Loading...
HomeMy WebLinkAboutNotes Agency Partner 8/30/2021SPRINGFIELD UTILITY BOARD WATER SERVICE CENTER 202 South 18th Street, Springfield, OR97477-5240 Iel54l-726-2396 Fax541,-747-7348 www.subutil.com TO: Andrew Larson City of Springfield 225 N.sth Street Springfield, OR 97477 DATE: August 30,2021 SUBJECT: 811-21-002035-DWL ADU COMMENT REQUEST FOR 255 s. 49rH St. - McCarthy ADU Listed below are our comments for the above referenced development proposal: 1. The proposed development is within the Springfield city limits and currently receives water service from the Springfield Utility Board (SUB). 2. Please ask the developer to contact SUB Water Division for detailed information regarding any proposed modification of the existing water service(s) or any additional water services to the proposed development. 3. SUB and the City of Springfield are separate entities. Any water related items affecting your development will need to be coordinated through SUB Water Division independently from any items or submittals that may be required by the City. Please contad the SUB Water Division for detoiled informotion regordlng ony woter serulce(s) to the proposed development. 4. Non-residential backflow prevention assemblies are required to be installed downstream, above ground and adjacent to the waterfire/irrigation service. New non-residential water services (domestic and irrigation) require the installation of a Reduced Pressure Backflow Assembly (RPBA). 5. New residential water services with lawn sprinkler systems or other cross-connection hazards will require a Reduced Pressure Backflow Assembly (RPBA) installed above ground and at a location between a tap on the domestic service line and the irrigation system. Residential fire systems containing anti-freeze compounds or any other chemicals shall be isolated using a RPBA. lf no chemicals are used in the fire system, then a Double Check Valve Assembly (DCVA) is required. These assemblies are required to be installed above ground and at a location between a tap on the domestic service line and the fire system. 5. All non-residential domestic water, fire, and/or irrigation service(s) will require the installation of a backflow prevention assembly(ies). 7. All backflow prevention assembly design plans must be submitted to SUB Water Division for approval. For more detailed information about SUB's Cross Connection Control Program Standards contact the Water Division at54L-726-2395 or refer to SUB's website at: http://www.subutil.com/water/cross-connection- control-a nd-backf low-protection/. 8. Springfield has several wellhead protection areas. Ninety percent of Springfield's drinking water comes from wells. ln every instance, care shall be taken to prevent groundwater contamination. Contractors/developers/owners shall be responsible for the safe handling and storage of chemicals, petroleum products, fertilizers, and the prevention of groundwater and storm water runoff contamination. Special requirements may be necessary for groundwater protection at this development. For more detailed information, contact the SUB Water Division Drinking Water Source Protection Coordinator at 541-726-2396. PLEASE NOTE: SUB development charges are paid directly to SUB Water Division and SUB Electric Division. Sincerely, Springfield Utility Board - Water Ditision la