HomeMy WebLinkAboutMeeting Packet Planner 9/13/2023Completeness Check
Meeting
Development and Public Works Department
Conference Room 616 & Zoom
COMPLETENESS CHECK MEETING DATE:
Friday, September 22, 2023
11:00 a.m. - 12:00 p.m.
DPW Conference Room 616 and Zoom
Completeness Check Mtg (Site Plan Review) #811 -23 -000213 -PRE 811-23-000078-PROJ Ryan
McKillop
Assessor's Map: 17-02-31-00 TL: 501
Address: 140 S. 32" Street
Existing Use: vacant
Applicant has submitted plans for multi -building development including retail, offices, car was
and drive through
Planner: Andy Limbird
Meeting: Friday, September 22, 2023 11:00 — 12:00 via Zoom and Conference Rm 616
VICINITY MAP
811 -23 -000213 -PRE Completeness Check Meeting
17-02-31-00 TL501
140 S. 32nd Street
Ryan Mckillop
City of Springfield
Development & Public Works
225 Fifth Street
Springfield, OR 97477
SITE PLAN REVIEW — TYPE 2
SPRINGFIELD
I&
plication Type
1:1• Site Plan Review Completeness Check
❑ Site Plan Review Submittal
❑ Final Site Plan Submittal
Required Project Information (Applicant:
Applicant Name: Ryan Mckillop
Complete this Section)
Phone:541-514-4398
Company: Westgate Plaza LLC
Email:
Address: 3700 Coburg Rd Eugene, OR 97408
Applicant's Rep: Kyle Morris
Phone: 541-302-9790
Company:A & O Engineering LLC
Email: kylemorris@ao-engr.com
Address: 380 0 St Ste 200 Springfield, OR 97477
Property Owner: same as applicant
Phone:
Company:
Email:
Address:
ASSESSOR'S MAP NO: 17-02-31-00
TAX LOT NO(S): 501
Property Address (if applicable): 140 S 32nd Street Springfield, OR 97478
S
Size of Property: 4.96
o Acres
0 5 . Ft.
Units Per Acre:
Proposed Project Name: Midtown Plaza
Proposal: multi -building development including retail, office space, car -wash, and drive thru locations.
Existing Use: existing retail building on north side of the property.
New Impervious Area (Sq. Ft.): 93,329 square feet
Required Project Information (City Intake Staff:
Associated Applications:
Complete This Section)
Placard:
Case No:
Date:
Reviewed By:
Application Fee: $
Tech Fee: $
Notice Fee: $
TOTAL FEE: $
PROJECT NO:
Site Review Narrative
This narrative is for a site review application for a proposed multi -building development including retail,
office -space, carwash, and drive-thru locations. Midtown Plaza is located at the southwest corner of
Main Street and 32nd street in Springfield, Oregon. There is an existing retail building on the north end of
the site that is proposed to remain with 65 existing parking spaces. In addition, the proposal is to
construct a carwash facility that includes 21 short term vacuum parking spaces for vehicles, a drive
through coffee kiosk, and three additional office/retail buildings ranging from 3,119 square feet to 6,680
square feet.
Owner/Applicant
Westgate Plaza LLC
Attn: Ryan Mckillop
3700 Coburg Rd
Eugene, OR 97408
(541)514-4398
Applicants Representative
A & 0 Engineering LLC
Kyle Morris, PE
380 Q Street, Ste 200
Springfield, OR 97477
(541)302-9790
kvlemorris (a@ ao-ener. com
Project Location
Address: 130 S 32nd Street Springfield, OR 97478
Tax Lot: 17-02-31-00 T.L. 501
Existing Use of Site
There is an existing retail building on the north side of the property that currently houses several
businesses. The site also has 65 existing parking spaces and stormwater facilities to serve the existing
multi -tenant retail buildings. There is an existing reciprocal parking agreement with the Bob Keifer Sports
Center adjacent to the subject property.
Proposed Use
The applicant is proposing to construct two multi -tenant retail buildings and one office building ranging
from 3,119 square feet to 6,680 square feet. The proposal also includes a new coffee kiosk with drive-
thru and a carwash that includes 21 short-term vacuum spaces. There will be three shared trash
enclosures on site serving the surrounding buildings. The locations of these trash enclosures are shown
on the site plan.
The site will be accessible via an existing driveway access from 32nd street with shared access from the
Bob Keifer Sports Center. Site access is shown on the site plan.
The development is proposed to be constructed in 4 four phases. See site development plan for more
detail.
Phase 1—Crwash
2024
Phase 2— Coffee Kiosk/Drive-thru
2024
Phase 3—Multi Use -Retail Buildings
2025
Phase 4—Multi Use -Retail Buildings
2026
Land Use
The parent zone of the property is Community Commercial
The land use of the abutting properties are:
North: Light, Medium Industrial — Eastern Lane Forest Protective Association
Community Commercial — Oregon Department of Human Services
East: Community Commercial - Bahenas Family Auto Sales
South: Public Land & Open Space - Bob Keifer Sports Center
West: Community Commercial -Autozone Auto Parts
The proposed project meets the land use requirements of the development code given the abutting land
use zoning and uses.
The setbacks required for the project are 10 feet from the property lines, which have been provided in
the proposed project. See Sheet C-2.0 for reference.
Four phases are proposed as part of this development to be constructed in three years. See above table
for reference. The future development area is not included in this site review application.
Site Access — Infrastructure/Transportation —4.2
The applicant will be submitting a traffic study as part of this submittal.
No new streets are proposed as part of this submittal. There is one existing street access to the site off
32ntl Street which will be utilized for the new development. The access is proposed to remain but be
altered to a standard commercial driveway with setback sidewalk. A new catch basin is proposed to be
installed in front of the driveway to replace the existing curb inlet within the existing radii at the
driveway. There is existing access from the Bob Keifer Center on the south side of the site. There is an
existing reciprocal parking agreement with Willamalane that encourages site access from both ways.
See the project plans for more information.
Infrastructure Standards — Utilities —4.3
Grading
The proposed site will be graded to direct stormwater away from the buildings and into nearby catch
basins throughout the site. These catch basins are already connected to the public system and no new
stormwater connections to the public system are proposed. The remainder of the site will be graded to
match existing drainage patterns as well as elevations of adjacent properties.
There are no wetlands or riparian areas located on site. The proposed lot is located inside the 10-20 year
time of travel zone. Surfaces for vehicular use are proposed to be hard surface with either asphalt or
concrete. Stormwater will be directed to vegetated treatment facilities to provide pollution control prior
to leaving the site and entering the public system. The one existing swale on-site is proposed to be
reconfigured slightly and re -planted to meet current requirements. Multiple other stormwater planters
are proposed on-site to treat and detain new impervious surfaces. In all stormwater facilities infiltration
is proposed to be utilized as much as possible for discharge. Details are outlined on sheets C-3.0 and C-
4.0 and in the full stormwater report included with the submittal.
Domestic water is proposed to each of the new buildings. For each building a new water meter and
backflow device is proposed with private piping then to be constructed. The final water meter and
backflow configurations will be reviewed by SUB Water during the building permit process. See the
project plan for detailed information.
With the current fire hydrant configuration that is available to the property fire sprinkler systems are not
required on-site. No new fire hydrants or fire sprinkler systems are proposed with this project. See the
project plans for detailed information.
Existing sanitary sewers on-site are proposed to be utilized for the new buildings. No new connections to
the public system are proposed with this project. See the project plans for detailed information.
Franchise utilities (Electric, Phone, Cable, Natural Gas) are located on Sheet C5 and C6 where preferred
locations for electric, phone, cable, and gas meters to serve the development are shown. Franchise
services will be designed by the providing utility companies during the building permit process. Utilities
will be placed underground.
Landscape. Screening and Fence Standards -4.4
We are not removing more than 5 trees, therefore no tree removal permit is required
The planting plan for the site (including stormwater facilities) is outlined in the landscape sheets of the
plan set. The planting in the stormwater facilities meets the requirements outlined in the Eugene
Stormwater Management Manual. DLA prepared the landscape sheets for this submittal.
The frontage along Main Street and 32ntl Street has existing street trees that were planted during
construction and are proposed to remain.
On -Site Lighting Standards — 4.5
Lighting standards are addressed on the architectural sheets included with this submittal.
Site lighting is proposed on-site with both pole lighting and wallpack locations. Existing pole lighting is
proposed to be updated with new fixtures. See sheet E-000 for the proposed lighting on-site.
Photometrics were also prepared for this site and are included with this submittal.
Motor Vehicle Parking, Loading, and Bicycle Parking Standards —4.6
According to OAR 660-012-0440, there is no parking required in sites within 0.5 miles of a frequent
transit corrido. Therefore, there is no new parking required as part of this development. According to
LCDD 660-012-0410 Electric Vehicle Charging, new mixed-use buildings consisting of privately owned
commercial space shall require the provision of electrical service capacity, as defined in ORS 455-417, to
accommodate 40 percent of all vehicle parking spaces.
There are 65 existing spaces on site that are proposed to remain. 71 new spaces are proposed as part of
this development with 21 of these spaces being short term vacuum spaces. These spaces are intended
for temporary parking (approximately 5 minutes) while customers actively vacuum their cars, therefore
they were not considered in the EV charging space requirement calculations.
136 total spaces for the development with 6 ADA parking spaces provided.
PARKING SITE DATA
PRE -CONST
POST -CONST
Total Spaces
65
136
Total Reconfigured Existing
Spaces
-
11
Total Spaces Proposed
-
71
Total Vacuum Spaces
-
21
Total Proposed Standard Spaces
(Non -Vacuum)
-
61
Total EV Spaces Required (40%
of New S aces)
-
24
Total EV S aces Provided
-
24
Specific Development Standards —4.7
Section 4.7.100 of the Springfield Development Code is not applicable to this proposal because the
proposal fits within 4.1.100-4.6.100 standards without any special use.
Temporary Use Standards - 4.8
There are no temporary dwellings proposed as part of this development, therefore the Temporary Use
Standards in section 4.8 are not applicable to this development.
Building Elevations
Preliminary building elevations for the buildings have been included with the submission packet. See
sheets prepared by Robert Coryell Design.
Site Sign Standards
A monument sign is proposed at the entrance of the proposed site, as well as a directional site located
on the main drive. The signs on the individual businesses will be in compliance with the Springfield
Development Code.
The existing monument sign at the corner of 32ntl and Main Street is proposed to be removed and a new
monument sign for the whole development constructed. The proposed square footage of this sign is
approximately 77 square feet on each side or 154 square feet total.
For the carwash facility a monument sign (reader board) is proposed. This sign is approximately 70
square feet on each side or 140 square feet total.
An overhead entrance sign is proposed over the main drive entrance. The purpose of this sign does not
advertise any specific business on the property but add an architectural feature that is inviting to the
property.
Interior to the site a double monument sign is proposed just south of the existing bioswale. The purpose
for this sign is directional to traffic already on the property and is not intended to advertise to vehicles in
the public ROW. The approximate square footage of this sign is 85 square feet on each side or 170
square feet total.
There are also signs proposed on each building. Those are summarized on the plan sheets that were
included with the submission.
If there are any questions, please do not hesitate to contact Kyle Morris via email (kvlemorrisia@ao-
engr.com) or phone (541-302-9790).