Loading...
HomeMy WebLinkAboutMeeting Packet Planner 9/12/2023AGENDA DEVELOPMENT REVIEW COMMITTEE DEVELOPMENT SERVICES DEPARTMENT 225 FIFTH STREET Conference Room 616/ MS Teams StaffReview Tuesday, September 26, 2023 8.•30-9; OO a.m. 1. Site Plan Review 811-23-000209-TYP2 811-23-000041-PROJ Scoff Carver Assessor's Map: 17-02-30-43 TL: 6401 Address: 3654 Kathryn Ave. Existing Use: industrial -warehouse Applicant submitted plans to construct a new warehouse building Planner: Tom Sievers Meeting: Tuesday, September 26, 20238:30-9:00 virtual meeting via Microsoft Teams The Complete DRC Packet for this meeting is available online for you to review or print out from the laserfiche website: htti)://www.si)ringfield-or.gov/weblink8/browse.asi)x VICINITY MAP 811-23-000209-TYP2 Site Plan Review 17-02-30-43 TL 6401 3654 Kathryn Ave. Scott Carver City of Springfield Development & Public Works 225 Fifth Street Springfield, OR 97477 Site Plan Review SPRINGFIELD W 0#/ 111- Site Plan Review Pre -Submittal: ElMa'or Site Plan Modification Pre -Submittal, ❑ Site Plan Review Submittal: Q Ma'or Site Plan Modification Submittal: Required Project Information (Applicant. complete this section) Applicant Name: ScottCarver Phone: 503-545-4121 ❑ Company: Carver Family,LLC Email: Address: 112Timson Drive, Folsom, CA95630 Applicant's Rep.: Andrew Strout Phone: 541-746-0637 Company: Branch Engineering, Inc. Email:andrews@branchengineeringzom Address: 310 5th Street, Springfield, OR 97477 Pro ertOwner: ScottCarver Phone: 503-545-4121 Company: Carver Family,LLC Email: Address: 112 Timson Drive, Folsom, CA 95630 ASSESSOR'S MAP NO: 17-02-30-43 TAX LOT NOS : 6401 Property Address: 3654 Kathryn Avenue. Springfield, OR 97478 Size of Property: 3.13 Acres ❑x Square Feet ❑ Proposed No. of • n/a Proposed Name of Project: Description of if you are filling in this form by hand, please attach your proposal description to this application. Proposal: Construction of new warehouse building and associated parking Existing Use: HI- warehouse New Impervious Surface Coverage (Including Bldg. Gross Floor Area): 61,625 sf Si natures: Please sign and Drint Mour name and date in the acicirociriate Required Project Information (City Intake Staff., Associated Applications: box on the next complete this section) Signs: a e. Pre -Sub Case No.: Date: Reviewed by: Case No.: Date: Reviewed by: Application Fee: $ Technical Fee: $ Posta a Fee: $ TOTAL FEES: $ PROJECT NUMBER: Revised 1/7/14 10 1 of 11 anch MGINEERING- S-,,,7, August 25, 2023 WRITTEN STATEMENT CARVER FAMILY - SITE PLAN Branch Engineering Inc. Project No. 21-749 The site is located at 3654 Kathryn Avenue (TM 17-02-30-43, TL 6401). The site is 3.13 acres. The site is underdeveloped with a structure and associated vehicle circulation on the easterly 1.76 acres. The remainder of the site is undeveloped. The building is currently being used as a car repair facility. The proposal is to construct a 17,000 square foot warehouse with commercial truck loading docks, associated parking and stormwater facilities. The parking/drive area on the westerly side of the existing building will be regraded in some areas to incorporate the truck loading docks and back entrance to the new structure. The existing building will be retained for its existing purpose. A trash enclosure will be provided for the new structure as the existing structure currently has trash facilities located within the structure. The site currently has two driveway approaches to Kathryn Avenue. A third will be added near the westerly edge of the site to access the new structure's main entrance. The two existing driveway approaches will be updated with curb returns and regrading to support ADA access and compliance. Along with the private improvements, additional public improvements within the Kathryn Avenue right-of-way will be incorporated into the design. These include setback sidewalks, a stormwater runoff drainage ditch, and street trees. These will be encapsulated within an encroachment permit. The ditch will extend westerly to the 351h Street intersection to prevent rainwater pooling. The tentative site plan review application pre -submittal checklist was met in the following manner: • No phasing is planned for the development. • A seed mix and landscape notes are included on the plan set for all landscaped areas. • The architectural plan is included in the plan set. • A lighting cut sheet is included in this submittal. • All areas of the development, including the existing asphalt to remain, is to be graded to proposed drainage structures. EUGENE SPRINGFIELD ALBANY 310 Sth Street, Spnngfield, OR 97477 1 p- 541.746.0637 1 v .brancheng ine nng.mm Written Statement August 25, 2023 • A Technical Memo is included in this submittal detailing why a TIA is unnecessary for the site. • The size of the building has been reduced to allow for additional traffic circulation. • In order to allow high piled storage, the building will be sprinkled, which also removes the need for an additional hydrant. gmnch Engineenng, Inc. Page 2 of 2 aF FXO OUTDOOR LIGHTING LNC COMPACT LED LITEPAK FEATURES Compact LNC LED is designed for perimeter illumination and available in 3 lumen packages for safely, security and identity 3000 K, 4000K, 5000K and Amber color temperatures Up to 41 spacing to mounting height ratio means fewer fixtures to install Acrylic dRfuser includ ad! Use for applications near entrances or locations where reduced brig fitness is desired. (Maximum spacing with diffuser 30ft) Die-cast aluminum housing with decorative Laredo styling Full cul -off neighbor friendly Listed to UL1598 for use in wet locations SPECIFICATIONS CONSTRUCTION • Decorative the -cast aluminum housing and door • Rugged design protects internal components and prwides excellent thermal management for long life • Powder paint finishes provide lasting appearance in outdoor environments • Full cul -off distribution; Ambient diffuser included, use for applications near enlerances or locations where reduced brightness is desired OPTICS • Drivers are 120-27N, 50/60Hz Type II, III and Type IV lenses provide wide lateral spread •3000K 80 CRI,4000K-70CRI, and 5000K -70 CRI, CCT nominal • Drivers have greater then .90 power factor endless than 20% Total Harmonic Distortion Current O DATE: 4/1112023 LOCATION: 3656 Kathryn Ave TYPE U) PROIECC Carver Ste Lighting --- UICBL-U4K-3-BLSPCU am LNC -51- LNC -71- 0 W LNC -91- With diffuser INSTALLATION • Quick mount adapter provides quick installation, designed for recessed box 4' squarejunction box ELECTRICAL • 60,000 hours minimum LED life at L96 rating per IESNA TM -21-11 • Minimum operating temperature is -40•C/ -40`F • 0-10V dimming 120-277V only • LNC5L-5 LEDs, Types II, III or N available, see page 2 for electrical details • LNC7L —7 LEDs, Type II, Ill or IV available, see page 2 for electrical details • LNC9L-9 LEDs, Types II, III or IV available, see page 2 for electrical details CONTROLS • Pholocontrol option is available to provide dusk -lo -dawn control for additional energy savings CERTIFICATIONS • Listed and labeled to UL 1598 for wet locations, 25•C ambient environments WARRANTY • 5year warranty KEY DATA Lumen Range 800-2100 Wattage Range 13-22 Efficaty Range (UPM 64-95 Mixture Projected! Life(Nours) L96>60K Weights lbs.(kg)9.6(24.5) ourrentlighdrg<om/exo PewtMa awoll UCUED -Il Sw TR FXO tuTe 4/142023 LOCATION: 3654 Kathryn Ave OUTDOOR LIGHTING TYPE UI PROJECT: Carver Site Lighting LNC CATALOG, LNC-9L-U-4K3-BLSPOU COMPACT LED LITEPAK ORDERING GUIDE EKAmplix LNC-5L-U-3K-2-BLPPCU CATALWY LNO?L-U-41(3-BL PCU ORDERING INFORMATION LNC - 9L - u LNC tNCZero BL 5LED5 U 1242ZN upli?rn n 7LEDs 1 tzw 9L ?LEGS 2 208V 3 2Z 4 2 N 41, W 3000Kmninel,7(ICRI 4K 40'.gK mninel.ACRI SK 5000Kwmina.7DCRl AM Amber(590 wna"S laderor DBT Dark Brmze Ndtte TIXWral •Turtle FrIeM y/ oheaLwary Lumens applkadonS,350mA Lumens (mnseultfiesery1' Wtem 1 ahter LIN has arallala Oa IL aN 9L ibaf,mlbn; 350m4 Frosted cacti shied, ImprmN uniland,widl any 5% real PERFORMANCE DATA �ea-m Typell Nominal Wa[tage BLT B18 Mage TOtadj Typall 51 4K(4000K NOMINAL TO CRD NOMINM-70CRI) Bi BIMkGIaS Snn h Typav Lumens DBT Dark Brmze Ndtte TIXWral LPW Lumens DBS Dark Brand GloS55natth Lumens 9y5tem WaltS GTT Seatte Matte Tatural 5 0.96 LGS Lgrn Gre/Gloss Smaotd 2 1,150 PSS Platlnum5ilva5mooth 81 883 WHIT Whie Malte Tebrod - - WHS While Gbss Smmth 3 1,132 VGT Verde GreenTi tul 83 833 CC• Custom Cola BLS PCU Univewi Bil pNwceii #Of LEDs Nominal Wa[tage System mm Dist Type 51 4K(4000K NOMINAL TO CRD NOMINM-70CRI) 3K(3000K NOMINAL SO CRD AM (l nm wavelength) Lumens LPW` Lumens LPW Lumens LPW Lumens 9y5tem WaltS LPW` 5 0.96 13W 2 1,150 88.5 1,052 81 883 68 - - - 3 1,132 87 1,077 83 833 64 - - - 4 1,146 88 1,053 81 849 65 - - - 7 STO, (7AM (350ll 17 2 11515 89 11369 80.5 1,272 75 - - - 3 1,500 88 1,539 90.5 1,392 82 268 6.6 59 4 1,557 91.5 1,535 90 1,425 84 - - - 9 22W 2 2,069 2,024 94 2,033 92 1,989 92 1,588 11 1,623 72 74 - - - - - - 3 1 90 4 2,095 95 2,059 1 93.5 1 1,680 76 382 83 46 Lum¢n ralI are rmm pnpDmeYlc tests pelarmed In—rtlpnce eat, IEiNA Lill Dere ISW be reprg lathy ea the Po,laip grs shoat. ACNgI pall.... may JlNer as a r It 0 enOu%r Bmironmente'd ephitisto" bases Ponsul[ I IS filg br BW rating. PROJECTED LUMEN MAINTENANCE AmbientOPERATING I, a 40Ia. at beeJ on al nwn 0LED tal par Ili LmbJOe NOUFS Current du1fandIg111hv` O IN, 2af3 Temperature 0 25,000 ,WO Tel L96 60.000 100,000 L70(tbthe) 2l /77F 1.00 0.97 0.97 0.96 0.95 >791,000 40-C/104°F 099 0.96 0.96 0.96 0.94 >635,000 Pmfecta" per I ii Till - DI retabi the ill e,sabtl porbrmanae psal IN the LNI base madel I, a 40Ia. at beeJ on al nwn 0LED tal par Ili LmbJOe Current du1fandIg111hv` O IN, 2af3 -mahbt,....eA .,.tm..4'ae,tu...,ul.,.t t -sed. ar.aMe. �o1/I1/ e Man ro&e N we. a.m .aylieu----e —say— n L. LEDBetlwlerlBM aF FXO OUTDOOR LIGHTING LNC COMPACT LED LITEPAK ELECTRICAL DATA DATE: V11I2023 LOCATION: 365t"thgm Ave TYPE: 3 PROJECT: Carver SHE Lighting I nTni —.. LNC9L-1.4K$BL&PC1j #OF Drive Currh1dputVoIWqe 0'C Oper.Cument StemPower LEDS (mA)(Amps) 1.01 20° C (W) 9 STD.(100m0050 71F Oil 13 12 STD.p00mCO]120 120 OM 11 12 STD.(700m 120 Ono 22 LUMINAIRE AMBIENT TEMPERATURE FACTOR (LATF) Ambient Temperature Lumen Multiplier 0'C 32'F 1.02 10°C 50'F 1.01 20° C 68° F 1.00 25°C 71F 1.00 30°C 86°F 1.00 40° C 104° F 0.99 50°C 122°F 1 098 USe r11ese hears to determine rela(Ne lumen oOrpN for average ambor,ttemperatures from 0 50°C (32122°F) PHOTOMETRY ■■■■■■ ■■■■■M ■■■M■■ ■E�■■■ DIMENSIONS A c ADDITIONAL INFORMATION SNIPPING INFORMATION A B C D 4.81' 1.55' 8.22' 5.25' (122 mm) (39 mm) (209 mm) (133 mm) USE OF TRADEMARKS AND TRADE NAMES All product and company names, logos and product identifies are tratlemarks" or registered trademarks 0 of Current or their respective owners. Use ofthem does not necessarily imply any affiliation with or endorsement by such respective owners. Currents WmentlIght(EIgGOL11,9,Lf1 aepe3m3 k CIPIn3 wnnrotieeuwe�z e.n�nrvpl+W°uvucxrenn�ea,ree�naumzMamvrc LNC LED Retlmren_ea Canon Dimensions Catalog G.w(kg}/ Carton Oty. per Numb¢r CTN Lenth Width Mdeter Pack) Inch(cm) Inch (cm) Inch(cm LNC-5LU 9b (436) 14.5(31) 96)245) 1 6d (175) 2 LNC-7LU 9b (436) 14.5(37) 9.6(24.5) 6.8(115) 2 LNC-9LU 9b (436) 14.5(37) 9.6(24.5) 6.8(115) 2 USE OF TRADEMARKS AND TRADE NAMES All product and company names, logos and product identifies are tratlemarks" or registered trademarks 0 of Current or their respective owners. Use ofthem does not necessarily imply any affiliation with or endorsement by such respective owners. Currents WmentlIght(EIgGOL11,9,Lf1 aepe3m3 k CIPIn3 wnnrotieeuwe�z e.n�nrvpl+W°uvucxrenn�ea,ree�naumzMamvrc LNC LED Retlmren_ea TECHNICAL MEMORANDUM ranch ENGINEERING= DATE: August 25, 2023 PROJECT: Carver Kathryn Ave., Springfield Site Tax Lot: 6401 ��0 PKOFF Assessor's Map: 17-02-30-43 Branch Project No. 21-749GIN,g ¢#79199PE r TO: Tom Sievers, PlannerISI itally Signed City of Springfield OREGON FROM: Dan Haga, P.E. EXPIRE$: JaVE 30, 2025 RE: Site Trip Generation for TIA Applicability To document the trip generation potential associated with the proposal to improve a portion of the existing site identified on tax lot 6401 of tax assessor's map 17-02-30-43, I am providing this memorandum summarizing the projected post development site generated traffic and land use assumptions associated with the proposed improvements. The site is within City limits of Springfield and is generally located northeast of the intersection of 35'° Street and Kathryn Ave, north of existing termini at 36'° and 37m Streets. The result of this memorandum demonstrates that the proposed post -development traffic conditions do not trigger a formal traffic impact analysis review per the codified trip generation thresholds of 100 peak hour trips and/or 1,000 average daffy trips (ADT) identified in City of Springfield Development Code, section 4.2.105(B)(1) & (B)(2) for new development proposals. Existing Conditions The subject site is identified on the undeveloped/vacant portion of tax lot 6401. The developed portion of the tax lot is currently addressed as 3654 Kathryn Ave, and is developed with a building totaling approximately 17,500 square feet (17.5 thousand square feet/KSF) that is utilized for industrial uses as permitted by the City of Springfield. The existing developed and permitted industrial use is not currently planned to be significantly changed or altered with the current development proposal, except that a covered outdoor storage canopy is may be removed from the site to allow for improved vehicle maneuvering around the rear of the proposed new building. Proposed Improvements The proposed improvements include constructing a new building on the vacant portion of the land at the site with approximately 17,000 square feet (17.0 KSF) of gross building floor area that will be utilized for industrial uses and is most accurately described by an industrial park type of use as permitted in the City of Springfield's Heavy Industrial zone, per SDC Table 310 5th Street, Spnngfield, OR 97477 1 p- 541.746.0637 1 1 w .branchengineenng.com Carver Kathryn Ave Site Traffic Memo (21-749) August 25, 2023 3.2.420. As currently shown on the plan, the new building will have large bay doors at the rear fagade of the building to serve each of the three proposed tenant units, with parking at the front fagade (west side) of the building. Each unit. will be equipped with a small ancillary office area and restroom facilities. Trip Genemtion and Site Operations As described previously, the site's proposed use, and the use overall (including the existing industrial use) is most closely aligned with an industrial park type of use, which aligns best with the Institute of Transportation Engineer's (ITE's) Land Use Code 130, Industrial Parkin the current, 11'" Edition of the Trip Generation Manual. The trip generation from ITE's Land Use Code 130 -Industrial Park was applied to the gross floor area (GFA) of the proposed new building to calculate the potential trip generation with the ITE onhne web utility. The ITE Trip Generation Web utility rates are based on the published national average trip generation rates available for the category/type of use. The following table provides the potential trip generation the proposed use is projected to generate, based on the most recent ITE data available: As shown in the table, with the application of the ITE trip generation rate for an industrial park type of use applied to the proposed building gross floor area of 17,000 square feet, the new building area's use type could generate 57 average daily trips, with an estimated six of those trips generated during each the AM and PM peak hours of adjacent street traffic or seven of the trips occurring during the site's AM and PM peak hours of trip generation (peak hour of the generator). The proposed industrial park use (overall or the incremental GFA proposed with new development) is generally smaller than others that are included within the data set Branch Engineenng, Inc. Carver Kathryn Ave Site Traffic Memo (21-749) August 25, 2023 available for the ITE Industrial Park category of use, and the rates provided are average rates for the data sets included in the ITE database. Conclusion In summary, based on City of Springfield Development Code (SDC) criteria contained within SDC 4.2.105(B)(1) & (B)(2) for new development proposals, the proposal to construct a new 17,000 square -foot building to be utilized with an industrial park type of use does not require a formal traffic impact analysis review to be included, since it will not generate greater than 100 peak hour trips during any identified peak hour [SDC 4.2.105(B)(1)] and will not generate 1,000 or more average daily trips [SDC 4.2.105(B)(2)] after new development occurs and the units are fully occupied. The site generated traffic is not expected to result in any significant identifiable impacts to the existing transportation system, which would be indicated by increasing traffic that contributes to any known traffic problems in the area based on safety, speed or congestion. Please do not hesitate to contact me if I can provide any additional information, or if you prefer, we can schedule a formal meeting to discuss. Branch Engineenng, Inc.