HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-11-28Main Office Salem Office P.O. Box 21814 4060 Hudson Ave., NE Tigard, Oregon 9728 I Salem, Oregon 97301 Phone (503) 684-3460 Phone (503) 589-1252 Fax (503) 684-0954 Fax (503) 589-1309 TEST SPECIMENSREPORT OF 6 X 12 CONCRETE Test Methods: Date Molded: ASTM C31lCt72 / Cte2 / Cett / CtO64 / C231-/ C1-43 t7/28/2005 permit X. 2OO5 -01182 Bend Officc P.O. Box 79 l8 Bend, Oregon 97708 Phone (541) 330-9155 Fax (541) 330-9161 Job Number: s0504s33. client: WESTERN CONSTRUCTTON SERVTCES rNC Address:4223 MAIN STREET SPRINGFIELD OR Contractor: WESTERN CONSTRUCTTON SERVICES INC Jurisdiction; S PRINFTELD Subcontractor:Cast By:S. FENTON Concrete Supplier: Truck #: 281, EUGENE SAND & GRAVEL INC weather: cLouDY /cot o Admix/Amt: Load #: 1 Test Time: 11:15 AI4 Ticket#: 311938 Air Temp. at Sampling Time: 31 oh Lir: 1- so? Max Agg:3/8" Cylinders were cast for the following locations: FOOTING AT COLUMN LINE 2, DETATL 1,8, AND 4 Total Concrete Placement Location: FOOTINGS AT COLWN LINE 2 Strength Requirement:3 000 psi fc@ 28 Days Slump: 5.000" MixNumber: 13-6 SACK Conc. Temp: 51 Cement Type:3 Register Number: 0002 834 Lab Location. SALEM Average fc @ 28 days Set No. 'l'est @ Days Date Rec'd Test Date Total Load Area Unit PSI Type Of Fracture Tested By 7 1,1,/2e /2O06 t2/os/2005 57885 28 .1,7 241,0 3 SRT 2B Ta/2e/2006 1,2/26/2006 105375 27.60 3820 6 JDV 2B 1,1,/2e/2006 t2/26/2006 95800 27.60 3 510 5 JDV 2B Lt/2e/2006 1,2/26/2006 107700 27.50 3900 )JDV 37 40 Please see reverse side for additional information. / Carlson Testingr lnc. - ''"'""""''"'";::::;:,:;';:",::,:;::; Project: SAVE ALOT FOOD STORE - SPRINGFIELD CubicYards: 5's JobNumber. s0504533. RegisterNumber: 0002834 Project: SAVE ALOT FOOD STORE SPRINGFIELD < I in. [25 mm] Type2 Well-Formed cone on one end, vertical cracks running through caps, no well-defined cone on other end Date Nlolded: t) /28/20o6 Type 3 Columnar vertical cracking through both ends, no well-formed cones Type 6 Similar to Type 5 but end ofcylinder is pointed Type I Reasonable wel l-lormed cones on both ends, less than I in. [25 mm] of cracking through caps Type 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type I I Type 5 Side fractures at top or bottom (occur commonly with unbonded caps) Asterisked (*) average unit PSI test results did not meet listed acceptance criteria. Remarks: CC. WESTERN CONSTRUCTION SERVICES INC CITY OF SPRINGFTELD - BUII,D]NG DEPARTMENT ABHT STRUCTURAL ENGINEERS - RANDALL TOMA WESTERN DESIGN GROUP _ GARY YOUNG Project Manager:B. LEACH Reviewed By: Brian Leach Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this reporl is prepared. No parfy other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document.