Loading...
HomeMy WebLinkAboutPlans Applicant 3/22/202412-31-2024 RIGHT SIDE ELEVATION BACK SIDE ELEVATION SCALE @ 1/8" = 1' - 0"SCALE @ 1/8" = 1' - 0" LEFT SIDE ELEVATION 5/8" X 4' X 9' T-1-11 SIDING CONT. AT BOTH FLOORS W/ APPRVD. FLASHING AND TO BE INSTALLED PER THE MFGRD. SPECS (TYP) SHEET JOB #1116 1 OF 5SITE PLANSCALE @ 1/16" = 1'ELEVATION DRAWINGSSCALE @ 1/8" = 1'- 0"REVISED: THESE DRAWINGS ARE THE PROPERTY OF: "LUKE DESIGNS" AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER EXCEPT WITH THE PROPER WRITTEN PERMISSION OF LUKE DESIGNS, INC. DATE: DRAWN BY: CHECKED BY: MONTY LUKE MARCH 22, 2024 SITE PLAN 1/16" = 1' - 0" CONCRETE/ASPHALT FLAT WORK TO BE DETERMINED AND CONFIRMED AT THE SITE BY CONTRACTOR (TYP) NOTE: ALL UTILITY HOOK-UPS TO BE DETERMINED AND CONFIRMED AT THE SITE BY THE GENERAL CONTRACTOR PER ALL LOCAL CODES (TYP) NOTE: ALL ROOF WATER RUN-OFF WILL DRAIN THRU APPROVED 3" DRAIN LINE THRU WEEP HOLES CUT INTO CITY CURBS, AND THEN INTO CITY STORM DRAIN (TYP)NEW PROPOSED ADU FOR:JEREMY & JENNIFER CROOK 1211 LORNE LOOPSPRINGFIELD, OREGON 97477JEREMY'S (M) #318-278-33783" OGEE GUTTER ON 2 X 8 FASCIA BRD. WITH APPRVD. DOWN SPOUT (TYP)NORTH287 DEADMOND FERRY RD.SPRINGFIELD, OREGON 97477541-746-7757DesignsAND ENGINEERINGFINAL PLAN 70.00' FRONT SIDE ELEVATION SCALE @ 1/8" = 1' - 0" LORN LOOP 70.00'116.11'116.11'5' (MIN)7' (MIN)12 5 12 5 12 5 12 514' (+)EXIST. HOME 10'-6" (+-) 7'-6" (+-) 12' (+-) RETAIN EXISTING CONC. PAD HERE 12 5 12 5 FLASH AND CAULK ALL WINDOW/ DOOR HEADERS WITH APPRVD. SYSTEM-CONFIRM AT SITE 1 X 3 SPRUCE TRIM (4) SIDES ALL WINDOWS AS SHOWN HERE (TYP) FLASH SIDING AT LOWER ROOF JUNCTION HERE WITH APPROVED SYSTEM (TYP) FIBERGLASS COMP. SHINGLED ROOF W/ (5) APPROVED 12" SQ. ROOF VENTS AS PER CODE (TYP) 1 X 4 CORNER TRIM AT ALL CORNERS WITH APPROVED CAULKING AS PER CODE (TYP) 36" X 36" (MIN) CONC. LANDING 8" (MAX) STEP DOWN AT EXTERIOR DR. 5/8" X 4' X 9' T-1-11 SIDING CONT. AT BOTH FLOORS W/ APPRVD. FLASHING AND TO BE INSTALLED PER THE MFGRD. SPECS (TYP)NEW R.V. GARAGE EXISTING DRIVEWAY EXISTING PORCH EXISTING PORCH 15'-0 (MAX)15'-0 (MAX) 26" 36" EXISTING APPROACH NEW CONC. APPROACHEXIST. SIDEWALK EXIST. WATER METER EXIST. LIGHT POLE EXISTING STEELE MANHOLE COVER PROPOSED NEW PAVER DRIVEWAY CONT. FROM SIDEWALK TO REAR ADU NEW WATER METER EXISTING SUB METER HERE NEW SUB METER HERE EXISTING UNDERGROUND POWER HERE TO RE-ROUTED IN NEW 3" CONDUIT ALONG THE SAME PATH (PER CODE) NOTE: POWER, WATER, SEPTIC AND WATER RUN-OFF LINE TO ALL SHARE THE SAME TRENCH AND BE SPACED HORIZONTALLY AS PER CODE NOTE: AT CURB TOP HERE = "0" ELEVATION NOTE: AT CURB TOP HERE = "0" ELEVATION NOTE: EXISTING GRADE AT REAR YARD HERE CONFIRMED TO BE 39" HIGHER THAN FRONT CURB EXISTING WOOD GATE LOCATED HERE ALL GARBAGE CANS TO BE LOCATED BEHIND GATE (TYP) EXISTING 3" DIA WEEP HOLE HERE NEW 3" DIA WEEP HOLE HERE 8'-6 (+-)