HomeMy WebLinkAboutPermit Building 2022-10-13DEVELOPMENT AND PUBLIC WORKS 225 FIFTH STREET 6LOREGO GFIELD SPRINGFIELD, OR 97477 Building Safety Section (541) 726-3753 Fax (541) 726-3689 www.springfield-or.gov N Residential Conditions of Approval October 13, 2022 PROJECT: Address: 2596 27th Street Permit No: 811-22-001979-STR Occupancy: R-3 Construction Type: VB Reviewed in accordance with 2021 ORSC Area: Upper Floor (810 sq ft) Occupant Load: Sprinklered: Fire Alarm: Plans submitted for the proposed construction at the above project address have been reviewed for conformance with the City of Springfield building safety codes. The following items are conditions of approval: 1. The existing space does not meet minimum head height per section R305 of the 2021 ORSC, therefore minimum room sizes also cannot be met per section R304 of the 2021 ORSC. Per the applicant this has been used as habitable space as long as the current owner has owned the property and it was not a converted attic space. The structural joists supporting the upper floor are unverifiable since the space is finished. Per the applicant, the owner has chosen to exercise their exemption from minimum room size requirements by the use of ORS 455.320 in which they are required to record these documents with the county clerk to be ttached to the deed. 2. Maintain all safeguards during construction. 3. Approval of these drawings does not acknowledge that the project meets structural building codes addressing minimum room sizes or temperature levels and does not include approval of or permits for any electrical, plumbing or mechanical work. Separate application(s) for permit(s) are required for such work. ISSUANCE OR GRANTING OF A PERMIT OR APPROVAL OF PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR APPROVAL OF, ANY VIOLATION OF THE BUILDING SAFETY CODES OR OF ANY OTHER ORDINANCE OF THE CITY OF SPRINGFIELD. ANY CHANGES OR ALTERATIONS made after the date of this review must be approved by the Building Official. Thayne Smith Plans Examiner I Inspector tsmith@springfield-or.gov rt1 cfa SA = SMOKE ALARMS SA SMOKE/CARBON CO = MONOXIDE ALARMS As required by Sect. R314 &,R315 of the 2017 ORSC EXI5TING LIVING 5PAGE UPGRADE5 UPDATE AND REFRESH DRYWALL PAINT ADD NEW FLOORING ADD BATHROOM FIXTURES ADD CABINETS. RDD BATHROOM FIXTURES TO EXI5TING ROOM 53'-811/16" 2'-8 112" —13'-4 15/1 F SA 52-111 1 1/16" SA co 41 o 1 o i � 1 b'-4 3/8" 53'-6 11 /1 b' EXISTING STAIRS 24'-11 1/6" EMERGENCY EGRESS REQUIREMENTS FOR'SLEEPING ROOMS Per section R310.1 of the 2021 ORSC - Basements and every sleeping. room shall have not less than one operable emergency escape opening. That opening shall open directly to a public way, or a yard or court that opens to a public way. Per section R310.2.1, that minimum opening area shall have a net clear opening of not less than 5.7 square feet. The net clear height shall ne not less than 24" and the net clear width shall be not less than 20" . Sill height shall not exceed 44" from finished floor.. Q'_ 12-10 13/1b" - 11' 9 3/8" �X 1ST 11'�LG� i�l OiJ G.C�>� GoM P `t A!-t'T l�i�STAttiZ.S '�P.4L1�c i3tE1+-� ez, t..aD Ag "As& TDC=*ES t-jp'T 1 mr-s T "l N % 1- toVA C M I S -1W-4, iz--:?=ca • 1) cm- "%u3 % 1✓iw M fltMicNSIC+-1 C1�P� ©t~ "i'H tS t�oLu R^ 1�T W 1�-t TN L Ga.�l>ti TY b�+lr—_t�-- t—lEtZ 02S 1455 . 3Za . 0-r*4ri.- �-tA► ;W �. .Z►t.t. >-tr_-e t'Z'1F_ MM tE::I1-4Qt. L t-d1T Bull Lts 1i1.1� c::nT>L Izr=eQ • m W 0 z 0 DATE: 8/9/2022 SCALE: S H EET: P=1 "