HomeMy WebLinkAboutPermit Building 1985-05-08.. RESIDL IIAL..
APPLICATION /PERILIT
225 North Sth Street
Springfield, )regon 97477
BUL Ldl-ng DLuLsLon
7 26-37 53
?D
t#
SPTTINGFTELD
e
Constmtebion Lender
r^t ia the reeponsibi-LilV oi-tne pentit holder to eee thrut aLL inspecti,one oe nad.e at *he ptope" tine, that ecch =44ress is reaCab:-eftotn the st?eet' and that the permit catd ie Located at the frcni of the orooertu.*Bui'!-ding Dioicion appro"*ed plan shclL remain on tlp Bunl,ding sitc'at "1t'1tk2"."PI?).EDUPE F1R INSPECTI)II-.E!9IES!.'CALL726-3769(recordet,) state yout City desigrnted. job nwnber:, job aCi;z,ess, type of inspeczicn
:.1Ynl!.d and.aken gou uiLL be readg fon inspection, contractcz,s o-t, a,tners tnneLnd plnne nunbcr. -Requests rcLe.ti;Za b|1cre'z:ag an'**rLL be nade the sane dag' "equests nade aftet, 7:00 an uLLL be nade tke naat aorkinq'd.ay.
your CitA Desigr,ated. Job Nttnber fs: 8; O 3 7 ?Reottinerl fnsoeeticns
3?. dJob Locaticn:I
AssessorsMap# /7aZ ->d 34 o{Z-ot)?cr Lot #
Subdioision
Or.mer:
/15! 4, 53,/IAddtess:Phone
Date of Applieaticn
S Pernla f l€L
Describe I'lotk:K r* RER-*e-g,rnsitrf
ci V
t-t
t-t Home
Value *&roo.
q?*f 11 *3oAdditian
RemoCel
Contractot,s Address Lisc.
GeneraL
STTE INSPEC?ION:Io be nade aftet,
pt"iot, tc set up ofeecauation, but
fotrne.
TNSALATTON/VAPOR BARRTER IT\SPECTION :
To be made aftet, aLL insulaticn ad.
required oapor baviers @e in place
but before oty Lath, Wpsun boarC or
unLL couering is qplied, and beforeoty ittsulation is concealed.
DRTWALL TNSPECTTON: Tc be made
aftet, aLL dtyuall is in place,
but pz'ior to ang tapirq.
MASONRI: SteeL Location, bond
beans, gz,outing or oez,ticals in
aceordotce ?,/ith U,B.C. Section
24L 5.
WO)DSTOI/E: After instalT,ation ie
ccrnpleted.
DEtl1LrTrAlt 0R
Sanitazg seuer capped ct properug* Line
Septic tutk p'anped and filled tith gta.;el
FLnaL - Itrylen abcue itens ore cc:nleted
a-d uhen dernclition is cornplete'oy sty.,te-tute notsed and. prerrises cleaneC up.
ANDERSLAB PLUMBTNG, ELECTRICAL &t,zcit_ltcWnu
aork ie cortet,ed.
FO)Irilc & F)ANDATTCN: Io be twdeafter trenchea a?e escaoated and.
fornrs are erected, but prior to
pouz*ing ccncrete.
UNDERGROUT]D PLUMDTNC. SEWP., W,4TER.
DRAIIIAGE: To be made pr"Lor to f.LL-lirq trenches.
P1ST AND BEAM: To be nade pr"Lot, toiliffiTatGn of floot, insulZtion ot,
decking.
CURB & AI|PR)ACH APPON: After fortnsee ez,ecteC but prior to pouz,in4
R)UGH PLA|BtN?. ELE?IRICAL & MECH:
ANfCAL: No uork is to be couet,edwttil these inspeetions. ltaue been
nade and appz,oted..
FTPEPL,ACE: Ptior to placir4 facingmaterials and before froning i,nspec-
tdon.
FRA].!fNC: l,tust be requested after
@fiouat of rough pl,kbing, eiectti-cal & meelwnical. ALL roofing
braaLng & chinmeue, ete. mtst be
completed. llo wbrk is to be con-
.., eealed until this inspectton lwstbeen made anC approued.
AIIDERELOOR PLUIIBIIIG & MECIIANTCAL:rob@oy
floor insulation or decking.
FTilAL PLUABTNG
FINAL ASCHANICAL
FINAL ELECTRICAL
concy,ete.
SIDEWALK & DRf,,EWAI: Foz, aLL con-
crete paoing uithin street right-of-uay, to be made aftez, aLL exca-
oating canplete & forn ttotk & sub-
base matey,ial in place.
IENCE: tathen complate -- Prouide
gatee oz, notsable sections through
P,U.E.
ALL proiect conditions, such as the installation of etreet trees, corpletion of therequired Landsceping, atc. ' nust be satisfied befote the BUILDIN-G EINAL can be requested..
a\ PnNAL B.LTLDING:- The Ft).nal Build,irry Inspection m.$t be |equested after the tinal plunbing
\--l Electrical, otd. Meelwnical fnspeetions haue been nade ard'approued.
llobile Ecnes
Blocking and. Set-up
Plunbing connections -- sare! @1d. Date!
Eleetrical Ccnnection - Bloeking, set-up
and plurnbing conneetions nust be apprct:ed
before requesting eleetrLcal inspecliol
Aeeessory Buildirq
pct ekes, skirting, decks,Firal - After
ete. are eomp.
Page 1 of 2
*ALL \LAIIHCLES AND CLEANOUTS MUS? BE ACCESSTBLE, ADJaSTltEtlt To BE LL4DE AT NO ClST rO Cry
T
tr
7 solAF-€cEss REe.-^*(,JOB NO.L-CO
Bedroons:
Lot Faces -Lnzradu botflccs
Setbaeks Heat
Df House Cataqe Access.Water lleaterNot:th
East Fireplace
South Waodstoue
% of Lot Cooerage_fnterior
Cormer
Panhanl.Le
CUL-de-sac
# of Stories
Total Height
Iopograplry
LCT TWEIot Sq. Ptg.
Ilest
-- Fees --
ruEM ttu x Va Building Volue & Permit
Ihis pernnt is granted on the etpv,ess condition that the said consttaction
sLnLL-, in all rZspeets, eonform to the Cy,dirnnce adopted 6:y the City of
SpringfieLd, including the Zoning Crdinance, regulating the ccnstructicn
and. use of buildings, cnd may be suspen-d.ed or reuokeC at cnlJ time upon oic-
Lation of anA prctsisions of said 0ydi.r,ances.
TOTAL VALUE
S.D.C. L.5 a *
Building Pe?tni,t (,u o Cheek Fee:
State Date Paid:
q qG Reeeipt #:Total Clarges Signed:
rTEM NO.FEE CHARGE Plumbing PermPictuz,es t
Resilential (L bath)No pe?eon sltall construct, instal!., alter ot cltange anA ned cr ecisting
plznbing or dtainage systan in uhole or in patt, unlees such pet,son is the
Legal posseasor of a ualid plumber's License, escept that a pelson nag do
plwnbing uork to p?ope?t! uhieh ts oumed, Leased or operated by the dppli-
eant.
Sani Seuer
Plwnbing Penri.t
State
*
Electricol Permit
Where State Laa requiz,es that the electri-cal uork be done by qrt Elecfieal
Contraetor, the electricaL portion of this permit shalL not be oaliC until
the l.abel lns been sigzed by the Elecfu,ical Contractor.
TotaL
FEE
Permit
*
N a,t /Ext ettd. C ir cui t s
Setwice
NC FEE ffII DTF
,+
Mechqnicol Permit
llcodstotse
Vert Fot
tuhanat Hood
B?U,
Pennt t Issuffiee
Mechanical Pev,mit
-- ENCROACHMENT .-
Sec,u.Lty Deposit
Storage
Maintenance
Permtt
-
Cvrbeut
Sida,talk
.oence
LLect?I,CAL LabeL
Mobile Horne
PLan Enanlne?Date
?otaL
I HAw CAREFULLY EYAILINED tle eornpleted appltcation fo? pennit, md do
hereby certify that aLL information hereon is true anl eorrect, crtd I
furtket' eertify that any ard aLL uork perfotrned slnll be done in accor'-
dance'"vtth the Ordinances of the City of Spz'ingfield, and the La:,;s of the* State of 1z,egon pertaining to the wrk Cesu'ibed herein, end tlnt N0 )CCU-
PANCI u17-L be nad.e of any structure uithout permission of the Building N-
oision. f further certify that only contractors and e.nplcyees uho ate in
eonpliance uith )RS 701.055 uiLL be used on this pt,oject
{-v-ff
TOTAL AMOUNT DUE:*3q 16 Date