Loading...
HomeMy WebLinkAboutPacket, DRC PLANNER 4/23/2023 AGENDA DEVELOPMENT REVIEW COMMITTEE DEVELOPMENT SERVICES DEPARTMENT 225 FIFTH STREET Conference Room 616 / MS Teams Staff Review: Tuesday, May 9, 2023 9:00 – 9:30 a.m. 1. Site Plan Review 811-23-000081-TYP2 811-23-000061-PROJ Oregon Urology Institute Assessor’s Map: 17-03-36-22 TL: 6800 & 7000 Address: 1457 G Street Existing Use: medical office Applicant submitted plans for an addition to existing building Planner: Tom Sievers Meeting: Tuesday, May 9, 2023 9:00 – 9:30 virtual meeting via Microsoft Teams The Complete DRC Packet for this meeting is available online for you to review or print out from the laserfiche website: http://www.springfield-or.gov/weblink8/browse.aspx SITE VICINITY MAP 811-23-000081-TYP2 Site Plan Review 17-03-36-22 TL 6800 & 7000 1457 G Street Oregon Urology Institute Revised 1/7/14 KL 1 of 11 City of Springfield Development & Public Works 225 Fifth Street Springfield, OR 97477 Site Plan Review Application Type (Applicant: check one) Site Plan Review Pre-Submittal: Major Site Plan Modification Pre-Submittal: Site Plan Review Submittal: Major Site Plan Modification Submittal: Required Project Information (Applicant: complete this section) Applicant Name: Phone: Company: Email: Address: Applicant’s Rep.: Phone: Company: Email: Address: Property Owner: Phone: Company: Email: Address: ASSESSOR'S MAP NO: TAX LOT NO(S): Property Address: Size of Property: Acres Square Feet Proposed No. of Dwelling Units per acre: Proposed Name of Project: Description of Proposal: If you are filling in this form by hand, please attach your proposal description to this application. Existing Use: New Impervious Surface Coverage (Including Bldg. Gross Floor Area): sf Signatures: Please sign and print your name and date in the appropriate box on the next page. Required Project Information (City Intake Staff: complete this section) Associated Applications: Signs: Pre-Sub Case No.: Date: Reviewed by: Case No.: Date: Reviewed by: Application Fee: $ Technical Fee: $ Postage Fee: $ TOTAL FEES: $ PROJECT NUMBER: Patrick Aldinger Lana Sadler Robertson Sherwood Architects pc 132 E Broadway Suite 540, Eugene OR 97401 541-342-8077 lsadler@robertsonsherwood.com 541-334-3350 Oregon Urology Institute Patrick@OregonUrology.com 2400 Hartman Ln, Springfield OR 97477 G Street Urology Center LLC 541-334-3350 Oregon Urology Institute 1457 G Street, Springfield OR 97477 17-03-36-22 6800 and 7000 1457 G Street 41,112 X X Oregon Urology Institute Radiation Center Addition Addition to existing building - see attached narrative Medical Office 1,485 Patrick@OregonUrology.com X Return to Clayton McEachern @ City of Springfield, email: cmceachern@springfield-or,gov, FAX: (541) 736-1021 CITY OF SPRINGFIELD, OREGON DEVELOPMENT AND PUBLIC WORKS 225 FIFTH STREET SPRINGFIELD, OR 97477 PHONE: 541.726.3753 FAX: 541.726.1021 www.springfield-or.gov STORMWATER MANAGEMENT SYSTEM SCOPE OF WORK Project Name: Applicant: Assessors Parcel #: Date: Land Use(s): Phone #: Project Size (Acres): Fax #: Approx. Impervious Area: Email: Project Description (Include a copy of Assessor’s map): Drainage Proposal (Public connection(s), discharge location(s), etc. Attach additional sheet(s) if necessary: Proposed Stormwater Best Management Practices: Drainage Study Type (EDSPM Section 4.03.2): (Note, UH may be substituted for Rational Method) Small Site Study – (use Rational Method for calculations) Mid-Level Development Study – (use Unit Hydrograph Method for calculations) Full Drainage Development Study – (use Unit Hydrograph Method for calculations) Environmental Considerations: Wellhead Zone: Hillside Development: Wetland/Riparian: Floodway/Floodplain: Soil Type: Other Jurisdictions Downstream Analysis: N/A Flow line for starting water surface elevation: Design HGL to use for starting water surface elevation: Manhole/Junction to take analysis to: --------------------------------- (Area below this line filled out by the City and Returned to the Applicant) ---------------------------- (At a minimum, all boxes checked by the City on the front and back of this sheet shall be submitted for an application to be complete for submittal, although other requirements may be necessary.) ------------------------------------------------- (Area below this line filled out by Applicant) -------------------------------------------------- (Please return to Clayton McEachern @ City of Springfield Development and Public Works; Fax # 736-1021, Phone # 736-1036), email:cmceachern@springfield-or.gov Form Version 5: June 2015 COMPLETE STUDY ITEMS * Based upon the information provided on the front of this sheet, the following represents a minimum of what is needed for an application to be complete for submittal with respect to drainage; however, this list should not be used in lieu of the Springfield Development Code (SDC) or the City’s Engineering Design Manual. Compliance with these requirements does not constitute site approval; Additional site specific information may be required. Note: Upon scoping sheet submittal, ensure completed form has been signed in the space provided below: Interim Design Standards/Water Quality (EDSPM Chapter 3) Req’d N/A All non-building rooftop (NBR) impervious surfaces shall be pre-treated (e.g. multi-chambered catchbasin w/oil filtration media) for stormwater quality. Additionally, a minimum of 50% of the NBR impervious surface shall be treated by vegetated methods. Where required, vegetative stormwater design shall be consistent with design standards (EDSPM Section 3.02), set forth in Chapter 2 of the Eugene Stormwater Management Manual. For new NBR impervious area less than 15,000 square feet, a simplified design approach may be followed as specified by the Eugene Stormwater Management Manual (Sec2.4.1). If a stormwater treatment swale is proposed, submit calculations/specifications for sizing, velocity, flow, side slopes, bottom slope, and seed mix consistent with City of Springfield or Eugene’s Stormwater Management Manual. Water Quality calculations as required in Section 3.03.1 of the EDSPM. All building rooftop mounted equipment, or other fluid containing equipment located outside of the building, shall be provided with secondary containment or weather resistant enclosure. General Study Requirements (EDSPM Section 4.03) Drainage study prepared by a Professional Civil Engineer licensed in the state of Oregon. A complete drainage study, as required in EDSPM Section 4.03.1, including a hydrological study map. Calculations showing system capacity for a 2-year storm event and overflow effects of a 25-year storm event. The time of concentration (Tc) shall be determined using a 10 minute start time for developed basins. Review of Downstream System (EDSPM Section 4.03.4.C) A downstream drainage analysis as described in EDSPM Section 4.03.4.C. On-site drainage shall be governed by the Oregon Plumbing Specialty Code (OPSC). Elevations of the HGL and flow lines for both city and private systems where applicable. Design of Storm Systems (EDSPM Section 4.04). Flow lines, slopes, rim elevations, pipe type and sizes clearly indicated on the plan set. Minimum pipe cover shall be 18 inches for reinforced pipe and 36 inches for plain concrete and plastic pipe materials, or proper engineering calculations shall be provided when less. The cover shall be sufficient to support an 80,000 lb load without failure of the pipe structure. Manning’s “n” values for pipes shall be consistent with Table 4-1 of the EDSP. All storm pipes shall be designed to achieve a minimum velocity of three (3) feet per second at 0.5 pipe full based on Table 4-1 as well. Other/Miscellaneous Existing and proposed contours, located at one foot interval. Include spot elevations and site grades showing how site drains. Private stormwater easements shall be clearly depicted on plans when private stormwater flows from one property to another. Drywells shall not receive runoff from any surface w/o being treated by one or more BMPs, with the exception of residential building roofs (EDSP Section 3.03.4.A). Additional provisions apply to this as required by the DEQ. Refer to the website: http://www.deq.state.or.us/wq/uic/uic.htm for more information. Detention ponds shall be designed to limit runoff to pre-development rates for the 2 through 25-year storm events. *This form shall be included as an attachment, inside the front cover, of the stormwater study. For Official Use Only: As the engineer of record, I hereby certify the above required items are complete and included with the submitted stormwater study and plan set. Signature Date . * IMPORTANT: ENGINEER PLEASE READ BELOW AND SIGN! Oregon Urology Institute Radiation Center Addition Page 1 Final Site Plan Review Narrative April 17,2023 Type II Site Plan Approval Narrative for: Oregon Urology Institute Radiation Center Addition 1457 G Street Springfield, Oregon 17 April 2023 Applicant/Property Owner Architect/Applicant’s Representative G Street Urology Center LLC Robertson|Sherwood|Architects pc 1457 G Street 132 East Broadway, Suite 540 Springfield, OR 97477 Eugene, OR 97401 Phone: 541-334-3351 Phone: 541-342-8077 Attn: Patrick Aldringer Attn: Lana Sadler, AIA Civil Engineer Landscape Architect Capital Engineering & Consulting LLC Cameron McCarthy Landscape Architects 1430 Willamette Street #325 150 East Broadway Eugene, OR 97401 Eugene, OR 97401 Phone: 541-510-4225 Phone: 541-485-7385 Attn: Iris Leia Lorelle, PE, LEEP AP Attn: Justin Lanphear, ASLA Project Description: This application is for site plan approval of a new 1,485 square foot addition to the existing 8,767 square foot (not including overhangs) Oregon Urology Institute Radiation Center. The original development for this site was approved by Site Review Application #DRC2007-00009 on February 28, 2007. The previously approved site plan indicated the addition that is proposed in this application. The total property area is 41,112 square feet and will not change due to the proposed addition. Only the site immediately adjacent to the new addition will be modified as noted in this application. Project Location: The project site at 1457 G Street is located on the south side of the 1400 block of G Street between 14th and 16th Street. The existing Oregon Urology Institute Radiation Center is a flag shaped property comprised of two tax lots on Map #17-03-36-22. The flag portion of the property is Tax Lot 6800 facing G Street. The flagpole portion of the property is Tax Lot 7000 at the southeast corner of the flag property and extends to F Street. Approvals Requested: Type II, Site Plan Approval Attached Information (included in this package): Type II Site Review Application (1 copy) Site Review Narrative (3 copies) Stormwater Scoping Sheet and Report (3 copies) Geotechnical Report (3 copies) Copy of the Deed 8-1/2x11 version of Site Plan (Sheet L100) Drawings (4 copies) G100 Project Information G200 Exterior Elevations L000 Existing Conditions Plan L100 Site Plan L200 Grading Plan L300 Irrigation Plan L400 Landscape Plan L500 Details C100 Civil Stormwater Management Plan Oregon Urology Institute Radiation Center Addition Page 2 Final Site Plan Review Narrative April 17,2023 Project Use: The facility is a combined radiation and immunotherapy clinic with associated offices. The total number of full-time equivalent employees is 8 with a couple of per-diem employees. The number of employees is not anticipated to change with this addition. Hours of Operation: Normal operating hours will range from 8:00 AM to 5:00 PM, Monday through Friday, except holidays. Zoning: The site is within the Springfield City limits and is zoned GO, General Office. The site is designated within the Hospital Support Overlay Zone. A medical office building use is a permitted outright in both the General Office Zone and Hospital Support Overlay Zone. Adjacent Uses: The property to the east along G Street is zoned Low Density Residential. That property is currently the McKenzie Willamette Hospital employee parking lot. The properties to the west along G Street are zoned Low Density Residential. G Street Integrated Health, a medical provider facility, extends to 14th Street. The property to the north, across G Street, is zoned Mixed Use Commercial and is the McKenzie Willamette Hospital. The two properties to the southwest are zoned Low Density Residential. The easternmost of those properties is vacant and the westernmost of those properties contains a single- family residence. Hospital Support Overlay Zone: The purpose of the hospital support overlay zone is to provide, among other things, hospital related support services. The urology radiation center meets this criterion. The design standards for the Hospital Support Overlay Zone noted in Springfield Development Code Section 3.3.1125 are as follows: (1) All yard, lot/parcel size, coverage, density, fencing, parking standards shall be subject to the same standards as professional offices in residential districts. Per City of Springfield Development Code Section 4.7.190 Professional Offices in Residential Districts: (A) Professional offices in residential districts are permitted when: (1) The lots/parcels are adjacent to CC, MUC or MRC Districts; and The property is located adjacent to the Mixed Use Commercial district located to the north, across G Street. (2) The majority of the square footage of the structure on the lot/parcel is not more than 100 feet from CC, MUC or MRC Districts. Where public-right-of-way separates the residential district from the commercial district, the right-of-way width is not counted in the measurement. The main frontage of the building is located 65’ from the north property line. (B) A professional office exceeding 2,000 square feet of gross floor area shall abut an arterial or collector street. The main frontage of the building faces G Street which is a collector street. (C) No parking shall be permitted within the front yard setback. Required parking shall be screened from the public view. No parking is located within the front yard setback. All parking along the side and back yards are screened from the adjacent residential zones with fully established arborvitae hedges. The hedges were planted during the initial construction of the building in 2005. Oregon Urology Institute Radiation Center Addition Page 3 Final Site Plan Review Narrative April 17,2023 (D) For structures on the Springfield Historic Inventory, any external modification shall be fully compatible with the original design. The building is not on the Springfield Historic Inventory. (E) Professional offices permitted are limited to: accountants, architects, attorneys, computer programmers, designers, engineers, insurance agencies, investment counselors, licensed real estate agents, medical and dental practitioners, counselors, planners, and studios for artists, interior decorators and photographers, and similar general office uses engaged in support services to their businesses and/or their parent companies. A professional office used for medical practitioners is a permitted use. (F) A minimum of 25 percent of the lot/parcel shall be landscaped The landscape area covers 11,494 square feet (27%) of the 41,112 square feet total lot area. (2) A minimum of 25 percent of the lot/parcel shall be of planted material. The landscape area covers 11,494 square feet (27%) of the 41,112 square feet total lot area. (3) Parking lots shall meet the planting standards applicable to commercial development. All off-street vehicle parking will conform to the standards listed in SDC Sections 4.6-110 through 4.6-120. Site Access / Public Transportation: Primary site access is provided along G Street. Public transportation is available from a bus stop 0.2 miles to the west of the site along G Street. A second bus stop is located near the emergency room entrance of the McKenzie Willamette Hospital along Mohawk Boulevard, also 0.2 miles from the site. According to Lane Transit District, no additional transit stops are planned within 1/2 mile of the property. Traffic Impact: According to the Institute of Transportation Engineers (ITE) Trip Generation Manual, the average daily trips for a medical office is 36 per 1,000 square feet. At 10,252 sf (including the addition but excluding roof overhangs), this ratio results in 369 daily trips. The ITE’s peak hour trip rate for medical offices is 4.79 per 1000 square feet. This results in 49.1 peak hour trips. Both numbers are well below the threshold to require a traffic impact study. Off-Street Parking Facilities: The property has two separate parking lots. The north parking lot is accessible along G Street and connected to the main entry of the building. The north parking lot has 22 standard parking stalls and 4 accessible parking stalls. The 4 accessible parking stalls are located closest to the building’s entry. The south parking lot has 12 standard parking stalls with access from F Street. This is a total of 38 parking stalls. According to SDC 4.6.125, the 10,252 building (including addition but excluding large roof overhangs) requires a minimum of 34 parking stalls at 1 stall per 300 SF of building area). Since there are no planned changes to the parking lot area, the project does not propose any revision to the number of parking stalls. Bicycle Parking: The building area after the addition is 10,252 SF (excluding large roof overhangs). According to SDC 4.6.155, 0.75 bicycle parking stalls are required per 5,000 SF of building area. This results in two (1.54 calculated) required parking stalls. One short term (0.39) and one long term (1.15) parking stalls are required. There are 18 existing ribbon style bicycle parking stalls located under the building’s northeast covered area. There is a sidewalk connecting the bicycle parking stalls and the public right-of-way along G Street. The new project does not propose any changes to the bicycle parking. Phased Development: The addition to the building and the associated site work will be completed in one phase. Oregon Urology Institute Radiation Center Addition Page 4 Final Site Plan Review Narrative April 17,2023 Exterior Lighting: The existing light poles and building mounted exterior lights were approved in the site review application for the original building. No modification to existing lighting or addition of new lighting is proposed. Utility Infrastructure: The existing site development includes connections to power, natural gas, storm water, domestic water, and fire protection water lines. Refer to attached Sheet C3.0 of the original construction documents. The existing connections have been found to be sufficient to support the new addition. Easements: Refer to the existing conditions plan for description of the existing easements associated with the project. No changes are proposed for the easements. Stormwater Management: The existing stormwater treatment on this site was previously approved on the Site Review Application #DRC2007-00009. The new stormwater treatment that we propose only addresses the impervious structure from the new addition. Wetlands: The property is not in areas identified in the Springfield Local and National Wetland Inventory Map. Drinking Water Overlay District: The site is within the 10-year and 20-year time of travel zones as shown on the City of Springfield’s Wellhead Protection Area Map. No additional hazardous materials will be present on site due to this addition. While the clinic portion of the building is sprinklered, no sprinklers are proposed within the addition. The property is currently engaged in a drinking water protection agreement with the Springfield Utility Board and will maintain the terms of this agreement. Signs: No changes to existing exterior signage is proposed.