'-0"6'-10"24'-0"3'-8"
8'-5"15'-0"15'-0"
4'-2"EQ EQ 6'-10"
3'-8"
13'-2"13'-2"
3'-0"EQ EQ3'-0"
18
13'-6"
13
85'-0"6'-6"
7'-7"
17'-0"
17'-0"
6'-6"18'-6"25'-0"25'-0"16'-6"
22'-6"
1614
22'-6"
5'-10"
SUPPLIES
111
GRINDING
112
FD
FIRE RISER 1
131
FIRE RISER 2
132
IT
106
JANITOR
105
6'-0"AIR COMPRESSOR
124
6'-0"8'-0"11'-0"6'-0"12'-6"20'-0"3-TON CRANE 3-TON CRANE
Column Protection, Typ.
by Owner
FIRE RISER 3
133
FIRE RISER 4
134
FIRE RISER 5
135
111.1 112.1
FD
113.1
RR 5
109
TOTES & RESIN
11014'-6"13'-7"36" High Curb
WH
124.1
124.2
124.3
A219.2
3
FD
RR 3
107
RR 4
108
110'-0"PARTS
120
130.1131.1132.1
133.1134.1
120.1
Louver, Ref.
Mech.1'-0"230'-0"BIKE
STORAGE
WALL LEGEND - FLOOR PLAN
NEW WALL -THERMAL INSULATION
NEW WALL -ACOUSTICAL INSULATION
NEW WALL -NO INSULATION
NEW WALL -PEMB EXTERIOR ASSEMBLY
CHECKED:
wilson-architecture.com | 541-912-0878
DATE:
PROJECT:
REVISIONS:09.10.2024
23101
CW A211
OVERALL PLAN -FIRST FLOOR
Glulam Building
ROSBORO PLANT
ROSBORO
BID AND PERMIT SET
First Floor 1Floor Plan