HomeMy WebLinkAboutPermit Building 1998-06-01CO]I/I M ERCIAL/I N D USTRIAL
PERMIT APPLICATION
225 Fifth Street, Springfield, Oregon g7477
SPFIiIGFTELO
JOB NUMBER J
INSPECTTON LtNE: 726_3769
OFFICE: 726-3759
LOCATION OF PROPOSED WOBK:/vzu *l7o
ASSESSORS MAP:
rAX Lor D0Z0 /
PHONE:<2 tLr//
STATE:ZIP:/)IZE /-,,
OWNER
CITY:
VALUE:DEMOLISH OTHER
DESCRIPTION OF WORK:
NEW
-
REMODEL ADDITION
NAME ADDRESS PHONE
EXPIRESlo rJn,s /U li'Ba,t7 t (c t2l l- ov
PLUM BI NG:
GENERAL:
ADDRESS
PHONE
CONTRACTOR'S NAME
ARCHITECT:
MECHANICAL
ELECTBICAL:
CONST.
CONTRACTOR #
Single Fixture
Relocated B
ew fix
ce
ft.
ewerary
ft
erorm
ft.
Backflow Device
I
THE WORK
NOT
TOTAL P
NO FFF
F urnacei burner & vent
BT
UTF'nac e burne &r ntVE
1 BTU
Floor furnace and vent
oormounted unit heater
pen or
an evary p.
Icoo er
Vent Fan/Single
duct
Mechanical exhaust
hood and duct
Permit Issuance $10.00
TOTAL PERMIT
- OFFICE USE _
ZONING
LIGHTING POWER BUDGET:
LAND USE:
OCCY GROUP:
* OF STORIES:
QUAD AREA:
* OF BLDGS:
CONSTR. TYPE:
HEAT SOURCE:
HANDICAP ACCESS:
-FLOOD PLAIN:
WATER HEATER:
SQ. FT.$/SQ. FT.VALUE
X
X
X
TOTAL VALUE OF PROJ
SQ. FTG MAIN
SQ. FTG ACCESS
SO. FTG OTHER
z8,q 3 RCPT#PLAN CHECK FEE DATE BY
bz6. fil
BUILDING PERMIT PLU M BI NG tf u.o,t DEMOLITION
5% State
Surcharoe
5% State
Surcharqe
7.o.t
J 1-r
MECHANICAL FENCE
VALUE $
5% State
Surcharge
SIDEWALK
FT,
SUBTOTAL
PERMITS $t. *a
PAVI NG Lf q.n CURBCUT
FT.
SYSTEMS
DEVELOPMENT 510.b
TOTAL PERMIT FEES
EXCLUDING ELECTRICAL
ADDRESS:
c
EHA tr':E
Appllance vent
separate
Vent System apart
-
from AC or htg.
g OF UNITS:
I
REOUIRED INSPECTIONS
It ls the responsiblllty of the permit holder to see that all lnspectlons are made at the proper time' To request an inspection' call
726-g76g(recorder), state your city designat.Jrou nu-uer, job aooress, iype ot inspection requested and when you will be ready
for inspection. ReqLrests ieceivedbefor. 7,OO a.m. wi, be made the same working day, requests made after 7:00 a'm' wirl be made
the following work Jay' 6^,r^u Dr rrn, (- pAvrNG: After gravel is in
SITE INSF'ECTION: To be ROUGH PLUM-BING' -l
made after excavation, but gieCrntcal a ' \ place but prior to placing
prior to srrtup of forms. rraEcnAr'rrcnL: No work is to asphalt or concrete
be covered until these
UNDERSLAB pLuMBtNG, inspections have been made sPEclAL INSPECTioNS: ln accordance
ELEcTRtcAL & .nTipbio'eo' Section 306 of the State Specialtv Code
MECHANICAL: To be made :';," ;""tt a special inspector shall be emploved
berore an1' *oin is covered' tl,'J?^?^?t[J.sroPs
& :liiffi.;f ii,?:'1ff1;;,0,.'n''X'3'n' o ,,
"opy of the special testing reports shall
FOOTINGS & FOUNDATIONS: FtREpLACE: Prior to placing be'furnished to the Building Division'
To be macle after trenches are facing materials and before
excavated and forms are frami-ng inspectlon. STRUCTURAL CONCRETE: ln
erected, all steel in place, but excess of 2500 P.S.l. (306 a.1)
Prior to Placlng concrete'
CONCRE]'E SLAB: To be
made after all inslab building
service ec uiPment, conduit'
PiPing, accessories and other
incillarY €'quiPment items are
ln Place but before any
concrete ls Placed'
UNDERGROUN D: Plumbing'
electri , sanitarY sewer,
water and
es. To be m ade
prior to covering or filling
FRAMING: To be made after
the roof, all framing, fire
blocking and bracing are in
Place and all PiPes, chimneYs
and vents are complete and
the rough electrical, Plumbing
ind me-cnanical are aPProved'
INSULATION & VAPOR
BARRIER: To be made after all
insulation and required vaPor
barriers are in Place but
before any lath or gYPSUm
board interior wall covering is
aPPlied.
FIRE & SEPARATION WALL:
Located and constructed
according to Plans'
LATH AND/OR GYPSUM
BOARD: To be made after all
lathing and gYPsum board'
Interior and exterior, is in
Place but before anY
irlastering is aPPlied or before
gYPSum board loints and
fasteners are taPed and
f inished.
SIDEWALK & DRIVEWAY:
Required for all concrete
Paving within street right of
way, to be made after all
excavating comPlete and form
work and sub-base material in
Place.
CURB AND APPROACH
APRONS: After forms are
erected but Prior to Placing
concrete.
STRUCTURAL WELDS:
Performed on the iob' (2722 l')
HIGH STRENGTH BOLTING:
Durlng all bolt installation and
tightenlng operations' (306
a.6)
SPRAYED ON
FIREPROOFING: U'BC'
Standards 43-8.
SPECIAL GRADING'
EXCAVATION AN D FILLING:
During earthwork. (306 a'11 &
Chapter 29)
GLU'LAM BEAMS: lnsPection
Certificate bY an aPProved
agency, furnished to the City's
Building Division before
beams are Placed. (2501 U'BC'
srDs. 25-10J1).
STRUCTURAL MASONRY: (306
a.7\
trenches.
UNDERFLOOR: Plumbing,
electrical, mechanical' To be
made Prior to installation of
floor insu atlon, decking or
floor sheathing'
POST & BEAM: To be made
Prior to lnstallatlon of floor
insulation' decking or floor
sheathing.
FLOOR ]NSULATION &
VAPOR B/\RRIERS: To be
made Prior to installation of
decking or floor sheathing'
MASONR'!/: Steel location,
bond bearns grouting or
verticals ir accordance with
uBc 2415.
ROOF SHEATHING AND
NAILING: Prlor to installing
anY roof coverlng.
'ln addition to the insPec-
tions specified, the Building
Official may make or reguire
other inspections of anY
constructlon work to ensure
compliance with the Building,
City or Development Code.
By signature, I state irnd agree, that I have caref ully examined the completed appllcation and do hereby certify that all information
herein is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances
of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY
will be made of any structure without permission of the Bullding Safety Division. I further certify that only contractors and employees
who are in compliance with ORS 701.055 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that project address is readable from the
street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all
times during constrL ction.
Signature Date4*:a;*- d, 6o-zr
*1zo s 7VALIDATION g
do
AMOUNT RECEIVED:
RECEIPT *:RECEIVED BY:
DATE PAID:
)<. FrNAL PLITMBtNG
FINAL ELI:CTRICAL
FINAL MECHANICAL
FINAL FIFE OEPARTMENT
SITEPLANREVIEwBoARD:MUstberequested2daysinadvance
ofthedateyouwishinSpection.Allprojectconditionssuchas
landscaping,parkinglotstriping,etc.mustbecompletedbefore
requestlng this insPection.
FINAL BUILDING: Requested after the final plumbing, electrical,
mechanical and Fire Department inspections are made and
approved. No occupancy of the premises can be made until a
iertificate of Occupancy has been issued by the Building Division
and posted on the Premises.
ADDITIONAL COMI\I ENTSi
PLANS REVIEWED BY DATE
,08 NO. ?,o*f-ol
ATTACHMENT A
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE
WORKSHEET
NA}4E OR COMPANY
,L
LOCATION
DEVELOPMENT TYPE 4JJ /r-irr,t /^ ^oz b t " rLt
/
BUILDING SIZE Ft
t)
sroRM DRAINAGE - ,.t/eo /H,^1 ' ,2/{O 5F
IMPERVIOUS SQ FT. ,9 /f,o X $0.226 PER SQ. FT
2. SANITARY SEI^IER-CITY
NO. OF PFU'S X $46.86 PER PFU
(See Reverse Side)
3. TRANSPORTATION
NO OF UNITS X TRIP RATE X COST PER TRIP
x x $412.49
x $472.49
x $472.49
1
4.
NO. OF FEU'S . X
5. ADiIINIST,,RATIVE.FFES
BASE CHARGE (SUBTOTAL ABOVE) X .05.
OT SIZ
$
(
$
$
PER FEU + $10 MWMC/ADM FEE $-
$
TOTAL-MWMC SDC $
s-?952
X
X
MI^IMC CREDIT IF APPLICABLE (SEE REVERSE)
SUBTOTAL (ADD ITEMS 1,2.3 & 4)
$/"4
i naton
Date -r'7 i TOTAL SDC
9o$47d-
/4-- b,4*"sd'1
FTXTURE Ul\llT CALCUL "--lON TABLE: Number or New rir," -" X Unit Equivarent =(NorE: For remodels, calculate only tne NET additional fixtures)
vrrrr Lr{urv"rent = Fixture Ucts
FIXTURE TYPE
Bathtub.....
Drinking Fountain. ........
Floor Drain...................
lnterceptors For Grease/Oil/Solids/Etc
lnterceptors For Se nd/Auto
Laundry Tub/Clothr:swasher
Wash/Etc
Clotheswasher - 3 Or More...
Mobile Home Park frap (1 per Trailer)......
Receptor Fcir Refrigerator/Water Station/Etc
Receptor For Comnrercial Sink/Dishwasher/Etc..
Shower, Single Stall...
Shower, Gang.........
Sink: Bar, Commerr:ial, Residential Kitchen...........
Urinal, Stall/Wall... ............;...
Wash Basin/Lavator,y, Single........
Toilet, Public lnstallation.
, Toilet , Private....
NUMBER OF
NEW FIXTURES
TOTAL FIXTURE UNITS
lf improvements occurred
Year
Annexed
x$ .
(Rate X Assessed Value)x $_
(Rate X Assessed Valuel
UNIT
EOUIVALENT
FIXTURE
UNITS
/Head
2
1
2
3
6
2
,6
6
1
3
2
1
2
2
1
6
4Miscellaneous:
CREDIT CALCULATION TABLE Based on assessed value
calculate credits rates
Credit for Parcel or Land Only lf Applicable
lmprovemen': (if after annexation date)
after annexation date in table,
Rate per $1,OOO
Assessed Value
CREDIT TOTAL $
Year
Annexed
Rate per $1.OOO
Assessed Value
1979 or before
't9BO
1 981
1 982
1 983
1 984
1 985
1 986
$3.97
3.89
3.83
3.70
3.55
3.39
3.20
2.91
1 987
1 988
1 989
1 990
1 991
1 992
1 993
1 994
1 995
1 996
$2.56
2.17
1.73
1.31
o.92
o.v4
o.61
o.45
o.31
o.17
RUNOFF COEFFTCTENTS FOR STORM DRAINAGE
(For Estimating purposes Onlyl
Residential...;............
Commerica|...............
,...,,. o.4
lndustrial.......
Governmental
o.9
o5
o.5
IMTIERVIOUS AREA : TOTAL LOT SIZE X RUNOFF COEFFICIENT
ll---