HomeMy WebLinkAboutPlans Applicant 4/5/20242645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_COVER.dwg Layout Tab: C-001 COVER User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:22:18 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440COVER FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1101
C-001
OWNER / PROJECT MANAGER:
SANIPAC INC.,
1650 GLENWOOD BLVD
EUGENE, OR 97440
CONTACT: DARREN HANSEN
PHONE:(360) 566-6920
EMAIL:DARREN.HANSEN@WASTECONNECTIONS.COM
CIVIL AND ENVIRONMENTAL ENGINEER:
PBS ENGINEERING AND ENVIRONMENTAL, INC.
1325 SE TECH CENTER DRIVE
SUITE #140
VANCOUVER, WA 98683
(360) 695-3488
SEAN HANRAHAN, PE
SENIOR ENVIRONMENTAL ENGINEER
(360) 213-0433
SEAN.HANRAHAN@PBSUSA.COM
JANESSA SANDOVAL, EIT
ENVIRONMENTAL ENGINEERING STAFF
(541) 686-8684
JANESSA.SANDOVAL@PBSUSA.COM
CORY TAYLOR, EIT
PROJECT ENGINEER
(425) 654-8474
CORY.TAYLOR@PBSUSA.COM
WATER QUALITY TREATMENT SYSTEM PROVIDER:
NEWTERRA PORTLAND
205 SE SPOKANE ST. SUITE #300
PORTLAND, OR 97202
CONTACT:CHRIS FROMME
PHONE:(800) 680-3543
EMAIL:CFROMME@NEWTERRA.COM
SITE INFORMATION:
PHYSICAL ADDRESS:
1650 GLENWOOD BLVD
EUGENE, OR 97440
PROJECT AREA: 8,500 SF
PARCEL AREA: 6.58 AC
SANIPAC, INC.
SANIPAC STORMWATER TREATMENT
SPRINGFIELD, OREGON
LOCATED IN THE CITY OF SPRINGFIELD, OREGON, SW 1
4 OF SEC 34, T17S, R3W,
WILLAMETTE MERIDIAN, OREGON, LAT 44.042972, LONG -123.043883
LANE COUNTY, OREGON, TAX MAP AND LOT #1703343300800
SCALE: 1" = 2000' (@ 22X34)
LOCATION MAP
NTS
VICINITY MAP
Scale 1" =
0 2000'4000'
2000'
1000'
OREGON
PORTLAND
SOURCE: USGS TOPO MAPS
SITE
SITE
CONTACT INFORMATION:
1.THE UNDERGROUND UTILITIES SHOWN HEREON WERE
BASED ON UTILITY LOCATE PAINT MARKS SUPPLIED BY THE
OREGON UTILITY NOTIFICATION CENTER (PRE-SURVEY
TICKET REQUESTS SUBMITTED ON 2/20/2018 AND
PROCESSED AS TICKET NUMBER 18041769.) AS WELL AS
SURFACE EVIDENCE AND PRIVATE AS-BUILT RECORDS.
HOWEVER, LACKING EXCAVATION, THE EXACT LOCATION
OF UNDERGROUND FEATURES CANNOT BE ACCURATELY,
COMPLETELY AND RELIABLY DEPICTED. WHERE
ADDITIONAL OR MORE DETAILED INFORMATION IS
REQUIRED, THE CLIENT IS ADVISED THAT EXCAVATION MAY
BE NECESSARY.
2.CERTAIN UTILITIES ONSITE (WATER, SANITARY, STORM,
GAS, ETC.) MAY NOT HAVE CONDUCTIBLE OR TRACEABLE
LINES AND MAY BE PRESENT.
3.PRIVATE ON-SITE CONDUCTIBLE UTILITY LOCATES WERE
PERFORMED BY ADVANCED UNDERGROUND UTILITY
LOCATING SERVICES ON 3/07/2018
PROJECT NOTES
PROJECT LOCATION
SOURCE: USGS EUGENE EAST, OR QUADRANGLE 1986,
PHOTO REVISED 1986.
BASE SURVEY CONTROL:
VERTICAL DATUM:
THE VERTICAL DATUM FOR THIS SURVEY IS NAVD88.
SITE BENCHMARK: PBS CP#4
ELEVATION=437.17' N: 876173.25' E: 4252445.81'
THE VERTICAL BENCHMARK IS A MAG NAIL IN ASPHALT LOCATED
27' EAST OF THE NORTHEAST CORNER OF A BUILDING, 18'
SOUTHEAST OF A CLEANOUT, AND 37' SOUTHWEST OF A STORM
MANHOLE.
*ELEVATION WAS TRANSFERRED FROM CITY OF SPRINGFIELD
CONTROL POINT 605 (ELEVATION=436.59') THROUGH
DIFFERENTIAL LEVELS.
THE BASIS OF BEARINGS FOR THIS SURVEY IS BASED ON THE
OREGON REAL-TIME GNSS NETWORK (ORGN).
HORIZONTAL DATUM: NAD 83(2011) STATE PLANE COORDINATES
(OREGON SOUTH ZONE 3602)
DISTANCES SHOWN HEREON ARE GROUND DISTANCES.
DRAWING SHEET LIST TABLE
Sheet Number Sheet Title
C-001 COVER
C-002 LEGEND AND GENERAL ABBREVIATIONS
C-003 GENERAL CONSTRUCTION AND ESCP NOTES
C-101 SITE PREPARATION AND ESCP
C-102 ESCP DETAILS
C-103 ESCP DETAILS
C-201 SITE PLAN
C-202 PLAN PROFILE VIEWS
C-203 PUMP, VAULT, STORAGE TANK AND WATER QUALITY DETAILS
C-301 TYPICAL DETAILS
C-302 DETAILS
2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_COVER.dwg Layout Tab: C-002 LEGEND AND GENERAL ABBREVIATIONS User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:22:19 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440LEGEND AND GENERAL ABBREVIATIONS FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1102
C-002
ACAcres
EOPEdge Of Pavement
APP'DApproved
EREnd Curb Return
ASS'YAssembly
ESMTEasement
AVEAvenue
BFButterfly
EXTGExisting
BLVDBoulevard
BMBenchmark
BOBlow Off
BOCBack Of Curb
BRBegin Curb Return
C/OCare Of
CBCatch Basin
CEMCement
CFCubic Feet
CICast Iron
CIRCircle
CMPCorrugated Metal Pipe
COCleanout
COMBCombination
COMPCompaction
CONCConcrete
CPECorrugated Polyethylene
CSPConcrete Sewer Pipe
CTCourt
CYCubic Yard
DDepth
DIDuctile Iron
DIADiameter
DIPDuctile Iron Pipe
DSDown Spout
ELElevation
ELECElectric
Abbreviation Legend
FFFinished Floor
FGFinished Grade
FHFire Hydrant
FLFlange
FMForce Main
FTFoot / Feet
GGas
GLGutter Line
GRDGround
GVGate Valve
Existing Linetype Legend
WET BUFF
Existing Centerline
Existing Right-of-way
Existing Wetland Perimeter
Existing Wetland Buffer
OHP OHP
T T
Existing 15" Storm Sewer Pipe
Existing 24" Water Pipe
Existing 18" Water Pipe
Existing 15" Water Pipe
Existing 12" Water Pipe
Existing 10" Water Pipe
Existing 8" Water Pipe
Existing 6" Water Pipe
Existing 4" Water Pipe
Existing Water Pipe
Existing 18" Storm Sewer Pipe
Existing 24" Storm Sewer Pipe
Existing Telephone Line
Existing Over Head Power Line
Existing Electric Line
Existing Cable Tv Line
Existing Gas Line
Existing Storm Sewer Pipe
Existing 4" Storm Sewer Pipe
Existing 6" Storm Sewer Pipe
Existing 8" Storm Sewer Pipe
Existing 10" Storm Sewer Pipe
Existing 12" Storm Sewer Pipe
Existing 24" Sanitary Sewer Pipe
Existing 18" Sanitary Sewer Pipe
Existing 15" Sanitary Sewer Pipe
Existing 12" Sanitary Sewer Pipe
Existing 10" Sanitary Sewer Pipe
Existing 8" Sanitary Sewer Pipe
Existing 6" Sanitary Sewer Pipe
Existing 4" Sanitary Sewer Pipe
Existing Sanitary Sewer Pipe
Existing Contour 253
Existing Curb
Existing Lot Line
Symbol Legend
Proposed Bollard
Proposed/Relocated Street Light
Proposed Catch Basins
Proposed Rain Drain
Proposed Storm Cleanout
Proposed Storm Manhole
Proposed Sanitary Manhole
Existing Water Valve
GV
WV
Existing Gas Valve
HY DExisting Fire Hydrant
Existing Power Pole
Existing Water Meter
Existing Electrical Pedestal
Existing Project Bench Mark
Existing Monument
SExisting Sanitary Manhole
Existing Storm Manhole
Existing Catch Basin
Existing Combo Inlet
Existing Telephone Pad
Existing Cleanout
Existing Flow Line ➤➤
Existing Paint Stripe
Existing Area Drain
Existing Sanitary Force Main
Existing Building
Proposed Area Drain
Existing Property Line
Existing Irrigation Pipe
Existing 4" Irrigation Pipe
Existing 6" Irrigation Pipe
Existing 8" Irrigation Pipe
Existing 10" Irrigation Pipe
Existing 12" Irrigation Pipe
Existing Irrigation Lateral
Existing 30" Sanitary Sewer Pipe
Existing Railroad
Existing Gravel road
Existing Fence
Existing Wall
Existing Quarter Section
Existing Utility Easement
FO FOExisting Fiber Optic Line
UGP UGPExisting Underground Utility Line
Existing Water Lateral
Proposed Sedimentation Manhole
Proposed Drywell
Proposed Combination Curb Inlet
Proposed Storm Reducer
Proposed Sanitary Cleanout
Proposed Sanitary Reducer
Proposed Sanitary Cap
Proposed Road Barrier
Proposed Road Sign
Proposed Flow Arrow
Proposed Tree Removal
Proposed Fire Protection Vault
Proposed Water Meter
Proposed Water Backflow Device
Proposed Water Bend Tee W/valve
Proposed Water Bend Tee W/tb
Proposed Water 90° Bend W/tb
Proposed Fire Hydrant
Proposed Water 45° Bend W/tb
Proposed Water Stand Pipe
Proposed Water Valve
Proposed Water Bend X
Proposed Water Temporary Blowoff
Proposed Water Standard Blowoff
Proposed Water Reducer
Proposed Water Thrust Block
Proposed Water 11¼° Bend W/tb
Proposed Water 22½° Bend W/tb
CEMCement
Centerline LC
EVCEnd Vertical Curb
CONSTConstruction
Proposed/Future Linetype Legend
Proposed Centerline
Proposed Right-of-way
Proposed Sawcut Line
Proposed Contour
Proposed Easement
Proposed Storm Under Drain
Proposed Storm Rain Drain
Proposed Water Lateral
Proposed Water Pipe
Proposed Storm Pipe
Proposed Sanitary Sewer Pipe
253
Proposed Lot Line
Proposed Curb & Gutter
Proposed End Of Pav't
➤➤➤Proposed Flow Line
Proposed Sidewalk
Proposed Wall
Proposed Sanitary Force Main
Proposed Building
Proposed Setback
Proposed Property Line
Proposed Sanitary Lateral
Proposed Irrigation Pipe
Proposed Irrigation Lateral
Proposed Cut Line
Proposed Score Line
Proposed Paint Stripe
Proposed Fence
Proposed Wetland Buffer
Proposed Wetland Perimeter
Erosion Control Filter Fabric Fence
Symbol Legend
Proposed Irrigation Meter
Proposed Irrigation Backflow Device
Proposed Irrigation Bend Tee W/valve
Proposed Irrigation Bend Tee W/tb
Proposed Irrigation 90° Bend W/tb
Proposed Irrigation 45° Bend W/tb
Proposed Irrigation Stand Pipe
Proposed Irrigation Valve
Proposed Irrigation Bend X
Proposed Irrigation Temporary Blowoff
Proposed Irrigation Standard Blowoff
Proposed Irrigation Reducer
Proposed Irrigation Thrust Block
Proposed Water 11¼° Bend W/tb
Proposed Water 22½° Bend W/tb
IP-1
E 3.30& ID number (Puget Sound)
Erosion Control feature code
Proposed Inlet Protection Pillow
Proposed Gravel Construction Entrance
Proposed Sedimentation Trap
BMP Type (Puget Sound)
Abbreviation Legend
PPPower Pole
PRCPoint Of Reverse Curve
PRVCPoint Of Reverse Vertical Curve
PTPoint Of Tangent
PVCPolyvinyl Chloride
RRadius
R/WRight Of Way
RETReturn
HWHigh Water Elevation
HYDHydrant
IEInvert Elevation
INTXIntersection
INVInvert
LLength
LATLateral
LTLeft
MAXMaximum
MHManhole
MINMinimum
MJMechanical Joint
No. or #Number
OHEOverhead Electric
PAV'TPavement
PCPoint Of Curve
PLPlace
SHTSheet
SSStainless Steel
STLSteel
STStreet
STAStation Centerline
STDStandard
STMStorm
TTangent
TBThrust Block
TBMTemporary Benchmark
TCTop Of Curb
TELTelephone
TEMPTemporary
TOPTop Of Manhole
TYPTypical
UGEUnderground Electric
VCVertical Curve
VERTVertical
WTRWater
W/With
W/OWithout
WMWater Meter
YDYard
RTRight
S/WSidewalk
SANSanitary
PVIPoint Of Vertical Intersection
HORIZHorizontal
APAngle Point
BVCBegin Vertical Curve
Proposed Type 2 Junction Box
Proposed Type 1 Junction Box
Proposed Contactor Service Cabinet
Proposed/Replaced Street Light Fixture
C C C C
F F F F
Proposed Limits of Cut
Proposed Limits of Fill
Proposed Wattle
Aproximate APPRX
ESCErosion Sediment Control
Existing Control Point
PEDPedestal
Proposed Monument
HDPEHigh Density Polyethylene
O.C.On Center
SDStorm Drain
Existing Tree
Existing Flow Arrow
Existing Pipe Removal
Proposed Standard Drain Spigot
2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_COVER.dwg Layout Tab: C-003 GENERAL CONSTRUCTION AND ESCP NOTES User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:22:24 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440GENERAL CONSTRUCTION AND ESCP NOTES FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1103
C-003
A.ALL MATERIALS AND WORKMANSHIP WITHIN THE PUBLIC RIGHT-OF-WAY OR PUBLIC
EASEMENTS SHALL MEET CITY OF SPRINGFIELD DEPARTMENT OF PUBLIC WORKS
"STANDARD CONSTRUCTION SPECIFICATIONS, 1994" AS AMENDED IN 1998 (OR CURRENT
ADDITION), IN ADDITION TO THESE PLANS.
B.OREGON LAW REQUIRES THE CONTRACTOR TO FOLLOW RULES ADOPTED BY THE
OREGON UTILITY NOTIFICATION CENTER. THOSE RULES ARE SET FORTH IN OAR
952-001-0010 THROUGH OAR 952-001-0100. THE CONTRACTOR MAY OBTAIN COPIES OF THE
RULES BY CALLING THE CENTER. NOTE: THE TELEPHONE NUMBER FOR THE OREGON
UTILITY NOTIFICATION CENTER IS (800) 332-2344.
C.LOCATION AND/OR DEPTH OF EXISTING UTILITIES SHOWN ON PLANS ARE APPROXIMATE.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES FOR
UNDERGROUND LOCATION OF FACILITIES AT LEAST 48 HOURS PRIOR TO EXCAVATING OR
"POTHOLING". THE "ONE-CALL" NUMBER IS (800) 332-2344
D.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH UTILITY COMPANIES ON
THE TIMING OF INSTALLATION OF THEIR FACILITIES.
E.THE CONTRACTOR SHALL PROVIDE ALL TRAFFIC CONTROL DEVICES NECESSARY TO
PROTECT AND SAFEGUARD THE PUBLIC AND WORKERS AGAINST INJURY AND PROTECT
THE WORK AGAINST DAMAGE. ALL TEMPORARY TRAFFIC CONTROL SIGNING AND DEVICES
SHALL BE IN PLACE PRIOR TO BEGINNING WORK. ALL TRAFFIC CONTROL SHALL CONFORM
TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS
(MUTCD), CURRENT EDITION, AS SUPPLEMENTED AND AMENDED BY THE OREGON
SUPPLEMENTS. FLAGGING SHALL BE PERFORMED AS SHOWN IN THE OREGON STATE
HIGHWAY DIVISION HANDBOOK, “SIGNING AND FLAGGING STANDARDS FOR SHORT-TERM
WORK ZONES", CURRENT EDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
REQUIRED TRAFFIC CONTROL AS FIELD CONDITIONS WARRANT. THE CONTRACTOR SHALL
SUBMIT A TRAFFIC CONTROL PLAN AT THE PRE-CONSTRUCTION CONFERENCE FOR CITY
REVIEW AND APPROVAL (IF APPLICABLE).
F.ALL SANITARY AND STORM SEWER CONNECTIONS TO EXISTING CITY OWNED FACILITIES
(PIPE, CATCH BASINS, MANHOLES, ETC.) SHALL BE INSPECTED BY THE CONTRACTOR AND
THE CITY'S PUBLIC WORKS MAINTENANCE DEPARTMENT PRIOR TO HOOKING UP TO THEM.
CONTACT KEITH MIYATA (726-3615) OR RON SATHER (726-2240) NO LESS THAN 48 HOURS
PRIOR TO DESIRED INSPECTION TIME.
G.BEFORE BACK-FILLING THE END OF A MAINLINE PIPE, NOT ENDING AT A MANHOLE OR A
CLEAN OUT, THE CONTRACTOR SHALL PERFORM THE TV INSPECTION AS REQUIRED BY
THE STANDARD SPECIFICATIONS AND ALLOW THE CONSULTING ENGINEER TO
DETERMINE THE EXACT LOCATION AND ELEVATION OF THE END OF THE PIPE.
H.WHERE CONNECTING TO AN EXISTING PIPE. THE CONTRACTOR SHALL EXPOSE THE END
OF THE EXISTING PIPE AND ALLOW THE ENGINEER TO VERIFY EXACT LOCATION AND
ELEVATION, CONDITION, AND POSITIVE FLOW BEFORE LAYING ANY NEW PIPE ON THAT
SYSTEM.
I.THE SEWER GRADE SHALL BE PER THE PLANS SPECIFICATIONS AND WITH THE MINIMUM
COVER AS SHOWN ON THE PLANS.
J.THE CONTRACTOR SHALL INTERNALLY TELEVISION INSPECT THE SEWER AFTER ALL
BACKFILL AND BEFORE THE FINAL LIFT OF ASPHALT PAVING. THE CONTRACTOR SHALL
SUPPLY THE CITY WITH A WRITTEN T.V. REPORT AND VIDEO TAPE FOR CITY APPROVAL AT
LEAST 2 WORKING DAYS BEFORE THE PRE-PAVING MEETING.
K.CONTRACTOR TO SCHEDULE A PRE-PAVING CONFERENCE 24 HOURS PRIOR TO PAVING.
CONTACT RON SATHER (726-2240).
L.ALL JOINTS BETWEEN EXISTING AND NEW ASPHALT PAVING SHALL BE SEALED WITH
POLYMERIZED ASPHALT AND SANDED TO PREVENT PICK UP.
M.COMPACTION REQUIREMENTS:
LAYER RATE TEST
SUBGRADE 95%T99
CRUSHED ROCK 95%T180
ASPHALT (LOCAL)90%RICE
ASPHALT (COLLECTOR/ARTERIAL)92%RICE
N.CONCRETE COMPRESSIVE STRENGTH REQUIREMENTS (PSI):
CONCRETE USE FIELD LABORATORY
SIDEWALK/ADA RAMPS 3000 3450
CURBS/GUTTERS 3500 4025
DRIVEWAYS 3500 4025
PAVEMENT 4000 4600
O.CONTRACTOR IS RESPONSIBLE TO OBTAIN APPLICABLE PERMITS FROM OTHER AGENCIES
WITH JURISDICTIONS SUCH AS LANE COUNTY, OREGON DEPARTMENT OF
TRANSPORTATION, OREGON DIVISION OF STATE LANDS, THE ARMY CORPS OF
ENGINEERS, OR THE DEPARTMENT OF ENVIRONMENTAL QUALITY.
P.ALL IMPROVEMENTS THAT WILL BE PRIVATELY OWNED AND MAINTAINED WILL BE BOUND
BY THE CURRENT REQUIREMENTS OF THE STATE OF OREGON STRUCTURAL SPECIALTY
CODE, PLUMBING SPECIALTY CODE, AND/OR CITY OF SPRINGFIELD BUILDING DIVISION
REQUIREMENTS. CONTRACTOR IS RESPONSIBLE TO OBTAIN APPLICABLE PERMITS FROM
OTHER CITY DEPARTMENT PRIOR TO DOING PRIVATE WORK.
Q.EARTHWORK OUTSIDE THE RIGHT OF WAY AND PUBLIC EASEMENTS IN EXCESS OF 50
CUBIC YARDS REQUIRES A LAND AND DRAINAGE ALTERATION PERMIT (LDAP)
R.A PRE-CONSTRUCTION CONFERENCE IS REQUIRED BEFORE START OF CONSTRUCTION.
ALL UTILITIES, CONTRACTORS AND CITY REPRESENTATIVES SHALL HAVE RECEIVED THE
FINAL APPROVED PLANS AT LEAST 5 WORKING DAYS PRIOR TO THE PRE CONSTRUCTION
CONFERENCE.
S.THE ENGINEER AND/OR CITY HAVE THE RIGHT TO REQUIRE ADDITIONAL WORK NOT
SHOWN HEREIN BUT NECESSARY FOR THE SUCCESSFUL COMPLETION OF THE PROJECT.
T.REQUESTS BY THE CONTRACTOR FOR CHANGES SHALL BE APPROVED BY THE ENGINEER
AND THE CITY PRIOR TO IMPLEMENTATION.
U.CONTRACTOR SHALL SUBMIT EVIDENCE OF INSURANCE IN ACCORDANCE WITH THE
STANDARD SPECIFICATION TO THE CITY FOR APPROVAL PRIOR TO BEGINNING WORK.
V.CONTRACTOR SHALL BE AWARE IF PAVING IS NOT SCHEDULED OR DOES NOT OCCUR
PRIOR TO OCTOBER 15, WET WEATHER PROVISIONS INCLUDED ADDITIONAL ROCK
SUBSTRUCTURE AND GEOTEXTILE FABRIC SHALL BE USED. REFER TO STANDARD
SPECIFICATION SECTION 301.1.01 AND THE TYPICAL CROSS SECTIONS CONTAINED
HEREIN FOR DETAILS.
CONSTRUCTION SEQUENCE
CITY OF SPRINGFIELD, CHAPTER 8.07.
A DETAILED CONSTRUCTION SEQUENCE IS NEEDED TO ENSURE THAT EROSION AND SEDIMENT
CONTROL MEASURES ARE APPLIED AT THE APPROPRIATE TIMES. PRIOR TO SCHEDULING THE
PRE-CONSTRUCTION CONFERENCE, THE ENGINEER SHALL IDENTIFY THE APPROXIMATE DATES OF
PROPOSED ACTIVITIES AND SUBMIT IT TO THE CITY FOR REVIEW AND APPROVAL.
A RECOMMENDED CONSTRUCTION SEQUENCE IS PROVIDED BELOW:
A.CONDUCT A PRE-CONSTRUCTION MEETING.
B.FLAG OR FENCE CLEARING LIMITS
C.INSTALL CATCH BASIN PROTECTION, IF REQUIRED.
D.GRADE AND INSTALL CONSTRUCTION ENTRANCE(S).
E.INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
F.CONSTRUCT SEDIMENT PONDS AND TRAPS.
G.GRADE AND STABILIZE CONSTRUCTION ROADS.
H.CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.)
SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT.
I.MAINTAIN EROSION PREVENTION AND SEDIMENT CONTROL MEASURES IN ACCORDANCE WITH
CITY OF SPRINGFIELD STANDARDS AND MANUFACTURER'S RECOMMENDATIONS.
J.UPDATE EROSION AND SEDIMENT CONTROL MEASURES TO HANDLE MAJOR CHANGE IN SITE
CONDITIONS.
K.COVER ALL AREAS THAT WILL REMAIN UNDISTURBED FOR MORE THAN SEVEN DAYS DURING THE
DRY SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH,
COMPOST, PLASTIC SHEETING, OR EQUIVALENT.
L.STABILIZE ALL AREAS WITHIN SEVEN DAYS OF REACHING FINAL GRADE.
M.SEED OR SOD ANY AREAS TO REMAIN UNDISTURBED FOR MORE THAN 30 DAYS.
N.UPON COMPLETION OF THE PROJECT, STABILIZE ALL DISTURBED AREAS AND REMOVE BMP(S) IF
APPROPRIATE.
THE CONTRACTOR SHALL CONDUCT THE ORDER OF WORK TO ALLOW ALL EXISTING FACILITIES TO
REMAIN OPERATIONAL EXCEPT AS NOTED HEREIN DURING THE CONSTRUCTION OF THIS PROJECT,
AND TO MINIMIZE DISRUPTION OF ANY UTILITY SERVICE. THE ORDER OF WORK FOR THE CONTRACT
SHALL BE SO PLANNED AS TO COMPLETE ALL WORK WITHIN THE TIME LIMITS ESTABLISHED WITHIN
THE CONTRACT PROVISIONS.
GENERAL CONSTRUCTION NOTES
FOLLOWING ARE THE STANDARD ESCP CONSTRUCTION NOTES:
A. APPROVAL OF THIS EROSION, SEDIMENT AND POLLUTION CONTROL PLAN (ESCP) DOES NOT CONSTITUTE AN APPROVAL OF PERMANENT ROAD OR STORMWATER SYSTEM DESIGN (E.G., SIZE AND LOCATION OF ROADS, PIPES, RESTRICTORS,
CHANNELS, RETENTION FACILITIES, BEST MANAGEMENT PRACTICES [BMPS], OR UTILITIES)
B. THE IMPLEMENTATION OF THIS ESCP AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESCP BMPS IS THE RESPONSIBILITY OF THE CONTRACTOR UNTIL ALL CONSTRUCTION IS COMPLETED AND APPROVED
AND THE PROJECT IS ACCEPTED BY THE CITY.
C. IN THE EVENT THE ESC FACILITIES IDENTIFIED ON THE ESCP ARE NOT FUNCTIONING PROPERLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR IMMEDIATELY IMPLEMENTING CHANGES TO THE ESCP AS DIRECTED BY THE ENGINEER OR HIS/HER
INSPECTOR. THE ENGINEER, THE INSPECTOR OR THE CITY MAY STOP ALL CONSTRUCTION ACTIVITY ON SITE UNTIL THE EROSION PROBLEM IS CORRECTED AND ALL ESC FACILITIES ARE FUNCTIONING PROPERLY. IF THE CONTRACTOR DOES NOT
IMMEDIATELY IMPLEMENT CHANGES TO THE ESCP IDENTIFIED BY THE ENGINEER OR HIS/HER INSPECTOR, THE CITY MAY IMPLEMENT THE NECESSARY CHANGES AND REQUIRE PAYMENT FROM THE CONTRACTOR PRIOR TO PROJECT ACCEPTANCE
BY THE CITY,
D. THE BOUNDARIES OF THE CLEARING LIMITS SHOWN ON THIS ESCP SHALL BE CLEARLY FLAGGED BY A CONTINUOUS LENGTH OF SURVEY TAPE (OR FENCING, IF REQUIRED) PRIOR TO CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO
DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CONTRACTOR SHALL MAINTAIN THE CLEARING LIMITS FOR THE DURATION OF THE CONSTRUCTION.
E. THE ESC FACILITIES SHOWN ON THE ESCP SHALL BE CONSTRUCTED PRIOR TO OR IN CONJUNCTION WITH ALL CLEARING AND GRADING SO AS TO ENSURE THAT THE TRANSPORT OF SEDIMENT TO SURFACE WATERS, STORMWATER SYSTEMS, AND
ADJACENT PROPERTIES IS MINIMIZED.
F. THE ESC FACILITIES SHOWN ON THIS ESCP ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS
AND MODIFIED TO ACCOUNT FOR CHANGING SITE CONDITIONS, (ADDITIONAL SUMP PUMPS, RELOCATION OF DITCHES AND SILT FENCES, ETC.). ALL CHANGES TO THE ESCP SHALL BE NOTED ON THE CONTRACTORS AND INSPECTOR’S APPROVED
ESCP PLAN SET. ONE UPDATED ESCP PLAN SET SHALL BE KEPT ON SITE AT ALL TIMES.
G. THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE CONTRACTOR AND MAINTAINED TO ENSURE CONTINUED PROPER FUNCTIONING. WRITTEN RECORDS SHALL BE KEPT OF WEEKLY REVIEWS OF THE ESC FACILITIES DURING THE WET SEASON
(OCTOBER 1 TO APRIL 30) AND OF MONTHLY REVIEWS DURING THE DRY SEASON (MAY 1 TO SEPTEMBER 30).
H. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1 TO APRIL 30) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1 TO SEPTEMBER 30)
SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.).
I. THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN TWENTY-FOUR HOURS FOLLOWING A STORM EVENT.
J.AT NO TIME SHALL MORE THAN ONE FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH
SEDIMENT-LADEN WATER INTO THE DOWNSTREAM SYSTEM.
K. STABILIZED CONSTRUCTION ENTRANCES AND ROADS SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS WASH PADS, MAY BE REQUIRED TO
ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN FOR THE DURATION OF THE PROJECT.
L. ANY PERMANENT FLOW CONTROL FACILITIES USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY.
M. WHERE STRAW MULCH FOR TEMPORARY EROSION CONTROL IS REQUIRED, IT SHALL BE APPLIED AT A MINIMUM THICKNESS OF TWO TO THREE INCHES.
N. IN PREPARATION FOR THE WET SEASON, ALL DISTURBED AREAS SHALL BE REVIEWED TO IDENTIFY WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE WINTER RAINS. A SKETCH MAP OF THOSE AREAS TO BE SEEDED AND
THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY BY SEPTEMBER 15TH. THE CITY CAN REQUIRE SEEDING OF ADDITIONAL AREAS IN ORDER TO PROTECT SURFACE WATERS, ADJACENT PROPERTIES, OR
STORMWATER FACILITIES. DISTURBED AREAS IDENTIFIED FOR SEEDING SHALL BE SEEDED PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1).
SECTION 8.06: EROSION CONTROL CONSTRUCTION NOTES
CITY OF SPRINGFIELD, CHAPTER 8
T T T
T
EX. TRUCK
WASH BUILDING
BUILDING
EX OUT FALL #3
IE=431.52' 18" PVC OUT (NW)
EX STORM CLEANOUT #4
RIM=437.88'
EX SDMH TYPE 2 #5
RIM=437.76'
IE=431.69' 18" PVC S (IN)
IE=431.65' 18" PVC NW (OUT)
EX CB #1
RIM=437.43'
IE=436.30' 6" STEEL NE (OUT)
EX CB #2
RIM=436.53'
IE=435.51' 6" STEEL W (OUT)
EX CB #6
RIM=436.20'
IE=434.63' 6" STEEL S (OUT)
EX CB #7
RIM=436.44'
IE=435.51' 6" STEEL E (OUT)
SUMP=432.76'EX SDMH TYPE 2 #8
RIM=436.28'
IE=432.98' 6" PVC N (IN)
IE=432.86' 8" PVC E (OUT)
SUMP=432.68'
EX SDMH TYPE 2 #9
RIM=437.04'
IE=432.04' 10" PVC E (IN)
IE=432.04' 10" PVC S (IN)
IE=432.06' 8" PVC W (IN)
IE=431.99' 18" PVC N (OUT)
EX CB #12
RIM=435.99'
IE=434.98' 6" STEEL E (OUT)
SUMP=432.29'
EX CB #11
RIM=435.71'
IE=433.95' 8" STEEL N (OUT)
SUMP=431.99'
EX CB #13
RIM=436.23'
IE=434.59' 6" STEEL E (OUT)
SUMP=432.53'
EX SDMH TYPE 2 #15
RIM=436.92'
IE=433.48' 6" PVC SE (IN)
IE=433.42' 6" PVC S (IN)
IE=433.92' 10" PVC N (OUT)
EX SDMH TYPE 2 #10
RIM=436.85'
IE=433.10' 6" PVC N (IN)
IE=433.03' 6" PVC E (IN)
IE=433.08' 6" PVC S (IN)
IE=432.71' 10" PVC W (OUT)
EX SS CO #1
RIM=437.73'
EX SS CO #2
RIM=437.85'
EX SS CO #3
RIM=437.86'
EX SS CO #4
RIM=437.89'
EX SS CO #5
RIM=437.86'
EX SSMH #6
RIM=437.36'
IE=430.36' 8" CONC NE (IN)
IE=429.37' 24" CONC E (IN)
IE=430.37' 8" CONC S (IN)
IE=429.32' 24" CONC W (OUT)
EX SSMH #7
RIM=438.40'
IE=429.88' 24" CONC S (IN)
IE=429.84' 24" CONC W (OUT)
EX SS CO #8
RIM=437.19'
EX SS CO #9
RIM=437.14'
CONCRETE WALL
CONCRETE WALL
CONCRETE WALL
CONCRETE WALL
SITE BENCHMARK
PBS CP#4
MAG NAIL
ELEV.=437.17'1+002+003+004+005+001EAST 17TH AVENUE GLENWOODBOULEVARDEXISTING PARKING STRIPE (TYP)
55'
56'
24'58'175'107'
CENTERLINE LINE DATA
#
1
Length
400.000
Direction
N00° 00' 00.00"E
Scale 1" =
0 40'80'
40'
20'2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
RIGHT-OF-WAY DISCLAIMER
THE RIGHT-OF-WAY AND/OR PROPERTY LINES
SHOWN HEREON ARE BASED ON AVAILABLE
INFORMATION, NOT ON A SURVEYED LOCATION AND
ARE ONLY APPROXIMATE.REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_SP.dwg Layout Tab: C-101 SITE PREPARATION AND ESCP User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:22:39 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440SITE PREPARATION AND ESCP FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1104
C-101
EROSION CONTROL CONSTRUCTION NOTES:
STOCKPILE AREA. COVER STOCKPILE AREAS PER DETAIL 1, SHEET C-102 AND EROSION
CONTROL NOTES, SHEET C-003 AND THIS SHEET.
INLET PROTECTION, TYPE 3, PER DETAIL 2, SHEET C-102.
INLET PROTECTION, TYPE 4, PER DETAIL 3, SHEET C-102.
TEMPORARY FENCE, PER DETAIL 4, SHEET C-102.
STRAW WATTLES PER DETAIL 1, SHEET C-103.
SEDIMENT BARRIER TYPE 8, PER DETAIL 2, SHEET C-103.
SEDIMENT FENCE, PER DETAIL 3, SHEET C-103. NOTE, SILT FENCE IS OFFSET FROM THE
CLEAR AND GRUB LIMIT 1-FT TO THE EXTERIOR OF THE CLEARING LIMITS FOR CLARITY
PROTECT EXISTING CB / SDMH / STORM SYSTEM / SANITARY SEWER LINES / SANITARY
SEWER MANHOLE / SANITARY SEWER SYSTEM / WALL / BUILDING / FENCE / VAULT / STAIRS /
STEPS / MONUMENT / CONTROL POINT / ILLUMINATION SYSTEM / LIGHT / CURB.
CLEAR AND GRUB LIMIT.
REMOVE AND WASTEHAUL EXISTING STORM DRAINAGE PIPE, OR STORM DRAINAGE
STRUCTURE.
CONTRACTOR SHALL SAWCUT, REMOVE AND WASTE HAUL EXISTING CURB, ASPHALT AND
SUBGRADE FOR REQUIRED IMPROVEMENTS. SEE SHEET C-201 FOR EXTENTS OF
IMPROVEMENTS, COORDINATE WITH OWNER PRIOR TO COMMENCING WORK.
1
2
3
4
5
6
7
8
9
10
11
GENERAL EROSION, SEDIMENT AND
PROPOSED CENTERLINE SANIPAC WQ ALIGNMENT DATA
1.REFER TO THIS SHEET FOR EROSION CONTROL PLANS, AND SHEET
C-102 FOR DETAILS.
2.CONSTRUCTION ACCESS ON SANIPAC PRIVATE PROPERTY FROM THE
TRUCK ENTRANCE TO EAST 17TH AVENUE, COORDINATE WITH SITE
MANAGER AND OWNER.
3.SIGNIFICANT VARIATION AND DEGREE OF EROSION CONTROL EFFORT
WILL BE DICTATED BY WEATHER CONDITIONS. THE CONTRACTOR
SHALL BE PREPARED TO PROVIDE EXTRA EROSION CONTROL
PROVISIONS AND EFFORT DURING WINTER AND WET WEATHER
CONDITIONS BEYOND THAT NORMALLY REQUIRED DURING SUMMER
AND DRY WEATHER CONDITIONS. FINE GRAINED AND
UNCONSOLIDATED SOILS ON SLOPING SITES MAY BECOME UNSTABLE
WHEN SUBJECT TO EXCESSIVE MOISTURE.
4.REGRADING OF EXISTING SWALE: DURING CONSTRUCTION
CONTRACTOR SHALL PROTECT INTEGRITY OF STORMWATER SYSTEM
FROM SILTATION AND PLUGGING, INCLUDING REMOVAL OF ANY
SILTATION FROM UPSTREAM OR DOWNSTREAM STORM SYSTEM
(CB'S, PIPES, ETC.).
5.STOCKPILE LOCATION SHOWN FOR DISPLAY ONLY, ACTUAL LOCATION
DETERMINED BY CONTRACTOR WITH OWNER APPROVAL. STOCKPILE
SHALL BE COVERED WITH PLASTIC SHEETING WHEN EXPOSED FOR 2
OR MORE DAYS AND/OR OVER A LONG HOLIDAY WEEKEND DURING
WET WEATHER MONTHS.
6.REFER TO CITY OF SPRINGFIELD / ODOT EROSION AND SEDIMENT
CONTROL NOTES MANUAL FOR REMAINING STANDARD EROSION
CONTROL NOTES (TYP).
POLLUTION CONTROL PLAN (ESPCP) NOTES
2
A.THE ESCP BMPS SHOWN ON THIS PLANSET ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE
CONSTRUCTION PERIOD, THESE ESCP BMPS SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS OR SITE CONDITIONS AND
TO ENSURE THAT SEDIMENT AND SEDIMENT-LADEN WATER DO NOT LEAVE THE SITE. ADDITION AND REMOVAL OF BMPS SHOULD BE
DOCUMENTED IN THE DAILY INSPECTION LOG AND, IN CASES OF ESCP REVISION, ON THE REVISED ESCP.
B.THE ESCP BMPS ON ACTIVE SITES SHALL BE INSPECTED DAILY BY THE ONSITE EROSION AND SEDIMENT CONTROL MANAGER, AND THE
EROSION, SEDIMENT, AND POLLUTANT CONTROL BMPS SHALL BE MAINTAINED, ADJUSTED, REPAIRED, AND REPLACED AS NECESSARY, TO
ENSURE THAT THE BMPS ARE FUNCTIONING PROPERLY.
C.THE ESCP BMPS ON INACTIVE SITES SHALL BE INSPECTED AT LEAST ONCE A MONTH AND WITHIN 24 HOURS FOLLOWING A STORM EVENT,
AND EROSION, SEDIMENT, AND POLLUTANT CONTROL BMPS SHALL BE MAINTAINED, ADJUSTED, REPAIRED, AND REPLACED AS NECESSARY,
TO ENSURE THAT THE BMPS ARE FUNCTIONING PROPERLY.
D.TEMPORARY STABILIZATION BMPS SHALL BE MAINTAINED UNTIL PERMANENT STABILIZATION BMPS ARE ESTABLISHED.
E.ALL INSPECTIONS CONDUCTED BY THE ONSITE EROSION AND SEDIMENT CONTROL MANAGER SHALL BE NOTED IN AN INSPECTION LOG
INDICATING THE DATE AND TIME OF THE INSPECTION. THE INSPECTION LOG SHALL BE MADE AVAILABLE TO THE DIRECTOR OR DIRECTOR'S
DELEGATE UPON REQUEST.
F.AFTER ESCP BMP INSTALLATION BUT PRIOR TO PERFORMING OTHER GROUND-DISTURBING ACTIVITIES, A PRE-CONSTRUCTION EROSION
CONTROL INSPECTION SHALL BE APPROVED.
G.AFTER INSTALLATION OF PERMANENT STABILIZATION BMPS, A PERMANENT EROSION CONTROL BMPS INSPECTION SHALL BE APPROVED.
COMPLIANCE WITH STATE AND FEDERAL PERMITS STANDARD NOTE
A.COMPLIANCE WITH SPRINGFIELD CITY CODE AND APPROVAL OF AN ESPCP DOES NOT RELIEVE THE OPERATOR FROM REQUIREMENTS SET
FORTH BY OTHER STATE, FEDERAL, AND LOCAL STANDARDS OR REQUIREMENTS. IT IS THE DUTY OF THE RESPONSIBLE PARTY TO OBTAIN
PERMIT COVERAGE AND ENSURE COMPLIANCE WITH ALL REGULATORY AGENCIES, PERMIT CONDITIONS, AND PERFORMANCE STANDARDS.
ADDITIONAL ESCP REQUIREMENTS:
24-HOUR ONSITE EROSION AND SEDIMENT CONTROL MANAGER CONTACT
NAME: PHONE NO:
ADDITIONAL INSPECTION AND MAINTENANCE NOTES
8
2
2
2
2
2
3
3
8(TYP)
8(TYP)
8 (TYP)
1 STOCKPILE AREA
(COORDINATE WITH
OWNER AS REQUIRED)
10
9(TYP)
7(TYP)
10 (TYP)
10
4(TYP)
5
8(TYP)
8(TYP)
8(TYP)
6(TYP)
11(TYP)
11(TYP)
10
8(TYP)
8(TYP)
8(TYP)
8 (TYP)
2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_TESC-DT.dwg Layout Tab: C-102 ESCP DETAILS User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:22:52 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440ESCP DETAILS FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1105
C-102
MINIMUM 2 SADDLE
CLAMP FOR EACH
FENCE PANEL
CONNECTION
BLOCK OR EQUIVALENT
TO PROVIDE STABLE
FENCE
CHAIN LINK FENCE
PANEL OR
EQUIVALENT
4
C-102
TEMPORARY FENCE
SCALE: NONE
1
C-102
PLASTIC SHEETING
SCALE: NONE
2
C-102
INLET PROTECTION TYPE 3
SCALE: NONE
3
C-102
INLET PROTECTION TYPE 4
SCALE: NONE
2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_TESC-DT.dwg Layout Tab: C-103 ESCP DETAILS User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:22:54 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440ESCP DETAILS FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1106
C-103
1
C-103
STRAW WATTLES
SCALE: NONE
2
C-103
SEDIMENT BARRIER TYPE 8
SCALE: NONE
3
C-103
SEDIMENT FENCE
SCALE: NONE
AQUIP
300S
STORAGE
TANK
EX. TRUCK
WASH BUILDING
2+003+004+005+00434438
43743
7
437
437
4374374
3
8
13'
SITE
BENCHMARK
PBS CP#4
MAG NAIL
ELEV.=437.17'
EX CB #1
RIM=437.43'
IE=436.30' 6" STEEL NE (OUT)
EX CB #2
RIM=436.53'
IE=435.51' 6" STEEL W (OUT)
EX CB #6
RIM=436.20'
IE=434.63' 6" STEEL S (OUT)
EX CB #7
RIM=436.44'
IE=435.51' 6" STEEL E (OUT)
SUMP=432.76'
EX SDMH TYPE 2 #8
RIM=436.28'
IE=432.98' 6" PVC N (IN)
IE=432.86' 8" PVC E (OUT)
SUMP=432.68'
EX SDMH TYPE 2 #9
RIM=437.04'
IE=432.04' 10" PVC E (IN)
IE=432.04' 10" PVC S (IN)
IE=432.06' 8" PVC W (IN)
IE=431.99' 18" PVC N (OUT)
EX CB #12
RIM=435.99'
IE=434.98' 6" STEEL E (OUT)
SUMP=432.29'
EX CB #11
RIM=435.71'
IE=433.95' 8" STEEL N (OUT)
SUMP=431.99'
EX SDMH TYPE 2 #10
RIM=436.85'
IE=433.10' 6" PVC N (IN)
IE=433.03' 6" PVC E (IN)
IE=433.08' 6" PVC S (IN)
IE=432.71' 10" PVC W (OUT)
EX SS CO #1
RIM=437.73'
EX SS CO #2
RIM=437.85'
EX SS CO #3
RIM=437.86'
EX SS CO #4
RIM=437.89'
EX SS CO #5
RIM=437.86'
EX SSMH #6
RIM=437.36'
IE=430.36' 8" CONC NE (IN)
IE=429.37' 24" CONC E (IN)
IE=430.37' 8" CONC S (IN)
IE=429.32' 24" CONC W (OUT)
EX SS CO #8
RIM=437.19'
EX SS CO #9
RIM=437.14'
CONCRETE
WALL
CONCRETE WALL
CONCRETE WALL
4+17.28 (117.12' LT)
(TYP)5
3+59.31 (65.33' LT)
SDMH TYPE 2 DUPLEX PUMP STATION
RIM 437.76 W/SOLID LID
18" EX PVC IE 431.69 IN (S)
8" HDPE IE 433.50 IN (N)
6" HDPE (FM) IE 433.50 OUT (W)
18" HDPE (OVERFLOW) IE 434.75 OUT (NW)15' (TYP)15' (TYP)
26 LF 18" SD HDPE
@ S=0.1062
4+14.47 (127.65' LT)
SAMPLING MH
RIM 438.40
6" HDPE IE 435.50 IN (S)
18" HDPE (OVERFLOW) IE 434.30 IN (SE)
18" HDPE IE 434.30 OUT (W)
5 LF 6" SD HDPE (FM)
10 LF 6" SD HDPE
111 LF 6" SD HDPE (FM)
5 LF 6" SD HDPE (FM)
6" SD HDPE (FM)
BUTTERFLY
VALVE (TYP)
90° HORZ
BEND
90° VERT
BEND
3+88.06 (121.15' LT)12
3+72.49 (183.67' LT)13
3+75.06 (117.65' LT)1421'4+48.66 (65.59' LT)
CB-02 TYPE 1 W/SOLID LID
RIM 438.06
8" DI IE 434.80 IN (NE)
8" HDPE IE 434.80 OUT (S)
4+78.64 (48.42' LT)
CB-01 TYPE 1 W/SOLID LID
RIM 437.82
8" DI IE 435.05 OUT (SW)
90° HORZ
BEND
5'
35 LF 8" SD DI
@ S=0.0072
89 LF 8" SD HDPE
@ S=0.0145
83 LF 18" SD HDPE (OVERFLOW)
@ S=0.0054
3+98.66 (137.03' LT)4 15
Scale 1" =
0 20'40'
20'
10'2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
RIGHT-OF-WAY DISCLAIMER
THE RIGHT-OF-WAY AND/OR PROPERTY LINES
SHOWN HEREON ARE BASED ON AVAILABLE
INFORMATION, NOT ON A SURVEYED LOCATION AND
ARE ONLY APPROXIMATE.REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
CONSTRUCTION NOTES:
HDPE FORCE MAIN, WITH THRUST BLOCKS, INSTALL THRUST BLOCKS PER INSTALLATION
DETAIL, SHEET C-301, AND PIPE PER DETAIL 2, SHEET C-302.
PROPOSED DUPLEX PUMP SYSTEM IN PROPOSED STORM DRAIN MANHOLE, PER PUMP
STATION DETAIL, SHEET C-203.
AQUIP WATER QUALITY SYSTEM OVERFLOW BYPASS AND OUTLET DISCHARGE PIPE, PER
AQUIP DETAILS, SHEET C-203.
MATCH EXISTING GRADE.
(10) ECOLOGY BLOCKS, PER DETAIL 4, SHEET C-302. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF BLOCKS WITH ALL BURIED UTILITIES, INCLUDING NEW ELECTRICAL CONDUIT.
CONTACT AND COORDINATE WITH OWNER AS REQUIRED.
CONTRACTOR SHALL PROVIDE PAVEMENT RESTORATION, PER DETAIL 2, SHEET C-301.
CONTRACTOR SHALL INSTALL ELECTRICAL CONDUIT PER JURISDICTIONAL STANDARDS
REQUIREMENTS FOR ELECTRICAL TRENCHING. COORDINATE WITH OWNER PRIOR TO
COMMENCING WORK.
CONTRACTOR SHALL POTHOLE EXISTING UTILITIES (STORM, SEWER, OUTFALL PIPE, ETC) AND
NOTIFY ENGINEER IMMEDIATELY IF DISCREPANCIES WITH THE PLANS IF FOUND.
CONNECT EXISTING STORM DRAINAGE PIPE TO NEW STORM STRUCTURE, PER CITY OF
SPRINGFIELD TYPICAL PIPE CONNECTIONS DETAIL 4-7, SHEET C-301.
CONNECT PROPOSED STORM PIPE / FORCE MAIN TO PROPOSED AQUIP SYSTEM PER CITY OF
SPRINGFIELD TYPICAL PIPE CONNECTIONS DETAIL 4-7, SHEET C-301.
CONTRACTOR SHALL PROVIDE VEGETATED SURFACE RESTORATION, PER DETAIL 3, SHEET
C-302.
PROPOSED AQUIP 300S LOCATION, PER TYPICAL STORMWATERx LAYOUT, SHEET C-203.
COORDINATE WITH STORMWATERx, NEWTERRA SERVICES AND OWNER AS REQUIRED.
STORMWATER STORAGE TANK, PER PROFILE, SHEET C-202, AND MODERN MFG., INC., DETAIL,
SHEET C-203. INSTALL BUTTERFLY VALVES ON EACH PIPE BETWEEN TANK AND PUMP.
CONTRACTOR TO INSTALL, SEE SPECIFICATIONS.
(2) PROPOSED PUMPS CONTROL PANELS LOCATION (DUAL PUMP CONTROL PANEL, AQUIP
WATER QUALITY SYSTEM PUMP CONTROL PANEL), COORDINATE WITH OWNER AS REQUIRED.
ENCLOSURES TO BE NEMA 4X MOUNTED ON NON-GALVANIZED COATED STEEL SUPPORT WITH
CONCRETE FOOTING. ENCLOSURE TO HAVE EXTERNAL INDICATOR LIGHT FOR HIGH WATER
AND LOW WATER ALARMS.
FULL DEPTH CURB, PER CITY OF SPRINGFIELD STD DETAIL 3-5, SHEET C-301.
SPLASH PAD, PER CITY OF SPRINGFIELD STD DETAIL 4-15, C-301.
CONTRACTOR SHALL INSTALL STORM DRAINAGE HDPE PIPE AND CONNECT TO PUMP THAT
DISCHARGES TO AQUIP SYSTEM, SEE SHEET C-202 FOR PROFILE.
CONTRACTOR SHALL INSTALL CATCH BASIN TYPE 1, SEE SHEET C-202 FOR PROFILE, AND
DETAIL 5, SHEET C-302.
CONTRACTOR SHALL INSTALL CHECK VALVE VAULT, SEE SHEET C-202 FOR PROFILE, AND
SHEET C-203 FOR VALVE VAULT PLAN AND ELEVATION VIEWS.
CONTRACTOR SHALL INSTALL SAMPLING MANHOLE, SEE SHEET C-202 FOR PROFILE, AND
SHEET C-302 FOR CITY OF SPRINGFIELD STD DETAIL 4-1.
CONTRACTOR SHALL INSTALL 3/4-IN BRASS SPIGOT AT LOW POINT OF EACH DRAINAGE LINE.
CONTRACTOR SHALL INSTALL 18" DUCKBILL VALVE ON OUTFALL PIPE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
GENERAL NOTES:
1.SEE SHEET C-003 FOR OVERALL SITE TYPICAL GENERAL CONSTRUCTION NOTES AND
STANDARD EROSION CONTROL NOTES.
2.SEE SHEETS C-101 - C-101 FOR EROSION CONTROL REQUIREMENTS.
3.ALL UNDERGROUND STORM AND FORCE MAIN PIPE SHALL BE INSTALLED PER LOCAL
JURISDICTIONAL REQUIREMENTS WITH PIPE ZONE BEDDING PER DETAIL 2, SHEET C-302.
4.CLEANOUTS ARE NOT SHOWN FOR CLARITY, INSTALL CLEANOUTS AS REQUIRED, PER CITY OF
SPRINGFIELD DWG 4-4A, DWG 4-4B & DWG 4-4C, SHEET C-301.
5.EXISTING STRIPING NOT SHOWN FOR CLARITY, RESTORE PARKING LOT STRIPING AFTER
IMPROVEMENTS ARE INSTALLED, COORDINATE WITH OWNER AS REQUIRED.
6.PUMPS, CONTROL PANELS, FLOAT SWITCHES, AND GUIDERAIL SYSTEM TO BE PROVIDED BY
OWNER; CONTRACTOR IS RESPONSIBLE FOR INSTALLATION AND ALL OTHER MATERIALS
NECESSARY TO COMPLETE THE WORK AND PROVIDE OPERABLE PUMP STATIONS. Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_PLAN.dwg Layout Tab: C-201 SITE PLAN User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:23:12 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440SITE PLAN FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1107
C-201
STORM DRAIN PIPE LOCATION
NOT VERIFIED IN 2018 SURVEY
DISCHARGE
POINT DP-001
2
4
3
1
1
1
17
PROPOSED
AQUIP PUMP
6(TYP)
7(TYP)
8(TYP)
8 (TYP)
9
10
6(TYP)
16(RIP RAP)
11(TYP)
17
STORM DRAIN PIPE LOCATION
NOT VERIFIED IN 2018 SURVEY
9(2)
18
18
8 (TYP)
19
20
6" STEEL IN (W) IE UNKNOWN
6" STEEL IN (E) IE UNKNOWN
21
22
21
21
8 (TYP)
AQUIP
300S
STORAGE
TANK
439
438
437
435
434
438
4
3
8 4+005+000+000+80
0+001+002+002+60
0+00.00 PUMP-ALIGNMENT
3+61.91 SANIPAC-WQ-AL=0+001+001+40PI
0
+
4
1
.
5
0
0+000+400
+
0
0
1
+
0
0
1
+
2
0
SDMH TYPE 2 DUPLEX PUMP STATION
RIM 437.76
18" EX PVC IE 431.69 IN (S)
8" HDPE IE 433.50 IN (N)
6" HDPE (FM) IE 433.50 OUT (W)
18" HDPE (OVERFLOW) IE 434.75 OUT (NW)
SAMPLING MH
RIM 438.40
6" HDPE IE 435.50 IN (S)
18" HDPE (OVERFLOW) IE 434.30 IN (SE)
18" HDPE IE 434.30 OUT (W)
CB-02 TYPE 1 W/SOLID LID
RIM 438.06
8" DI IE 434.80 IN (NE)
8" HDPE IE 434.80 OUT (S)
CB-01 TYPE 1 W/SOLID LID
RIM 437.82
8" DI IE 435.05 OUT (SW)35 LF 8" SD DI89 LF 8" SD HDPE
83 LF 18" SD HDPE (OVERFLOW)
26 LF 18" SD HDPE
5 LF 6" SD HDPE (FM)
8 LF 6" SD HDPE (FM)
111 LF 6" SD HDPE (FM)
430
435
440
445
450
430
435
440
445
450
438.00438.000+40437.80437.80437.66437.66437.69437.691+00437.70437.70437.78437.782+00
111 LF 6" SD HDPE (FM)
SDMH TYPE 2 DUPLEX PUMP STATION
RIM 437.76
18" EX PVC IE 431.69 IN (S)
8" HDPE IE 433.50 IN (N)
6" HDPE (FM) IE 433.50 OUT (W)
18" HDPE (OVERFLOW) IE 434.75 OUT (NW)
10 LF 6" SD HDPE
STORAGE
TANK
AQUIP
90° HORIZONTAL
BEND (SEE PUMP
CROSSING PROFILE)
5 LF 6" SD HDPE (FM)
PUMP
OUTLET
BUTTERFLY
VALVE (TYP)
BUTTERFLY
VALVE (TYP)
APPROX END OF
SURVEY LIMITS
90° HORIZONTAL
BEND (SEE PUMP
CROSSING
PROFILE)
90° VERTICAL BEND, OUTFALL
INTO STORAGE TANK
CHECK VALVE VAULT,
PER DETAILS, SHEET
C-203
11 LF 6" SD HDPE (FM)
430
435
440
445
450
430
435
440
445
450
15 LF 6" SD
HDPE (FM)
0+000+40 STORAGE TANK6" SD HDPE (FM)
90° VERTICAL
BEND
90° HORIZONTAL
BEND, (SEE PUMP
ALIGNMENT
PROFILE)
90° VERTICAL
BEND
90° HORIZONTAL BEND
(SEE PUMP ALIGNMENT
PROFILE)
AREA NOT SURVEYED, EXISTING
GRADE APPROXIMATED
430
435
440
445
450
430
435
440
445
450
437.71437.710+20437.80437.80438.04438.04438.35438.35438.47438.471+00438.11438.111+20
AQUIP
DUPLEX PUMP
STATION, SEE PUMP
ALIGNMENT PROFILE
83 LF 18" SD HDPE (OVERFLOW)
@ S=0.0054
SAMPLING MANHOLE,
SEE OUTFALL
ALIGNMENT PROFILE
AQUIP OUTLET PIPE AND
OVERFLOW PER MANUFACTURER
EMERGENCY OVERFLOW AND
AQUIP OUTLET, PLUMB TO
DRAIN TO SAMPLING MANHOLE
PER MANUFACTURER
RECOMMENDATIONS.
430
435
440
445
430
435
440
445
437.85437.850+00438.01438.01438.05438.05438.37438.37438.38438.38438.17438.171+00437.88437.88437.56437.561+40
CB-01 TYPE 1 W/SOLID LID
RIM 437.82
8" DI IE 435.05 OUT (SW)
CB-02 TYPE 1 W/SOLID LID
RIM 438.06
8" DI IE 434.80 IN (NE)
8" HDPE IE 434.80 OUT (S)
DUPLEX PUMP
STATION, SEE PUMP
ALIGNMENT PROFILE
35 LF 8" SD DI
@ S=0.007289 LF 8" SD HDPE
@ S=0.0145
430
435
440
445
430
435
440
445
438.40438.400+00438.43438.43438.10438.100+60
SAMPLING MH
RIM 438.40
6" HDPE IE 435.50 IN (S)
18" HDPE (OVERFLOW) IE 434.30 IN (SE)
18" HDPE IE 434.30 OUT (W)
26 LF 18" SD HDPE
@ S=0.1062
83 LF 18" SD HDPE (OVERFLOW)
@ S=0.0054
APPROX END OF
SURVEY LIMITS
Scale 1" =
0 20'40'
20'
10'2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
RIGHT-OF-WAY DISCLAIMER
THE RIGHT-OF-WAY AND/OR PROPERTY LINES
SHOWN HEREON ARE BASED ON AVAILABLE
INFORMATION, NOT ON A SURVEYED LOCATION AND
ARE ONLY APPROXIMATE.REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_SD-PP.dwg Layout Tab: C-202 PLAN PROFILE VIEWS User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:23:39 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440PLAN PROFILE VIEWS FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1108
C-202
GENERAL DRAINAGE AND CONSTRUCTION NOTES:
1.SEE SHEET C-003 FOR OVERALL SITE TYPICAL GENERAL CONSTRUCTION NOTES
AND STANDARD EROSION CONTROL NOTES.
2.SEE SHEETS C-102 - C-101 FOR EROSION CONTROL REQUIREMENTS
3.SEE SHEET C-203 FOR STORAGE TANK, AND AQUIP 300S TYPICAL DRAWINGS
4.CLEANOUTS ARE NOT SHOWN FOR CLARITY, INSTALL CLEANOUTS AS REQUIRED,
PER CITY OF SPRINGFIELD DETAILS, DWG 4-4A, DWG 4-4B, AND DWG 4-4C, SHEET
C-301
5.SEE STORM PROFILES FOR STRUCTURE AND PIPE DATA, THIS SHEET.
6.CONTRACTOR SHALL POTHOLE AND REPORT ANY SITE DISCREPANCIES
IMMEDIATELY TO THE ENGINEER, INCLUDING, BUT NOT LIMITED TO, EXISTING PIPE
SIZE, TYPE, SLOPE AND INVERT ELEVATIONS, ROADWAY ELEVATIONS, OR
GROUNDWATER ENCOUNTERED WITHIN 3-FEET OF THE BOTTOM OF THE
FORCEMAIN AND STORMWATER CONVEYANCE SYSTEMS.
7.EXISTING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION ONLY.
8.ALL UTILITIES AND STORM CROSSINGS THAT DO NOT MEET VERTICAL CLEARANCE
REQUIREMENTS SHALL HAVE ETHAFOAM INSTALLED AT THE CROSSING, PER
DETAIL 1, SHEET C-302.
9.ALL STORM, FORCE MAIN AND DRAINAGE SYSTEM CONSTRUCTION IS SUBJECT TO
INSPECTION AND APPROVAL BY THE OWNER AND CITY OF SPRINGFIELD PUBLIC
WORKS.
10.STATION AND OFFSET ARE MEASURED FROM THE CENTER OF DRAINAGE
STRUCTURE.
HORIZ.
VERT.
Scale 1" =
0
0 20'40'
20'
5'10'2.5
10'
PUMP ALIGNMENT PROFILE
OUTFALL ALIGNMENT
OUTFALL ALIGNMENT PROFILE
PUMP
ALIGNMENT
CATCH BASIN PROFILE
PUMP CROSSING PROFILE
PUMP CROSSING
ALIGNMENT
PUMP OVERFLOW ALIGNMENT
CATCH
BASIN
ALIGNMENT
PUMP OVERFLOW PROFILE
6" STEEL IN (W) IE UNKNOWN
6" STEEL IN (E) IE UNKNOWN
6" STEEL IN (W) IE UNKNOWN
6" STEEL IN (E) IE UNKNOWN
SANIPAC WQ ALIGNMENT
2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_WQ-DT.dwg Layout Tab: C-203 PUMP VAULT STORAGE TANK AND WATER QUALITY DETAILS User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:23:52 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440PUMP, VAULT, STORAGE TANK AND WATER QUALITY DETAILS FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1109
C-203
STRAPPED TO PIPE
SUPPORT (2 PLACES)
ON TOP (NOT SHOWN)
PVC PIPE SUPPORT
DISTRIBUTION HEADER
(SEE DETAIL)
FITTINGS-FIELD FIT
DISTRIBUTION HEADER
SCH 80 PVC &
6"x6" TEE
TOP VIEW
SPRING ASSIST ACCESS
ALUMINUMINUM DIAMOND PLATE
(TYP)
PUMP STAND
(24"x36" NOM)
PUMP 2 ON
EL 431.19'
SCH 80 PVC (2 REQ'D)
PIPE SUPPORT
3"x0.75"
M/H INTERIOR
EPOXY COAT
6"Ø PUMP RISER PIPE
SUPPLIED WITH PUMP
ELECTRIC PUMP CABLE
36" MAXEL 428.69'
LOW WATER ALARM
FLOAT CONTROL, EL 428.19'
FLOAT CONTROL
PUMP OFF/TIMER OFF
PUMP 1 ON
EL 429.69'
(2) REQ'D
6"
ALUMINUM STRAP
EL 427.076"NOTES:
CROSS SECTION VIEW
PUMP (TYP)
1.MECHANICAL FLOAT ASSEMBLY SHALL BE
'ORENCO SYSTEMS MF4E' OR ENGINEER
APPROVED EQUAL, FINAL FLOAT SETTINGS
SHALL BE FIELD ADJUSTED UPON ACTUAL
FLOWS.
2.VERTICAL DATUM IS APPROXIMATE AND IS
RELATIVE TO DESIGN PLANS FOR PROPOSED
SYSTEM.
3.NOTES PERTAINING TO ELECTRICAL
CONNECTIONS FOR REFERENCE ONLY.
4.CONTRACTOR SHALL USE GASKETED JOINTS
TO MINIMIZE GROUNDWATER INTRUSION.
FLYGT SUBMERSIBLE PUMP MODEL NP3127-MT3,
ADAPTIVE 439, OR APPROVED EQUAL. 7.5 HP, 3
PHASE / 460 V, 4" DISCHARGE DIA. 410 GPM AT
35.2' TDH. (2 REQ'D, 1 LEAD / 1 LAG)
6" CONCRETE PUMP
STAND (TYP)
1"Ø PVC FOR FLOAT
MOUNTING, SECURE TO
ACCESS RISER (TYP, 2 REQ'D)
18" CONC FROM
EXISTING STORM
SYSTEM
6"Ø PVC HOSE & VALVE ASSEMBLY W/BALL & CHECK
VALVE, SCH 80 PVC, 'ORENCO SYSTEMS MODEL HV200BC
OR ENGINEER APPROVED EQUAL (TYP, 2 REQ'D)
FINISHED GRADE / PAVING,
SHALL SLOPE AWAY, ALL
DIRECTIONS (TYP)
THREADED UNION
COUPLING (2 REQ'D)
EXPLOSION PROOF ELECTRICAL SPLICE BOX
W/CORD GRIPS FOR DUPLEX PUMPS (LOCATE
@ 90° ALONG RISER CIRCUMFERENCE FROM
DISCHARGE ASSEMBLY)
INTRINSICALLY SAFE
PVC SPLICE BOX
ELECTRICAL CONDUIT
TO CONTROL PANEL
COMPACTED IMPORTED
GRANULAR MATERIAL 3/4"
MINUS CRUSHED SCREENING.
8" MIN (COMPACTED DEPTH)
CONC FILLET ALL
AROUND (TYP)
EXISTING
GROUND
WIRES TO FLOAT
ASSEMBLIES
HIGH WATER ALARM FLOAT
CONTROL, EL 434.75'3.6'± (TYP)DISCHARGE TO 6"
HDPE PRESSURIZED
TRANSPORT PIPE
6"Ø FLEXIBLE PVC
HOSE 12" LONG WITH
FITTINGS (2 REQ'D)
DISTRIBUTION
HEADER
54"Ø PUMPING CHAMBER
(TYP)
30"Ø ACCESS PORT W/SCRE
DOWN LID & VENT, "ORENCO
SYSTEMS MODEL FL30G" OR
ENGINEER APPROVED EQUAL
PUMP STATION DETAIL
NOT TO SCALE
1
C-203
EMERGENCY OVEFLOW:
CONTRACTOR TO
INSTALL OVERFLOW
OUTLET PIPE FROM
PUMP MANHOLE TO
SAMPLING MH, PER
SHEETS C-201-C-202
DOUBLE BRACE
CONNECTOR EACH END
OF CHANNEL (SEE DETAIL)
ATTACH PIPE
SUPPORT STRAP
TO WALL (TYP)
NOT TO SCALE
NOT TO
SCALE
EXISTING 18"
SD INLET INTO
NEW PUMP
MANHOLE
VALVE VAULT PLAN VIEW VALVE VAULT ELEVATION VIEW
N.T.SN.T.S8" (TYP)TO STORAGE TANK
6" PLUG VALVE
6" CHECK
VALVE
POLYMER
CONCRETE
STATION BASE
0.5'1'DISCHARGE PIPE FROM
PUMP MANHOLE
LINKSEALS
COMPRESSION
COUPLING4'5'
EXISTING
GROUND
SOLID LID FRAME
AND COVER,
TRAFFIC RATED
4'6" PLUG
VALVE
PIPE STANDS
(TYP)
AQUIP 300S TYPICAL STORMWATERx LAYOUT
WATERPROOF
NEW 8" SD INLET
INTO NEW PUMP
MANHOLE
NEW 8" SD INLET
INTO NEW PUMP
MANHOLE
2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_DT.dwg Layout Tab: C-301 TYPICAL DETAILS User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:24:04 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440TYPICAL DETAILS FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1110
C-301(MODIFIED)
THE CONTRACTOR
PBS
THE CONTRACTOR
(MODIFIED)(6-INCH MAX)(NOT TO SCALE)
2645 Willamette St, Ste AEugene, OR 97405541.686.8684PBS Engineering andEnvironmental Inc.pbsusa.comDESIGNED:
CHECKED:
Full Size Sheet Format Is 22x34; If Printed Size Is Not 22x34, Then This Sheet Format Has Been Modified & Indicated Drawing Scale Is Not Accurate.
OR
Know what's below.
before you dig.Call
R
REGISTE R E D PROFE
S
S
I
ONAL SEAN RICHARD H A N R AHANEN G I N E
E
RJ
U
NE 2 , 2 0 1179479PE
OREGON
EXPIRES: 06/30/2025
PRELIMINARY
Filename: L:\Projects\17000\17600-17699\17610 Waste Connections SW Services\17610.003_Sanipac\DWG\Sheets\17610.003_DT.dwg Layout Tab: C-302 DETAILS User: Cory Taylor CAD Plot Date/Time: 4/5/2024 12:24:10 PMSHEET ID
SHEET OF
17610.003
APR, 2024
CNT
SRH 1650 GLENWOOD BOULEVARD, EUGENE, OR 97440DETAILS FOR:90% DESIGN SANIPAC STORMWATER TREATMENT1111
C-302
ETHAFOAM PIPE ENCASEMENT DETAIL
NOT TO SCALE
C UTILITY
CROSSING
MIN
PROVIDED. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE
EXISTING UTILITY CROSSINGS IN THE EVENT THAT AN 8" SEPARATION CANNOT BE
CONTRACTOR SHALL PROVIDE ETHAFOAM PIPE ENCASEMENT AT ALL STORM AND
UTILITIES TO ANTICIPATE PROVIDING AND INSTALLING ETHAFOAM ENCASEMENTS
WHERE NECESSARY.
WIDTH
TRENCH
4" MIN.
NOTES:
CLEARANCE
LESS THAN 8"
9"
MIN.
UTILITY OR
UNDISTURBED
EARTH
18"
MIN.
NEW UTILITY
EXISTING OR
ETHAFOAM
NEW OR EXIST.
MIN.
9"
MIN.
18"
L
9" MIN.
6'
STORM CROSSING
OR STORM
CROSSINGS
ECOLOGY BLOCK
Issue Date:
File Name:
PO Box 323, Wilsonville, Oregon 97070-0323
Tel: (503) 682-2844 Fax: (503) 682-2657 oldcastleprecast.com/wilsonville
E. BLOCK
2016
020-CRBBLK ECOLOGY BLOCK
1
C-302
4
C-302
CONCRETE ECOLOGY BLOCK DETAIL
NOT TO SCALE
2
C-302
PAVEMENT RESTORATION AND PIPE ZONE BEDDING
NOT TO SCALE
3
C-302
VEGETATED SURFACE RESTORATOIN
NOT TO SCALE
36"24"18"19"5"FOR HANDLING
LIFT HOLES
CUT OUT22"32"20"CATCH BASIN
STANDARD TYPE 148"6"STANDARD
KNOCKOUT
LOCATION
CATCH BASIN TYPE 1 W/SOLID LID
NOT TO SCALE
SOLID, NO SLIPI
WATER TIGHT COVER
5
C-302