HomeMy WebLinkAboutPermit Building 2023-08-24DLswx LOASS BUIIDRIG RISK CATEGORY 11 SEISWC [IIID DESIGN CRIJ C SEISMIC IMPORTANCE FACTOR, 1.00 MAPPED SPECTRAL RESPONSE ACCELERATION, S,B 0.672 MAPPED SPECTRAL RESPONSE ACCELERATION, Sr 0.386 SITE CLASS D SITE COEFFICIENT, u 1.263 SHORT TERM SPECTRAL RESPONSE COEFFICIENT, Sw 0.566 1 SEISMIC DESIGN CATEGORY D BASIC SEISMIC -FORGE RESISTING SYSTEM RESPONSE MODIFICATION FACTOR, R SEISMIC RESPONSE COEFFICIENT, CS ANALYSIS PROCEDURE USED 6.5, 1.5 0.087, 0.377 EQUIVALENT LATERAL FORCE PROCEDURE BASIC DESIGN WIND SPEED (mph) 98 WIND EXPOSURE C ANALYSIS PROCEDURE USED ASCE 7 CH 27 PART I INTERNAL PRESSURE COEFFICIENT 30.18 LIVE LGAD DESIGN CRITERIA i FLOOR LIVE LOAD (11 40 SNOW LCAD DESIGN CRRER61 L0 GROUND SNOW LOAD (pi It FLIT ROOF SNOW LOAD (Ji l) 9 SNOW EXPOSURE FACTOR i SNOW LOAD IMPORTANCE FACTOR I THERMAL FACTOR 1.2 SLOPE FACTOR I SLOPED ROOF SNOW LOAD (jP4 14.2 ROOF MINIMUM DESIGN SNOW LOAD (ill RAIN -ON -SNOW SURCHARGE (psf) SNOW DRIFT LOAD (MAXIMUM INTENSITY, Pill 20 5 26.2 ROOF DEAD LOAD (PFJ 10 EXTERIOR WALL DEID LOAD (pe/) 7 SPECIAL INSPECTION: 1. CONCRETE CONSTRUCTION: REM 4 OF OSSC TABLE 1705.3 GENERAL NOTES: 1, CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 2. CONDITIONS NOT SPECIFICALLY DETAILED SHALL BE IN GENERAL CONFORMANCE WITH CONSTRUCTION DETAILS OF A SIMILAR NATURE ELSEWHERE ON THE PROJECT. 3. TEMPORARY SHORING DESIGN TO BE BY CONTRACTOR. ANY EXISTING OR PROPOSED TEMPORARY SHORING ELEMENTS NOT SHOWN HERE. CONCRETE SPECIFICATIONS: 1. CEMENT.. ASTM C150 TYPE I OR 11. 1E L0 U 2. WATER: IN CONFORMANCE WITH ASTM C94. � T� 3, WATER -REDUCING ADMIXTURE ASTM Gel TYPE A. OR TYPE F w U MID-RANGE TYPE. 4. STRUCTURAL CONCRETE SHALL BE III = 4500 PSI AT 28 DAYS. VICINITY MAP SLUMP SHALL BE 41 +/- 11. SLUMPS MAY BE INCREASED TO N.T.S. B' MAXIMUM r/ APPROVED ADMIXTURE F 5. MAXIMUM WIC RATIO SHALL BE 0.47 6. AIR CONTENT 6.T 31.5,T (CONCRETE EXPOSED TO �0 FREEZING -AND -THAWING CYCLES) SHEET INDEX: 7. CONCRETE MATERIALS AND QUALITY SHALL BE IN ACCORDANCE H Q w O w MTN THE CURRENT ADOPTED VERSION OF ACI 318 'BUILDING SOOT STRUCTURAL NOTES d• CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. SIDE) DEA40ITION PIAN B. TRANSPORTATION OF RFMY-MIX CONCRETE SHALL BE IN S101 FOUNDATION PIAN Ce ACCORDANCE WITH ASTM C94 ISPECIFICAPON FOR READY -MIX S102 ROOF FRAMING PLAN SSECTION Z Ma CONCRETE' AND CONCRETE PLACEMENT, CONSOLIDATION, AND S5501 01 STRUCTURAL DETAILS CURING SHALL BE IN ACCORDANCE WITH SECTION 5 OF ACI 301 5502 STRUCTURAL DETAILS 3PEciELAT10NS FOR STRUCTURAL CONCRETE°. REVIEWED FOR 9. HOT -WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 305R "GUIDE TO HOT -WEATHER CONCRETING" AND 305.1 CODE COMPLIANCE 'STANDARD SPE FMI70N FOR HOT -WEATHER CONCRETING'. COLD -WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACReviewed plans shall Iwt be changed without rereview. 306R "GUIDE TO COLD -WEATHER CONCRETING" AND 306.1 All work regulated by cases and ordinances shall be "STANDARD SPECIFICATION FOR COLD -WEATHER CONCRETING. done in accordance with the reviewed plans. Reviewed 10. USE ASTM A615 GRADE 60 REINFORCING BARS plans shall not be cans ue ravel at any vlolatiar Revia Ble 08/24/2022 WOOD FRAMING SPECIFICATIONS: MIC IEL LINBARGE ITV OF SPRINGFIEL 1. ALL DIMENSIONAL LUMBER FRAMING IS PRESSURE TREATED 11 HF, U.N.O. 2. NEW WALL TOP PLATES MAY BE 12 OF. J. NEW GLU-LAM FRAMING TO BE COMBINATION 71, GRACE LID AC. JOB SITE MUST BE POSTED WITH ADDRESS& PERMIT NUMBER VISIBLE FROM THE STREET THE APPROVED PLANS MUST BE KEPT ON THE JOB SITE IN SUCH A WAY THAT THE" ARE EASILY LOCATED& PROTECTED FROM SHEAR WALL NOTES: WATER AND OTHER DAMAGE. 1. ALL SHEATHING MAILS REFERENCED ARE COMMON WINE NABS (I. E. 8d 0.131') VALUES OF OTHER STANDARD CONSTRUCTION FASTENERS WILL REQUIRE SPACING ADJUSTMENTS AND MUST BE APPROVED BY ENGINEER PRIOR TO USE USE HDG NAILS. 2. MINIMUM NAIL PENETRATIONS INTO SUPPORT FRAMING AT SHEATHING: Bd= 3. NAIL HEAD SHALL NOT PENETRATE THE SURFACE OF SHEATHING. 4. WALL SHEATHING SHALL BE APA RATED MARINE -GRADE C -D OR BETTER SHEATHING. 5. APPLY SHEATHING WITH LONG DIMENSIONS HORIZONTAL m I. lbsll�l W ..,..by JULY Z1 io 23 0 L0 U J � J 1 W w U J W H F W �0 SU tA } J z H Q w O w d• xH° 0NCL go Ce l7 Q Z Ma STRUCIPURAL NOTES s0oi JULY Z1 io 23 , L0 rd 23 26S STRUCIPURAL NOTES s0oi I I'-ro' REMOVE ANY REMAINING 0LLv S4W-CU1 AND REMOVE PORTION OF PORTIONS OF DAMAGED WALL ° COLUMN TO REMAIN (E) CONCRETE SAB AS REWIRED � J d TO CONSTRUCT NEW FOORNG DEREMAINING S4W-CUT AND REMOVE DAMAGED CORNER Lu PORTIONPORTIONN OF OF NORTH WALL e ° OF CONCRETE SUB PANEL AND AS ..d d V . REQUIRED TO CONSTRUCT NEW FOOTING d (E) DAMAGED d p p d .d p d COLUMN AFTER SNORING ORIGINAL POSITION OF JIREMOVE SUPPORTED BEAM DAMAGED COLUMN d S.�pUCTURq< ,��PEo �oF�, jilt R #BTL WE'A r DIGITALLY SIGNED T�5_\ OREGON 2025 W REMOVE ANY REMAINING 0LLv (E) UNDAMAGED PORTIONS OF DAMAGED WALL ° COLUMN TO REMAIN A d � J d DEREMAINING .16 � � Lu PORTIONPORTIONN OF OF NORTH WALL e ° d ' ..d d V . d d p p d .d p d F Lu d" M 0 :d d =u Vf Q w o u ° d d � -(E} 0 V 1 J x u d a GDNCRER: sue m' . W<z_. ° REMWi IXGYPi AS S40NN p Q Z n d.d - . ° ad. n. d d ° dd .a 0) d a . SOF mo&Aw Mor slow) a. d d (E) CONCRETE STAIRS ° p . DA TO REMAIN .p.....d d. UNDAMAGED ° BU ' ° .BUILDING TO REMAIN d ° d. ° (E) UNDAMAGED COLUMN TO REMAIN d �1 DBXOLMON PLAN X-9' 1 SCALE: 1 4'=7'-0' S.�pUCTURq< ,��PEo �oF�, jilt R #BTL WE'A r DIGITALLY SIGNED T�5_\ OREGON 2025 W 0LLv � J d W Lu > J WtAW F Lu M 0 =u Vf Q w o u �3 0 � =Fo 0 V 1 J x u CL w W<z_. Q Z U1>�� .., JULY .,.3o23 ax a 33$63 OEMOLTI ON PLAN S 1 U0 Ii' -f0' v Ii' -f0' TYP. AT NEW NEW FRAMED WALL 7 FOOTING AT NORTH SIDE S50 NEW 42' SO. x 12' CONCRETE TIP AT FOOTING CENTERED UNDER 2 Nom, WALL COLUMN. REINFORCE WRH (5) \ /4 AT EACH SPACING, EACH 550 WAY, AT 3' CLEAR OF BASE] COLUMN LOCATION�' � G d . ,.Qd �� bba ' SEE 5702 boor _ a a V d . c e d ° NEW CONCRETE SI AB TO MATCH (E) WHERE d C (E) SLAB IS TO aE O REMOVED. d . :a d V .° d .a. .. A a, nd a d Gbl d sT C d a c ad. n a a d c a. d d M A d a d y G d 5a 5z a �1IMMA270N PI" SIO SCALE. I/4'=Y-0" 3'-9' S.�pUCTURq< ,��PEo �oF�, a ll"t R #BTL WE'A r DIGITALLY SIGNED T�5-\ OREGON I. lbsll�l w 0 U � J d W Lu > J W tA H Lu �0 =u tA } J z Vf Q w o w �3 0 0 to 7j CL w w<z_. B zaMz_ U1>�� JULY Z1 2D23 d�ya ..a, 33'$63 70UNDATI ON PLAN J2 -4" 11'-70' NEIN FRAMED /L, 4 -4 SEEL SSOL1 W /�4 W WALL c5 NEW COLUMN c j' KNEEasily AT BRACE NEW 6x6 J2 HE PT COLUMN NEW 5p"x6 GLB - �_____—__—__—__�__— COLUMN n —N_—__—__—__�__— bb v _—__—_ IT T AT (E) KNEE BRACE - - (E) 4x6 KNEE BRACE �1 ROOF MMPL f0 SCALE: 1 NGAN4'=1'-0- 1 SJ01 - NEW 6x6 J2 LIF PT KNEE BRACE S.LpUCTURq< ,��PEo �oF�, e 4�GINgF eeMWE'f' DIGITALLY SIGNED T�5-\ OREGON 2025 w JULY Z1 2023 OJ LL FFi � J PLAN 1 W Lu J N F W U� �0 = U F } J Z V1 Q w O w �3 0 0 0 to 7j CL B zaMz_ UY>�� JULY Z1 2023 d�y... FFi ROOF FRAMING PLAN 5102 anch INE Ell 1. lbsll, tPLAN AND (E) BEAM PER PUN (E) BFAM NEW COLUMN PER PUN (E) BEAM PER PUN 0BI SI 1 Ww U >Q w(E) F lJJ M0 w 2u } J z V1 Q w O w NEW WALL FRAMING F 3 u PER DETAILS i F o 0 H 7E x CL w Q ZaMz SBCTLON U Y S70 SCALE: ,/4"=,'—O' "o°' S.�pUCTURq< ��PEo �oF GINgF `'ACL..... i JULY 2.zo�a eeeTreaPE �A rFFi 3DIGITALLY SIGNED SECTION e 9 OREGON ti l n9q�� eHEPNP�o� Rere..s:.luNE3 =5 5301 NEW COLUMN PER PLN WITHIN NEW WALL ASSEMBLY WALL ASSEMBLY PER DETAIL ABU66Z COLUMN BASE WITH !j' TITEN FFi HD ANCHOR EMBEDDED 4' MIN IN NEW CONCRETE FOOBNG. DRILL 2X6 PT BOTTOM THROUGH SLAB AS NECESSARY / I ANCHORS , . .a 2 NEW CONCRETE SLAB TO MATCH U (E), BUT 4' MIN. THICKNESS 1 o. I li�:YS > APPLY BOND BREAKER (E) CONCRETE SLJI BETWEEN NEW AND d''. a RIFY 4w MIN. (E) SLABS /W. AN . COMPACTED CRUSHED ROCK AS • PER BELOW UNDER NEW SLAB^: i `/. 0.5 REQUIRED CONCRETE FOOTING PER PUN, CENTERED UNDER NEW COLUMN = u 6' MIN. CRUSHED ROCK COMPACTED } J z TO 95% RELATIVE COMPACTION UNDISTURBED AATIVE (MODIFlED PROCTOR METHOD). SOIL. FMND EXCAVATED EXTEND 6' MIN. BEYOND EDGES OF AS NECESSARY. FOOTING. to 7E (1 COLUAOP BASH & FOOTING S50 SCALE: N.7.5. w<z_. NAIL NEW SHEATHING TO (E) RAFTER PER PANEL EDGE NAILING REQUIREMENT A34 AT EACH BLOCK (E) ROOFING It DECKING TO WALL TOP PLATE (E) RAFTER EXTEND SHEATHING AND SIDING TO UNDERSIDE OF DECKING NEW 2x6 OF BLOCKING (E) RAFTER AT 4B'o.c. DOUBLE 2x6 DF TDP PLATES NEW WALL ASSEMBLY PER DETAIL 550 SCALE: HALL TOP CONNEMON N.T.S. 2x6 12 HF PT STUDS AT 2411 WITH &WE BLOCKING AT PLYWOOD PANEL EDGES S}' MARINE GRADE PLYWOOD SHEATHING NAILED WITH BE NAILS AT Cox. AT PANEL EDGES AND 120o.c. AT REID WEATHER—RESISYIVE BARRIER FABRIC. WRAP CORNER COLUMNS }'T-1-11 SLIDING. WRAP CORNER COLUMNS a HALL ASSELLY 550 SCALE: N.i.S. (E) ROOTING & DECKING (E) TINIER (E) RAFTER CUSTOM GALVANRED SNEET METAL FLASHING III OVER EXPOSED END III W OF RBEAM EX (E) BEAM PER PLM' NOTCH SHEATHING AND SIDING AROUND BEAM LCE4Z PAIR NEW COLUMN PER PLAN n COLUAGV TOP CONNECTION S50 SCALE: N.T.S. S.�pUCTURq< ��PEo PROF R �GINgF l6TTBtPE 'A r DIGITALLY SIGNED �\ OREGON m I. lbsll�l w NEW WALL ASSEMBLY CONCRETE PAVERS OR PER DETAIL SIMILAR SURFACING �FINISHED FFi GI � 2X6 PT BOTTOM / I ANCHORS , . .a 48"1 EMBED ;dmL w U I li�:YS > p (E) CONCRETE SLJI WW a RIFY 4w MIN. THICKNESS F Lu ® (E) RAFTER EXTEND SHEATHING AND SIDING TO UNDERSIDE OF DECKING NEW 2x6 OF BLOCKING (E) RAFTER AT 4B'o.c. DOUBLE 2x6 DF TDP PLATES NEW WALL ASSEMBLY PER DETAIL 550 SCALE: HALL TOP CONNEMON N.T.S. 2x6 12 HF PT STUDS AT 2411 WITH &WE BLOCKING AT PLYWOOD PANEL EDGES S}' MARINE GRADE PLYWOOD SHEATHING NAILED WITH BE NAILS AT Cox. AT PANEL EDGES AND 120o.c. AT REID WEATHER—RESISYIVE BARRIER FABRIC. WRAP CORNER COLUMNS }'T-1-11 SLIDING. WRAP CORNER COLUMNS a HALL ASSELLY 550 SCALE: N.i.S. (E) ROOTING & DECKING (E) TINIER (E) RAFTER CUSTOM GALVANRED SNEET METAL FLASHING III OVER EXPOSED END III W OF RBEAM EX (E) BEAM PER PLM' NOTCH SHEATHING AND SIDING AROUND BEAM LCE4Z PAIR NEW COLUMN PER PLAN n COLUAGV TOP CONNECTION S50 SCALE: N.T.S. S.�pUCTURq< ��PEo PROF R �GINgF l6TTBtPE 'A r DIGITALLY SIGNED �\ OREGON m I. lbsll�l w ULY Z1 2o�a d�ya by i LL FFi ..._ � J 1 W w U > J WW H F Lu M0 = u tA } J z H Q w O w �3 0 0 to 7E CL w<z_. Q Z U1>�� STRUCTURAL DETAILS 5501 ULY Z1 2o�a d�ya by i FFi ..._ STRUCTURAL DETAILS 5501 I' MB WITH (1) BEAM PER PLN�il�NEENIXG anch STD NUT AND YY111fhG 8P1 WASHERS cross COLUMN CAP I, (E) BEAM PER PLAN sp Ll NEW LCE4Z 541 n6%3 7 PAIR h NEW KBSIZ PAIR x x AT EACH END OF (E) KNEE BRACE NEW KNEE B(E) KNEE BRACEPER MB WTM SID NUTPER PLWD BPI WASHERS NOTE NEW COLUMN til (E) COLUMN NOT ALL ERE FOR ELEMENTS SHOWN HERE FOR ADDRKNJAL PER PUN LL O v REQUIREMENTS SEE 5 I 1 �i ' B�iC�i COI NEC77ON J 550 0 SCALE: N.T.S. Q Vj i1 d7V88 MCB CONNECHON a W SCALE: N.T.S. � I•% J WW H F W MO w 2u I— } J z V1 Q w O u �3 0 � iF0 O 7E "I CL w w<v s u Q ZaMz_ U Y>, my 5 On 5 Sj Pu TURq<. ��PEo PRoF GINgF `'ACL..... i JULY Z.zo�a e 4�eeTmarE'f' rFFi DIGITALLY SIGNED STRucTUs L e 9 OREGON ti DETAILS n9q�0 eHEPNP�o� Re�was: JUNE30=5 5502