Loading...
HomeMy WebLinkAbout2021 10 05 AIS DU Horace St Apartments AGENDA ITEM SUMMARY Meeting Date: 10/5/2021 Meeting Type: Regular Meeting Staff Contact/Dept.: Melissa Cariño, DPW Staff Phone No: 541.744.4068 Estimated Time: 10 minutes S P R I N G F I E L D PLANNING COMMISSION Council Goals: Promote and Enhance our Hometown Feel while Focusing on Livability and Environmental Quality ITEM TITLE: DISCRETIONARY USE APPLICATION FOR MULTI-UNIT RESIDENTIAL DEVELOPMENTS LOCATED ON TWO ADJACENT SITES ON HORACE STREET IDENTIFIED AS ASSESSOR’S MAP 18-02-05-23, TAX LOT 202 AND TAX LOT 204. ACTION REQUESTED: Conduct a public hearing and deliberations. Commission can approve, approve with conditions, or deny a request for a Type III Discretionary Use approval of a proposed alternative roof form using the Discretionary Use criteria listed in Springfield Development Code (SDC) 5.9-120 and the Multi-unit Design Standards – Alternative Design Discretionary Criteria listed in SDC 3.2-245. ISSUE STATEMENT: The applicant has requested a review under the Multi-unit Design Standards – Alternative Design Discretionary criteria (SDC 3.2-245) for two adjacent multi-unit residential developments on Horace Street. The applicant seeks approval for an alternative roof form for the proposed three residential buildings on the subject sites. ATTACHMENTS: Attachment 1: PC Order –811-21-000196-TYP3 Exhibit A: Vicinity Map for Subject Sites Exhibit B: Staff Report and Findings Attachment 2: Applicant Submittal Exhibit A: Proposed Building Elevations Exhibit B: Site 1: Site Plan, Tax Lot 202 – 811-21-000141-TYP2 Exhibit C: Site 2: Site Plan, Tax Lot 204 – 811-21-000226-TYP2 DISCUSSION/ FINANCIAL IMPACT: The applicant plans to develop two multi-unit residential projects located next to each other on Horace Street and across from Mt. Vernon Elementary School. Both projects are currently in the Site Plan Review process. Because the proposed roof form on the buildings does not meet the Multi-unit Design Standards (SDC 3.2- 240), the applicant submitted a Discretionary Use application utilizing the Multi- unit Design Standards – Alternative Design Discretionary Criteria listed in SDC 3.2-245), specifically under Building Form. The Type III Discretionary Use review process is running concurrently with the Site Plan Review and Tree Felling Permit applications for the adjacent multi-unit residential developments, but the Planning Commission is only making a decision on the Building Form, and in particular the roof design. The Planning Commission may: • Approve the application; • Modify the findings and/or add conditions of approval; or • Deny the application based on the Commissions’ findings in response to criteria in SDC 3.2-245 (Multi-unit Design Standards – Alternative Design Discretionary Criteria). The Planning Commission’s decision is final unless appealed to the Springfield City Council as provided in SDC 5.3-120. BEFORE THE PLANNING COMMISSION OF SPRINGFIELD, OREGON FINAL ORDER FOR: DISCRETIONARY USE APPLICATION FOR MULTI-UNIT RESIDENTIAL DEVELOPMENTS LOCATED ON TWO ADJACENT SITES ON HORACE STREET IDENTIFIED AS ASSESSOR’S MAP 18-02-05-23, TAX LOTS 202 AND 204. ] ] 811-21-000196-TYP3 ] ] NATURE OF THE APPLICATION Discretionary Use and Multi-unit Design Standards – Alternative Design Discretionary Criteria Approval for the use of the shed roof form on the three buildings for multi-unit residential developments located on two sites on Horace Street, across from Mt. Vernon Elementary School. The two adjacent lots are identified as Assessor’s Map 18-02-05-23, Tax Lot 202 and Tax Lot 204. The subject properties are shown in the Vicinity Map for the subject sites, which is Exhibit A to this Order. Timely and sufficient notice of the public hearing has been provided, pursuant to SDC 5.2-115. On October 5, 2021, the Springfield Planning Commission held a public hearing and conducted deliberations on the Discretionary Use application. The staff report, written comments, and any testimony of those who spoke at the public hearing were entered into the record. CONCLUSION On the basis of this record, the Discretionary Use is consistent with the the Multi-Unit Design Standards – Alternative Design Discretionary Criteria of SDC 3.2-245. This general finding is supported by the specific findings of fact and conclusion in the Staff Report and Findings, attached hereto as Exhibit B. ORDER/RECOMMENDATION It is ORDERED by the Springfield Planning Commission that Case Number 811-21-000196-TYP3, Discretionary Use Application, be approved as conditioned in Exhibit B. This ORDER was presented to and approved by the Planning Commission on October 5, 2021. ____________________________ ____________________ Planning Commission Chairperson Date ATTEST AYES: NOES: ABSENT: ABSTAIN: Attachment 1, Page 1 of 6 VICINITY MAP 811-21-000196-TYP3 Discretionary Use Site 1: 18-02-05-23, TL 202 Site 2: 18-02-05-23, TL 204 Bruce Wiechert Custom Homes, Inc. SITE 1 SITE 2 EXHIBIT A, Page 1 of 1 Attachment 1, Page 2 of 6 Staff Report and Findings Planning Commission Discretionary Review Request: Multi-unit Design Standards – Alternative Design Discretionary Criteria Horace Street Apartments Hearing Date: October 5, 2021 Case Number: 811-21-000196-TYP3 Applicant: Bruce Wiechert Custom Homes, Inc. Property Owner: Bruce Wiechert Custom Homes, Inc. Sites: Two adjacent properties located on the south side of Horace Street, east of Filbert Lane, and across from Mt. Vernon Elementary School. The two sites are both zoned Medium Density Residential and are identified as Assessor’s Map 18-02-05-23, Tax Lot 202 (Site 1: 0.31-acre western site) and Tax Lot 204 (Site 2: 0.74-acre eastern site). Both sites are currently vacant. _________________________________________________________________________________________________ REQUEST The Planning Commission is asked to conduct a public hearing and deliberations, and approve, approve with conditions, or deny a request for Discretionary Use Approval of a proposed alternative roof form under the Multi- unit Design Standards – Alternative Design Discretionary Criteria listed in SDC 3.2-245. SITE INFORMATION/BACKGROUND The applicant plans to develop two multi-unit residential developments located next to each other on separate Horace Street sites, across from Mt. Vernon Elementary School. Both projects are currently in the Site Plan Review process. Because one of the proposed roof forms on the buildings does not meet the Multi-unit Design Standards (SDC 3.2-240), specifically the Building Form design standard, the applicant submitted a Discretionary Use application to utilize an alternative shed roof form on the residential buildings. The applicant proposes to develop an 8-unit residential building on Site 1 (Tax Lot 202) and 20 units in two residential buildings on Site 2 (Tax Lot 204). On Site 2, there will be a 12-unit residential building along with another 8-unit residential building for a total of 20 dwelling units. Site 1 has received Tentative Site Plan approval (811-21-000141-TYP2). A Tentative Site Plan review application has been received for Site 2 (811-21-000226- TYP2), but no decision has yet been issued. The Tentative Site Plan approval for Site 1 includes a condition of approval requiring the applicant to change the proposed roofs of the residential buildings to one that meets the Multi-unit Design Standards in accordance with SDC 3.2-240 or to obtain Discretionary Use approval for the proposed shed roof form as shown in the submitted building elevations. The Tentative Site Plan decision for Site 2 will reflect the outcome of the Planning Commission’s decision on this Discretionary Use application. The Planning Commission can approve, modify findings/conditions, or deny the application. The Planning Commission’s decision is final unless appealed to the Springfield City Council as provided in SDC 5.3-120. Notification and Written Comments Notification of the October 5, 2021 Planning Commission public hearing was sent to all property owners and residents within 300 feet of the outer boundary of the subject site on September 3, 2021. Notification was also published in the September 26, 2021 edition of The Register Guard. Staff posted notices on the subject sites, the City’s website, and the Digital Displays located in City Hall. Staff did not receive any comments regarding this application as of the date of this report. EXHIBIT B, Page 1 of 4 Attachment 1, Page 3 of 6 * * * On April 16, 2020, the Governor issued Executive Order 20-16, which requires governing bodies to hold public meetings and hearings by telephone, video, or through other electronic or virtual means whenever possible. On June 30, 2020, Oregon Legislature enacted House Bill 4212 (HB 4212), which waives requirements under the Oregon Public Meetings Law and other statutes to facilitate public meetings online or by phone. Under HB 4212, the governing body must make available a method by which the public can listen to or virtually attend the public meeting or hearing at the time it occurs. House Bill 4212 allows governing bodies to accept public testimony by telephone or video conferencing technology, or to provide a means to submit written testimony (including email or other electronic methods) that the governing body can consider in a timely manner. House Bill 4212 overrides conflicting requirements for quasi-judicial public hearings in state law or in the Springfield Development Code or Metro Plan. The October 5th public hearing is being conducted via online meeting platform that allows members of the public to listen to the meeting online or by calling a toll-free number. Members of the public may provide testimony to the Planning Commission by joining the online meeting remotely. Details regarding how to join the online meeting were provided in the Planning Commission meeting agenda and posted on the SpringfieldOregonSpeaks online platform1. Criteria of Approval Per SDC 5.9-120D.2, the Planning Commission may approve a discretionary use for alternative design standards for multi-unit development if the proposal conforms the Multi-unit Design Standards – Alternative Design Discretionary Criteria in SDC 3.2-245. CRITERIA OF DISCRETIONARY USE APPROVAL SDC 3.2-245 contains the Multi-unit Design Standards – Alternative Design Discretionary Criteria that are applicable to this application. Finding 1: SDC 3.2-240 contains the Multi-unit Design Standards and SDC 3.2-245 contains the Alternative Design Discretionary Criteria. The applicant is requesting discretionary use approval only for a “shed” roof form. The “shed” roof form does not meet the standard in SDC 3.2-240.D.2.b that requires that “roofs shall have gable, hip, or gambrel forms, (minimum pitch 3 to 12) with at least a 6-inch overhang”. The applicable discretionary criterion to allow an alternative roof form is provided in SDC 3.2-245.C. C. Building Form. The Planning Commission shall find that the proposed design promotes building forms that contribute positively to a sense of neighborhood and to the overall streetscape. This criterion may be met by complying with the Section 3.2-240D.2., Section 3.2-250 or by considering the following guidelines: 1. Design exterior building elevations to avoid large expanses of uninterrupted buildings. Finding 2: The proposed exterior two-story building elevations show that the height of each building is ~27’ high. The 8-unit buildings have the approximate dimensions of 38’ wide by 100’ long with a total square footage of 7,600 sq. ft. of living space. The 12-unit building have the approximate dimensions of being 38’ wide by 150’ long with an area of 11,400 sq. ft. of living space. All three buildings do not exceed the maximum 160’ long building design standard in SDC 3.2-240D.2.a. Finding 3: All three proposed buildings do not have any large expanses of uninterrupted building surfaces as required in the Multi-unit Design Standards (SDC 3.2-240.D) with human-scaled architectural elements including window and door, roof offsets, approximately 8-foot-high walls, porches, balconies, and projections. The largest uninterrupted building surface is approximately 20’ and can be seen on the left elevation for the 8-unit buildings and the right elevation for the 12-unit building. This does not exceed the requirement in SDC 3.2-240D.2.e where architectural features shall occur at a minimum of every 30’. 1 SpringfieldOregonSpeaks can be accessed at https://springfieldoregonspeaks.org EXHIBIT B, Page 2 of 4 Attachment 1, Page 4 of 6 2. Depict building scale consistent with nearby buildings; “scale” relates to the size of various features (including, but not limited to entries, roof surfaces, façades, windows and materials) as compared to those features on nearby buildings. Finding 4: The proposed multi-unit residential building scale is consistent with nearby single-family residential buildings to the south and west with similar human scale-sized wall heights and entries at 7’9” high, ~ 4’x2’ vertical windows, and ~4’ x 3’ horizontal windows. While there are no shed roof forms used on nearby buildings, most of the buildings in the vicinity have either a gable or hip roof form. The proposed multi-unit residential buildings have both gable and shed roof forms; therefore, the gable roofs are consistent with buildings in the neighborhood. 3. Provide transitions to nearby buildings by massing; “mass” relates to the overall size or bulk of a building or its principal parts. Finding 5: The proposed site plans for both subject properties provide transition/buffer areas and required setbacks to nearby buildings. For instance, there is a 20’ setback between the 8-unit building on Tax Lot 202 and the 12-unit building on Tax Lot 204. The two buildings proposed for Tax Lot 204 have the parking area between them, providing considerable space (more than 40’) between the buildings. Finding 6: The applicant also provides buffer and transition areas between the proposed buildings and other existing buildings abutting the subject sites. For instance, the proposal provides for more than 40’ between the 8-unit building on Tax Lot 204 and the property line for the parcel to the east. Likewise, there is ~40’ (parking lot) between the 8- unit building on Tax Lot 202 and the property line for the parcel to the west. On Tax Lot 202, the site plan provides more than 40’ of landscaping and stormwater management facilities between the residential building and the property line of the parcel to the south. On Tax Lot 204, the site plan provides more than 45’ of landscaping and stormwater management from both buildings to the property lines of the parcels to the south of the site. Lastly, the large buildings located at Mt. Vernon Elementary school are located on the other side of the Horace Street public right-of-way. 4. Provide porches, bays, and balconies that compliment nearby buildings. Finding 7: While nearby buildings do not provide the same land use (single-family residential, public school) as the multi-unit residential proposal, all three residential buildings for the subject sites provide porches and balconies for each dwelling unit that complement each other. 5. Provide roof variations through offsets, breaks and/or extensions. Finding 8: The proposed 2-story buildings have both gable and shed roofs that have a 4 to 12 pitch, which meets the minimum 3 to 12 pitch in SDC 4.2-240D.2.b. keeping the design at a residential scale, which is consistent with other nearby residential buildings to the west and south of the subject sites. Finding 7: While the building design is residential in character, the adjustment to roof design standards also provides a dynamic, modern appearance than strict conformance to gable, gambrel, and hip roofs. Again, the shed roof is the only Building Form design standard the applicant is request an adjustment for in this application. 6. Provide transition between the multi-unit site and LDR areas. Finding 8: There are no Low Density Residential (LDR) zoned areas adjacent to the subject properties; however most, if not all, of the surrounding residential properties consist of a single-family home which mimics LDR zoned areas. The applicant provides the required buffer and transition areas between the proposed buildings and the other adjacent residential properties. EXHIBIT B, Page 3 of 4 Attachment 1, Page 5 of 6 7. Enhance solar access protection and/or energy conservation. Finding 9: While the applicant does not provide any specific details on energy conservation or enhancement of solar access protection with the proposed shed roof form, the pitch of the proposed shed roofs is the same as the proposed gable roof (4 to 12). Based on the roof pitch and building layout shown on the site plans, the applicant’s proposal does not negatively impact solar access to surrounding properties or change the level of the building’s energy efficiency with their proposal to use the shed roof form. 8. Protect on-site and off-site natural and designated historic features. Finding 10: The subject sites do not have any on-site or off-site natural or designated historic features, so this guideline is not applicable to this application. 9. Provide human-scaled architectural detail. Finding 11: The wall height for both the 1st and 2nd floors of the proposed buildings is ~8’. The doors are ~7’ high and 3’ wide. The windows dimensions are provided in Finding 4 and are located at the heights that allow the residents to look outside. The architectural details provided in the submitted building elevations are human-scaled. 10. Provide visual variety in elevations, architectural details, colors, and materials, compatible with existing development; Finding 12: The submitted building elevations provide a variety in elevations and architectural details with the following: two different roof forms used; breaks and offsets of doors, windows, and roofs; and stone pillars where stairways are located. While there is no existing development on the subject sites, the proposed building elevations are compatible with existing development in the vicinity through roof types and pitch, building materials used, and building scale. Conclusion: The proposed designs promote a building form that contributes positively to the sense of neighborhood and to the overall streetscape as can be seen in the submitted Building Elevations. The proposal meets all of the Building Form guidelines in SDC 3.2-245.C. The above findings demonstrate that the proposed building form design meets these Alternative Design Discretionary Criterion guidelines. CONDITIONS OF APPROVAL SDC Section 5.9-125 allows for the Approval Authority to attach conditions of approval to a Discretionary Use review request to ensure the application fully meets the applicable criteria of approval: NO CONDITIONS OF APPROVAL RECOMMENDED CONCLUSION: Based on the above-listed criteria, City staff recommends that the Planning Commission provide approval of the proposal because they believe it meets the applicable Discretionary criteria as listed in both SDC 5.9-120 and SDC 3.2-245. EXHIBIT B, Page 4 of 4 Attachment 1, Page 6 of 6 City of Springfield Development & Public Works 225 Fifth Street Springfield, OR 97477 Discretionary Use SPRINGFIELD w 6 Required Project Information (Applicant., Applicant Name: Bruce Wechert complete this section) I Phone: 541-686-9458 Company: Bruce Wlechert Custom Homes, Inc. Fax: Address: 3073 Skyview Ln., Eugene, OR 97405 Applicant's Rep.: Anthony J. Favreau Phone: 541-683-7048 Company: The Favreau Group, LLC Fax: Address: 3750 Norwich Ave., Eugene, OR 97408 Property Owner: Same as applicant Phone: Company: Fax: Address: ASSESSOR'S MAP NO: 18-20-05-23 TAX LOT NO(S): 00202 Property Address: Size of Property: 13,619 Acres Square Feet Description of If you are filling in this form by hand, please attach your proposal description to this application. Proposal: 8 Unit Apartment complex Existing Use: Si natures: Please sign and Drint Mour name and date in the aDDroDriate Required Project Information (City Intake Staff., Associated Applications: box on the next a e. complete this section) Signs: Case No.: Date: Reviewed by: Application Fee: $ Technical Fee: $ Posta a Fee: $ TOTAL FEES: $ PROJECT NUMBER: Revised 1/1/06 Molly Markarian 1 of 4 Attachment 2, Page 1 of 10 Owner Signatures This application form Is used for both the required pre -submittal meeting and subsequent complete application submittal. Owner signatures are required at both stages in the application process. An application without the Owner's original signature will not be accepted. The undersigned acknowledges that the Information In this application is correct and accurate for scheduling of the Pre- Submittal Meeting. If the applicant is not the owner, the owner hereby grants permission for the applicant to act in his/her behalf. I/we do hereby acknowledge that I/we are legally responsible for all statutory timelines, information, requests and requirements conveyed to my representative. Date: Signature 1 represent [his application to be complete for submiRal to the City. Consistent with the completeness check performed on this application at the Pre-SubmlBal Meeting, 1 affirm the Information identified by the City as necessary for processing the application Is provided herein or the Information will not be prowCedd not otherwise contained within the submittal, and the City may begin processing the application with the Information as submitted. This statement serves as written notice pursuant to the requirements of ORS 227.178 pertaining to a complNe appllu Owner: Date: 0 2 Signature Rlwaed 10. 14. 11 Rl 2&6 Attachment 2, Page 2 of 10 HORACE APARTMENTS DISCRETIONARY USE NARRATIVE July 17, 2021 Assessor's Map: 18-02- 05-23 Tax Lot 0202 Applicants: Bruce Wiechert Custom Homes, Inc. 3073 Skyview Lane Eugene, OR 97405 541) 686-9458 Applicant's Representative: The Favreau Group 3750 Norwich Ave. Eugene, OR 97408 541-683-7048 Attn: Tony Favreau DISCRETIONARY USE REQUEST The applicant proposes to construct an 8 -unit apartment building on the subject site. A shed roof is proposed instead the roof design as stated in Springfield Code 3.2-240.D.2.b. "Roofs shall have gable, hip, or gambrel forms (minimum pitch 3 to 12) with at least a 6 -inch overhang" The Planning Commission may approve adjustments to the multifamily design per the City code below. Please see the responses below to the applicable code sections. 3.2-245 Multi -unit Design Standards—Alternative Design Discretionary Criteria A. Description. The Planning Comrnsston may approve adjustments to the multifamily design standards Listed in Section 32240 thatpredude romp/iance under section 3.2-250. In addition, the applicant may chose this Type IIIDiscretionary Lke procedure when proposing an innovative design that may prelude compliance with one or more ofthe design standards under Section 3.2-240. The multifamny design standards are: Building Orientation Building Fom i; Storage,' Transition and Compatibility Between Multi -unit and LDR Development Open Space Landscaping, Pedestrian Circulation, Parking, and Vehimiar Crculation. The Planning Commission shall And that the application complies with or exceed; the criteria for each applicable design standard Criteria for design standards not relevant to the application shall not require a finding by the Planning Commission, unless the guidelines in Subsections B through I are implemented B. Building Orientation. The Planning Commission shall 5nd that the proposed design contributes positively to the neighborhood and overall streeisrape by carefully relating building mass, frontages, entries, andyards to streets and to adjacentproperbes. This criterion may be met by complying with the Section 3.2-240D. 1., Section 3.2-250 or by considering the following guidelines: 1. Orient buildings to an interna/circulation system that mania a public street in appearance (inchiding butnot limited to sidewalks, landscaping, cross -walks, lighting, parallel perking), and does nntdimmish the appearance andsafety ofabutting primary Attachment 2, Page 3 of 10 public streets. Erarryr/es of diminished appearance'include a fence along the sidewalk that isolates pedestrians between it and the street, the location oftiash necepbdes, utlity vaults, etc. in the 'rear yard (abutting a public street); andsimilarimoacts on the streetscape. Response: The site plan complies with this section. 2 Otherdesign elements thatpm vide erceptonal design, and on balance, justify approval ofthe development with less than full compliance with the building orientation standard Examples ofsuch design elements include protection ofnaturaland cultural resources; m minizatron ofslope and tree cutting impacts; provision ofpedesbran amenities along the public street, and similarpublic benebts that elfectvely accompbsh the intentof the standard Response: The site plan complies with this section. C. Building Farah. The Flanning Commission shall bnd that bhe proposed design promotes building fours thatcontiibute positively to a sense ofneighborhood and to the overall streeiscape. This criterion may be met by complying with the Section 322400.2., Section 32- 250 or by considering the followingguidelines: 1. Design exterior building elevations to avoid large expenses ofunintemupted building surfaces. Response: The site plan complies with this section. 2 Depict building scale consistent with nearby buildings,' kale'reLates to the sim ofvarious features (including, butnotlimited to entries, roofsurfaces, fagades, windows andmaterials) as compered to those features on nearby buildings. Response: The site plan complies with this section. 3. Ftovide transitions to nearby buildings by massing "mass're/ates to the overall size or bulk ofa building or its pnnapal parts. Response: The site plan complies with this section. 4. %aide porches, bays, andbalconies thatcomp6mehtnearhy buildings. Response: The building plan complies with this section. 5. %vide mofvariations through offsets, breaks and/or extensions Response: The shed roof design provides roof variations through offsets and breaks. See attached elevation views of the proposed building. 6. %vide tiansitun between the multi-unitsite and LDR areas. Response: The site plan complies with this section. 7. Enhance solar access protection and/orencrzgy conservation. Response: The site plan complies with this section. 8. Flatect onsite and offsite natural and designated historic features Attachment 2, Page 4 of 10 Response: The site plan complies with this section. A Ho vide humanscaLdarchitectural detail Response: The site plan complies with this section. 10. Hovide visual vanety in ekvatuns, architectural details, mors, andrnateria/s, compatible wi6 existing developr nt Response: The site plan complies with this section. Attachment 2, Page 5 of 10 n j I I ' _ 1,b : i f7 -- I 7 O— i Zc A, g i n c r, I Z -- A nF ni P I 1"' yAy A S i 1 I ' \ 1 I I c I I ilY d b 1II I ' _ 1,b : i f7 -- I 7 O— i Zc A, g i n c r, I Z -- A nF ni P I 1"' yAy A S i 1 I ' \ 1 I I c o10. ilY d b G] y 1I c d i I rn I ?I V, I yrye p''. T ggqq c i jT i Iz nM e i 6 f i 6 e _` Shy q1 d{ 9 Attachment 2, Page 6 of 10 9. TTP. IX4 TRIM ON 2x8 BARGE RAFTER n / RAMP TOO FRONT PORCH OF UNIT W m TYP EXTERIOR MATE' TYP. CRICKET RIX UNITS- 2/12 ROOF F CLAW 'A' CAMP. I TYP. ARCHITECTUR TRIM - SEE TYP. W AT UPPER FLOOR: HARDI SIDING OR CANTED ROOFS OVER FRONT ENTR AT LOWER FLOOR: 5/16' X 6' HARDI HOR 5/4X 4 TRIM AT CORM WINDOW TRIM OPTION, 12 4 0 CR112 OOFF BETWEEN 12 CRICKET ROOF BETWEEN 2/12 ROOF PITCH 8 UNIT BUILDING FF,ONT ELEVATION ATTIC VENTILATION REQUIREMENTS 1/300 AT UPPER ROOF - 1/300 • 180 $Q IK MINIMUM 1/300 AT LOWER ROOF - 1/300 • 180 80. IN. MINIMUM 12 41 IRIG:zNT SIDE ELEVATION 1/4' 12 4 TYP EXTERIOR MATERIALS 7 CLASS ' A' COMP. ROOFING ARCHITECTURAL SEE TYP. WALL DET. AT UPPER FLOOR: HARDI SIDING CeT^ii37TZ: 5/16' x 6' WOR. SIDING W/ 5/4X 4 TRIM AT CORNERS - WINDOW TRIM OPTIONAL) 11 4 I Web Site- n .stocktondesign.com E -Mail- tim®stocktondesign.com A•Ip:plpIYCN Di T!<e OIYIINM YWYIY`2 FleYQ.g6 DAllf1:ID DPWIW fd11YCR Y MY41 NIY YO Dt IVa:MRL RAl41 DlNIDa YID VJ10rtIW W 1K JA MD IIM>Q Kt MMfd:V1 p A YR VyY\YIIaIIUII M pR'alC a YO fAd11CW YWH A MK MIY Us REV. 06/4/21 m m n oo mFoA2O ywo 0 za q V Gm at5z nozcQ zmo++m V Eq+ Wp4m Om0Um wyzm o HE> 40 M 9 EM W $ mo NOR 0 9 a+++a 07a-p4., Az .z a OZ9 ga x Q M oyoxo W VoWU VOk, y00i lAWU E+Wf9 000 HE o Q ccmJ o r F 12 4 TYP EXTERIOR MATERIALS 7 CLASS ' A' COMP. ROOFING ARCHITECTURAL SEE TYP. WALL DET. AT UPPER FLOOR: HARDI SIDING CeT^ii37TZ: 5/16' x 6' WOR. SIDING W/ 5/4X 4 TRIM AT CORNERS - WINDOW TRIM OPTIONAL) 11 4 I Web Site- n .stocktondesign.com E -Mail- tim®stocktondesign.com A•Ip:plpIYCN Di T!<e OIYIINM YWYIY`2 FleYQ.g6 DAllf1:ID DPWIW fd11YCR Y MY41 NIY YO Dt IVa:MRL RAl41 DlNIDa YID VJ10rtIW W 1K JA MD IIM>Q Kt MMfd:V1 p A YR VyY\YIIaIIUII M pR'alC a YO fAd11CW YWH A MK MIY Us REV. 06/4/21 m m n oo mFoA2O ywo 0 za q V Gm at5z nozcQ zmo++m V Eq+ Wp4m Om0Um wyzm o HE> 40 M 9 EM W $ mo NOR 0 9 a+++a 07a-p4., Az .z a OZ9 ga x Q M oyoxo W VoWU VOk, y00i lAWU E+Wf9 000 HE Z Plan# 8-21002-3 8—UNIT APT. UD. 21210 800-368-0821 Ckd: TWO o ccmJ o j rl 0 Z Plan# 8-21002-3 8—UNIT APT. UD. 21210 800-368-0821 Ckd: TWO EXHIBIT A, Page 1 of 2Attachment 2, Page 7 of 10 TYP EXTERIOR MATERIAL AT UPPER FLOOR HARDI SIDING OR AT LOWER FLOOR: 5/16' X V HARDI HOR. SIDING W/ 5/4X 4 TRIM AT CORNERS - WINDOW TRIM OPTIONAL) 12 14 ATTIC VENTILATION REQUIREMENTS I/300 AT UPPER ROOF - 1/300 = 180 SQ. N. MINIMUM I/300 AT LOWER ROOF - 1/300 = 180 SQ. IN. MINIMUM 12 14 TYP. CRICKET ROOF UMTS- 2/12 ROOF PIT E 14 TYP. CRICKET ROOF UNITS- 2A2 ROOF PI7 12 14 MW M IM MU MM M IM IM u v ISI MUu v ISIIMMNM REAR ELEVATION ii TYP EXTERIOR N AT UPPER FLOOR: HARDI SIDING OR AT LOUIER FLOOR: 5/16' X 6' HARDI HOP. 5/4X 4 TRIM AT COR -4 WINDOW TRIM OPTION, LEFT SIDE ELEY/47I0N 1/4' .I'-0' DRS. - UNIT h Web Site- w .etocktondeeign.com B-M.l- tim6.tocktonde.ign.com l:lX PVW M! LMIRD io ol! ETtl11.IRKH CRrT M QMNK NG1elClM IBIV CARIX.W:IIW C nu nnn vnveevemcrw`iwewe m ' neume.e..:L .wr • w n DI1WIGtl W l:!!G DPYI.UlYW11YK O.peeCym DIOI.NM fdTlCfCr MWl no r icaev.ielE w.au ver.cw xn mnvmwe r M NA, xn nxsaroa rwr rm® a a„- manw rn M DeA2W! aro momars exaw m Mee DMYM. REV. 0(o/4/21 REv. 01/01/21 a0o W oq G 0 o V W F O Z F yz°CZE® Qw Q6zaVFi qW Q fWLygZzg yLiti mW ypUEm W OmFtGwq mz o 00 m Q 00, 0. c5 ti""ip zV OF x5ooa0r 6O Ly fWr1 O 2 L aHO Z0.G 0 pmpC giiOU U,d jmfs EZZOR Wqm m 00.0 r co C) nr W 16 cc 10 O C) b co F a G Plan# 8-21002-3 8 -UNIT APT. UD. 21210 800-368-0821 Ckd: TWS 10 EXHIBIT A, Page 2 of 2Attachment 2, Page 8 of 10 cnaywi.l o`w Irnaw N' z I I I m o I INo_otivv m^' on°' Tv v mZmpAmO O T CJ '- y O yy m N- Z X x P G> tn N W a z O D p O 0INT1 INTI IOT10 AODZ Z ' +(lzy pvoomna o cti 0 m (J o -c ; o; o2 z om om N A O 'm A Z GJ D A S] .Tml C Tl Zmm mm Spj AT NxI I I Amo zo minm amour ao wmW Z N A N Z m o N Z A A m m m m m m m m m m r t z p p ZO N 0N< mA ZaOCmONDyO mO3z AZ Dp0( yAn D Amti0po( Cn SZ ZOaONCmmDDCD(_ avoDvnmItiOti2NnT0J lpztiC O' ZNffmoioZIA= OZ rn0' D'DJVcDAm~ p yNA I1 ` z< O mNII 0p0zC( O DaTmtiJ I TVmmiAImNDZODO ZDAZC 0Tn`Jp0zyACI1JADypNVxDrrWZo Z imo ZmSmti l 0p0zyACJ IZOjmmSyFWDmpZmmCAyOy<TJ0p0zyACOONJ - pZS S< IamcOmOw Ow om T0J] lO NC yDm =Cm` 52. TCtiNtio OICJJ ydI co^ 1y y A O Ox - pm r_ yKmNZ~ GmmAV. TOm~ Oo Zoz z o` LA JlXCtiAA Z yZmJOenJA- om r zCoOozmOOOmNIow rAAti[ N' ADZnNpimn-JJj -. OTtiOZ Znz< OyDmotiINZmAACc A! ymCZS- nOAV2yr nTXGDIN~` ca A aZ"TJJIIlJ J1 - . TrZIO' AN p IAvZ voZpZmmTVaZyZOIA ONWmOAtiI2nnT-lIIlltl- DA' mOyOti m rvIAoCozA ANypAOtictiIC mNZOZDoz TTXIG[ ti2 JnnIl- J mADAenZOmxVz c m xmmtiy2tNSZZ N DZ? COZ DcoNoJJI' I XyGmAnzti NyAOW Zo< DcDCAxomDymmAnAOVtipymWyOOCASZOmOrnn>JI mvtimZCmyZO Ozom< ZpmAOZp ymNAtiCymtIOiZz m nnJl y, py0CZAnpoAXVCO-rZmJ7jI GmZm Om( zAAOmNIzDrXyLmtiACZNnnJ7timV' m'O' A m o Oz timAOmXC Cram- D( ZpOSm ornnnJJ J OmvNOZnj2A ivAO Dz ZO_ rnm< A rOy mOZCOZptiz znnXNODyAZmyZONmJllZymCCy0ZCOZoo. TCAiADCSNOZpZpm Z OZOON ZJJJJI1' yOtiOymA Cp coN< zozOtim 0OOAyr. TOCIAZOnJIXyLDNr DmADZONm7DOnyZCCOZCym o A(O( aoTV. TmK_~ yxNACmmZI( ammnnn JJl1 Vmm' NpZ( m OAmmC O( o mCpCmINppOZ( ACO z y? nnnTVJJXNOVtiOA ADzI "IDZymCCtiOZAAy mpoZ c oZO? yym rmmC- OONC ZoJllllX( O ZOAyOS OmOzA m O' C( y ozrOzAatioACmv2nZDprOOZCm` C- OZA KnIOvo nnTJJJJJll l AyZpnZp NtimOm o cro imAv. TaA SNmCZNZOtimQ plXVCDOmztiOCAD0mI< Dz T7nCiO. TNm0C2DmvoomvcmNoTZmA tD pG( yOTnZ( CvmzI1nnn'JJJlilll mzGZmmAAmmAzcmtmvzN rZOWS 0cmmSOArmmT0AonJ4Z JlI1 GmmSVZ0m J ll ZoN' m y1 Iy OO III1F( lmo LL1 S27 I'' D0OZzmymAjmop Z( TITcm? AtiNODTn1 Z( myItiIzampNNOaTnniaI p. TxmZC OtiNNal NpZ C' m ZyO. T SOZmmampzOZI~ AO Amzmm>=< Jjl - y A yymCONtiCmOOc' Ooromym- Z OptiZy0 a' A J _ TIA Oac ZO tixmO mOC Nz0~ CZT0A o NI1JJl OmOtiIAptiOZOTODZCDAmozmZN CCtimp O Nxy pTJJJ1l `" P- mONDr CODCZySCOO o ANza XpAmON' za n JJ' l l' 2Dmma c OzC2NtiSCJJ Oym0NAmOmO- nDzGyo ZI CAp ZOyJY- TJJI rZO .O S zG mp0yNSOZIm~ GTWnJJylj FyNyA AO~ mcHDITaAyO-nl zcT ticaAN C tiOIamT0O nJ) l- OWBcZ y om OAOS0ro> OOWOFIJF zOAv pAmZc J TVl I Qp rro m LOCK WALL CO C Gp IM a - T MP V,, n E5 CBLOCK WALL y[ C5 ZNnm Vn mZO Dm OAZWOCT J. OSCm2So DZ4cz7Jn A f~ m2cAmm ATJlII yrr oWy0mtiOWm= zC OT= A mO mAm< ZIAAOT1 C VNOcAmA_ myAOTcmnJI J - A yCZAWopOApAZZCAVAa2NNJJ yoC Zza J yrn= C ZzzmJ, yApoANoDoANpA= ppASNmDsmmy tiO aI~< I TT1l tiDArml m; O OAf ZzGtinoT,Jcl titioOm A tiN_ oOm @® N( I -noWgCJ o• oWCJ_ NIoT D •>` N n - II N(> n-•- -„ JYII: r1 FILBERT LN- . C ~ 3 omomx+ iw\ Oo , I I IIIiIIII IIIIIIIzOa y/\ OlvO yI Imo. I`` 1J l1` Yy mmz IOn( mznJCW OyyIA,_ T 1_ IIiI IIiII, IIiI • li : sI; I 1 o C4y 00 l M,,90X.00N 0zi m -r W4y09 PILE 00' 92 190,bo.Dos 4- EIti El PLANS PREPARED BY: APPROVEDIT 1! I X ZI I I 1 y mµ mxAczi WN> u C( wwnl__ mc N[T__ T yNd% rf THE FAVREAU GROUP SITE PLAN/GRADING PLAN CIVIL ENGINEERING ITN HORACE STREET O w -9 c, 3750 NORWICH AVE. DATE TI = Fq Off' EUGENE, OR 97408 (541) 883-7048 DESIGNED DRAWN c o DATE BY DESCRIPTION APP. TAX MAP LOTS CITY OF SPRINGFIELD' N REVISIONS CHECKED DATE07-31- 21 18-02-05-23-0202 PUBLIC WORKS DEPARTMENT EXHIBIT B, Page 1 of 1Attachment 2, Page 9 of 10 cnaywi.l o`w Irnaw N' z I I I v o No_otivv m^' on°' Tv v mZmpAmO O T O '- y O yy m N< - Z X x P G> tn N W a z O D p O OfN.1 INTI IOT10 AODZ Z ' zy ovoomn' o`i c w m (JO oloT oin ti Nc No p n"'mi Dz cmm ' ono T. vm mm Spy AT NxI I I Amo p A(nANamoTaowmW Z N A rp N I Z m o N Z A A m m m m m m m m m ZnrmND" mmDpSNvA0pCyAAIN' acCAmTn]' I Nr` jZaoC( mO pyyOmO3z AZ a/', OOmA Ao DZpOmrmADTywz{ DAmImyTnTi1I p AtiQpozmm DSoI< SNnAC_ OAoSmDoti yztiA zcZOn O ADDCD( AoDvmm otiSNTn1Ie l I mzti- N ZInAmtOZ r0n( AtiOzmmoa< pDAma pNOaC mmy I OOnANlpmA m mcAWA ommAm zGa> pT sl7,` DNO NCmmti0pmA Wom< pSozAmItiar GCti' OANtiAImtiyAm DZODOtiOZDAZO nJ- i' IlAo( yO( iDFW Zo Z imo zAmti7n p A yD> Aooc I zoTDZOpmm= yrmmDm_ OZ„ mOApp<TCN tiA< rNOZm( pA NCACi AS- 7l7, ] ON mpZA S' 1SmCpZO' O c' Ow om. pon a^ OIy/ 0 OLOrVy.' tii/ Dym 2jlm.Ia OV mO m tO G Wmrnctimym' Zti- j- Zmm v= oA0p Zpz znT` LAS3„ I zoI oaZyZOmnnsvOOenA< DFpZO0OoZDOOmNIOw rAAti[ N' ADZ pimwOJn-sJy Wrn v,- tv.- TtiozoTZOZ< O DmtiINZmAACc A! ymCZS- yOAV2yr wwJnTV zc` Ln( T` 2Dr7A ZpI, l(. Jon - T1tIIl> . I1 Wrn p - oo. TrzNoANySO IANZ vZOZmmTNyZOIA ONWOAtiI2gw vnTT-,aI) I1tl) s- AmAIoyotiDmyrVIApCoz DANyp tictiIC mNZDoz Ten( c'TItizc[ mriy- lnn ll' o , l ADAenzomkVZGC m Atiy2ONSZZ NJDZ? ZS ycoN7 I' I NtizcT] S stiZA NympW Z0< aNDcAmD mmAn0VtipymWyOASZ0mOmmWteJ>'INIz vbmm zOO OZo" ZpmAOZO ymNAtiCymO Zz m oWAelszO, ptiooz~ apO' AVtizcNOrrZmtiI! Ij I zmzmomO( ZASOiTNIz r[ tizctimO A CZNAnTn Il 1 ti VA" o ZIp` O Oz tivAOmXC Cram- n( ZOOmNomA' J- J' I, AvSmvNozav A INxO aZ ZO rnm< A rOyrmOZOZptiz zIn-c^ N Ntizc` 2DtiArmyZONm[ Jl) 1. P ? i pOtiAcotiozpZyOOACAiAaCSNOZOzpm Z OZOO ZJI ytioyKpO CON< zozotim 0OOAyr. TOS CZp, Ili' II. I[ tizc` 2DIyI AZONN" TnnDvSn zocOCIiTTti O A( OVaoTV. TIK_~ ySNACmZ( ammlT' nAA NNJJIIIII LO pOVmmAiOZ( m~ pAmmO O( o mCOCBiTNppOZACO z y? nAAJNtizcVOoazII • JNx1IDIIpOyAcotiozAAD mOOZv c oZO? yyAErmmC- OON Zo0I) l Ww( tizc Z' JOc Om OzvV T oOZ( yC OZOOzAatioAGmv2nZyp OOZOm` C- OZA KniTpvonA• J•lIl EAZcazp CtiWDA< OImro imAv. TDA SNmJZNZOtimQyKpT>WU VI1Vtizc D. TppzOtiCAD0rm< az IliI! ) cZCioAmmCDmtOOSvcmNoTZmA t pG( tipTnZm CvmzIlnnnw! Jc"'JiTAAO C~ Jli) ll l J_ N z tmvzN rZOWS 0cmmSOArmmTOA 7 p- ZmmA zo~ m8n N9 II, i! ZoN 11 1y O IIII mo L1I m7,]' II. mm_ W- r w[ wDm, NpZOmvyyAVjpO , II II!! ZcvTmmLtiSJNNODnl l_ tiII > NN, ZcmymZIAONNNn W a. TxpZCOaAOtiNN n• l I; VI!. I , - OZ . '\•.\ V_ 1I,_ m_ wJ[ TNmWrn 0_mn, NAOT Z> O.T SOZmmmm OmzmAp< AmZ' Ama=< D,_ J o m? N[ ti,O cON_ D N 'Y ANv2wmti mN VNi ror mm? tiCZmOONtiCp"~ OO omymo- Z ogtiozyp]' Ao 1• J; ' Wrn j OUO GZp a' tix mOCo Nzo pzTA O N - p7Ir. 1'? NO , , O ONmAnOtiZOTO' DZODAmozmpZN c mo O ySyrW :' 1,( O(N jW oo2DrCpODCpvzySOOO o AzGn xcA0NZy< v, J N2amy C O zp2NtiSO NOymCZy OTmO- nDzG o Zom AoEzO yJYJJ 0W pU' 1 mx_GIS zc mp0yNSOZImti4To n7 J> Ttlj III I I ` z yNyA AO~ mcHDIT] Atip nJI ZO a N_ 0 IIIIIIIIiI I ZCT ticaAN C tiOIamT0O II IIII IIiIIII IIIIIIIIIIIIIi n' w~ N~ cAmmBCZ y oA OAOS0roW> OOWO OF-] F ZOAv oAmZc o Ej 5 LOCK WALL oe n m m - Tocm T --' MP V,, E5 BLOCK WALL n SI[ omoon< pmoo n=n SON- mNC N — 3 3 00 9z 1„ 90,mms m r GGm, ti> mA? pTpOAo o< D mo, JJ o aVLmOmmyZm Zo q omrN" zEo o< AN nIJ l _ zOOrADz, a AOzxWiOWops a" N DznpCAW cA,- o( S2m5yO yZCAczl7nJ m mm2S mm A' r C 484p 3 A 20 y -T E7 A In 42 ` J m n Cor\D wLl DETENTION POND z - m 30,9. OS 40Bl D:PLANS PREPARED BY: APPROVENo IT 4: IIII'JIII! I" II I1I,, xV< n I! II II1III I a I 9 mµ x< O ocmn OWm Zc OT ci> N C~> wi»nn_-_ OOSmmo Am< ZIAtiAOT.1 Vo( yNoASA y 0c vc/ II Jc tNJJn'_ i ALr`F T yNd% rf THE FAVREAU GROUP SITE PLAN/GRADING PLAN CIVIL ENGINEERING ITN HORACE STREET O w -9 c, 3750 NORWICH AVE. DATE TI = Off' EUGENE, OR 97408 (541) 883-7048 DESIGNED DRAWN c o DATE BY DESCRIPTION APP. TAX MAP LOTS CITY OF SPRINGFIELD' N REVISIONS CHECKED DAi008-20_21 PUBLIC WORKS DEPARTMENT18-02—OS-23-0204 EXHIBIT C, Page 1 of 1Attachment 2, Page 10 of 10