Loading...
HomeMy WebLinkAboutNotes Internal Reviewers 4/28/2022LIMBIRD Andrew From: Sent: To: Subject: Attachments: LINBARGER Michele Wednesday, April 27, 2022 5:37 PM LIMBIRD Andrew McQuillan: Children's Choice Montessori DIM McQuillan Response.pdf Hi Andy, See attached for the DlM. This is a moving target with the State and these rules may change depending on when submitted for building permits. lru eurl-orruc SAFETY, t tLoheLe UwbaYgeY MIGHELE LITtgInEER PLANS EXAMINER II CITY oF SPRINGFIELD 225,srn STREET SpRlNopreLD, OR 97477 MLINBARGER@SPRINGFIELDOR.GOV P-541-736rO29 F - 54 t-72&3649 Buildins lnsoections & Safety - Citv of Sorinefield Oreson (sprinsfield-or.sov)ffi a t Please consider the environment before pranting PUBLIC RECORDS LAW DISCLOSURE: Emails are generally public records and therefore subject to public disclosure unless exempt from disclosure under Oregon Public Records Law. Emails can be sent inadvertently to unintended recipients and contain confidential or privileged information. lf you are not the intended recipient (or authorized to receive for the recipient), please advise by return email and delete immediately without reading or forwarding to others. Thank you. Datc fleceived l1'-*...-- -. ,I 1 "l i ^' CITY OF SPRINGFIELD, OREGON DEVELOPMENT AND PUBLIC WORKS B u i ld i n g Safety Section 225 FIFTH STREET SPRINGFIELD, OR 97477 (541) 726-s75s Fax (541) 726-3689 www. spri ngfi el d -or. g ov SPRIT{GFIELD rb r{ April27,2022 PROJECT: Children's Choice Montessori: chanqe of use to Child Care facilitv Address: 1942 sth St, Legal Description: 17-03-26-24-TL 3000 DIM# 81 1-22-000088-PRE & 81 1 -22-000093-PROJ McQuillan Reviewed in accordance with: Oregon Building Codes Division 2019 Oregon StructuralSpecialty Code (OSSC) 2009 A117.1 Accessibility Code ls this a home that will be occupied while not being used as a daycare? ls this a Registered or Certified facility according to the State of Oregon? This answer identifies maximum allowed children to be served by license regulations Accessible parking and accessible features (entrance, bathroom, etc) will be required per ossc 1103.2.12 01. T602 FR Rating exterior walls- separation distance: Type V-B (assumed) construction = <5' = t hour, 5'<10'= 1-hour (Occ. B,E,l,R) T705.8 Max area of wall openings based on fire sep distance: 3<5'= 15Yo (25o/o for R-3 occ fn d) and PROTECTED windows; sprinklered 5'<10'= 25c/olJnprotected, 25o/o sprinklered/protected (not limited for R-3 @ 5' and greater fn f) T716.1(3) Fire window assembly fire protection ratings: Exterior wall assembly = 1-hr: Window min assembly rating =314-hr Fire-rated glazing markings: OH-45 or W-60 Exterior wall assembly - 2-hr: Window min assembly rating = 1-112 hr; Fire rated glazing markings: OH-90 or W-120 ASTM E119 or UL 263 required. 02. Current temporary rule: Jan 26, 2022, BCD Summary (attached) lf not certified as an Oregon Licensed facility prior to this application, the rules and requirements for sprinkler Residential-use home day care facilities are required under 2021 ORSC Sec. 101.2.1. Date Rocelved: [)!an:er: A.L 23, Occupancy needs to be verified with following questions: How many children are under care? Ages of children? Typical hours of operation? (24-hour?) Group E (305 OSSC) may qualify as Group R3 if 5 or fewer children, meets 1&2-Family code at time of construction, Section 420.11 of OSSC and ch 11 of OSSC is required to be met. Group l-4 (308.5.5) Child Care in a dwelling- registered or certified family childcare facility (ORS 3294), in detached 1&2 family R-3, Sec 420.11 and Ch 11 in OSSC required to be met. Group R3 1 & 2 Family Home: See bulleting from BCD for Temporary Rules. In Building Safety, Michele Linbarger Plans Examiner I lnspector M Li nbarger@ spri ngfield-or.gov Date Recelved [)!en::er: A.l ,//>s /*>,--i-,#-