HomeMy WebLinkAboutApplication Applicant 8/4/2023City of Springfield
Development & Public Works
225 Fifth Street
Springfield, OR 97477
SPRINGFIELD
W #A,
Low Visibility, Stealth and Small Wireless Telecommunication
Facilities - Minimum Development Standards - Type 1
Required Project Information (Applicant: complete this section)
Applicant Name: T -Mobile West, LLC Phone: 503-505-4617
Company: E-mail: anna.brunkenhoefer@
Address: 960 NE ALDERWOOD ROAD, PORTLAND, OR 97002 smarU in group.com
Applicant's Rep.: Anna Brunkenhoefer, Smartlink LLC
Phone: 503-505-4617
Company: SMARTLINK
E-mail: anna.brunkenhoefer@
Address: 11044 SW Davos Lane, Wilsonville, OR 97070
Pro ert Owner:
Phone: 503-505-4817
Company: Peterson Machinery Co
E-mail:
Address: 955 Marine Blvd, San Leandro, CA 94577
ASSESSOR'S MAP NO: 0582096
TAX LOT NOS : 803031300400
Property Address: 2205 Henderson Ave, Eugene, OR 97403
Nearest
Intersection : Henderson & E. 22nd Ave. ROW ❑ Private Property
Description of If you are filling in this form by hand, please attach your proposal description to this application.
Proposal: Install an emergency back-up 501<W diesel generator on existing equipment pad and
ins a u oma is rans er Switch on existing 11 -frame a existing callsite.
ExistingUse:
Si natures: Please si n and rint our name and date in the a ro riate box on the next a e.
Associated Permits
Case No.:
Date:
Reviewed by:
Application Fee: $
Technical Fee: $
Posta a Fee: $0
TOTAL FEES: $
PROJECT NUMBER:
Revised 5/21/13 KL 1 of 14
Signatures
Owner:
The undersigned acknowledges that the information in this application is correct and accurate.
Date: 4/26/2023
Signature
Print
If the applicant is not the owner, the owner hereby grants permission for the applicant to act in his/her behalf.
Please see attached Consent letter
Date:
Signature
Please see attached Consent letter
Print
I prepared the attached plot plan and that it contains the information specified in the submit
checklist. I certify that the plot plan is accurate based upon field locates and the best
rmation. I understand that City staff will rely upon the plot plan in making any decisions
Minimum Development Standards application. I accept full responsibility and liability in the
ere are any omissions, mistakes, or inaccuracies in the plot plan.
Plot Plan
Preparation:
Date:
Plot Plan Preparer Signature
Print
Please See Attachment A to this application for general
standards applicable to all Type 1 Wireless
Telecommunications Facilities Review, and Attachment B for
standards specifically related to small wireless facilities
located within the public right of way.
Revisec 5121/13 KL 2 of 14
MINIMUM DEVELOPMENT STANDARDS —TWE I
PO08115A -Generator installation
T -Mobile West, LLC c/o Smartlink, LLC
April 26, 2023
1. PROPOSAL SUMMARY INFORMATION
APPLICANT: T -Mobile West, LLC
960 NE Alderwood Rd
Portland, OR 97002
REPRESENTATIVE: Smartlink, LLC
Anna Brunkenhoefer
Anna. brunke nhoefer(a@smartlinkerouo.com
503-505-4817
SITE ADDRESS: 2205 Henderson Ave
Eugene, OR 97403
FACI LITY OWNER: Global Signal Acquisitions IV LLC,a
Delaware limited liability company
2000 Corporate Drive, Canonsburg, PA 15317
Joe Ziegler, 724-862-7003, Joseoh.ZiealerC@crowncastle.com
REQUEST: Type 1 Application for minor modifications to the current
existing ground equipment inside of a fenced wireless facility to
install an emergency back-up power generator on existing
equipment pad and install an Automatic Transfer Switch to the
existing H -frame.
SITE DESCRIPTION: Tax Lot: 803031300400
Tax Account: 0582096
Township: 18S
Range: 3W
Section: 3
ZONING DESIGNATION: Light -Medium Industrial
PROJECT DESCRIPTION
T -Mobile West, LLC recently acquired Sprint, and is in the process of converting many of the existing
former Sprint sites into T -Mobile sites, including this one. The proposal is as follows:
Ground Equipment: Install (1) emergency back-up diesel generator on an existing equipment pad
and install (1) Automatic Transfer Switch on existing H -frame.
Tower Equipment: No proposed tower work.
Application Submittal Requirements. All applications for a WTS facility must provide the following
reports, documents or documentation:
(a) Narrative. The application must include a written narrative that describes in detail all
of the equipment and components proposed to be part of the WTS facility, including, but not
limited to, towers, antennas and arrays, equipment cabinets, back-up generators, air
conditioning units, lighting, landscaping and fencing.
Response: The current proposal includes the installation of an emergency back-up generator on
the existing equipment pad and automatic transfer switch on the existing H -Frame.
Please see responses below.
(b) Geographic Service Area. Except for small wireless facilities, the applicant must
identify the geographic service area for the proposed WTS facility, including a map showing
all of the applicant's and any other existing sites in the local service network associated with
the gap the facility is meant to close. The applicant must describe how this service area fits
into and is necessary for the service provider's service network.
Response: Not applicable. This proposal does not involve anew tower. This proposal includes a
minor modification to an existing WTS.
(c) Co -Location. An engineer's analysis/report of the recommended site location area is
required for a proposed WTS tower. For small wireless facilities in the public right-of-way, this
report is required only when a new structure is proposed. If an existing structure approved
for co -location is within the area recommended by the engineers report, reasons for not
collocating must be provided demonstrating at least one of the following deficiencies, except
for small wireless facilities which must meet the requirements in SDC 4.3.145(F)(28)(k), upon
report of an engineer or other qualified individual:
Response: Not applicable. This proposal does not involve a new tower. This proposal includes a
minor modification to an existing WTS, where T -Mobile proposed to collocate
equipment.
(d) Plot Plan. A plot plan showing: the lease area, antenna structure, height above grade
and setback from property lines, equipment shelters and setback from property lines, access,
2205 Henderson Ave, Eugene, OR 97441— P008115A Mt. Vernon
the connection point with the land line system, and all landscape areas intended to screen
the WTS facility.
Response: Drawing sheets A-1 (OVERALL SITE PLAN) and A-2 (ENLARGED SITE PLAN) reflect the
conditions at the facility. T -Mobile's proposed upgrade of the existing equipment will
not impact any existing conditions on the property.
(e) RF Emissions. An engineer's statement that the RF emissions at grade, or at nearest
habitable space when attached to an existing structure, complies with FCC rules for these
emissions; the cumulative RF emissions if co -located. Provide the RF range in megahertz and
the wattage output of the equipment.
Response: Not applicable. No changes to antennas and/or emissions associated with this
ground -work only project.
(f) Description of Service. A description of the type of service offered including, but not
limited to: voice, data, video and the consumer receiving equipment.
Response: T -Mobile offers cellular and broadband services.
(g) Provider Information. Identification of the provider and backhaul provider, if different.
Response: Comcast is the fiber provider.
(h) Zoning and Comprehensive Plan Designation. Provide the zoning and applicable
comprehensive plan (e.g., Metro Plan, 2030 Springfield Refinement Plan) designation of the
proposed site and the surrounding properties within 500 feet.
Response: The site is designated as Light Medium Industrial. Per the Springfield Comprehensive
Plan, the site is part of the Urban Growth Boundary and included in a Refinement Plan
Area.
(i) FCC, FAA or Other Required Licenses and Determinations. Provide a copy of all
pertinent submittals to the FCC, FAA or other State or Federal agencies including
environmental assessments and impact statements, and data, assumptions,
calculations, and measurements relating to RF emissions safety standards.
Response: Not applicable. This proposal does not involve anew tower. This proposal includes a
minor modification to an existing WTS.
0) Small Wireless Facilities in the Public Right -of -Way. Applications for small wireless
facilities in city limits in the public right-of-way must also include:
Response: Not applicable. This proposal does not involve anew tower. This proposal includes a
minor modification to an existing WTS that is not located in a Public Right -of --Way.
2205 Henderson Ave, Eugene, 0R 97441— POOR I15A Mt. Vernon
GENERAL STANDARDS SDC 4.3.145
(1) Design for Co -Location. All new towers must be designed to structurally accommodate the
maximum number of additional users technically practicable.
Response: Not applicable. This proposal does not involve a new tower. This WTS is already a
coloration tower. This proposal includes a minor modification to an existing WTS,
specifically the installation of an emergency back-up generator and an automatic
transfer switch. The proposed equipment installation will not increase the footprint of
the facility or defeat any concealment efforts.
(2) Demonstrated Need for New WTS Facilities. Except for small wireless facilities, applications
must demonstrate that the proposed WTS facility is necessary to close a significant gap in service
coverage or capacity for the carrier and is the least intrusive means to close the significant gap.
Response: Not applicable. This proposal does not involve a new WTS facility. This proposal
includes a minor modification to an existing WTS, specifically the installation of an
emergency back-up generator and an automatic transfer switch. The generator
installation will not increase the footprint of the facility or defeat any concealment
efforts.
(3) Lack of Coverage and lack of Capacity. Except for small wireless facilities, the application
must demonstrate that the gap in service cannot be closed by upgrading other existing facilities. In
doing so, evidence must clearly support a conclusion that the gap results from a lack of coverage
and not a lack of capacity to achieve adequate service. If the proposed WTS facility is to improve
capacity, evidence must further justify why other methods for improving service capacity are not
reasonable, available or effective.
Response: Not applicable. This proposal does not involve a new WTS facility. This proposal
includes a minor modification to an existing WTS.
(4) Identify the Least Intrusive Alternative for providing Coverage. Except for small wireless
facilities, the application must demonstrate a good faith effort to identify and evaluate less
intrusive alternatives, including, but not limited to, less sensitive sites, alternative design systems,
alternative tower designs, the use of repeaters, or multiple facilities. SDC 4.3.145(F)(5) defines the
type of WTS facilities that are allowed in each zoning district.
Response: Notapplicable. This proposal does not involve anew WTSfacility. Thisproposal
includes a minor modification to an existing WTS.
2205 Henderson Ave, Eugene, 0R 97441— P008115A Mt. Vernon
(5) Location of WTS Facilities by Type. SDC 4.3.145(E) defines various types of WTS facilities by
their visual impact. These are: high visibility, moderate visibility, low visibility and stealth facilities.
Table 4.3.2 lists the type of WTS facilities allowed in each of Springfield's zoning districts.
Response: The WTS in question is a high visibility facility (monopole). The location of the WTS in
question is zoned for Light -Medium Industrial which permits a high visibility site.
(6) Maximum Number of High Visibility WTS Facilities. No more than 1 high visibility facility is
allowed on any 1 lot/parcel.
Response: The subject WTS is the only high visibility facility on the lot/parcel.
(7) Separation Between Towers. No new WTS tower may be installed closer than 2,000 feet
from any existing or proposed tower unless supporting findings can be made under
SDC 4.3.145(F)(2), (3), and (4) by the Approval Authority.
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS.
(8) WTS Towers Adjacent to Residentially Zoned Property. In order to ensure public safety, all
towers located on or adjacent to any residential zoning district must be set back from all residential
property lines by a distance at least equal to the height of the facility, including any antennas or
other appurtenances. The setback is measured from that part of the WTS tower that is closest to
the neighboring residentially zoned property.
Response: Notapplicable. This proposal does not involve anew WiSfacility. Thispmposol
includes a ground -work only, minor modification to an existing WTS.
(9) Historic Buildings and Structures. Except for small wireless facilities, no WTS facility is
allowed on any building or structure, or in any district, that is listed on any Federal, State or local
historic register unless a finding is made by the Approval Authority that the proposed facility will
have no adverse effect on the appearance of the building, structure, or district. No change in
architecture and no high or moderate visibility WTS facilities are permitted on any building or any
site within a historic district. Proposed WTS facilities in the Historic Overlay District are also subject
to the applicable provisions of SDC 3.3.900.
Response: Not applicable. This proposal does not involve any historic buildings or structures.
(10) Equipment Location. The following location standards apply to WTS facilities, except for
small wireless facilities:
(a) No WTS facility may be located in a front, rear, or side yard building setback in any
base zone and no portion of any antenna array may extend beyond the property lines;
(b) Where there is no building, the WTS facility must be located at least 30 feet from a
property line abutting a street;
2205 Henderson Ave, Eugene, OR 97441— P008115A Mt. Vernon
(c) For guyed WTS towers, all guy anchors must be located at least 50 feet from all
property lines.
Response: Notapplicable. This proposal does not involve anew WTSfacility. Thisproposal
includes a minor modification to an existing WTS The generator is being installed on
an existing equipment pad and the switch is being installed on an existing H frame.
The installation of the generator and Automatic Transfer Switch will not increase the
size of the facility or defeat any concealment efforts.
(11) Tower Height. Towers may exceed the height limits otherwise provided for in this code.
However, all towers greater than the height limit of the base zone requires approval through a
Type 3 review process, subject to the approval criteria specified in SDC 4.3.145(1).
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS No tower work is proposed.
(12) Accessory Building Size. All accessory buildings and structures built to contain equipment
accessory to a WTS facility cannot exceed 12 feet in height unless a greater height is necessary and
required by a condition of approval to maximize architectural integration. Each accessory building
or structure located on any residential or public land and open space zoned property is limited to
200 square feet, unless approved through the Type 3 process.
Response: Not applicable. This proposal does not involve a new accessory building.
(13) Visual Impact. Except for small wireless facilities, which must meet the requirements of
subsection (F)(28), all WTS facilities must be designed to minimize the visual impact to the greatest
extent practicable by means of placement, screening, landscaping, and camouflage. All facilities
also must be designed to be compatible with existing architectural elements, building materials,
and other site characteristics. The applicant must use the least visible antennas reasonably
available to accomplish the coverage objectives. All high visibility and moderate visibility facilities
must be sited in a manner to cause the least detriment to the viewshed of abutting properties,
neighboring properties, and distant properties.
Response: Not applicable. This proposal does not involve a new WTS facility. This proposal
includes a minor modification to an existing WTS No tower work is proposed. No
concealment efforts will be defeated by the installation of the generator on the
existing equipment pad.
(14) Minimize Visibility. Colors and materials for WTS facilities must be nonreflective and
chosen to minimize visibility. Facilities, including support equipment and buildings, must be
painted or textured using colors to match or blend with the primary background, unless required
by any other applicable law.
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS No concealment efforts will be
defeated by the installation of the generator on the existing equipment pad.
2205 Henderson Ave, Eugene, 0R 97441— P008115A Mt. Vernon
(15) Camouflaged Facilities. All camouflaged VJtS facilities must be designed to visually and
operationally blend into the surrounding area in a manner consistent with existing development on
adjacent properties. The facility also must be appropriate for the specific site. In other words, it
must not "stand out' from its surrounding environment.
Response: Not applicable. This proposal does not involve a camouflaged facility.
(16) Facade -Mounted Antenna. Facade -mounted antennas must be architecturally integrated
into the building design and otherwise made as unobtrusive as possible. If possible, antennas must
be located entirely within an existing or newly created architectural feature so as to be completely
screened from view. Facade -mounted antennas must not extend more than 2 feet out from the
building face.
Response: Not applicable. This proposal does not involve any facade -mounted antennas.
(17) Roof -Mounted Antenna. Roof -mounted antennas must be constructed at the minimum
height possible to serve the operator's service area and must be set back as far from the building
edge as possible or otherwise screened to minimize visibility from the public right-of-way and
adjacent properties.
Response: Not applicable. This proposal does not involve any roof -mounted antennas.
(18) Compliance with Photo Simulations. Asa condition of approval and prior to final staff
inspection of the VJtS facility, the applicant must submit evidence, e.g., photos, sufficient to prove
that the facility is insubstantial conformance with photo simulations provided with the initial
application. If the WTS facility does not comply with the photo simulation, the applicant must
complete require any necessary modification to achieve compliance within 90 days of being
notified by the Director.
Response: Not applicable. Photo Simulations are not being provided as this proposal does not
involve a new WTS facility. This proposal includes a minor modification to an existing
KITS.
(19) Noise. Noise from any equipment supporting the VVrS facility must comply with the
regulations specified in OAR 340-035-0035.
Response: Not applicable. Per OAR 340-035-0035 (5)(a), Emergency equipment not operated on
a regular basis or scheduled basis is exempted from the noise regulations. The subject
proposal involves the installation of an emergency back-up generator and automatic
transfer switch. (Generators are tested hi-weeklyfor 15 minutes to ensure they are
functional should an emergency occur.)
(20) Signage. No signs, striping, graphics, or other attention -getting devices are permitted on
any VJtS facility except for warning and safety signage that must:
2205 Henderson Ave, Eugene, OR 97441— PO08115A Mt. Vernon
(a) Have a surface area of no more than 3 square feet;
(b) Be affixed to a fence or equipment cabinet; and
(c) Be limited to no more than 2 signs, unless more are required by any other applicable
law.
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS. Any necessary signage will meet the
applicable requirements.
(21) Traffic Obstruction. Maintenance vehicles servicing WTS facilities located in the public or
private right-of-way may not park on the traveled way or in a manner that obstructs traffic.
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS that is not located in a public or
private fightrof--way.
(22) Parking. No net loss in required on-site parking spaces may occur as a result of the
installation of any WTS facility.
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS. The existing site has adequate
space for parking outside of the compound.
(23) Sidewalks and Pathways. Cabinets and other equipment must not impair pedestrian use of
sidewalks or other pedestrian paths or bikeways on public or private land.
Response: Not applicable. This proposal does not involve a new WTS facility. This proposal
includes a minor modification to an existing WTS The WTS does not impair pedestrian
use of any nearby sidewalks, paths or bikeways.
(24) lighting. WFS facilities must not include any beacon lights or strobe lights, unless required
by the Federal Aviation Administration (FAA) or other applicable authority. If beacon lights or
strobe lights are required, the Approval Authority will review any available alternatives and
approve the design with the least visual impact. All other site lighting for security and maintenance
purposes must be shielded and directed downward, and must comply with the outdoor lighting
standards in SDC 4.5.00 unless required by any other applicable law.
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS No tower work proposed for this
ground -work only proposal.
(25) landscaping. For WTS facilities with towers that exceed the height limitations of the base
zone, at least 1 row of evergreen trees or shrubs, not less than 4 feet high at the time of planting,
and spaced out not more than 15 feet apart, must be provided in the landscape setback. Shrubs
must be of a variety that can be expected to grow to form a continuous hedge at least 5 feet in
2205 Henderson Ave, Eugene, OR 97441— PO08115A Mt. Vernon
height within 2 years of planting. Trees and shrubs in the vicinity of guy wires must be of a kind
that would not exceed 20 feet in height or would not affect the stability of the guys. In all other
cases, the landscaping, screening and fence standards specified in SDC 4.4.100 apply.
Response: Not applicable. The installation of the generator on an existing equipment pad and
the installation of the Automatic Transfer Switch on the existing H -Frame will not
affect any of the landscaping at the site nor will it defeat any concealment efforts.
(26) Prohibited WTS Facilities.
(a) Any high or moderate visibility WTS facility in the Historic Overlay District.
(b) Any WTS facility in the public right-of-way that severely limits access to abutting
property, which limits public access or use of the sidewalk, or which constitutes a vision
clearance violation.
(c) Any detached WTS facility taller than 150 feet above finished grade at the base of the
tower.
Response: Not applicable. This proposal does not involve anew WTS facility. This proposal
includes a minor modification to an existing WTS.
(27) Speculation. No application will be accepted or approved for a speculation WTS tower, i.e.,
from an applicant that simply constructs towers and leases tower space to service carriers, but is
not a service carrier, unless the applicant submits a binding written commitment or executed lease
from a service carrier to utilize or lease space on the tower.
Response: Not applicable. The is an existing WTS, additionally T -Mobile is service carrier.
(28) Small Wireless Facilities in the Public Right -of -Way. Small wireless facilities in the public
right-of-way must comply with the following standards:
Response: Not applicable. The existing WTS is neither a small wireless facility nor is it located in
the Public Rightrof-Way.
2205 Henderson Ave, Eugene, OR 97441— PO08115A Mt. Vernon
DocuSign Envelope ID: 054A9AOT-3445iE48-8CFC-3E3DAF7271F63
V CROWN
v CASTLE
GLOBAL SIGNAL ACQUISITION
Sot N. Cattleman Rd
Sarasota, FL 34232
Phone:
3025 Highland Pkwy Suite 510 :mai is
Downers Grove, It 60515 Komai.rahi rg« °m ncasue. com
an.pa��e..
VIA: email <Joe.Ziegler@crowncastle.com>
RE: BU* 879541/MT. VERNON
Site Address: 230o HENDERSON RD., EUGENE, OR 97441
Dear Joe Ziegler,
I am reaching out to you on behalf of Global Signal Acquisitions II LLC ("Lessee") to obtain your consent
as may be required by the Lease.
To better serve the public and minimize the number of tower; in an area where this property is located, T -
Mobile intends to modify its equipment at the wireless communication facility (the "Modification").
Under the Lease, Landlord's consent cannot be unreasonably withheld, conditioned or delayed. Please
provide your consent on or before April 28, 2023 by signing below and returning to
Ko mal.Tahir@crowncastle. com so that we may install T -Mobile's equipment as permitted under the Lease.
If you have any questions concerning this request, please contact Kemal Tahir at
Komal.Tahir@crowncastle.com
Sincerely,
Kemal Tahir
Real Estate Specialist II
TMO APP 579409
Agreed and accepted 4/21/2023 1 1:58:06 PM EDT
Docusigned by: (Date)
-bq
6..
(Lessor's signature)
Real Estate Specialist III
Global Signa�uisitions IV- LLC
(Lessor's name and title)
T—MOBILE SITE NUMBER: P008115A
T—MOBILE SITE NAME: MT VERNON
SITE TYPE: MONOPOLE
TOWER HEIGHT: 150'-0"
T -MOBILE PROJECT: NSD, ANCHOR
SITE INFORMATION
SITEADDRESS:
2ID5HENDER80NAVE
PROPOSED USE:
EUGENE, OR 97H1
COUNTY:
LANE
IATITUDE(NAMU
U- Q? 09317- N(44M5B2Z=)
LONGITUDE(N4 W3):
123-D21833' W (-I23.03SIM)W)
GROUND ELEVATION (NAVMU 352L5 AMSL
. URISDIGNM
CITYOFSPRINGFIELD
APIA:
0582104
ZONING :
UMI
OCCUPANCYCLASSIFKATION:
U
I LEGAL DESCRIPTION:
SEESHEEf A-1
TYPEOFCONSTRUCTGN:
V -B
PROPOSED USE:
UMAAMNED TELECOMMUNICATINS
CITY, STATE, ZIP
FACILITY
HANDICAP REQUIREMENTS:
FACILITY IS UNMANNED AND NOT FOR
COMPANY
HUMAN HABITATION. HANDICAPPED
ADDRESS
ACCESSNOTREOUIRED.
CONPANY
PETER�N MACHINERY CO
ADDRESS
RSS MARINA BLVD
CITY, STATE, ZIP
SAN LEANDRO, CA 9�7
TOWEROPERATOR
PORTLAND, OR MM
COMPANY
CROWN CASTLE USA, WC
ADDRESS
1505 WESTLAKE AVE N, SUITE 900
CITY, STATE, ZIP:
SEATTLE, GA 981 OR
APPLICANT:
PROJECTTEAM
COMPANY:
T AOBILE
ADDRESS:
833 NE HOLIADAY ST
CITY, STATE, ZIP:
PORTLAND, OR MM
CONTACT:
GERI ROPER
PHONE_
(3W)807-7230
EMAIL:
IIIIN 4�mabile.can
COMPANY: OAARTLNIC ULC
CONTACT: DAN DNTON
PHONE: (57)7563888
E-MAIL: tl iltlrlL a—ilnk9rapcm
CONSTRUCTION MANAGEMENT:
PROJECTTEAM
ARCHITECTURAL & ENGINEERING:
COMPANY:
INFINIGY ENGNERNG, PLLC
CONTACT:
ALEWNDREMATCUT
Ei AIL:
mYatoiAn y—
COMPANY: OAARTLNIC ULC
CONTACT: DAN DNTON
PHONE: (57)7563888
E-MAIL: tl iltlrlL a—ilnk9rapcm
CONSTRUCTION MANAGEMENT:
COMPANY:
CROWN CASTLE USA, NC.
ADDRESS:
150SWESTLAKEAVEN,SUITEWO
CITY, STATE, ZIP:
SEATTLE, WA 5109
CONTACT:
ERIC OSLUND
PHONE:
H503)887-0000
`E-MAIL:
mco9und®crmvrcatle.can
APPROVALS
THE FOLLOVMG PARTIES HERESY APPROVE AND ACCEPT THESE
DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED Mv1Tl
CONSTRUCTION AS DESCRIBED HERON. ALL CONSTRUCTION MCUMENTS
ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT& ANY
CHANGES OR MODIFICATIONS THEY MAY IMPOSE.
APPROVAL: SIGNATURE: DATE:
PROJECTMANAGE
SITEACOJISITION
CONSTRUCTION MANAGER
SITEOGNER
RF ENGINEER
F \
DEVELOPMENTMANAGER
W
CNSTRUCTpNMANAGE
E
OPS MANAGER
}
RMULATORYREVIEW
PROJECTMANAGER
I
CROWN CASTLE BU #:
SITE ADDRESS:
COUNTY:
JURISDICTION:
LAT: 440 02'09.30" N
879541
2205 HENDERSON AVE
EUGENE, OR 97441
LAN E
CITY OF SPRINGFIELD
LONG: 1230 02' 18.30" W
VICINITY MAP
A,
. �r•memwcolmnno�
L. T .Q
.vpenraodrvALpeQ cu..oac.e.spal
TURN LEFT ONTO NE 9TH AVE, TURN LEFT ONTO NE MULTNOMAH ST, TURN RIGHT CMO OR -W E/NE GRAND AVE, TURN LEFT ONTO NE BRO
LEFT CMO N VANCOUVER AVE, TAKE THE SLIP ROAD ON THE LEFTAND FOLLOW SIGNS FOR 1-5 SCUTA, HEAD RICAITON THESUP ROAD To
BLVD /SPRINGFIELD, TURN RIGHT ONTOGLENWOOD DR TOWARDS GLEN WOOD BLVD / SPRNGFIELD, TURN RMAIT CMO GLENGCOD BLVD,
E 22ND AVE, TURN RIGHT ONTO HENDERSON AVE, ARRIVE AT 2205 HEN GERSON AVE, EUGENE, OR OUt
PROJECT DESCRIPTION
T -MOBILE PROPOSES TO COLLOCATE ON AN EXISTING UNMANNED
TELECOMMUNICATIONS FACILITY AS FOLLOWS:
TOWER SCOPE OF WORK:
• NOTOWERSCOPEOFWORKATTHISTME
GROUNDSCOPEOFWORK:
• INSTALL A SOON DIESEL GENERATOR ON EXISTNG CONCRETE PAD
• INSTALLD'ATSONEXISTIWH-FRAME
DESIGN IS BASED ON: CROWN CASTLE APPLICATION ID WA, REV. MM
REDS VERSON N/A, DATED WA (CON FIG. N/A)
THESE PLANS HAVE BEEN DEVELOPED FOR THE CONSTRUCTION OF M
UNMANNED TELECOMMUNICATIONS FACILITY OWNED OR LEASED BY
T -MOBILE IN ACCORDANCE WTH THE PROVIDED SCOPE OF WORK,
INCORPORATED N THE PLANS BY INFINIGY. THESE PLANS ARE NOT FOR
CONSTRUCTION UNLESS STAMPED & SIGNED, &ACCOMPANIED BY A
PASSING STRUCTURAL STABILITY ANALYSIS FOR THE STRUCTURE AND
MOUNT PREPARED BY A LICENSED PROFESSIONAL ENGINEER.
CODE COMPLIANCE
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED N
ACCORDANCE MATH THE CURRENT EDITIONS OF THE FOLLOWING
CODE AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.
NOTHING IN THESE PUNS IS TO BE CONSTRUED TO PERMIT WORK NOT
CLW FORMING TO THE LATEST EDITIONS OF THESE CODE.
1. M190REGGN STRUCTURALSPECIALTYCODE(OSSC)
2. Ml OREGON MECHANICALSPECNLTYCODE(OMSC)
3. 2019OREGON FIRECODE(OFC)
4. ==OREGON PLUMBING SPECIALTYCODE(OPSC)
5. =1 OREGON ELECTRICAL SPECIALTY CODE(OEC)
8. = OREGON ENERGVEFFICIENCYSPECIAUTYODDE(OESC)
7. TIA-EN-222H OR LATEST EDITION
& NFPA 780- LIGHTNING PROTECTION CODE
9. LOCAL AMEN DMENTS TO THE ABOVE MERE APPLICABLE
10. CITY/COUNTY ORDINANCES
11. LIFE SAFETY CODE NFPA-101
T Mobffe
&A] NE HCW DAY ST
PORTLOND,OROI2A2
CROWN
v CASTLE
1505 W ESTVHE AVE N, SURE N]0
SEATTLE, WA W I W
INFINIGY8
FROM ZERO TO INFINIGY
Mw wKAldlrs w wW�ss
BELLEVUE, WA 98304
T -MOBILE SITE:
P008115A
MTVERNON
CROWN CASTLE SITE:
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
DRAWINGS ISSUED FOR
SITE .w...oOQa�m.m...
rr
F \
}
Qsrwm�rtoaww+uh
i\
.x�TANHnv�
e
`�...
Qxmkini
Qwen ven+cav
N
� r 111. P,
.vnxxQ
•xo uleuno
3
[
�a �p t
)\
TURN LEFT ONTO NE 9TH AVE, TURN LEFT ONTO NE MULTNOMAH ST, TURN RIGHT CMO OR -W E/NE GRAND AVE, TURN LEFT ONTO NE BRO
LEFT CMO N VANCOUVER AVE, TAKE THE SLIP ROAD ON THE LEFTAND FOLLOW SIGNS FOR 1-5 SCUTA, HEAD RICAITON THESUP ROAD To
BLVD /SPRINGFIELD, TURN RIGHT ONTOGLENWOOD DR TOWARDS GLEN WOOD BLVD / SPRNGFIELD, TURN RMAIT CMO GLENGCOD BLVD,
E 22ND AVE, TURN RIGHT ONTO HENDERSON AVE, ARRIVE AT 2205 HEN GERSON AVE, EUGENE, OR OUt
PROJECT DESCRIPTION
T -MOBILE PROPOSES TO COLLOCATE ON AN EXISTING UNMANNED
TELECOMMUNICATIONS FACILITY AS FOLLOWS:
TOWER SCOPE OF WORK:
• NOTOWERSCOPEOFWORKATTHISTME
GROUNDSCOPEOFWORK:
• INSTALL A SOON DIESEL GENERATOR ON EXISTNG CONCRETE PAD
• INSTALLD'ATSONEXISTIWH-FRAME
DESIGN IS BASED ON: CROWN CASTLE APPLICATION ID WA, REV. MM
REDS VERSON N/A, DATED WA (CON FIG. N/A)
THESE PLANS HAVE BEEN DEVELOPED FOR THE CONSTRUCTION OF M
UNMANNED TELECOMMUNICATIONS FACILITY OWNED OR LEASED BY
T -MOBILE IN ACCORDANCE WTH THE PROVIDED SCOPE OF WORK,
INCORPORATED N THE PLANS BY INFINIGY. THESE PLANS ARE NOT FOR
CONSTRUCTION UNLESS STAMPED & SIGNED, &ACCOMPANIED BY A
PASSING STRUCTURAL STABILITY ANALYSIS FOR THE STRUCTURE AND
MOUNT PREPARED BY A LICENSED PROFESSIONAL ENGINEER.
CODE COMPLIANCE
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED N
ACCORDANCE MATH THE CURRENT EDITIONS OF THE FOLLOWING
CODE AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.
NOTHING IN THESE PUNS IS TO BE CONSTRUED TO PERMIT WORK NOT
CLW FORMING TO THE LATEST EDITIONS OF THESE CODE.
1. M190REGGN STRUCTURALSPECIALTYCODE(OSSC)
2. Ml OREGON MECHANICALSPECNLTYCODE(OMSC)
3. 2019OREGON FIRECODE(OFC)
4. ==OREGON PLUMBING SPECIALTYCODE(OPSC)
5. =1 OREGON ELECTRICAL SPECIALTY CODE(OEC)
8. = OREGON ENERGVEFFICIENCYSPECIAUTYODDE(OESC)
7. TIA-EN-222H OR LATEST EDITION
& NFPA 780- LIGHTNING PROTECTION CODE
9. LOCAL AMEN DMENTS TO THE ABOVE MERE APPLICABLE
10. CITY/COUNTY ORDINANCES
11. LIFE SAFETY CODE NFPA-101
T Mobffe
&A] NE HCW DAY ST
PORTLOND,OROI2A2
CROWN
v CASTLE
1505 W ESTVHE AVE N, SURE N]0
SEATTLE, WA W I W
INFINIGY8
FROM ZERO TO INFINIGY
Mw wKAldlrs w wW�ss
BELLEVUE, WA 98304
T -MOBILE SITE:
P008115A
MTVERNON
CROWN CASTLE SITE:
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
EL..sLE. TITLE
SHEET
N ,ET 1 RE I-
DRAWINGS ISSUED FOR
EL..sLE. TITLE
SHEET
N ,ET 1 RE I-
A. GENERAL
1. ALL PAINT PRODUCT LINES SMALL BE SHERWIN WILLIAMS
UNLESS SPECIFICALLY NOTED OTHERWISE BYT-0gBILE.
2. CONTRACTOR SHALL PREPARE ALL SURFACES AND
APPLY ALL FINISHES PER LATEST EDITION OF
MANUFACTURER'S SPECIFICATIONS.
3. WMPLY W1TH MANUFACTURER'S WRITTEN
INSTRUCTIONS REGARDING SUFFICIENT DRYING TIME
BETWEEN MATS WITH PROVISIONS AS RECOMMENDED
CONDITIONS.
J. FHL SH COLOR AND TEXTURE OFALL PANTED SURFACES
SHALL MATCH EXISTING ADJACENT SURFACES UNLESS
OTHERWISE NOTED BYT-MOBILE.
S. ALL PAINT MATERIAL DATA SH PETS SHALL BE PROVIDED
TOTHE TMOSILECONSTRUCTKNN MANAGER.
& PREPARE PREVIW SLY PANTED SURFACE BY LIGHT
SANDING WITH <M GRIT SANDPAPER AND
MMNHYDROCARBON WASH. PREPARE GALVANIZED
SURFACES BY ACID ETCH OR SOLVENT CLEANNG N
T. PUNISH DROP CLOTHS, SHIELDS, MASKING AND OTHER
PROTECTIVE METHODS TO PREVENT SPRAY OR
DROPPINGS FROM DAMAGING ADJACENT SURFACES AND
FACILITIES.
8. APPLY PAINT BY AIRLESS SPRAY, SANDING LIGHTLY
BETWEEN EACH SUCCEEDING ENAMEL COAT ON FLAT
SURFACES. APPLYMATERIALTO ACHIEV EA COATING NO
THINNER THAN THE DRY FILM THICKNESS NDICATED.
9. APPLY BLOCK FILTER TO CONCRETE BLOCK
COMETRUCTIONANDENSURECCM
WITH FORMS COMPLETELY FILLED.
10. CONTRACTOR SHALL CORRECT RUNS, SAGS, MISSES
AND OTHER DEFECTS IWLUDNG INADEQUATE
COVERAGE AS DIRECTED BY THE T -MOBILE
CONSTRUCTION MANAGER. REPAINT AS NECESSARYTO
ACHIEVE SURFACES N
TT ARE SMOOTH, EVENLY
COATED WTH UNIFORM SHEEN AND FREE FROM
BLEMISHES.
B. PAINTINGSMPE
1. PAINT THE FOLLOWING MATERIALS AND SYSTEMS
CHECKED BELOW WITH THE COATING SYSTEM
INDICATED.
PAINTING
ORE
GO
SURFACE TO BE PAINTED
COATING
PAINT
NOT
MIA
SYSTEM
PANT
BTS UNIT
X
��CKETS, MOUNTING
MD ASSOCIATED
�RACKETS
ARDWARE CABLE AND CABLE
SEE
SEE
�.VERS EXPOSED TOVIEW,
PLANE
PLAINS
AN OFFS TC
NO MER METAL SURFACES
X
INCRETE BLOCK AND
;EMENTIOUS TYPE FINCH
X
ITYWOOD, LUMBER AND MOD
RIM INCLU DING THE BACK SIDE
X
IF ALL SCREEN MULE
.�.RETE POLES
2 1 PAINT SPECIFICATIONS
C. COATING SYSTEM SPECIFICATIONS
1. DW ACRYLICCOATNG(SERIES BB5) BY SHERWN
WILLIAMS CO. IMIL DFT PER COAT APPLIED IN TWO
COATS OVER DW BONDING PRIMER (B56450).
2. 100% ACRYLIC, IATIX COATING EW TALENT TO A-103
(SERIES A42) BY SHERWN WILLIAMS W.1 MIL DFT PER
COATAPPLIED IN TWO COATS OVER SPECIFIED PRIMER.
D. PANT&PRMER
ANTMN
EAS
• PRIMER: MEN AWA E81-WUS
• TOPCOAT:COROTHANEII1385WMMOV22
BTS CABINET
•PRIMER: KEM AWA E81-WUS
• TOPCOAT: COROTHANE II 385WMMMV22
COAXIAL JUMPER CABLES
• PRIMER: AS REWIRED FOR ADHESION. APPLY ME
COATOF KRA AQUA WATER REDUCIBLE PRIMER
E81 W25 REDUCED 25%
• TOPCOAT:2MATSMROTANEIIPOLYURETHME
BBNJ20dBMJ2
RAW STEEL
• PRIMER: KENT BOND HS EMMA, DMTACRYLIC PRIMER
• TOPCOAT:200ATSCOROTANEIIPOLYURETHANE
B85WMLBMV2
GALVANQED METAL
• ACID ETCH WITH COMMERCIAL ETCH OR VINEGAR
PRIMER COAT AND FINISH COAT (GA VITE HIGH
SOLIDS OR DW PRIMERIFNISH)
STAINLESS STEEL
• PRIMER: OTM WASH PRIMER, 871Y1
• TOPCOAT:2MATSMROTVNEIIPOLYURETHANE
B85GLMBMJ2
PRE -PRIMED STEEL
• TOUCH UP MY RUSTOR UN -PRIMED STEEL HATH KEM
BONDHS. SWGD4
ALUMINUM &MPPER
• PRIMER: DTMGASHPRlMER,B71YI
• TOPCOAT:2WATSMROTHANEIIPOLYURETHANE
B85WMLBMJ2
CONCRETEMASONRY
• PRIMER: PRO MAR EXTERIOR BLOCK FILLER
• TOPCOAT:2 COATS A-100LATEXHWSE&TRIM,
SHEEN TO MATCH
CONCRETE STUCCO (EXISTNG)
• 2COATS A-100 LATEX HOUSE &TRIM, SHEEN TO
MATCH
STUCOO
• PRIMER: PRO MAR MASONRYCONDITIONER
B-IB-WI1OM
• TOPCOAT: SUPERPANTA-M SERIES Ad9 SATIN A4A
GLOSS
WOOD
• PRIMER:A-100IXTERIORALKYDWO09DPRIMER
Y-2<WM
• TOPCOAT:2 COATS A-100 LATEXHWSE&TRIM SHEM
1. THE LATEST EDITION OF THE AMERICAN INSTITUTE OF
ARCHITECTS DOCUMENT AMI "GENERAL CONDITIONS OF
TIE CONTRACT FOR CONSTRUCTION' ARE INCLUDED N
TI ESE SPECIFICATIONS AS IF COMPLETELY
REPRODUCEDHEREN.
2. TI IS FACILITY IS AN UNOCCUPIED PCS
TELECOMMUNICATIONS SITE AND IS EXEMPT FROM ADA
ACCESS REQUIREMENTS
3. PRIOR TO SJBMISSKNN OF BIDS, THEWNTRACTORS
PARTICIPATING SHALL VBITTHEJOB SITE WITH THE
CONSTRUCTION AND CONTRACT DOWMENTS TO
CONFIRM THAT THE PROJECT CAN BE ACCOMPLISHED AS
DESIGNED HEREIN, AS WELL AS TO FAMILIARIZE
THEMSELVES
WITH ALL FIELD CONDITIONS AFFECTING
THE PROPOSED PROJECT INCLUDING DEMOLITION,
ELECTRICAL, MECHANICAL AND STRUCTURAL
INSTALLATIONS PRIOR TO PROCEEDING WITH
CONSTRUCTION. SHOULD ANY ERRORS, OMISSION, OR
DISCREPANCIES BE FOUND, THE GENERAL CONTRACTOR
SMALL IMMEDIATELYNOTIFY N WRITING, THET-MOBILE
CONSTRUCTION MANAGER AND THEARCHITECT.
J. IN TH E EVENT OF DISCREPANCIES WITHIN THESE
DRAWNGS, THE CONTRACTOR SHALL INCLUDE THE
MORE COSTLY OR EXTENSIVE NARK IN THE BID, UNLESS
SPECIFICALLYDIRECTED OTHERWISE BY T -MOBILE. IF A
DISCREPANCY EXISTS AND THE PROJECT MANAGER AND
ARCH ITECT ARE NOT NOTIFIED, THE GENERAL
CONTRACTOR SHALL BEHELD RESPONSIBLE FOR ALL
COSTS NCU FRED TO REPAIR OR CORRECT ALL
PROBLEMS THAT RESULT.
5. THESE DRAWINGS SHALL NOT BE SCALED AS THESE
DRAWINGS ARE INTENDED TO BE FOR DIAGRAMMATIC
RURPOSES ONLY. FIW RED DIMENSIONS HAVE
PRECEDENCE OVER DRAWING SCALE AND DETAIL
DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE
DRAWINGS . CONTRACTOR SHALL CHECK THEACWRACY
OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY
LOOTED, DO NOT FABRICATE ANY MATERIALS, OR BEGIN
ANYCONSTRUCTION UNTIL THE ACCURACY OF DRAWING
DIMENSKNNS HAS BEEN VERIFIED AGANSTACTUAL FIELD
DIMENSKNNS.
8. THECCNTRACTOR SHALL INCLUDE IN HIS OR HER BID
ALL MATERIALS, EQUIPMENT, APPURTENANCES AND
LABOR NECESSARY TO COMPLETE THE WORK AS
T. CONTRACTOR SHALL NOTIFY THE T -MOBILE
CONSTRUCTION MANAGER, THE PROPERTY OWNER AND
THE ARCHITECT IF ANY DETAILS ARE CONSIDERED
IMPRACTICAL, UN SJ FABLE, UNSAFE, NOT WATERPROOF,
OR NOT WITHIN CU STOMARY TRADE PRACTICE IF WORK
IS PERFORMED, IT WILL BE ASSU MED THAT THERE IS NO
OBJECTION TO ANY DETAIL. DETAILS ARE INTENDED TO
SOW THE END RESULT OF T E DESIGN. MINOR
MODIFICATIONS MAYBE REWIRED TO SUIT JOB
CONDITIONS, AND SHALL BE INCLUDED AS PARTOF THE
WORK.
8. EXISTING ELEVATIONS AND LOCATIONS SHALLBE
VERIFIED BY THE CONTRACTOR BEFORE
CONSTRUCTION .IF THEY DIFFER FROM THOSESHONN
M THE PLANS, THE CONTRACTOR SHALL NOTIFYTHE
T -MOBILE CONSTRUCTION MANAGER PND THE
ARCHITECT SO THAT MODIFICATIONS CAN BE MADE
BEFORE PROCEEDING WITH THE NARK
9. TH E CONTRACTOR SHALL VERIFY ALL TELEPHONE&
RADIO EQUIPMENT LAYOUTS, SPECIFICATIONS,
PERFORMANCE, N STALLATION AND FINAL LOCATIONS
WITH T -MOBILE CONSTRUCTION MANAGER PRIOR TO
BEGINNING WORK. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR COORDINATING ALL WORK WITH
ERICSSON RADIO SYSTEMS.
10. ALL SYMBOLS& ABBREVIATIONS U SED ON THESE
DRAWNGS ARECONSIDERED CONSTRUCTION
STANDARDS. IFTHECCNTRACTOR HAS QUESTIONS
REGARDNG THEIR EXACT MEANNG, THETMOBILE
CONSTRUCTION MANAGER AND THE ARCHITECT SHALL
BE NOTIFIED FOR CLARIFICATION BEFORE THE
11. THECCMRACTOR SHALL OBTAIN AND PAY FOR ALL
PERMITS, LICENSES AND INSPECTIONS NECESSARY FOR
PERFORMANCE OF THE WORK AND INCLUDE THOSE IN
THECOSTOFT ENARKTOT MOBILE.
1 1 GENERAL SPECIFICATIONS
12. THE CONTRACTOR SHALL PROVIDECONTNUMJS
SUPERVISION AND DIRECTALL WORK VWILE MY
SUBCONTRACTORS OR WORKERS ARE ONSITE, USING
HIS OR HER BEST SKILL AND ATTENTON. THE
CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL
CONSTRUCTION MEANS,METHODS,TECHNIOUES,
PROCEM RES, SEQUENCES, AND COORDINATION OF ALL
PORTS OF THE CONTRACTED WORK.
13. WORKMANSHIP THRWOHWT SHALL BE OF THE BEST
QUALITY OF THE TRADE INVOLVED, AND SHALL MEET OR
EXCEED THE FOLLOWING MN IMUM REFERENCE
STANDARDS FOR WALT' AND PROFESSIONAL
CONSTRUCTION PRACTICE:
ARCA -NATIONAL ROOFING CONTRACTORS ASSOCIATION
O'HARE INTERNATIONAL CENTER
10255 W HIGGNS RD, SUITE OM
ROSEMONT IL 6O3165M7
SMACNA - SHEET METAL AND AIR CONDITIONING
CLVJTMCTORS NATIONAL ASSOCIATION
4M1 IAFAYETTE CENTER DR
CHANTILLY, VA MISI-1219
IILP- INTERNATIONAL INSTITUTE FOR IATH AND PIASTER
820 TRANSFER RD
ST. PMOL, MN 5511 N405
14. INSTALL ALL EUIPMENT AND MATERIALS PER THE
LATEST EDITION OF THE MANUFACTURER'S
INSTALLATION SPECIFICATIONS UNLESS OTHERWISE
INDICATED BYT-MOBILE, OR NH ERE LOCAL CODES OR
REGULATIONS TAKE PRECEDENCE.
I& THE CONTRACTOR SHALL VERIFY, COORDINATE, AND
PROVIDE ALL NECESSARY BLOCKING, BACKING,
FRAMING, HANGERS OR OTHER SUPPORTS FOR ALL
ITEMIS.
I& THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL
GIVE ALL REWIRED CONSTRUCTION NOTICES AND
SHALL COMPLY WTH ALL APPLICABLE LOCAL CODES,
RE•'UTATICNS, LAWS AND ORDINANCES, AS WELL AS THE
STATE DEPARTMENT OF INDUSTRIAL RELATIONS
RE•'ULATICNS, INC W DING BUT NOT LIMITED TO THE
DIVISION OF OCCUPATIONAL SAFETY AND HEALTH
(OSHA).
17 THE CONTRACTOR SHALL PROTECT ALL PROPERTY
FROM DAMAGE THAT MAY OCCUR DURING
CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING
FINISHES, CON STRUCTION, STRUCTURE LANDSCAPING,
CURBS, STAIRS, OR EW IPMENT, ETC. SHALL BE
IMMEDIATELY REPAIRED OR REPLACED TO THE
SATISFACTION OF T -MOBILE AND THE PROPERTY
OWNER'S REPRESENTATIVE AT THE EXPENSE OF THE
CONTRACTOR.
18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND
SHALL REPLACE OR REMEDY, ANY FAULTY, IMPROPER,
OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY
DAMAGE WHICH SHALL APPEAR WITHIN ME YEAR AFTER
THE COMPLETION AND ACCEPTANCE OF THE WORK BY
19. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR TO PROTECT AND LWATE OR CONTACT
AN OUTSIDE AGENCY TO LOCATE, ALL EXISTING
UTILITIES REGARDLESS OF METH ER OR NOT SHOWN
HEREN. THE CONTRACTOR BALL BEAR ALL EXPENSES
FOR THE REPAIR OR REPLACEMENT OF UTILITIES OR
OTHER PROPERTY MMAGED N CONJUNCTION WITH THE
EXECUTION OF WORK.
M. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
COMPLETE SECURITY OF THE PROJECT SITE WHILE THE
.OB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED
AND ACCEPTED BY T MOBILE
21. THE CONTRACTOR SHALL PROVIDE TEMPORARY WATER,
POWER AND TOILET FACILITIES AS REWIRED BYTHE
PROPERTY OWNER, T -MOBILE, AND THE CITY OR
MVERNINGAGENCY.
23. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR
REDLINING THE CONSTRUCTION DOW MENTS TO
ILLUSTRATE THE AS -MILT CONDITION OF TH E SITE. THIS
SHALL BE DONE AFTER THE SITE HAS BEEN AWARDED
FINAL INSPECTION BY THE RESPONSIBLE BUILDING
AGENCY ONE SET OF REDLN ED DRAWINGS SHALL BE
PROVIDED TO THE TMOBILE CONSTRUCTION MANAGER.
M. THE LATEST EDITION OF ALL PERMITTED AND APPROVED
PLANS PERTAINING TO THIS PROJECT SHALL BE KEPT IN
A PLAN BOX AND SHALL NOT BE USED BY WORKERS. ALL
CONSTRUCTION SETS SHALL REFLECT THESAME
NFORMATION. THE CONTRACTOR SHALL ALSO MANTAIN
N GOOD CONDITION, ONE COMPLETE SET OF PUNS
WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS
ON THE PREMISES AT ALL TIMES. THESE ARE TO BE
UNDER THE CARE OF THE CONSTRUCT"
SUPERINTENDENT.
2C. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND
WASTE MATERIALS ON A DAILY BASIS, EXCEPT FOR THAT
SPECIFIED AS THE PROPERTY OF THE BUILDNG OR
PROPERTY OWNER AND SHALL EXERCISE STRICT
CONTROL OVER SITE CLEANING THR W OH W T
MNSTRUCTION AND FINAL CLEAN-UP UPON
COMPLETION OF WORK. ALL AREAS ARE TO BE LEFT IN A
BROOM CLEAN CONDITION AT THE END OF EACH MY
THEN AT A VACUUM CLEAN CONDITION, FREE FROM
PAINT SPOTS, MST OR SMUDGES OF MY NATURE AT
COMPLETION OF NARK.
25. TH E GEN ERAL CONTRACTOR MUST PERFORM WORK
DURING PROPERTY OWNER'S PREFERRED HWRS TO
AVOID DISRU PTINN OF NORMAL ACTIVITY.
M. ALL EXPOS ED METAL SHALL BE HOT -DIPPED
GALVANIZED.
P. SEAL ALL PENETRATIONS THROUGH FIRERATED AREAS
WITH U.L. LISTED OR FIRE MARSHALL APPROVED
MATERIALS IF AND WHERE APPLICABLE TO THIS FACILITY
AND PROJECT SITE.
M. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH
RATING OF LOUT LESS TNN 2-A OR NIOBC WITHIN 75
FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE
PROJECT AREA UNDER CONSTRUCTION.
M. ELECTRICAL POWER SYSTEM SHALL BE GRWN DED PER
NEC ARTICLES 2M AND 810.
M. ALLNEWOPENINGSNTHEEXTERIORENELOPEOF
CONDITIONED SPACES SUCH AS AT WALL AND ROOF
PENETRATUN S SHALL BE CAULKED OR SEALED TO LMIT
INFILTRATION OF AIR AND MOISTURE.
31. UPONCOMPLETIONOFCCNSTRUCTIOMTAOBILE
CONSTRUCTION MANAGERSHALLCONDUCTA
WALK-THRU HATH PROPERTY OWNER OR
REPRESENTATIVE OF PROPERTY OWNER.
32. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
MAINTAINING ALL SYSTEM MOMENT IN A CLEAN
WORKING ORDER UNTIL ACCEPTANCE OF THE PROJECT
BYT MOBILE.
M. NSTALLALLEWIPMENTMI)MATERNLSPERTHE
LATEST EDITION OFTHE MANUFACTURER'S
INSTALLATION SPECIFICATIONS UNLESS SPECIFICALLY
OTHERWISE INDICATED, OR WHERE LOCAL CODES OR
REGULATION TAKE PRECEDENCE.
T Mobffe
AM NE HOLLADAY ST
FOWLAND,OROI2A2 ®�
CROWN
v CASTLE
1505 W ESTVHE AVE N, SUITE MO
SEATTLE, WA W1 W
INFINIGYB
FROM ZERO TO INFINIGY
M wKAi w w .X
BELLEVUE, WA 08334
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
E... SPECIFICATIONS
& NOTES
E�.�aT 2 AEW1�
DRAWINGS ISSUED FOR
E... SPECIFICATIONS
& NOTES
E�.�aT 2 AEW1�
2 NOT USED
A. GENERAL
1. PRECEDENCE: UNLESS OTHERVASE SHOWN OR
SPECIFIED, THE FOLLOWNGGENERAL NOTES SHALL
APP LY. INFORMATION ON THESE DRAWINGS SHALL HAVE
THE FOLLOWING PRECEDENCE.
A. ALL GIVEN SKNJ S TO TAKE PRECEDENCE OVER
SCALE SHOWN ON PUNS, SECTIONS AND DETAILS
B. NOTES AND DETAILS ON DRAWNGS SHALL TAKE
PRECEDENCE OVER GENERAL NOTES AND TYPICAL
DETAILS.
C. MATERIAL NOTES AND SPECIFICATIONS ON THE
DRAWINGS SHALL TAKE PRECEDENCE OVER THE
SPECIFICATIONS.
1 OTHER TRADES: SEE THE ARCHITECTURAL DRAWINGS
FOR ALL DIMENSIONS NOT SHOWN.
1 GENERAL DETAILS AND NOTES ON THESE SHEETS SHALL
APPLY UNLESS SPECIFICALLY SHOWN OR NOTED
OTHERWISE CONSTRUCTION DETAILS NOT FULLY
SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS
SHOWN FOR SIMILAR CONDRION S.
J. SHORING: IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO INSTALL ALL TEMPORARY BRACNG
AND SHORING TO IN SJ RE THE SAFETY OF THE WORK
UNTIL IT IS COMPLETED. THE INCLUDES UNDERPINNING
EXISTING FOOTINGS WHERE APPLICABLE.
5. SAFETY: TH ESE DRAWINGS REPRESENT THE FINISHED
STRUCTURE. UNLESS OTHERWISE INDICATED, THEY DO
NOT INDICATE THE METHOD OF CONSTRUCTION.
6. WATERPROOFING: WATERPROOFING AND DRAINAGE
DETAILS OR SPECIFICATIONS SHOWN N THESE
DRAWINGS
ARE FOR GENERAL INFORMATIONAL
PURPOSES ONLY. CONTRACTOR TO N'JTIFY THE
T -MOBILE CONSTRUCTION MANAGER AND THE
ARCHITECT IF ANY INADEQUATE OR IMPROPER
CONDITIONS.
& STEEL
1. ALL STRUCTURAL STEEL SECTIONS AND WELDED PLATE
MEMBERS SHALL CONFORM TO ASTM A -M AND BE
FABRICATED IN ACCORDANCE WITH THE SPECIFICATIONS
OF THE AISC.
2. ALL BOLTS SHALL CONFORM TO ASTM A-307 UN LESS
OTHERWISE NOTED ON PLANS. HIGH STRENGTH BOLTS
SHALL CONFORM TO ASTM A-325
1 STEEL PIPE COLUMNS SHALL BE GRADE"B"
CONFORMNGTOASTMA53.
J. STEELTUBINGSHA LBEGRADE-B"CONFORMINGTO
ASTM A503,
5. ALL WELDING SHALL BE DON E BY THE SHIELDED ARC
METHOD. ALL WELDERS SHALL BE PROPERLY QUALIFIED
AND BE PRE -APPROVED. SURPLUS METAL SHALL BE
DRESSED OFF TO SMOOTH, EVEN SURFACESNHERE
WELDS ARENOT EXPOSED TO VIEW. ALL WELDNG SHALL
COMPLYWITHTHEIATESTAWS.SPECIFICATIONS.
6. THEFOLLOWINGWELDINGEQUIPMENTMJSTBEUSED:
A. 250AMPWELDERS.
& ROD OVENS.
C. GRINDERS.
T. NO BUII BOXES SHALL BE USED.
S. ALL STRUCTURAL STEEL SHALL HAVE MILL
CERTIFICATION. MILL CERTIFICATKNN SHALL BE KEPT ON
THE JOB SITE FOR EXAMINATION BYTHE DESIGN
ENGINEER AND THE CITY INSPECTOR.
9. ALL HIGH STRENGTH BOLTS SHALL HAVE MILL
CERTIFICATION. MILL CERTIFICATION SHALL BE KEPT ON
THE JOB SITE FOR EXAMINATION BY THE INSPECTOR.
10. STEEL THAT HAD BEEN WELDED, CUT OR SCRATCHED
THE FIELD SHALL BE TOUCHED UP WITH COLD
GALVANIZNG PAINT.
11. WELDINGINDIOATMINTMEDMWINGSISDESIGNED
FOR ONE HALF OF ALLOWABLE CODESTRESSO UNLESS
NOTED"FULLSTRESS"ATENDOFWELDSYMBOL.
C. CONCRETE
1. STRENGTH: CONCRETE FOR THE PROJECT SHALL HAVE
THE FOLLOWING ULTIMATE COMPRESSIVE STRENGTH AT
AGEOF28DAYS:
LOCATION STRENGTH WT. SLUMP ADMIXTURE
SLAB&FOOTING XLMps 1M,f <" NONE
1 INSPECTION CONCRETE WITH SPECIFIED STRENGTH
GREATER THAN 2509psi SHALL BE CONTINUOUSLY
INSPECTED DURING PLACEMENT BY A DEPUTY
INSPECTOR EMPLOYED BY TESTING LABORATORY
APPROVED BY THE BU LDING DEPT.
1 REBARGRADES: REINFORCING STEEL SHALL BECUMN
PREFORMED BARS CONFORMING TO ASTM A615 AS
FOLLOWS
W &SMALLER BARS_._. _.._ GRADE40
Y5&LARGER BARS__. _.. GRADEW
ALL BARS AT CAISSON FOOTING _ GRADE W
13ANCHORING ALL REINFORCING STEEL,
DRAWINGS ISSUED FOR
DOWELS, IN SERTS, ETC , L BE WELL SECURED IN
POSITION PRIOR TO ONCRETE NO
..O14�ALL DUTS,
RAYED ING CONCRETE
TMobile�USED
ON CONCRETE MERE TILE OR FLOOR COVERING
AM RE HOLLADAY ST0
TO BE SON DED TO THE CONCRETE SURFACE SHALL BEAPPROVED
I
By THE TILE OR FLOOR COVERINGMANUFACTURER
KEEPSIUABWETFOR7DAYMINIMUMPERIOD
15. CONSOLIDATION: ALL CONCRETESHALL BERATED AS
R IS BEING PLACED WITH ELECTRICALLY OPERATED
VIBRATING EQUIPMENT
D. TIMBER
1. ALL FRAMING LUMBER FOR 4X AND LARGER BEAMS
SHALL BEN0.1 GRADE DOUGLAS FIR., S45, UNLESS
N'JTEDOTHERMSE
J. FOUNDATIONS&SLABS: TYPEV,LOWALKAU, 1 ALL FRAMING LUMBER FOR 2X RAFTERS AND MISTS
CLWFORMINGTOASTMC150. PIERMAISSONFOOTINGS: SH0.LBEN02GRADEOUGLASFIR,S/,UNLESS
WPEV,LOWALKALI,CONFORMNGTOASTMC-150. NOTEDOTHERMSE
5. AGGREGATE : USEDINTHECONCRETESHALLCONFORM
TO ASTM C 3M. USEONLYAGGREGATES KNOWN NOT TO
CAUSE EXCESSIVESHRNKAGE. THE MAXIMUM SIZE
AGGREGATE N CONCRETE WORK SHALL BE THE
FOLLOWING:
A. FOUNDATIONS&SLABS 9 -OR LESS: YP'GRAVEL
B. PIEWCAISSONFOOTNG: 1"GRAVEL.
6. SHALL BE CLEAN AND FREE FROM DELETERIOUS
AMOUNT OF ACIDS, ALKALIS, ORGANIC MATERIALS AND
SHALL BE SUITABLE FOR HUMAN CONSJMPTKNN.
]. MIXING: PREPARATION OFCOHCRETE SHALL CONFORM
TO ASTM CW. NO MORE THAN W MINUTES SHALL
ELAPSE BETWEEN CONCRETE BATCH NG AND CONCRETE
PLACEMENT UNLESS APPROVED BYA TESTNGAGENCY.
8. SEGREGATION OF AGGREGATES: CONCRETE SHALL NOT
BE FLOPPED THROUGH REINFORCING STEEL HAS N
WALLS, COLUMNS, CAISSON, AND DROP CAPITALS) SO AS
TO CAUSE SEGREGATION OF AGGREGATES. USE
HOPPERS, CHUTESTRUNKS OR PUMP HOSE SO THAT
THE FREE UNCONFINED FALL OF CONCRETE SHALL NOT
EXCEED 5 FT.
9. SPLICES OF REINFORCING STEEL SHALL BE LAPPEDA
MINIMUM OF M DIAMETERS AND SECURELY WIRED
TOGETHER. SPLICES OF ADJACENT REINFORCING BARS
SHALL BE STAGGERED WHEREVER POSSIBLE.
10. REAR CLEARANCE: MINIMUM COVERAGE FOR JOISTS,
BEAMS, GIRDERS AND COLUMNS SHALL BE TO FACE OF
STIRRUPS OR TIES. UNLESS OTHERWISE NOTED,
CONCRETE COVERAGE FOR REINFORCING BARS TO
FACE OF BAR SHALL BE AS FOLLOWS:
A. CONCRETE IN CONTACT WITH EARTH, UNFORMED 3'
B.CCNLRETEINCCMACTWITHEARTH,FORMED T
C. WALL, EXTERIOR FACE 1-1YY
D. WALL, INTERIOR FACE 1"
E. STRUCTURALSIABS 11"
F. MISTS 1P'
G. BEAMS. GIRDERS&COLUMNS 1-1T'
11. PENETRATIONS: NO SLEEVES OR CHASES SHALL BE
PLACED IN BEAMS, SLABS, WALLS AND COLUMN
EXCEPTTHOSE SHOWN ON THE PLANS. CONTRACTOR
SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATIONS OF
ANY ADDITIONAL SLEEVES OR CHASES. ALL PLUMBING,
ELECTRICAL AND MECHANICAL OPENINGS SHALL BE
SLEEVES. CORING IS NOT ALLOWED UNLESS PRIOR
12. EMBEDDED ITEMS: CONDUIT PLACED N A CONCRETE
SLAB SHALL NOT HAVE AN OUTSIDE DIAMETER GREATER
THAN 114 THE THICKNESS OF THE SLAB. CON CUT SHALL
NOT BE EMBBEDED N A SLAB THAT IS LESS THAN 3-1a'
THICK, UNLESS SLAB IS LOCALLY THICKEN ED. MINIMUM
CLEAR DISTANCE BETWEEN CCUN W RS SHALL BE SIX
INCHES.
1 1 STRUCTURAL SPECIFICATIONS
STRIPPING, BLOCKING, BACKINGANDOTHER
STIR GRADE DOUGLAS FIR, S�2X4 STUD WALUS SMALL
4ALL BEAMS, MISTS AND RAFTERS SMALL BE INSTALLED
VMTH CROWN SIDE Up
& ROOF PLYWOOD SMALL MATCH EXISTING PLYWOOD
SHEATHINRS WITH A SPAN INDEX RATIO =16 EDGE NAIL
FIELD NAIL WITH 8dAT 12, OC
* PLYWOOD SHEETS SMALL BE LAID WITH THE FACE GRAIN
PERPENDICULAR TO SUPPORTS AND WITH THE EDGES
STAGGERED, UNLESS NOTED OTHERWISE ON THE
* PLYWOOD SMALL BE GRADE MARKED BY DFPA, TECO, OR
PTI. AND SMALL CONFORM TO PS 1-0
* THE MAXIMUM MOISTURE CONTENT OF ALL LUMBER
SMALL NOT EXCEED N% AT THE TIME OF INSTALLATION
9MIN IMU M NAILING SHALL COMPLY WITH TABLE �11 OF
BUILDING CODE. ALL NAILS SMALL BE COMMON WRE
NAILS
10ALL BOLTS SMALL HAVE STANDARD CUT WASHERS
UNDER HEADS ANNOR NUTS MERE IN CONTACT WITH
WOOD
I I LAG BOLTS SHALL BE SCREWED IWO PLACE, NOT
DRIVEN LAG BOLTS SMALL BE INSTALLED IN
PRE -DRILLED HOLES MATH A DIAMETER EOUAL TO 75%
DIAMETER OF BOLT
12 CONNECTORS ALL SHEETMETALFMMING
CONNECTORS SHOWN V THE PLANS SHALL BE STRONG
CUNN ECTORS AS MANUFACTURED By THE SAMWN
COMPANY WESTITUTIONSMAYBEMADEWHEN
APPROVED BY TH E STRUCTU RAL ENGINEER
1 � ALL LUMBER EXPOSED TO WEATH BE OR IN COfITACT
MATH MASONRY OR CONCRETE SHALL BE WOLMANIZED
RESISTANT LUMBER SUCH AS REDWOOD OR CEDAR
14. ALASKAN YELLOW CEDAR GLUE -LAMINATED BEAMS
A. LUMBERSPECIES: AIASKANYELLOWCEDAR(ACL
CONFORMNGTOMRV12
B. STRENGTH PROPERTIES:
Fb BOTTOM FIBER BENDING STRESS 2100mm MIN.
Fb TOP FIBER BENDING STRESS 1000ps MN.
Fv SHEAR STRESS 190ps MIN.
Fc COMPRESSION STRESS PERPENDICULAR TO
GRAN 560p4 MIN.
C. MODULUS ELASTICITY 14MMi MIN.
D. CAMBER TO RADIUS OF 1600"U ON.
E. ALL GLB'S SHALL BE FABRICATED WITH EXTERIOR
GLUE.
F. MANUFACTURE OF GLB'S SHALL CONFORM TO THE
UBC.
G GLULAM MATERIAL SHALL BE IN ACCORDANCE WITH
ANSVAITC AI9CIANDASTMD3M7.
CROWN
v CASTLE
1505 W ESTVXE AVE N, SURE MO
SEATTLE, WA 9B1 W
INFINIGY8
FROM ZERO TO INFINIGY
Ew wKAleTrs w wW�ss
BELLEVUE, WA BBYJ!
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
«..n< SPECIFICATIONS
& NOTES
DRAWINGS ISSUED FOR
I
AM
«..n< SPECIFICATIONS
& NOTES
E 22N DAVE
49
IXISTNGTREE(NP� �\�
1 1 OVERALL SITE PLAN
I / I
I I
J 1
I I
F------ --
I I
I
I 1 I
I1
I
I
I � I
I
I II
I
I
I
I
1
WITHIN EXISTING CRO WN CASTLE
COMPOUND(SEESHEETA-4
LEGAL DESCRIPIIIXJ:
NOT PROVIDED
I
_ I
E 22ND AVE
I I
I 1
I I
I I
I I
1
I
E%ISTNO PROPS LINE, I
TYP. (APPROXIMATE)TES
I
I
1
I
I
01
T Mobile
ASO NE HCW DAY ST
FORTLOND, OR OI2A2
CCROWN
v CASTLE
1505 W ESTVHE AVE N, SURE MO
SEATTLE, WA SAIRS
INFINIGY8
FROM ZERO TO INFINIGY
M» wlWbns w wWRss
BELLEVUE, WA
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
E�..�.E. OVERALL
SITE PLAN
,EA 1 AE 1�
I
AM
E�..�.E. OVERALL
SITE PLAN
,EA 1 AE 1�
PROPOSM7,M MLEATS EMS NGUTILITY
ONEXSTINGMFRA 14F 1ME
2 (ENLARGED EQUIPMENT PLAN
i
EXISTNGCRONN CASTLE
19-11'135-5'FENCED WMPWND
X— X— X—X—X—% X—X—X—X—X—X—
1 ENLARGED SITE PLAN
T Mobffe
kb NE HCW DAY ST
FORTLOND, OR OI2A2 CRCO®�
�9 N
v VAS tlTLE
1505 W ESTVHE AVE N, SURE W0
SEATTLE, WA SSI W
INFINIGY8
FROM ZERO TO INFINIGY
M» wlWbns w MWRss
BELLEVUE, WA
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
I— —EENLARGED
SITE PLANS
«.�a2 AE.1�
I
I
/
!
IXISTNGT-MOBILE
UIILITYI4FRAME
I
iy
INGRESS
'.
EGRESS
'
EXISTNGCRONN
iCASTLEMMOPOLE
'
�
I
I
I
�' ]'WORHCLEARANCE
I
AROUND PROPOSED
x
', FMOEILE 50kW DIESEL(
I
i GENERATOR
x
I
EXISTING S'A E'
TMOBILE EWIPMEEF
x
LEASEAREAWIIHN
EXISTING CROM
CASTLE COM POUND
PROPOSEDT-WBILE 5MW
MESEL GENERATOR
I
%
I
�
I
1
INGRESS
EGRESS
I
�
EERXISTING UTILITY
H-PRPME RYPJ
�X-_x-X-x-X-x
-X_X_X_X_X_X_X_X�
1 ENLARGED SITE PLAN
T Mobffe
kb NE HCW DAY ST
FORTLOND, OR OI2A2 CRCO®�
�9 N
v VAS tlTLE
1505 W ESTVHE AVE N, SURE W0
SEATTLE, WA SSI W
INFINIGY8
FROM ZERO TO INFINIGY
M» wlWbns w MWRss
BELLEVUE, WA
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
I— —EENLARGED
SITE PLANS
«.�a2 AE.1�
1 1 1EXISTING SOUTH ELEVATION ,Y,rs ;;, _;Q .
2 PROPOSED SOUTH ELEVATION
T Mobile
ASO NE HCW DAY ST
PORTLAND, OF 9I CRCO®�
�9 N
v VAS tlTLE
1505 W ESTVHE AVE N, SURE MO
SEATTLE, WA SAIRS
INFINIGY8
FROM ZERO TO INFINIGY
M» wlWbns w wW�ss
DELLEVUE, WA 9moa
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
E..s.E. SOUTH
ELEVATIONS
�.�aA.3 AE1a
50050
OENERAC- Rnlcunmla�
appllcation and englneering dala
[xRIMYWnkA'i
a'el
--wNAYn
fra[�b'mM
GENERAC- INDUSTRIAL
RRIIIIIIIII
S0050
xsa
�u
operaling data (60Hz(
POWRR PAllx65 (N W]
,E�x�,EA-4
nwN
. Ps
¢n
Sifx Y
nn.uaaN.aNeemK
u
Nx r.an�
Ra Sao Ps I+
RR f.+Fr Rn:e
LP pbm N'S
iYiMe�•
[
Tan➢bYe Nuiiq`�
2slill
LY1el
lu '. I I
fi
acpMlm I tµu. h.l
ax w
Nwx uxNNe
vsoo
m {+1
Ifi11
I....
L n hmv 4 • vnllq�
•-4-1_ cw
SvvRT-mmpnd
an
xv Pu4
3R
M
52
I'.
mAM +MpPo
i
I hi,
¢NinOei Xea]Tras
a •�
iYMe
FM Su6FWpn
Ian
w Tm
f..l bli- 1I' tC "umi
FM1l0l,1 9p^ry.v
f�.,
MGN6
��
<s lexul
Wrp
F�Fm-srffFq.,�q
r-. a l••�'m�•V.^i
PmRenYn�MunMmRwmi
Rml
1.5'A�6[plunn
Ln [I.n-ul i•eeem
sn wn m
]pnr
PH111YthMIrll NerrhM
PPM
SI ties Iw.
pe Y O+fa
.e Ped[
su pv
mEns ilpv; aE 4eedMr
GIMryGby
W
OI Rer Ma
RI
ful Rpw
Pe !
VNf
„ . IRaLp.I
13.6 um npwl
'0°
cls+e raNMy
um<n,vnn
sMlws.ae
�1.5'na
sadanrtdnp lNVJGuIpAI
'f 1Y
Rwtlw
lNGINf
,it�Jap Y6iM
N�iOM�(W.Puex
Twa' NamniMCSN'mnhn
ru�mD
asme R<nem �
wex�P 7
vmnPa Np�ON[int
OPPGNMNhiRAwARPA IXMkINNL[MNMRMPLIPfAB
xfMffi
NIM ]1P
IkS B}Yd-s
Isa[RM•.s
pYdlip
H111319
pXNil
Rf[[6iFli[511HG
u1MAl6 a
U ul[P[Vu4m.-.R[
EpieNv�ma�nxlm. j mulm
AeµBvmla.�a6 Pm>4V x+ml
AYF{M[iblc
6KEP'4Wu1lEraignRm�.TaRhnenk, 001, W., r*,w «lmwedd�rM1 Ina w.Iem i1 It
nmr-EpraEl•a. u{vYM wwwawNNNaf nom. otPup'ron PgnMr'PnI Nrvxi9 Frvin4 bMaw'" Pn •.1T waNaf waplNe vomer MT mnI«n
2 1 GENERATOR DETAIL
1 1 GENERATOR DETAIL
so A„ !6a
m'.
DRAWN� ISSUED FOR
a'el
--wNAYn
fra[�b'mM
GENERAC- INDUSTRIAL
RRIIIIIIIII
S0050
xsa
�u
operaling data (60Hz(
POWRR PAllx65 (N W]
,E�x�,EA-4
nwN
. Ps
¢n
Sifx Y
5yl
an�v law ccnrpE
In fl '1011d]pM1@O BpI
lu NxwF M>tpE
R.lPIIUI
In[w PA•sp 3ifi.4]]YC p4dpl
UARPIN 0 CAPARILRIB1z"Al
3X'IA ai'M'ap Op
t¢unr
)eWA9al
•-4-1_ cw
m =t
an
xv Pu4
3R
M
52
a •�
n N«
Ian
MGN6
<s lexul
.men PapNm&d mn
1.5'A�6[plunn
MMOUSTIPN AIR RFWIMMFNPS
su pv
mEns ilpv; aE 4eedMr
dm lmAmp la 1
RI
9nNonv
'0°
rpay.xEnawm
um<n,vnn
sMlws.ae
�1.5'na
sadanrtdnp lNVJGuIpAI
'f 1Y
Rwtlw
lNGINf
61ANOhY
«sMa
sew
rx.saorpoxnpp
�Pn ura
R`rRW axmnaevwvwnl<vaovnu•mamNNr<o.allov. Rlme uuvs vEappvPw*vinw:wroTwva
nallernulvwreT]wwsmv.snamNluww
Im•MVIKis Mmlpmm[artrmilwmm.«.nNoa6Ec. PRSIN.emsanxnomm Nwmnfi
1 1 GENERATOR DETAIL
so A„ !6a
m'.
DRAWN� ISSUED FOR
M
mx�tlmlaf�M
nIn OMINIw FdmNAYTaK
npPMrs�ne...,rm-emrerRmr
a'el
--wNAYn
fra[�b'mM
at NVa el
sml
xsa
�u
lu=wl
,E�x�,EA-4
nwN
. Ps
¢n
mx�tlmlaf�M
nIn OMINIw FdmNAYTaK
npPMrs�ne...,rm-emrerRmr
a'el
--wNAYn
fra[�b'mM
at NVa el
V. AT
P6.Y1
AarY+wl
m
rtf-I
lu=wl
T ISI®bye
kb NE HCW DAY ST
FOFTLOND, OF BI2A2
CROWN
1606 W tSiW(E AVE N, 90RE MO
SEATTLE, WA W1
INFINIGYB
FROM ZERO TO INFINIGY
N1R wNAIRK w «xlKs
DELLEVIIE, WA �
T -MOBILE SITE:
P008115A
MT VERNON
CROWN CASTLE SITE:
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
FOR REFERENCE ONLY
EST.P.E.
GENERATOR
DETAILS
,E�x�,EA-4
AE.1xP
T Mobile
kb NE HCW DAY ST
FOFTLOND, OF OI
GENERAC- O EXJETRIAL
GENERAC I R'IDIa/TAFAL
30050
standard elealures and oplions
SU050
dimensions, weights and sound levels
—
CROWN
v CASTLE
RNER0.TYP5ET
r.
iu,-�-
WMROLSY9EM
..��..
0
1505WESTV(EAVEN,SDREMO
SEATTLE, WAMIW
�P•'piYlnilR
Illad
aDNrC/NGa. rtIPMI-DUY.�NINrpry'
V•ARRI
qj
INFINIGY8
aemo<b.NRNm
as
01-Ger snese"b
aTAwNmermrelax�nx.oernx.nnwrs.INq
w
FROM ZERO TO INFINIGY
/sews w+e �ErclweNoerY
()/Iuioln F.arpmTJ•¢eom
tp
a9meID.rllYr]n[woRr mnno P[c
0As's,
fN
SW
the solWlons are endless
FN61N!]Y SIIM
gmL
/a Nh wla.P:e7
�spwrslnr..vl.'e.lonerrN.rew.0a
/FmbJ E:luee vle.ee enelMeesen�
/fR.nlYM1 rµ en,.•:bR..n.eri.a.�.ri.
a
rd
ne
aJ
a A. mergwn
a ruesrswri soP.
al.rlryYMmiiv[Rm. re LskN
ax-mMRun[mPNFN
♦M..."D.�rMllr�
ae,r«.,r
aR.l�wwVp,.e
auRR.,<[.a.w
Is%I nt,e
•cPp..n.mP.r.M.
ar.e,mur
m
Ae
as
es
W
Ru
-
- !
—
H TI
'H
0
0
p
9
1,el.,
xouac
i
u
H
- -
BELLEVUL, WA 9N1p4
T -MOBILE SITE:
P008115A
MT VERNON
CROWN CASTLE SITE:
879541
MT. VERNON
!R- iWi.i Sy—tea
ama u.InnYaGan
/ra.w lmlurcrM
/u[ve r,iNT.,.,v,MMa��PM.
sa
amew aM.o
oR.
w
2205 AVE
RSONOR
/Lmlda•RwhN.Yrvu¢rrIM A6m
fly r�
fW
aPmwnw
01--.,
a omen—.w PllamTlNemlba
• ruawrauP.eea-
OM+SPndF'e..yr
�bmhomuu 6mermr4nw
a +�ec.mem[owr•w,
WONPor0.ativY,l ErrcuiullnVwrkre
3M
qs
se_
r
SW
—'
"
o
0
Q
!M[YC
VRnRN w•Pm*' ta
riwe dvl w F wr aP.'
_ _ _ _
- -
EUGENE, 97 41
EUGENE, U TY
LANE COUNTY
150'-0"MONOPOLE
■.>o. ....a�[1¢R..a ase,mm
r`�RIRRcmau'
/enlJ..,.lo.erssal
a
aunm.w.n..:Msr'sa-:
a rdar.PuiulwnlnuM
aMKMlmewalmxn
_
a
o
�
DMWNGS ISSUED FOR
/:
L�nenrarmr, +a•�
/wma—flknnl M1aes
/r.rti.y+nrHlUd Ral.lu.
It
se
Ilo
na
nd
aEsvml+ladmugmm,ryRel
OR.,oae R-NaP bees nl®n+rxaame mwn0
QReedenirep lkd MerFrm.]Np,. wrAe,msenl
!)M.m..n-LvP N'd MurM1w�ITpesl.,n Na'..1
iron Lw Lwrt*n Nr RmRr••RNRR
-
-
atl
L
�
W
--..wIMR-v
a..�Mi.-., e,..,e.¢,n.,---•
—A
/we.a. arv,.mR�ernr,Emu
•
rva
�wrNaeor.Mme.rrmr-wnEx
NeA.
w..e mrrr
/npt-r,s •..Irmr..
sse
•'aan
Irls,
/F lms
rsw Lm+
a.uNaen nNa•
/yplMdns�
/saap-rve.d
"eN..
ne
nRd
aewn.
�.
s—1e1-1
onO..INr
FeRoN
/o,ucr
sw
*w
as .rc[Prcememmenr.PrN,...rv.eeeN.l
YNR WRORV REDOGNUID 1011 INDISTRIAL DWlR
aC empenE.erPw�P'VrvrmeJ'Nl nfrnP%�^an
uTNLrwTORsrsTFM
i(l
a EW enll�IReegrmnmllwlertl]hrteoml
•E�er:
l"'.
Snl
Nd
-
FOR REFERENCE ONLY
/vr
emmefawsnP..—)xal
11
a KQLI., MP'WIrnNMgiM FNdrxrl
4ueq uW,yn
vul
41NiWeMl11R net Rieder
]Ie
PM9grw
e.eb iu
ppe.ue.ensumrraV aa'uu.hrm¢.e'aW
wb Trs.MOme•.Pne.oa.re.a M1r Aeriwene6wrswe remheq
0
canarN VYNY 6rsa:Rra, nc•616 W.l929tlHN'[., waurcesra, N7 58169 • IxReracam
"'•"".
ewxw.e>,..Nw.si.. Rnmre�Ny«ma..lannemx.ma.Nr Nrronu�vrP-Nmeruv harm
GENERATOR
DETAILS
-ff.
pE-4.1
A
1-
2 GENERATOR DETAIL
E
1
GENERATOR DETAIL
a I 7 I 6 1 5 1� 4 I 3
C w awt.
aaw xvr ,.a �.w
A I
u
a
_ L
f
,MA A♦mF i a°.iN,
7
6 1 5
A.Ie
�mIi do
et alj
wv a°wx y� r�rxP
T Mobfle
k NII
FORT MD,OngI ®�
CROWN
p v CASTLE
1505WESTV EAVEN,SDREMO
SEATTLE, WI
INFINIGYB
FROM ZERO TO INFINIGY
M» wFAI°rrsw wWess
BELLEVNE, WA S
C
mm
�44E°1Jillt[W6!! SE
F� ISIE Flp AcNiII
x ees mase is � sea m n� idW:�rw cosmic
�
asv sue
Pi�4
A
1 Ali
l M° !li PTIIBi MO SIXI@5
.r,.n eu a:6111E.
.�.nuwF..ni
e iw euIN N u.e
° m u cercPm o sAn
u rxn wersno°
N w5n m �r.wrm eiw
isi
i�Ai°firltt'R IG mWiW. WiVN
i.
Irl
i
'
r
1
7
6 1 5
A.Ie
�mIi do
et alj
wv a°wx y� r�rxP
T Mobfle
k NII
FORT MD,OngI ®�
CROWN
p v CASTLE
1505WESTV EAVEN,SDREMO
SEATTLE, WI
INFINIGYB
FROM ZERO TO INFINIGY
M» wFAI°rrsw wWess
BELLEVNE, WA S
C
5
1 I TANK DETAIL H
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
mm
�44E°1Jillt[W6!! SE
F� ISIE Flp AcNiII
x ees mase is � sea m n� idW:�rw cosmic
�
asv sue
Pi�4
A
1 Ali
l M° !li PTIIBi MO SIXI@5
.r,.n eu a:6111E.
.�.nuwF..ni
e iw euIN N u.e
° m u cercPm o sAn
u rxn wersno°
N w5n m �r.wrm eiw
i�Ai°firltt'R IG mWiW. WiVN
5
1 I TANK DETAIL H
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
°ILLS Yea
Sm
�44E°1Jillt[W6!! SE
F� ISIE Flp AcNiII
A
.r,.n eu a:6111E.
5
1 I TANK DETAIL H
T -MOBILE SITE'
P008115A
MTVERNON
CROWN CASTLE SITE'
879541
MT. VERNON
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
150'-0" MONOPOLE
FOR REFERENCE ONLY
SENEsr.srE. TANK
DETAIL
SIR I
DRAWNIGS ISSUED FOR
FOR REFERENCE ONLY
SENEsr.srE. TANK
DETAIL
SIR I
1ID.04,arm I �I
41 t 002
3 1 NOT USEDSRI
GTE
Rated
Armies
%Asha a
EDLleaure EmGleeeres
Herphl WIdM
Wennwrd
Bell pemera
Endream am
b,M
T Mobile
It W
001
w
ADD NE HIXIAMY ST
I 09
TW
AI
OLX 3X
1X
FORTLOND, OR 9I
U2,1
t0
(iENERAC' Iwousrwln�
150.200
120l24D
36 31
1X
3].5
GTS Control Systems
t0
CROWN
v CASTLE
114L 0
120130X
36 3a
1X
37.5
59,1
Uwa, XD19[p LOGIC CONTROL w r Inost" MJIa5OG
185
1GP290
15(E5WESTV EAVEN,SIIREMO
SEATTLE, WA W 1 W
i6• 1a'
M
19.5
-._...,-.._....-- .- __.. _. _, 75 � 001
12
205
15D2W
Wp
i6• a0”
M
Cl6m...._...-,.._„"'--,. _._....._....___................................_..,...,-_.....
PlFILKLI
5Lup
14.6
12
205
I N F I N I G Y8
120!240
59 4d
1B
T -law.
ulllmrllq. _.._ ..... .... c1_1a5ee. IWi,
Ffgrm NXnlmulmuftn Wm ___ _._.. - __ SE
19T
10
245
3p04W
120Y1OX
ameunume wit
.... ._... ...... _....59T30 M'n G+lll
16
37.5
12.7
10
245
3110.-100
NIImonlVflmmm
AepINnklEW...., ........ .-.... _....-...- 1.50MIL 4Wa I
5Dpue CWILMn_. _.___ .._._ __.__-1-00Mn. Cw4I1
19• .'19'
M
FROM ZERO TO INFINIGY
FI
12
3TS
fl....._ ....... .... ........ ........... ... _......... ._._...._._..._..._._..._....... ._._........_._85-95%L$4)
1600
MX' Op
the solutions are endless
49.5
Toe
12
FmMuer
rinsEby Buqu .... ....... ... .... ..._.._....,..._...... _,....,..--._...,.,..,,,-.....,.,- -......._._10Ste
1._ Ni.1
Terror
Iil1e Delay Neural...,.,,..,_..........................._......,...,-......_,........_._.....,,_....._,.-_........ []-1D Svc. Udl1
LtE+''.ise.............................................................................�...�.............Orv'Of15MEn
9EaEvue, LOA BeaOa
Alirru+an
l'JlalmP ❑'iME BYIGses..._...._._..._.._._.._.•._..._._._._.—._.__._..._......__._.-...........Ory9XEX9CP
T -MOBILE SITE:
P008115A
r ode xe0l,le w.....
0 y fmfl _.._......._... an'9HSedch
BIMd+IUW..... .,..,..�.......��..�.................. . , ......-.
Withstand CNrrent-100
4dl GTS Series
MT VERNON
CROWN CASTLE SITE:
GTS Rend Ampl 100 15D 209 200 AIDE
FWE PRO-:CTED
IWaemum IMS Bemmdri®I
Been Comm -Amp 4003,000 MM 200,0100 800,000 300.0.0
879541
MT. VERNON
Munk Sae
312t Amp, 2W 40D 900 X01 MR
Fuse Clew J.1 JT J.T J.T A
2205 HENDERSON AVE
EUGENE, OR 97441
LANE COUNTY
GF6COR mIMSS PndrIcal nISm. sepmLBrheH Im eMGXIGGIrwIXrl6perPX
MeaXn IMM symmelrlwl
O
Faun COTem-AMP Ia,OdJ 25W0 43.w10 3;.OW 33.4100
Pmled'm4 oeel0e eonl nexus
159
RXdry I'X6al-Amp• SDA 200 69] 0310
150'-O" MONOPOLE
. 10000 Fartnimn nMllS •n,NA.J y6 pyY,prcGlrwrcrbnl li IR6NME, CFE 64KaAa
• [VPmI le1rcR A irtn _ aflp'ynC
DRAMMINGES BI FOR
w D, Onll Dimensions
1ID.04,arm I �I
41 t 002
3 1 NOT USEDSRI
GTE
Rated
Armies
%Asha a
EDLleaure EmGleeeres
Herphl WIdM
Wennwrd
Bell pemera
Endream am
b,M
IVe1gP[
Meet
It W
001
w
In
I 09
TW
AI
OLX 3X
1X
3].5
U2,1
t0
1X0
150.200
120l24D
36 31
1X
3].5
09.1
t0
1X5
114L 0
120130X
36 3a
1X
37.5
59,1
10
185
1GP290
27]1480
i6• 1a'
M
19.5
11
12
205
15D2W
Wp
i6• a0”
M
495
14.6
12
205
311p-Ipp
120!240
59 4d
1B
37.5
19T
10
245
3p04W
120Y1OX
36 2a
16
37.5
12.7
10
245
3110.-100
TRr490
19• .'19'
M
0.9.5
FI
12
3TS
300-100
1600
MX' Op
2d
49.5
Toe
12
325
cnnEUA mw.eu wlnmwo•van earwo ma eea•wrcxms 9e we e. "Iarxmm n.vn.
EWIPIAMTCABINEf 3R'0HILTI KWIKBOLTM
STANLESS STEEL WEDGE Terminal Lag Wire Ranges
LWItwASHER
FIATWA9IER
^'^"_'S'E""'•'^"•.
EFFECTNE II MEM(N'
WMINAL EMBEDMMTI(ICC
R.
RARE NAAN 3ENDRITLAN
Borl,[IDX IFFMXusil Lu4FFe-
NMNXENS41
MCIII'U1HM' aXOlXpws .1 RAIVLTim
Y W WB 00 6 W4UG IIMXL
740 P1 �'T�
/^ Vri
1
_ r
I
__ A. I-STRUCTRININ
AM
3/t3/]3
150
49'J11CN-4ANG
4 05If�fX-PANV 351MCM-6ANa
R06
LWItwASHER
FIATWA9IER
^'^"_'S'E""'•'^"•.
EFFECTNE II MEM(N'
WMINAL EMBEDMMTI(ICC
1$$MTpI
ApX
Borl,[IDX IFFMXusil Lu4FFe-
NMNXENS41
MCIII'U1HM' aXOlXpws .1 RAIVLTim
Y W WB 00 6 W4UG IIMXL
740 P1 �'T�
/^ Vri
1
_ r
-H -11 MI
CONCRETE
ESRi38G1, TO BE N STALLED
N EACH CORNER OF CABNET
3/t3/]3
150
49'J11CN-4ANG
4 05If�fX-PANV 351MCM-6ANa
R06
<p361[W IPWO
< 350NCrs E -AS y$IMgN X4Hy
61ABPEF IAN
(4TOTAL)WITI MNIMUM5"
O�EG�,pO
G� •y
3BA
ED3MN-EAWG
tl MAUNA-dAW3 351NCM-X ATN
EDGE DISTANCE
Er, -25aMte-Im AWC
SAMEA 1. SAI ASINLAI-a PM'.
ON' Q
�S 'g1,jaal'N
�Q.
�p7tEhJ
-00
MAND
4 GROWN-4AW0 A>r
.1-I
"Naem-X
V11-[250MCM-1:00 AW61
Eamc1-1r,0"M]'•
w-NS hJutlG6 i�ATS Mitis imancuVal. '•NaXahNMilc ripus LeMS IISIR2.1. 11.1
LL EVIRATXeN DATI 06/30/24
EM EM
Es
3 4 e' RVAm Sy6lemsX •SdY 4RAASn2W iNY 5ati lMukesAAe'NAMWI 31 n9 paeral..mm E * E
ATS DETAIL AND
ANCHOR DETAIL
E�.�eEA-6 AE.1�
2 ANCHOR DETAIL UE 1 AUTOMATIC TRANSFER SWITCH DETAIL PEE
TRIS L-AMENTAINTHE IDEAS AND DESIGNS N-CRATEDNEREN AS AN INERNAMENT CR PROFESSIONAL SEFRLE ARE THE PROPERTY GF NFINLY ENGISERING - AND ARE N -RE RSED IN MR- GR IN - � CRNER PRCJE W11- THE WRITREN ARNICRISDARION CIF INSINICY ENGINEERING PUI T IS An- NOR My PERSKI TDAMEND My ASPECRI ff THERE DFRENINGS W11- THE WRITREN APPRCAAL CIFTHE PIRSARESSIONAL CIF RE-
TIE INTO
NOTE
GROUNDGRWND TO
EXISTING
FENCE POST
"SA FROM ANTENNA GRWND BARS AT BOTTOM OF
�(RIRING�r
T -
I I
GROUNDING SYMBOLS
CABLE GROUNDKIT� TOWERSRBAR8AOLESSHMO
ONLY USE EXOTHERMIC WELDB,
o■yR'/'■'gyp ei■9y
— GRWND BAR
; �:;:
\IIs
i
GROUND ROD WITH ACCESS
®
GROUND BAR ON
kb BE HOUAMY ST
FORTLOND, OR BI2A2
WALL, ICE BRIDGE,
e CH EMICAL GROUND ROD
CLWCRETE,ORON
ANTENNA TOWER
® GROUND ROD
CROWN
CADWELDTYPECONNECTKIN
O O OO O O O
C
v�SUTLG
• COMPRESSION TYPE CONNECTION
O O OOO O O O O O
1505 W ESTVHE AVE N, SURE MO
GRWNDNG WIRE
O O
SEATTLE, WA SS1W
TYPICAL: NAWG FROM EQUIPMENT TO GROUND BAR; M
RING, FROM METER TO
GROUND RING, GROUND RIG
GROUND RING, AND FOR GRW ND
FOR
-TWO HOLE -UG, OR EXOTHERMIC WELD TO BE
G, EX
I N FI N I GY8
OR
THERMIC NGSERVICE
USED WITH Y3
GRWN D OR GROUND RING
FROM ZERO TO INFINIGY
GROUNDOOMIDUCTORSHALLBEELININATED
PPw ipyPlOns w �nd.ss
WHEN GROUND BAR IS ELECTRICALLY BONDED
TO METAL TOWERAMONNIPOLE STRUCTURE
BELLEVUE, WA �
6
NOT USED
E
5
GROUND WIRE INSTALLATION
T -MOBILE SITE'
1.) COPPER GROUND BAR, IN'S I'S M", NEWTON INSTRUMENT CO.
P0081155A
CAT NO B6142 OR APPROVED EQUAL. HOLE CENTERS TO MATCH
MT VERNON
NEMA DOUBLE LUG CONFIW RATION. (ACTUAL GROUND RAR s12E
WILL VARY BASED ON NUMBER OFGRWND CONNECTIONS)
TIE INTO
EXISTING
GROUNDGRWND TO
EXISTING
FENCE POST
�(RIRING�r
T -
I I
mmmm
• ,.
��'P
; �:;:
\IIs
2.) 5/5' LOCK WASHERS, NEWTON INSTRUMENT CO. CROWN CASTLE SITE:
CAT. N0. 301" OR APPROVED EQUAL
3.) WALL MOUNTING BRACKET, NEWTON INSTRUMENT GO 8795541
CATNOI A-6056 OR APPROVED EQUAL MT. VERNON
J) 8611 X1" HAGS BOLTS, NEWTON INSTRUMENT GO
CAT NOI W12-1 OR APPROVED EOUAL
2205 HENDERSON AVE
3 EUGENE, OR 97441
LANE COUNTY
0
° 150'-0" MONOPOLE
/0 00 0 °
2 ®° 0 ° �0 0 1
0 °
0 DRUMVINGS ISSUED FOR
Y- DISCRIPTSIN
NOTES:
GROUND BAR AT ANTENNA LEVEL TO BE BONDED DIRECTLY TO TOWER
-�y I I STRUCTURE W INSULATORS USED. GRWNDRARATBASEOFTOWER
I` I
GTR UCTURETO BEATTACHED WTM INSUTATORS. CONNECTIONTO TOWER
STRUCTURESHALL BE PER MANUFACTURERS RECOMMENDATIONS.
I � I •• I
4 1 EXOTHERMIC CONNECTIONS 3 1 TYPICAL GROUND BAR
I l
i` 4DC
D 1"SCHSOOR
U ID TKWT(A.)
W R LOADED W/
iCUJBASTINGTO TS AIA RM CA BLEQq
% A
FENCE POST OBILE 7 q
_-- i
EQUIPMENT
IPMEM CARNET
]/D/43
n2
y
OR 1
— 1— ----------
% �r I PROcoseo GRW ND 9�°� `R,3 �QQ
BARIGRWN DING FOR PI -H----GENERATOR; TIE INTOGENERATORWN INTO -- �y��J — TIGMG) CONDUIT OA L TIRATIOH UA . 08/JO 9
(COTRACTO TO VERIF J TIGHT ED
(CONTRACTOR TO VERIFY) W CA TELCOFLEX CABLE
MONNECTIONGRWNDEXOTHEE*TIILE.
CONNECTION
RMIO GRW ND GENERATOR
To SCHEMATIC GROUNDING
CUTTING R U GENERATOR GRW ND
EXISTING GROUND RING GENERATOR PLAN &DETAILS
�.�,ER 1 I
2 EQUIPMENT GROUNDING PLAN ,, _,„ ®. 1 GENERATOR SCHEMATIC PLUMBING PLAN