Loading...
HomeMy WebLinkAboutApplication APPLICANT 5/1/2023City of Springfield Development & Public Works 225 Fifth Street Springfield, OR 97477 Site Plan Review S�PNINGFIE Application Type (Applicant., check one) Site Plan Review Pre -Submittal: ❑ Major Site Plan Modification Pre -Submittal: ❑ Site Plan Review Submittal: x❑ I'Major Site Plan Modification Submittal: ❑ Required Project Information (Applicant., complete this section) Applicant Name: BrettYancey Phone: (541) 747-3331 Company: Springfield School District 19 Email• bred.yancey@spnngfield. Address: 640 A Street, Springfield OR 97477 Applicant's Rep.: Enc Favreau Phone: (541) 556-4425 Company: Favreau Engineering Email: favreaueng@gmail.com Address: 2206 Country Haven Dr, Eugene OR 97408 Property Owner: Springfield School District 19 Phone: (541) 747-3331 Company: Email: Address: 640 A Street, Springfield OR 97477 ASSESSOR'S MAP NO: 17-03-35-14 TAX LOT NOS : 11100, 11200, 11300 Property Address: 42510th St Size of Property: 2.71 Acres x❑ square Feet ❑owellina Proposed No. of Units Der acre: Proposed Name of Project: Modular building for cosmetology programiclassrooms Description of If you are filling in this form by hand, please attach your proposal description to this application. Pro oral: Construction of modular building for cosmetology program, trash enclosure, additional parking Existing Use: High School Campus New Impervious Surface Coverage (Including Bldg. Gross Floor Area): 4,300 sf Si natures: Please si nand riot our name and date in the allQronriate Required Project Information (City Intake Staff., Associated Applications: box on the next a e. complete this section) Signs: Pre -Sub Case No.: Date: Reviewed by: Case No.: Date: Reviewed by: Application Fee: $ Technical Fee: $ Postage Fee: TOTAL FEES: $ PROJECT NUMBER: Revised 1/7/14 KL 1 of 11 12.or.us Owner Signatures This application form is used for both the required pre -submittal meeting and subsequent complete application submittal. Owner signatures are required at both stages in the application process. An application without the Owner's original signature will not be accepted. Pre -Submittal The undersigned acknowledges that the information in this application is correct and accurate for scheduling of the Pre- Submittal Meeting. If the applicant is not the owner, the owner hereby grants permission for the applicant to act in his/her behalf. I/we do hereby acknowledge that I/we are legally responsible for all statutory timelines, information, requests and requirements conveyed to my representative. Owner: Date: Signature Print I represent this application to be complete for submittal to the City. Consistent with the completeness check performed on this application at the Pre -Submittal Meeting, I affirm the information identified by the City as necessary for processing the application is provided herein or the information will not be provided if not otherwise contained within the submittal, and the City may begin processing the application with the information as submitted. This statement serves as written notice pursuant to the requirements of ORS 227.178 pertaining to a complete application. Date: 416y Signature Print Revised 1/7/14 KL 2 of 11 1 ENGINEERING April 13, 2023 FINAL SITE PLAN REVIEW NARRATIVE Applicant: Applicants Representative: Springfield School District Favreau Engineering, LLC 2206 Country Haven Or Eugene, OR 97408 541-556-4425 favreaueng@gmaii.com Assessor's Map: 17-03-35-14 Tax Lots: 11100, 11200, 11300 Favreau EnglneeHng 2206 Country Haven Dr Eugene, OR 97408 (5411 556,4425 LAND USE REQUEST The applicant is seeking approval of a new modular building for the school district's cosmetology program located at the Gateways High School Brattain Campus. SITE AND SURROUNDING CHARACTERISTICS The subject site is currently utilized as Gateways High School Brattain Campus. The subject site is zoned Public Land and Open Space. Because the properties to the north, south, and east of the subject property are zoned residential, a Site Plan Review is required. SITE PLAN APPROVAL The applicant is seeking an approval of the construction of a new modular building to host classrooms for the school district's cosmetology program plus required utility connections. The proposal also includes the installation of two new parking stalls. The facility will be ADA compliant and will include an accessible route to the building. The proposed development is compatible with the surrounding developments. The proposed building is setback at least 20' from all neighboring residential zoning. The application also includes the installation of a public fire hydrant along C St south of the proposed modular building. The existing parking area allows for emergency access within 150' of the proposed building. The building has been located so that the entire building is within 400' of the proposed hydrant, measured as the Fire Department's hoses are laid. Therefore the building is not required to have sprinklers. There will be no hazardous materials stored on site as a part of this construction. SITE DRAINAGE The proposed building will discharge roof runoff to splash blocks that will drain into the existing vegetation on the east side of the building. Per the attached City of Eugene SIM form, 860 SF of vegetated filter strip will be required to adequately treat the runoff from the new impervious area. There is approximately 3,970 SF of vegetation between the proposed building and the surrounding building and residential property to the east. Therefore, adequate surface area has been provided to provide treatment. The site does not currently experience drainage issues. Page 1 of 2 F&R E U 2206 uge eryHaven Dr R 47408 (5411 556,4425 APPROVAL STANDARDS (SDC 5.17.125) (A) (1) The proposed land use is a permitted use within the Public Land and Open Space land use district and therefore satisfies this criteria. (2) A discretionary use is not required for this proposed land use. Therefore, this criteria does not apply. (3) The proposal complies with the standards of Public Land and Open Space land use district and therefore satisfies this criteria. (4) The proposal is not in conflict with any approved master plan, master facilities plan, refinement plan, and/or special planned district. Therefore, this criteria is satisfied. (5) The proposal complies with the applicable sections of SDC 4.2, Infrastructure Standards — Transportation. As noted by staff, no public improvements are required as part of this development. All private improvements are designed in accordance with applicable standards. Therefore, this criteria is satisfied. (6) The proposal complies with the applicable sections of SDC 4.3, Infrastructure Standards — Utilities. As noted by staff, no public improvements are required as part of this development. All private utilities are designed in accordance with applicable standards. Therefore, this criteria is satisfied. (7) The proposal complies with the applicable sections of SDC 4.4, Landscaping, Screening, and Fence Standards. The applicant has provided adequate landscaping setback between the ROW and proposed parking area. The landscaping will be planted per City standards. Therefore, this criteria is satisfied. (8) The proposal complies with the applicable sections of SDC 4.5, On -Site Lighting Standards. The proposed building will have additional lighting per the attached plan. Lighting is in conformance with City standards. Therefore, this criteria is satisfied. (9) The proposal complies with the applicable sections of SDC 4.6, Motor Vehicle Parking, Loading, and Bicycle Parking Standards. As stated before, two additional parking stalls have been provided, as required. Therefore, this criteria is satisfied. (10) The proposal complies with the applicable sections of SDC 4.7, Specific Development Standards. Specifically, the standards of SDC 4.7.203 Public land and Open Space do not apply as the proposal is an ancillary building to an existing school. It is not a traffic generator, cause for additional access, it is not a major noise generator, community park, RV park or campground, private/public elementary or middle school, wellness center, or public building and therefore does not trigger any of the additional requirements listed in this criterion. Therefore, this criteria is satisfied. (11) The criteria of SDC 4.8, Temporary Use Standards do not apply as this is a permanent structure for an existing high school campus. Page 2 of 2 SIM FORM: 2014 (Simplified Approach for Stormwater Management) Application Brattain Campus Modular Building Building Permit# Address 425 1 Oth St sf Springfield, OR 97477 Residentia Commercial Tax Lot# 17-03-35-14-11200 Iorcko�e) NRCS Soil Type or sf Measured Infikraiton Rate C Facility Sizing for Water Facility Sizing 4'300 Total Proposed New or Replaced Impervious Surface Area Box 1 Impervious Area Reduction sf Permeable Pavements sf Stormwater Planter Eco-Roof sf x 0.11 = Contained Planter sf sf Tree Credit sf Total Impervious Area ReductionNdBox Box2 Total Impervious Area Requiring Stormwater Managemment 3 IBov l - Box 2) Facility Sizine for Water Quality Only Surface Facilities Impervious Area Managed Sizing Factor Faclity Surface Area Rain Garden sf x 0.05 = Stormwater Planter sf x 0.03 = Swale sf x 0.06 = Vegetated Filter Strip 4,300 sf x 0.2 = 660 Sand Filter sf x 0.03 = Facility Sizine for Water Quality and Flow Control Surface Facilities Impervious Area Managed Sizing Factor Faclity Surface Area Rain Garden sf x 0.11 = Stormwater Planter sf x 0.07 = Sand Filter sf x 0.07 = Facility Sizing for Water Quality, Flow Control and Flood Control "' Only for use in Type A & B Soils Surface Facilities Impervious Area Managed Sizing Factor Faclity Surface Area Rain Garden sf x 0.13 = Stormwater Planter sf x 0.11 = Sand Filter sf x 0.11 = Sum of Total 4,300 Impervious Area Managed Box (Box 4 must be equal or greater than Box 3) Point of Discharge (check one) Overflow to gutter (weephole) Overflow to public storm drain pipe Overflow to Open DrainageX Subsurface Infiltmtion 2014 SIM FORM: Tree Credit and Rainwater Harvesting Worksheet See "Tree Credits" section for more information regarding the use of Reesto meet StorrowMer Impervious Area Reduction. New Evergreen Trees To receive Impervious Area Reduction Credit, new evergreen trees must be planted within 25 feet of the new or replaced impervious surfaces. New trees cannot be credited against rooftop areas. Minimum tree height (at the time of planting) to receive credit is 6 feet Enter number of new evergreen trees that meet qualification requirements in Box A H Bo%A Multiply Box A by 200 and enter result in Box B Box B New Deciduous Trees To receive Impervious Area Reduction Credit new large deciduous trees must be planted within 25 feet of the newer replaced impervious surfaces and new small deciduous trees must be plants! within 10 feet of new or replaced impervious Surfaces. New trees cannot be credited against rooftop areas. Minimum tree caliper (at the time of planting) to receive credit is 2 inches. Enter number of new deciduous trees that meet qualification requirements in Box C Box C Multiply Box C by 100 and enter result in Box D Box D Existing Tree Canopy To receive Impervious Area Reduction Credit existing large tree carppies must be within 25 feet and existing small tree canopies must be within 10 feet of ground level impervious surfaces (cannot be credit against roof top surfaces). Existing tree campy credited towards Impervious Area Reduction must be preserved during and after construction throughout the life of the development. Minimum tree caliper to receive credit is 4 inches. No credit will be given to existing tree canopy located within environmental conservation areas. Enter square footage of existing tree canopy that meet qualification requirements in Box E. F—]BoxE Multiply Box Eby 0.5 and enter result in Box F. JBox F Total Tree Credit Add Boxes B, D and F and enter the result in Box G Box G Multiply Box I of Form SIM by 0.1 and enter the result in Box H. Enter the lesser of Box G and H in Box 1. mals Is the amount to be entered as "nee Credits on Form SIM.) SIM FORM 2014 Instructions 1. Enter square footage (sf) of total impervious area being developed into BOX 1. 2. Enter square footage(sf) for impervious area reduction techniques. 3. Enter sum of the impervious area reduction techniques into BOX 2. 4. Subtract BOX 2 from BOX 1 to find BOX 3, the amount of impervious area that requires stormwater management. 5. Select appropriate stormwater management facilities. 6. Enter the square footage of impervious area managed that will flow into each facility type. 7. Multiply each impervious area managed by the corresponding sizing factor. Enterthis area as the facility surface area, This is the size of faclity required to manage runoff 9. Where selecting facilities that will overflow, select the point of discharge location. 10. Enterthe sum of the total of all the impervious area managed into BOX 4. BOX 4 must be greaerthan or equal to BOX 3. LED 120-27TVAC TECNNO LOeY W 50,000 Hours Life, 18 Watt, Dusk to Dawn Photocell 50,0001rn Minimum Starting Temp .20aCfdaF Maximum Operating Temp LIS HT COLOR Adjustable CCT 3000Kl4000K15000K GRI aooDlK Secunly, Entry Ways, Stairways And Perimeter wARm wHiTB Areas, As Wel1AS Residential Exteriors. . ..ea Dimmable 0.10V • Adjustable Lamp color Switch to: 3000K, 4000K, 5000K Deal h • Dusk to otocell A lum in, in Rust Proof Body • Insta n t St art Electronic Unit • Suitable For Wet Location(I PC 5) • 0-10V Dimmable -150 L60 -120 120 90 90 -60 60 —;od — CO/198, 78.0' -30 30 C90/2)0, 94.2- 0 AVERA= BNAH ANGLE (50%)se. 1 DEG WARRANTY e 2 -YEAR Specification: Input Line Voltage 120-27TVAC InputPower....................................................................................10 W Input Line Frequency, __ ... ....... . BOHz Lamp Life (Rated) 50,0001rn Minimum Starting Temp .20aCfdaF Maximum Operating Temp 45"CM3"F Adjustable CCT 3000Kl4000K15000K GRI 080 Lumens 1000 clicla1043 Dimmable 0.10V seem, Y..._ ceseirs.resse. . Nate'. The curves ndicate the illuminated area and the average illumination when mewminalm is at different distance. Model:# Description wattage lumens 18wnt Hard Wire LED Wall Pack LW1P176]JC0TiP Adjustable SECT, With Pholocell, law 1900 Bronze Finish Cyber Tech Lightil lnc. 331 S. Hale Ave. Fullerton, CA02831 USA. Tel:714-870-0794, 1-877-60CYBER Fax:714-870-0795 www.cybortechlighting.com UPC: 65059658292.2 =0e Mdrok An SPRINGFIELD UTILITY BOARD WATER SERVICE CENTER 202 South l8c' Street, Spnogfeld, OR 97477-52M Tel 541-726-2396 Fax 5U-747-7348 w .subutilxom January 20, 2023 Haley Campbell Development Services City of Springfield 225 5'x Street Springfield, OR 97477 RE: DRINKING WATER PROTECTION APPLICATION EXEMPTION REQUEST - SPRINGFIELD SCHOOL DISTRICT 19 - GATEWAYS HIGH SCHOOL ASSESSORS MAP: 17-03-35-14 TAX LOT: 11100, 11200,11300 ADDRESS: 42510th STREET Dear Ms. Campbell, I have received the exemption request submitted by Favreau Engineering on behalf of Springfield School District 19 regarding the new modular building at the above -referenced address, which lies in the 10 -20 - year time -of -travel zone to the Q Street municipal drinking water well. The hazardous materials Est indicates that the total quantity will not exceed twenty gallons and none of the products contain DNAPLs. Based on the information provided in the request, I recommend that the exemption be granted. Please note going forward that the facility maybe inspected to verify the information provided in the exemption certification. If at any point the conditions of exemption are no longer met, a Drinking Water Protection Overlay District application maybe required. Feel free to contact me at 541-744-3745 for further details or with any questions. Sincerely, Amy E. ©mutz Drinking Water Source Protection Coordinator cc: Eric Favrea4 Favreau Engineering (mail) Brett Yancey, Springfield School District (email) S:\l yChinix\Businesses_ Addresses\Springfield School D lnd\Gateways High School_Brattain Ca.npus\202201-20Gatewa sHigh School -WP Exemption Request Response docx