Loading...
HomeMy WebLinkAboutPlans Applicant 4/18/2024a r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024EXISTINGCONDITIONSC0.10ALTA SURVEY1 SITE ASSESSMENT OF EXISTING CONDITIONS NOTES20 Y E A R T O T Z 99 YEAR TOTZ a r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024CIVIL GENERALNOTES, LEGEND,AND DETAILSC1.11GENERAL NOTES:EXISTING TOPOGRAPHIC INFORMATION:"TOPOGRAPHIC SURVEY FOR ROUSE PROPERTIES"ATTENTION:CIVIL SYMBOLS AND ABBREVIATIONS LISTSYMBOLABBR.DESCRIPTIONIRRIRRIRRISISISGGGSPSPSPSPSP SC SC SCLMTSYMBOLABBR.DESCRIPTIONADADDDCOVCOBWBFPBFPMPIBOABBR.DESCRIPTIONC-50010C-500A22AABBR.DESCRIPTIONNO SCALECLEANOUT (CO)2NO SCALETRENCHING & BACKFILL SECTIONATYPICALNO SCALEOVERFLOW CATCH BASIN (OFCB)3NO SCALESANITARY SEWER AREA DRAIN4NO SCALETRENCH DRAIN (TD)5℄IN-LINE SEDIMENT TRAP SECTIONTRENCH DRAIN SECTION℄NO SCALELATERAL CONNECTION1℄ a r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024CIVIL DETAILSC1.12NO SCALEFLOW ENTRANCE AND ROCK SPLASH PAD5CURB AND GUTTERNO SCALESTORMWATER PLANTER WALL2 NO SCALESTORMWATER PLANTER CURB OPENING3 AASECTION A-ATYPICAL CONDITION AT PEDESTRIAN PAVEMENTSNO SCALESTORWATER RAIN GARDEN1TYPICAL EAST SIDETYPICAL SOUTH AND EAST SIDESSECTION A-ATYPICAL CONDITION AT CURB AND GUTTERBBPLANSECTION B-BELEVATIONNO SCALEFLOW ENTRANCE, ROCK CHANNEL, AND SPLASH PAD4PEDESTRIAN PAVEMENT a r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024CIVIL DETAILSC1.131A: STANDARD CURB AND GUTTER1B: REVERSE CURB AND GUTTERTYPICAL GRADINGDESIGNATIONS PER PLAN1C: CURB AND GUTTER WITH THICKENED EDGE WALKTYPICAL JOINTINGNO SCALECURB AND GUTTER1 NO SCALEFULL DEPTH CURB3 DEAD-END JOINT CONDITIONSTRUCTURE CORNER CONDITIONNO SCALEDEAD-END JOINTS AND STRUCTURE CORNERS8EXTRA REINFORCEMENT ATJ3J5J4J8J7J1J2J6NO SCALEJOINTING DETAILS4NO SCALEAND SEALANT DETAIL9JOINT EDGINGCONTRACTION /CONSTRUCTION JOINTISOLATION JOINT AT BUILDINGS ORBUILDING APRONS,···ISOLATION JOINT ATUTILITY STRUCTURES AND CURBSSTANDARD SECTION (NO CURB)STANDARD SECTION (CURB)NO SCALESAWCUT SECTIONS5NO SCALEMILL AND INLAY SECTION62A: FLUSH PAVEMENT/SIDEWALK2B: CURBED CONDITIONNO SCALETHICKENED EDGE SIDEWALK2NO SCALEPRECAST CONCRETE WHEELSTOP7 a r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024CIVIL DETAILSC1.14NO SCALE PAVEMENT MARKINGS2ACCESSIBLE PARKING℄NO SCALESIGN POST AND BASE1FLUSH PAVEMENT CONDITIONCURB/SIDEWALK CONDITIONS1AS1BRESERVEDPARKINGNOPARKINGACCESS ISLES1CVANACCESSIBLERESERVEDPARKINGWHEELCHAIRUSER ONLY COCOKOHL'SFORMERSEARS1C4B1AP1AP1BP2BP2C1A56E3E1BE2E1AE1BL2L1IL1A2A4A384A4C4CJ8J1J8J1J4J4J272B2B2A2B3E24D4DE5E5E4P2APROPOSED RENOVATED MALL SPACEFOR NEW TENANTMALLENTRANCEMALL SPACEJ8HHHH H HHHHHHHHHHHHHCCCNORTHC2.111C2.112SOUTHC2.111WESTC2.111GATEWAY ST.MALLCOCOFORMERSEARSS1AS1CS1CS1AS1CS1BM2M1M2NO PARKING NO PARKINGNO PARKIN G NO PARKIN G M3M3M4M5M5M5ME1ME1FOR NEW TENANTa r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024C2.11SITE MATERIALS PLAN - NORTH1 00PLAN SCALE10'20'SCALE: 1"=10'PAVEMENT LEGENDP1AP1BP2BL1P2ASHEET NOTESPAVEMENT MARKING AND SIGNAGE PLAN - NORTH200PLAN SCALE10'20'SCALE: 1"=10'CONSTRUCTION NOTESSIGNAGE AND STRIPING NOTES L2CONCRETE PAVEMENT - SPECIALTY FINISHCONCRETE PAVEMENT - STANDARD FINISHASPHALT PAVEMENT - FULL DEPTH / DRIVE LANEP2CASPHALT PAVEMENT - MILL AND INLAYASPHALT PAVEMENT - FULL DEPTH / PARKINGLANDSCAPE AREASTORMWATER FACILITYKEYMAP SITEMATERIALS PLANNORTH HHHH H HHHHHHHHHHHHHCCCNORTHC2.111C2.112SOUTHC2.121WESTC2.122GATEWAY ST.MALLKOHL'SMALLENTRANCEPROPOSED RENOVATED MALL SPACEFOR NEW TENANTEXISTING TENANT SPACE TO REMAINMALL SPACEE1AE1BP1BJ8J9A2A4A2E4IL1IL1IL1E6J8P1CJ1J4J3A D CINEMARKP2A32C21FORMER SEARSBLDGa r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024C2.12SITE MATERIALS PLAN - SOUTH1 00PLAN SCALE10'20'SCALE: 1"=10'SITE MATERIALS PLAN - WEST2 00PLAN SCALE10'20'SCALE: 1"=10'PAVEMENT LEGENDP1AP1BP2BL1P2ASHEET NOTESL2CONCRETE PAVEMENT - SPECIALTY FINISHCONCRETE PAVEMENT - STANDARD FINISHASPHALT PAVEMENT - FULL DEPTH / DRIVE LANEP2CASPHALT PAVEMENT - MILL AND INLAYASPHALT PAVEMENT - FULL DEPTH / PARKINGLANDSCAPE AREASTORMWATER FACILITYKEYMAP CONSTRUCTION NOTESSITEMATERIALS PLANSOUTH / WEST 7'-6"COCOKOHL'SFORMERSEARSPROPOSED RENOVATED MALL SPACEFOR NEW TENANTMALLENTRANCEMALL SPACEHHHH H HHHHHHHHHHHHHCCCNORTHC2.211SOUTHC2.221WESTC2.222GATEWAY ST.MALLa r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024C2.21SITE HORIZONTAL LAYOUT PLAN - NORTH1 00PLAN SCALE10'20'SCALE: 1"=10'KEYMAP SITE HORIZONTALLAYOUT PLANNORTHSHEET NOTES HHHH H HHHHHHHHHHHHHCCCNORTHC2.211SOUTHC2.221WESTC2.222GATEWAY ST.MALLKOHL'SMALLENTRANCEPROPOSED RENOVATED MALL SPACEFOR NEW TENANTEXISTING TENANT SPACE TO REMAINMALL SPACEA D TRASH ENCLOSURECINEMARK FORMER SEARSBLDGa r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024C2.22SITE HORIZONTAL LAYOUT PLAN - SOUTH1 00PLAN SCALE10'20'SCALE: 1"=10'SHEET NOTESKEYMAP SITE HORIZONTAL LAYOUT PLAN - WEST2 00PLAN SCALE10'20'SCALE: 1"=10'SITE HORIZONTALLAYOUT PLANSOUTH / WEST SDSDSDEEEFHTAP7'-6"COCO1B1A2ARRRRRRRRRRRRRR3BSDSDSD3A3SS MHRIM EL= 436.54'8" IE E = 426.84'8" IE W = 426.86'6" IE N = 431.14'AD4HHHH H HHHHHHHHHHHHHCCCNORTHC3.111SOUTHC3.112WESTC3.113GATEWAY ST.MALLa r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024SITE GRADINGPLANC3.11GRADING PLAN - NORTH1 00PLAN SCALE10'20'SCALE: 1"=10'GRADING PLAN - SOUTH2 00PLAN SCALE10'20'SCALE: 1"=10'KOHL'SKOHL'SFORMERSEARSSHEET NOTESGRADING PLAN LEGENDRRR456.25TCONCCONSTRUCTION NOTESGRADING PLAN - WEST3 00PLAN SCALE10'20'SCALE: 1"=10'CINEMARKKEYMAP WWGGSSSSSSSSSSSSSSSSSSSSW SSSSSSSSSSSSSSSSBUILDINGGGGGGGGGGGWW W W W W W W W W GGGGGGGGGGWWWWWWWWEEEFHTAPCOCO834E1E4E4E1E3E5FORMERSEARSKOHL'S4C4B4D4B225E18255SSSSSSSSSSSSSS MHRIM EL= 436.54'8" IE E = 426.84'8" IE W = 426.86'6" IE N = 431.14'ADE36111HHHH H HHHHHHHHHHHHHCCCNORTHC4.121SOUTHC4.112WESTC4.113GATEWAY ST.MALLa r c h i t e c t u r e + p l a n n i n gISSUANCE NAMEDATER E T A I L P A R T N E R S GATEWAY CENTER 3000 GATEWAY STREET SPRINGFIELD, OR 97477 PROJECT NUMBER: 17-045 NORTH MALL RENOVATION 11611 SAN VICENTE BOULEVARD, SUITE 900 LOS ANGELES, CA 90049MDS LAND USE 04/12/2024SITE UTILITIESPLANC4.11VEGETATED STORMWATER FACILITYSTORMWATER LEGENDCONSTRUCTION NOTESRUNOFF FLOW DIRECTIONUTILITY PLAN - NORTH1 00PLAN SCALE10'20'SCALE: 1"=10'UTILITY PLAN - SOUTH2 00PLAN SCALE10'20'SCALE: 1"=10'UTILITY PLAN - WEST3 00PLAN SCALE10'20'SCALE: 1"=10'KEYMAP SHEET NOTES Date:EXPIRES: JUN. 30, 202416947PEOREGONNALT EREDPROFESSIONGE INEERNOV.16,1993LGCK E REG IG SR EYSCHORNA1LANDSCAPE LIGHTING PLAN - NORTHSCALE: 3/32" = 1'-0"NEW TO EXISTING CONNECTIONLEGENDENEXISTINGNEW WORK2LANDSCAPE LIGHTING PLAN - SOUTHSCALE: 3/32" = 1'-0"1111ISSUANCECITY SUBMITTAL DEMODATER E T A I L P A R T N E R S LOS ANGELES, CA 90049 11611 SAN VICENTE BOULEVARD, SUITE 900 NORTH MALL RENOVATION PROJECT NUMBER: 17-045 SPRINGFIELD, OR 97477 3000 GATEWAY STREET GATEWAY CENTER 220888SE JOB#:New YorkOmahaHonoluluMiamiLos AngelesSeattle12/06/2023PC SUBMITTAL02/15/2024 1 2ND PC SUBMITTAL04/11/2024LANDSCAPELIGHTING PLANE1.05GENERAL ELECTRICAL EXISTING CONDITIONS NOTESA. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO TIE OWNER.B. VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS AGAINST TIE CONTRACT DOCUMENTS, AND BECOME FAMILIAR WITH THE WORN PRIOR TO BIDDING AND START OF THE WORK. SIGNING TIE CONTRACT IS AN ACKNOWLEDGEMENT THAT THE SITE VISIT HAS BEEN COMPLETED AND THE EXISTING CONDITIONS ARE ACCEPTED.C. DEMOLISH ANY EXISTING EQUIPMENT, DEVICES, AID LUMINAIRES AS INDICATED AND/OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF TIE NEW WORK. REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, CONDUITS,SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE TIE NEW WORK.D. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM TIE ITEM TO BE DEMOLISHED TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AID SHALL BE CUT OR CHISELED AT LEAST 2” INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH.E. THE OWNER SHALL HAVE SALVAGE RIGHTS TO ANY ITEMS THAT ARE TO BE DEMOLISHED. THOSE ITEMS THAT THE OWNER WISHES TO SALVAGE SHALL BE CAREFULLY REMOVED AND STORED IN A LOCATION AS DIRECTED BY THE OWNER.ALL OTHER ITEMS OF DEMOLITION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE.F. PROVIDE TEMPORARY CIRCUITS AND CONNECTIONS TO EQUIPMENT, LUMINAIRES, OR DEVICES IN AREAS OF THE FACILITY THAT ARE TO REMAIN IN OPERATION AS REQUIRED TO MAINTAIN THOSE AREAS IN COMPLETE OPERATION.G. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REWIRED TO PROVIDE POWER TO REMAINING EQUIPMENT, DEVICES, AND LUMINAIRES THAT ARE NOT BEING REMOVED.H. PROVIDE BLANK COVERPLATES FOR EXISTING EMPTY DEVICE BOXES OR JUNCTION BOXES THAT MUST REMAIN, SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO OTHER AREAS.I. WHERE ELECTRICAL DISTRIBUTION EQUIPMENT (PANELBOARDS, SWITCHBOARDS, ETC.) IS TO BE REMOVED OR RELOCATED, ALL EXISTING CIRCUITS THAT ARE TO REMAIN SHALL BE RECONNECTED TO NEW OR RELOCATED ELECTRICAL DISTRIBUTION EQUIPMENT TO MAINTAIN THE CONTINUITY OF THOSE EXISTING CIRCUITS. INTERCEPT AND EXTEND ALL EXISTING CIRCUITS AS REQUIRED.J. REMOVE ALL ABANDONED TELECOMMUNICATIONS CABLING.K. WHERE ITEMS ARE SHOWN HATCHED, ITEMS ARE TO BE DEMOLISHED ALONG WITH THEIR ASSOCIATED BOXES, CONDUITS, CONDUCTORS, SUPPORTS, AMO HANGERS UNLESS INDICATED OTHERWISE.KEYED NOTES-1.CONNECT TO EXISTING 120V OR 277V LIGHTING CIRCUIT AMO CONTROLS FEEDING THE EXISTING BUILDING FA ADE LIGHTING IN THIS AREA. IF EXISTING CIRCUITS CANNOT ACCOMMODATE ADDITIONAL LOAD, CONNECT TO SPARE 20 AMP, SINGLE-POLE CIRCUIT BREAKER IN EXISTING 120V OR 277V PANEL FEEDING THE EXISTING BUILDING FA ADE LIGHTING IN THIS AREA. IF NO SPARE CIRCUIT BREAKER IS PRESENT, COMBINE TWO LIGHTLY LOADED CIRCUITS AMO COMECT TO NEWLY CREATED SPARE CIRCUIT BREAKER. VERIFY THAT ADDITIONAL LOAD DOES NOT EXCEED THE RATED CAPACITY FOR THE PANEL OR THE PANEL ’S ASSOCIATED FEEDERS AND OVERCURRENT PROTECTION. ROUTE CIRCUIT THROUGH LIGHTING CONTROLS CURRENTLY CONTROLLING THE EXISTING BUILDING FA ADE LIGHTING IN THIS AREA.CONNECT TO EXISTING 120V LIGHTING CIRCUIT AMO CONTROLS FEEDING THE EXISTING BUILDING FA ADE LIGHTING IN THIS AREA. IF EXISTING CIRCUITS CANNOT ACCOMMODATE ADDITIONAL LOAD, CONNECT TO SPARE 20 AMP,SINGLE-POLE CIRCUIT BREAKER IN EXISTING 120V PANEL FEEDING THE EXISTING BUILDING FA ADE LIGHTING IN THIS AREA. IF NO SPARE CIRCUIT BREAKER IS PRESENT, COMBINE TWO LIGHTLY LOADED CIRCUITS AND CONNECT TO NEWLY CREATED SPARE CIRCUIT BREAKER. VERIFY THAT ADDITIONAL LOAD DOES NOT EXCEED THE RATED CAPACITY FOR THE PANEL OR THE PANEL ’S ASSOCIATED FEEDERS AND OVERCURRENT PROTECTION. ROUTE CIRCUIT THROUGH LIGHTING CONTROLS CURRENTLY CONTROLLING THE EXISTING BUILDING FA ADE LIGHTING IN THIS AREA.2.ATHE LIGHT DISTRIBUTION FROM LUMINAIRES ”SL1”,”SL2”, ”SL3”, AND ”SL5” ARE AIMED EXCLUSIVELY DOWNWARDS. THE LIGHT DISTRIBUTION FROM LUMINAIRE ”SL4” IS CONTAINED BY OVERHANGING ARCHITECTURAL ELEMENTS OR LANDSCAPING ELEMENTS.GENERAL ELECTRICAL NOTES:A. ALL EQUIPMENT, DEVICES, AMO LUMINAIRES SHALL BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE INSTALLED. EQUIPMENT MOUNTED OUTDOORS SHALL BE NEMA JR. DEVICES MOUNTED IN DAMP OR WET LOCATIONS SHALL BE WEATHERPROOF. RECEPTACLES RATED 15- OR 20-AMPS AND 120 VOLTS WHICH ARE LOCATED IN DAMP OR WET LOCATIONS SHALL BE GFCI PROTECTED AMO EQUIPPED WITH A SUITABLE WEATHERPROOF COVERPLATE (WHILE-IN-USE IN WET LOCATIONS).B. ALL LUGS, TERMINALS, ETC. IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LISTED FOR A MINIMUM OF 75 DEGREE C CONDUCTORS. TERMINA TIONS LISTED FOR ONLY 60 DEGREE C CONDUCTORS ARE NOT PERMITTED.C. COORDINATE WITH ALL OTHER TRADES TO PROVIDE ALL CODE-REWIRED CLEARANCES AROUND ELECTRICAL CONNECTION AMO CONTROLS COMPARTMENTS IN ALL EQUIPMENT WHICH IS PROVIDED BY OTTERS AND CONNECTED BY THE ELECTRICAL CONTRACTOR SUCH AS, BUT NOT LIMITED TO, HVAC EQUIPMENT.•SHr'i\SLA©NORTH7w;L5SL5SL5/ASL1 SL1'Xf<Jr2i=»jSL4BT pSL40^SL4 0TLANDSCAPE LIGHTING PLAN - SOUTH2SCALE: 3/32” = 1-0"rdc11921 Freedom Drive, Suite 1110 Reston,VA 20190 703.668.0086rdcollaborative.comc&O PR0/> 16947PE$5/.o.Or fk/OREGON%" 16,softEXPIRES: JUN. 30, 2024Date: 04/16/2024Schnackelengineers.wwwichnackel.com800-581-0963SL4&— —SL4B^SL4^T SL4^^-________________\--JPTlT^T SL4l0f^SL4BTSL4T0T-|sL4 0TNOTE25I4tSL1SL1/ SL1 __________________- -—SL4 0TsL4ip---------------SL1?//I/ /NOTE 1A//T/7I ISL2SL2i/i\T\A/\\\\\\y\\\ \SL2SL2\\5\SL3SLL1SL1SL3 \rI>\SL4SL4^ \ SL410------------------L4^T SL4lgf SL4T0f^SL4T0T^ SL4T0T\/SL4X\/o oO\VslTbTJOSL1SL4\\SL1\AI\I///X.1 dn/LANDSCAPE LIGHTING PLAN - NORTH1SCALE: 3/32” = 1’-0”NORTHLEGENDEXISTING NEW WORKNEW TO EXISTING CONNECTIONREFER TO 1/E1.01 REFER "TO 1/il.05 4\\\\\^iREFER TO 2/E1.05 REFER "TO 1/E1-01\\\CO K \\\\\& i— #ii \ co .)?/i REFER TO 1/E1.01 REFER ~T0 1/il.05 iREFER TO 2/E1.05 REFER ~T0 1A1.01 balboa > Date:EXPIRES: JUN. 30, 202416947PEOREGONNALT EREDPROFESSIONGE INEERNOV.16,1993LGCK E REG IG SR EYSCHORNANEW TO EXISTING CONNECTIONLEGENDENEXISTINGNEW WORK2OCCUPANCY SENSOR WIRING DIAGRAMTYPICAL SINGLE-ZONE CEILING-MOUNTNOT TO SCALE200/3150AFUSESSAFETYSWITCH////4 - #1/0,#6 GROUNDIN 1 1/2"CONDUIT////4 - #1/0,#6 GROUNDIN 1 1/2"CONDUIT////4 - #1/0,#6 GROUNDIN 1 1/2"CONDUIT200/3150AFUSESSAFETYSWITCH////4 - #1/0,#6 GROUNDIN 1 1/2"CONDUIT////4 - #1/0,#6 GROUNDIN 1 1/2"CONDUIT////4 - #1/0,#6 GROUNDIN 1 1/2"CONDUIT200/3150AFUSESSAFETYSWITCH1ONE LINE DIAGRAMNOT TO SCALEPROPOSED SUBSTITUTIONS FOR LUMINAIRES THAT ARE SELECTED BY OTHERS REQUIRE THE APPROVAL OF THE INDIVIDUAL THAT SELECTED THE LUMINAIRE. B.EMERGENCY BATTERY PERFORMANCE REQUIREMENTS.AT AN EMERGENCY PANELBOARD OR CENTRAL LIGHTING INVERTER, EMERGENCY LIGHTING LUMINAIRES SHALL BE PROVIDED WITH AN EMERGENCY BATTERY. SEE THE SPECIFICATIONS FOR MINIMUMLUMINAIRE SYMBOLS THAT ARE SHOWN HALF-SHADED, OR LABELED "EM", ON THE PLAN(S) INDICATE LUMINAIRES THAT SERVE AS EMERGENCY LIGHTING. UNLESS SERVED BY A CIRCUIT ORIGINATING A.LUMINAIRE SCHEDULE GENERAL NOTES:DALI = DIGITAL ADDRESSABLE LIGHTING INTERFACEHPS = HIGH PRESSURE SODIUMELV = ELECTRONIC LOW VOLTAGE / REVERSE PHASE / TRAILING EDGEMH = METAL HALIDEMLV = MAGNETIC LOW VOLTAGE / TRIAC / FORWARD PHASE / LEADING EDGEIND = INCANDESCENTDMX = DMX512IND = INCANDESCENTCFL = COMPACT FLUORESCENTECO = LUTRON ECOSYSTEM0-10V = 0-10VFL = LINEAR FLUORESCENT3-WIRE = FLUORESCENT 3-WIRENON = NOT DIMMABLELED = LIGHT EMITTING DIODESUPPORTED DIMMING CODESLIGHT SOURCE CODESOTHERSN/ALEDWALL, SURFACE120/277SL5OTHERSN/ALEDGRADE, SURFACE120SL4OTHERSN/ALEDGRADE, SURFACE120/277SL3OTHERS24LEDSTRING LIGHT120SL2OTHERSN/ALEDGRADE, POLE120/277SL1ENGINEERN/ALEDCEILING, RECESSED120/277FENGINEERN/ALEDWALL, SURFACE120/277EOTHERSN/ALEDCEILING, SURFACE120/277DOTHERSN/ALEDCEILING, SURFACE277C8SOTHERSN/ALEDCEILING, SUSPENDED277C8OTHERSN/ALEDCEILING, SURFACE277C6SOTHERSN/ALEDCEILING, SUSPENDED277C6OTHERSN/ALEDCEILING, SURFACE277C5SOTHERSN/ALEDCEILING, SUSPENDED277C5OTHERSN/ALEDCEILING, SURFACE277C4ESOTHERSN/ALEDCEILING, SUSPENDED277C4EOTHERSN/ALEDCEILING, SUSPENDED277C4OTHERSN/ALEDCEILING, SUSPENDED120B4EOTHERSN/ALEDCEILING, SUSPENDED120B4ENGINEERN/ALEDCEILING, SUSPENDED120BEENGINEERN/ALEDCEILING, SUSPENDED120BENGINEERN/ALEDCEILING, SUSPENDED120AE2ENGINEERN/ALEDCEILING, RECESSED120AEENGINEERN/ALEDCEILING, RECESSED120ALUMINAIRE SCHEDULE11ISSUANCECITY SUBMITTAL DEMODATER E T A I L P A R T N E R S LOS ANGELES, CA 90049 11611 SAN VICENTE BOULEVARD, SUITE 900 NORTH MALL RENOVATION PROJECT NUMBER: 17-045 SPRINGFIELD, OR 97477 3000 GATEWAY STREET GATEWAY CENTER 220888SE JOB#:New YorkOmahaHonoluluMiamiLos AngelesSeattle12/06/2023PC SUBMITTAL02/15/2024 1 2ND PC SUBMITTAL04/11/2024LUMINAIRESCHEDULE & ONELINE DIAGRAME2.01TYPICAL CONNECTION FOR MUL T7PLE AUTOMA TIC SENSORS, IF APPLICABLEocrCD-fcBLUE BLUE18/3 PLENUM RATED CABLE•RED- CLASS 2•RED--BLACK-■BLACK-OCCUPANCY SENSOR: WATTSTOPPER #DT-JOO FOR CEILING-MOUNT AND WATTSTOPPER #DT-200 FOR WALL-MOUNTT■OCTRLCEILING-MOUNT PLAN SYMBOL:rNos24VWALL-MOUNT PLAN SYMBOL:.COM llYr:-nWHITE- RED- •REI■RED-■BLACK-fWHITELAMPHOLDERS, BALLASTS, OR DRIVERSLOCAL SWITCH IF APPLICABLEUNSWITCHED HOT>•BLACKWA TTSTOPPER #L VSW-101 LOW VOLTAGE MOMENTARY SWITCH FOR MANUAL ON/OFF OPERA VON©r18/2 PLENUM RATED CABLEI ICOM-RED- REDrZcCLASS 2SW01L-GRAY- GRAY-j-^LED01(NO BUTTON LED TERMINAL CONNECTION)PLAN SYMBOL: $LVTYPICAL CONNECTION FOR MUL TIPLE MANUAL SWITCHES, IF APPLICABLEGENERAL NOTES APPLICABLE TO THIS DETAILPROVIDE ADDITIONAL POWER PACKS TO PROVIDE LOW VOLTAGE POWER TO LOW VOLTAGE SENSORS AND SWITCHES WHEN THE TOTAL CURRENT DRAWN BY THE ASSOCIATED LOW VOLTAGE SENSORS AND SWITCHES EXCEEDS THE RATED LOW VOLTAGE POWER OUTPUT OF THE POWER PACK.PROGRAM OCCUPANCY SENSORS FOR AUTOMATIC "OFF" WITH TIMEOUT SET TO 15 MINUTES. PROGRAM FOR AUTOMATIC “CM" IN CORRIDORS, HALLWAYS, PASSAGEWAYS, ETC. AMO MANUAL "ON“ IN ALL OTHER LOCATIONS.A.B.TYPICAL SINGLE-ZONE CEILING-MOUNT OCCUPANCY SENSOR WIRING DIAGRAM2NOT TO SCALENEUTRAL-* -WHITE-lY-BLACK--BLACK-fWHITEEMERGENCY BATTERIES IF APPLICABLELUMINAIRE SCHEDULELIGHT LAMP SOURCE QTY.SUPPORTEDDIMMINGSELECTEDLAMPDESCRIPTIONMANUFACTURER CATALOG NUMBER VOLTAGE WATTS MOUNTING REMARKSMARKBYCPX—2X2—4000LM—80CRI—35K—SWL—MIN10— ZT—MVOLTN/AN/AA LITHONIA120 36 CEILING, RECESSED LED 0-1OV ENGINEERCPX—2X2—4000LM—80CRI—35K—SWL—MINIO- ZT-MVOLT-E1 OWLCPN/AN/AAE LITHONIA 120 36 CEILING, RECESSED LED 0-1 OV ENGINEERCPX—2X2—4000LM—80CRI—35K—SWL—MINIO- ZT-MVOLT-E1 OWLCPN/AN/AAE2 LITHONIA 120 36 CEILING, SUSPENDED LED 0-1 OV ENGINEERCLX—L48— 4000LM-SEF-FDL-M VOLT- GZ10- 35K-80CRIN/AN/ABLITHONIA120 26 CEILING, SUSPENDED LED 0-1 OV ENGINEERCLX— L48— 4000LM - SEF-FDL-M VOLT- GZ10- 35K-80CRI-E10WLCP-SPDN/AN/ABELITHONIA120 26 CEILING, SUSPENDED LED 0-1 OV ENGINEERBPR02-LIN-FLSH-LED35-S0-4-YBK-BTW-NU-SC-UNV-CA-DM01N/AN/APRUDENTIAL 120 31 CEILING, SUSPENDED LED 0-1 OV OTHERSB4BPR02—LIN-FLSH —LED35—SO-4’—YBK—BTW— NU—SC-UNV—CA—DM01-EMHEN/AN/AB4E PRUDENTIAL 120 31 CEILING, SUSPENDED LED 0-1 OV OTHERSBPR02-LIN-FLSH-LED35-S0-4-YBK-BTW-NU-SC-UNV-CA-DM01N/AN/AC4PRUDENTIAL 277 31 CEILING, SUSPENDED LED 0-1 OV OTHERSBPR02-LIN-FLSH-LED35-S0-4-YBK-BTW-NU-SC-UNV-CA-DM01-EMHEN/AN/AC4E PRUDENTIAL 277 31 CEILING, SUSPENDED LED 0-1 OV OTHERSBPR02-REC-FLSH-LED35-S0-4-YBK-BTW- LP-SC-UNV-X3-DM01 -EMHEN/AN/AC4ES PRUDENTIAL 277 31 CEILING, SURFACE LED 0-1 OV OTHERSBPR02—LIN-FLSH —LED35—SO-5’—YBK—BTW— NU —SC-UNV—CA—DM01N/AN/AC5 PRUDENTIAL 277 39 CEILING, SUSPENDED LED 0-1 OV OTHERSBPR02-REC-FLSH-LED35-S0-5-YBK-BTW-LP-SC-UNV-X3-DM01N/AN/AC5S PRUDENTIAL 27739CEILING, SURFACE LED 0-1 OV OTHERSBPR02-LIN-FLSH-LED35-S0-6-YBK-BTW-NU-SC-UNV-CA-DM01N/AN/AC6 PRUDENTIAL 27747CEILING, SUSPENDED LED 0-1 OV OTHERSBPR02-REC-FLSH-LED35-S0-6-YBK-BTW-LP-SC-UNV-X3-DM01N/AN/AC6S PRUDENTIAL 277 47 CEILING, SURFACE LED 0-1 OV OTHERSBPR02—LIN-FLSH —LED35—SO-8’—YBK—BTW— NU —SC-UNV—CA—DM01N/AN/AC8 PRUDENTIAL 277 62 CEILING, SUSPENDED LED 0-1 OV OTHERSBPR02-REC-FLSH-LED35-S0-8-YBK-BTW-LP-SC-UNV-X3-DM01N/AN/AC8S PRUDENTIAL 277 62 CEILING, SURFACE LED 0-1 OV OTHERSN/A120/277N/AD ERCO84535.02330 CEILING, SURFACE LEDELVOTHERSTWR1 LED ALO SWW2 UVOLT PE DDBTXD - 5,300 LUMENSN/A120/277 N/AE LITHONIA 36 WALL, SURFACE LED NON ENGINEERLDN6RV 30/30 LR6AR LS MVOLT QZ10 N/A120/277 N/AF LITHONIA35CEILING, RECESSED LED 0-1 OV ENGINEERN/A120/277N/ASL1 NLS LIGHTINGVSR-S—T5—16L—7—30K8—UNV—BLK36 GRADE, POLE LED 0-1 OV OTHERSADAPT COMMERCIAL STRING LIGHT STRING: TCSL-S-B-24-120LIGHT ENGINE: ALS-TF-T25-E26-4W-30K-6PK-RGLOBE: LSA-LUC-NSHADE: SHADE-HT-BK-BK-8APROVIDE WITH ALL MOUNTING CABLES AND ACCESSORIES REQUIRED FOR A COMPLETE AND FUNCTIONAL LIGHTING SYSTEM.4W, E26SL2 TIVOLI 120 96 STRING LIGHT LED 24 ELV OTHERSB0L5010A—46—V5—65LED—30—120/277—CA—MN — MN N/A120/277 N/ASL3 ELA65GRADE, SURFACE LED NON OTHERSN/AN/ASL4FX LUMINAIREFB-1LED-BZ 1202 GRADE, SURFACE LEDNONOTHERSAFINISH COLOR SHALL MATCH EXISTING EXTERIOR LIGHTING FIXTURESUTA-31861-20W-W-W30-120/277V N/A120/277 N/ASL5 LIGMAN 20 WALL, SURFACE LED NON OTHERSLIGHT SOURCE CODES SUPPORTED DIMMING CODESLED = LIGHT EMITTING DIODE FL = LINEAR FLUORESCENT CFL = COMPACT FLUORESCENT IND = INCANDESCENT METAL HALIDE HPS = HIGH PRESSURE SODIUM3-WIRE = FLUORESCENT 3-WIRE ECO = LUTRON ECOSYSTEM DMX = DMX512MLV = MAGNETIC LOW VOLTAGE / TRIAC / FORWARD PHASE / LEADING EDGE ELV = ELECTRONIC LOW VOLTAGE / REVERSE PHASE / TRAILING EDGE DIGITAL ADDRESSABLE LIGHTING INTERFACENOT DIMMABLE 0-1OV = 0-1OV IND = INCANDESCENTNONMHDALILUMINAIRE SCHEDULE GENERAL NOTES:LUMINAIRE SYMBOLS THAT ARE SHOWN HALF-SHADED, OR LABELED ’’EM”, ON THE PLAN(S) INDICATE LUMINAIRES THAT SERVE AS EMERGENCY LIGHTING. AT AN EMERGENCY PANELBOARD OR CENTRAL LIGHTING INVERTER, EMERGENCY LIGHTING LUMINAIRES SHALL BE PROVIDED WITH AN EMERGENCY BATTERY. EMERGENCY BATTERY PERFORMANCE REQUIREMENTS.PROPOSED SUBSTITUTIONS FOR LUMINAIRES THAT ARE SELECTED BY OTHERS REQUIRE THE APPROVAL OF THE INDIVIDUAL THAT SELECTED THE LUMINAIRE.UNLESS SERVED BY A CIRCUIT ORIGINATING SEE THE SPECIFICATIONS FOR MINIMUMA.B.CABLE BUS SYSTEMTTAP BOX I TAP BOX I ”R27” ITAP BOX ITAP BOXT 7TAP BOXT TAP BOX I ”R32” ITAP BOX IT“ TAP BOX IM ) ”R24” ITAP BOYTTAP BOX-R29”TAP BOXSUBMETER (NOTE 1) 1SUBMETER | (NOTE 1) 1SUBMETERR28M) ”R30:M) ”R31R26 R25 R33 R23'100/3 100/3 100/3 100/3 100/3 100/3 100/3 100/3100/3 100/3 100/3 400/3 100/3 100/3 100/3 100/3 100/3 100/3 100/3 100/3 100/3 100/3LFUTURESPACEFUTURESPACESPARE SPARE RTAC 11 RTAC 14 RTAC 12 RTAC 13 SPARE RTAC 15 RTAC 16 PANEL SPARE SPARE SPARE SPARE SPARE SPARE SPARE READERBOARDPANELUSPACE400 400 EF422:HVAC HVAC400CABLE BUS SYSTEMnjTAP BOXT TsubMETERTAP BOX I TAP BOX I ”R12” ITAP BOX I ~\TAP BOXT TTAP BOXT T“TTAP BOX I rTAP BOX I r TAP BOX I rTAP BOX ITAP BOXT T“tap bo/tTAP BOXTAP BOXSUBMETER (NOTE 1) 1SUBMETER SUBMETER SUBMETER SUBMETER SUBMETER SUBMETERM) ”R10'M) ”R11M) ”R2(YM) ”R19”R9M) ”R22'R21 R1 3 R14’ R16 R17R1 5' R1 8'MM400/3 100/3 100/3 100/3 100/3 100/3 30/3 100/3 30/3 100/3 100/3 100/3 100/3 100/3 100/3 100/3 30/3 100/3 30/3 100/3 30/3 100/3 30/3 100/3 100/3 100/3 30/3 100/3 30/3 100/3 100/3 100/3 100/3 100/3 100/3J L J L J LL J L J L J L_ J L J L _l L J L J L J L J L JFUTURESPACE726DHVACFUTURESPACE726EHVACFUTURESPACEFUTURESPACEFUTURESPACEFUTURESPACESPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE PANEL SPARE PANEL ”LE—2”SPARE PANEL SPARE SPARESPARE SPARE SPARE SPARE PANELUu400 400 400 400SPACE726DSPACE726ESG1HF1HNHVAC HVAC HVAC HVAC[wTrewaynt Il_ l<^4 " #1/0, #6 GROUND O IN 1 1/2” CONDUIT<^4 - #1/0, #6 GROUND O IN 1 1/2”<^4 - #1/0, "s #6 GROUND IN 1 1/2” F CONDUITCONDUITONE LINE DIAGRAM GENERA. NOTES:A. ALL EXISTING FEEDER SIZES, OVERCURRENT PROTECTION DEVICES, ETC. NOTED ON THE ONE-LINE DIAGRAM AND ALL EXISTING PANEL RATINGS INDICATED ON THE PANEL SCHEDULES ARE THE MINIMUM SIZES REWIRED. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. IF THE EXISTING INSTALLATION DOES NOT MEET THE MINIMA CRITERIA NOTED ON THE ONE-LINE DIAGRAM AM) WITHIN THE PANEL SCHEDULES, MAKE ALL NECESSARY MODIFICATIONS TO BRING THE EXISTING INSTALLATION INTO COMPLIANCE WITH THE MINIMUM SIZES AND/OR RATINGS INDICATED THEREIN AND INCLUDE THE COST OF ANY REQUIRED MODIFICATIONS IN THE INITIAL BID. POST-BID ADDITIONAL COSTS RESULTING FROM AN EXISTING INSTALLATION THAT DOES NOT MEET THE MINIMUM CRITERIA INDICATED WILL NOT BE PERMITTED. IF THE EXISTING INSTALLATION MEETS OR EXCEEDS THE MINIMUM CRITERIA INDICATED, MODIFICATIONS OF THE EXISTING INSTALLATION ARE NOT REQUIRED.rrn rrn rrnSAFETYSWITCH200/3150AFUSESSAFETYSWITCH200/3150AFUSESSAFETYSWITCH200/3150AFUSESl/Jl/Jl/JI I I- #V0.#6 GROUND IN 1 1/2” N CONDUIT,^4 - #1/0, V #6 GROUND O IN 1 1/2” F CONDUIT<^4 - #1/0, #6 GROUND ^ IN 1 1/2” CONDUITr-|-------------1 SUBMETERI (NOTE 1)\CTs[<--I__ [_lCT|---------------1 SUBMETERI I (NOTE 1)\CJ{'—h®i__:_r|---------------1 SUBMETERI I (NOTE 1)\CTs[<---1—®l_.J_lCTONE LINE DIAGRAM KEYED NOTES:PROVIDE SUBMETER TO MATCH EXISTING SUBMETERS LOCATED WITHIN SELECT EXISTING CABLE BUS SYSTEM TAP BOXES.1.CABINET CABINET CABINETU UuSPACE726ASPACE726BSPACE726CONE LINE DIAGRAM1NOT TO SCALELEGENDEXISTING NEW WORKNEW TO EXISTING CONNECTIONNWATTSTOPPER #BZ—250 POWER PACKrdc11921 Freedom Drive, Suite 1110 Reston,VA 20190 703.668.0086rdcollaborative.comc&O PR0#> 16947PE$5/.o.Or Ik)At-OREGON%" 16,softEXPIRES: JUN. 30, 2024Date: 04/16/2024Schnackelengineers.wwwichnackel.com800-581-0963-BLACK- GRAY ■BROWN-CAP •ORANGECAP am(Zbalboa >