HomeMy WebLinkAboutNotes Internal Reviewers 4/28/2022LIMBIRD Andrew
From:
Sent:
To:
Subject:
Attachments:
LINBARGER Michele
Wednesday, April 27, 2022 5:37 PM
LIMBIRD Andrew
McQuillan: Children's Choice Montessori
DIM McQuillan Response.pdf
Hi Andy,
See attached for the DlM. This is a moving target with the State and these rules may change depending on when
submitted for building permits.
lru eurl-orruc SAFETY,
t tLoheLe UwbaYgeY
MIGHELE LITtgInEER
PLANS EXAMINER II
CITY oF SPRINGFIELD
225,srn STREET
SpRlNopreLD, OR 97477
MLINBARGER@SPRINGFIELDOR.GOV
P-541-736rO29
F - 54 t-72&3649
Buildins lnsoections & Safety - Citv of Sorinefield Oreson (sprinsfield-or.sov)ffi a t Please consider the environment before pranting
PUBLIC RECORDS LAW DISCLOSURE: Emails are generally public records and therefore subject to public disclosure unless
exempt from disclosure under Oregon Public Records Law.
Emails can be sent inadvertently to unintended recipients and contain confidential or privileged information. lf you are
not the intended recipient (or authorized to receive for the recipient), please advise by return email and delete
immediately without reading or forwarding to others. Thank you.
Datc fleceived
l1'-*...-- -. ,I
1
"l i ^'
CITY OF SPRINGFIELD, OREGON
DEVELOPMENT AND PUBLIC WORKS
B u i ld i n g Safety Section
225 FIFTH STREET
SPRINGFIELD, OR 97477
(541) 726-s75s
Fax (541) 726-3689
www. spri ngfi el d -or. g ov
SPRIT{GFIELD
rb
r{
April27,2022
PROJECT: Children's Choice Montessori: chanqe of use to Child Care facilitv
Address: 1942 sth St, Legal Description: 17-03-26-24-TL 3000
DIM# 81 1-22-000088-PRE & 81 1 -22-000093-PROJ McQuillan
Reviewed in accordance with:
Oregon Building Codes Division
2019 Oregon StructuralSpecialty Code (OSSC)
2009 A117.1 Accessibility Code
ls this a home that will be occupied while not being used as a daycare?
ls this a Registered or Certified facility according to the State of Oregon? This answer
identifies maximum allowed children to be served by license regulations
Accessible parking and accessible features (entrance, bathroom, etc) will be required per
ossc 1103.2.12
01.
T602 FR Rating exterior walls- separation distance: Type V-B (assumed) construction =
<5' = t hour, 5'<10'= 1-hour (Occ. B,E,l,R)
T705.8 Max area of wall openings based on fire sep distance:
3<5'= 15Yo (25o/o for R-3 occ fn d) and PROTECTED windows; sprinklered
5'<10'= 25c/olJnprotected, 25o/o sprinklered/protected (not limited for R-3 @ 5' and
greater fn f)
T716.1(3) Fire window assembly fire protection ratings:
Exterior wall assembly = 1-hr: Window min assembly rating =314-hr Fire-rated
glazing markings: OH-45 or W-60
Exterior wall assembly - 2-hr: Window min assembly rating = 1-112 hr; Fire
rated glazing markings: OH-90 or W-120
ASTM E119 or UL 263 required.
02. Current temporary rule: Jan 26, 2022, BCD Summary (attached)
lf not certified as an Oregon Licensed facility prior to this application, the rules and
requirements for sprinkler Residential-use home day care facilities are required under
2021 ORSC Sec. 101.2.1.
Date Rocelved:
[)!an:er: A.L
23,
Occupancy needs to be verified with following questions:
How many children are under care?
Ages of children?
Typical hours of operation? (24-hour?)
Group E (305 OSSC) may qualify as Group R3 if 5 or fewer children, meets 1&2-Family
code at time of construction, Section 420.11 of OSSC and ch 11 of OSSC is required to
be met.
Group l-4 (308.5.5) Child Care in a dwelling- registered or certified family childcare
facility (ORS 3294), in detached 1&2 family R-3, Sec 420.11 and Ch 11 in OSSC required
to be met.
Group R3 1 & 2 Family Home: See bulleting from BCD for Temporary Rules.
In Building Safety,
Michele Linbarger
Plans Examiner I lnspector
M Li nbarger@ spri ngfield-or.gov