Loading...
HomeMy WebLinkAboutPacket, Pre PLANNER 10/4/2022Completeness Check Meeting Development and Public Works Department Reern 61 COMPLETENESS CHECK MEETING DATE: Tuesday, October 11, 2022 11:00 a.m. - 12:00 p.m. Zoom + DPW Conference Room 616 Completeness Check Meeting (Site Plan Review) #811 -22 -000220 -PRE 811-22-000128-PROJ Assessor's Map: 17-03-22-20 TL: 1300 & 1600 Address: 3350 Gateway Street Existing Use: motel/parking Applicant submitted proposal to construct restaurantwith dual drive thru lanes. Planner: Andy Limbird Meeting: Tuesday, October 11, 202211:00— 12:00 via Zoom + DPW Conference Room 616 MIRA VICINITY MAP 811 -22 -000220 -PRE Development Issues Meeting 17-03-22-20 TL 1300 & 1600 3350 Gateway Street Steve Schwartz Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 2.0 PROJECT SUMMARY 2.1 Existing Conditions The project site is approximately 4.49 -acres of Community Commercial (CC) zoned land and further identified as tax lots 17-03-22-20-01300 and 17-03-22-20-01600, herein referred to as the "Project Site". The project site is located at the southwestern intersection of Randy Pape Beltline and Gateway Street and generally consists of level terrain between 0-3 percent slopes. The project site is developed with an existing motel and restaurant building, approximately 42,906 square feet, built in the early 2000s. The project site is considered two legal lots as described in the preliminary title report and vesting deed included with this application as Appendix 2. The project site is designated as Community Commercial (CC)with no overlay districts or natural resource features. Surrounding lots to the north, south, east, and west are designated as CC and have existing commercial buildings. Surrounding land also includes fully developed roads and city utilities along street frontages. According to Springfield's Transportation System Plan (TSP) Functional Classification Map (Figure 2), Gateway Street is considered a minor arterial with no on -street parking, and the northern extent of Randy Pape Beltline is considered a major arterial with no on -street parking. Access to the site is provided from Gateway Street and no access is provided from Randy Pape Beltline. Drive aisles of varying widths provide access for internal traffic circulation to the motel and restaurant building. Additional access and utility information are provided later in this narrative. A Type II Site Plan Review subject to approval by the Director or staff is required. Therefore the applicant is requesting approval through the Type II Site Plan Review procedure for the proposed Chick-fil-A. A Site Plan Review Application form is included with this submittal as Appendix 1. Surrounding uses are identified in Table 1 below. Table 1: Surrounding Uses 4013WL. Page Zoning Use North CC Communit Commercial South CC Community Commercial East CC Community Commercial West CC Community Commercial 4013WL. Page Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Fri OOWL Pages Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 2.2 Previous Approvals The project site has four previous records located online. • 811-22-000128-PROJ (Prior Chick-fil-A Request): Expired • 811 -22 -000127 -PRE (Prior Chick-fil-A Request): Pre -application Conference • 811 -19 -000265 -PRE (Master ProjecUMayhew Redevelopment): Pre -application Conference • 811-19-000266-PROJ — (Master Project/Mayhew Redevelopment): Expired 2.3 Project Description The applicant proposes the construction of a new 4,987 square -foot Chick -fl -A restaurant with dual 26 -foot -wide drive-through lanes and associated improvements in the northeast corner of the project site. Two future pad sites are proposed in the southeastern and northwestern areas of the project site. The applicant is seeking approval for the first phase of development only (restaurant with drive-through lanes). The anticipated timeline and specified use for future phases are unknown and will therefore be requested through a separate application in the future. Site improvements include the removal of the existing motel and restaurant facilities, repaving of the parking lot, new curbing and traffic marking, and new perimeter and interior parking lot landscape planters. A total of 83 parking spaces will be provided for Chick-fil-A customers (of which 81 will be standard stalls and two (2) will be ADA -accessible parking spaces). Traffic will enter the site via Gateway Street (minor arterial) and a private driveway to the south and west from two right-in/right-out drive aisles that connect to a series of on-site drive aisles adjacent future pad sites and the proposed restaurant with drive-through lanes. Drive-through lanes enter south of the main entry for the restaurant and parking lot, travel along the eastern property line, up to the pick-up window along the northern extent of the restaurant building before terminating within the new parking lot. Existing city utilities (water, sewer, and stormwater) are extended and available on tax lot 1600. Tax lot 1300 does not have an existing water line. As such, comments from the Springfield Utility Board (SUB) are included with this application as Appendix 3, including comments and recommendations for the extension of a water line from the southeast. Therefore, the applicant requests approval to use existing facilities readily available to support the proposed restaurant. A property line adjustment application has been prepared and submitted concurrently with this site plan review application package to request the relocation of the western property line to maintain the required setbacks and prevent the restaurant from straddling any property lines. Ileo 13WL. Page Type II Site Plan Review (Pre -Submittal) I Chick-fil-A #04967 3.0 SPRINGFIELD DEVELOPMENT CODE (SDC) The applicable development code provisions are set forth below with responses demonstrating the project's consistency with these provisions. Chapter 3 Land Use Districts 3.2-300 Commercial Zoning Districts 3.2-305 (8) Community Commercial District (CC). 3.2-305 (B) Community Commercial District (CC). The CC District establishes sites to provide for a wide range of retail sales, service, and professional office use and also includes all existing strip commercial areas. 3.2-310 Schedule of Use Categories. "P" = PERMITTED USE subject to the standards of this Code. "S" - SPECIAL DEVELOPMENT STANDARDS subject to special localional and/or siting standards as specified in Section 4.7- 100_ "D" . DISCRETIONARY USE subject to review and analysis under Type III procedure (Section 5 9-100) at the Planning Commission or Hearings Official level. "N" = NOT PERMITTED SITE PLAN REVIEW SHALL BE REQUIRED unless exempted elsewhere in this Code. Response: The project site is zoned CC. The development of a drive-through restaurant is a permitted use in the CC zone per the Schedule of Use Categories. Responses demonstrating the project's consistency with the commercial development standards are provided in subsequent sections of this narrative. 4013WL. Page Commercial Dismore Use Caw,desNses NC CC MRC GO Ealing and Drinill EmblishmenM Cocklallxunges P P p N Delicatessens and sit down restaurants Includina es rewo shops Section 47-1,15) P P p 5 Dope up restaurants and espresso shops P P P N Tavems and brew pubs 0 P p N Response: The project site is zoned CC. The development of a drive-through restaurant is a permitted use in the CC zone per the Schedule of Use Categories. Responses demonstrating the project's consistency with the commercial development standards are provided in subsequent sections of this narrative. 4013WL. Page Type II Site Plan Review (Pre -Submittal) I Chick-fil-A #84967 3.2-315 Base Zone Development Standards Response. The project site and abutting lots are zoned CC. The restaurant building is located on two tax lots which combined are approximately 4.49 -acres in size with more than 50 feet of street frontage. The building is proposed ten feet or more from all property lines, with no architectural features anticipated to extend more than two feet into the required setback. A review of standards related to lot coverage, landscaping, and parking are addressed later in this report. 'lleo13WL Page Commeeial Zoning District Development Standard NC CC MRC GO Minimum Area 6.000 square feet 6, 000 square feet6.000 squarefeet 6.000 square feet Minimum Street Fronlage(1) 50 feet 50 lead50 feet 50 feet AO Panhandle LotvParcels Minimum Steen Net Permanent 40 feet Net Pmmiaed Not Permitted Frontage Maximum LaVParcal Coverage Development Areas 1 A. and 2 Aaes- Labia el coverage limited onty by standards Nome, 35 percent Oavalopment Meas between Sections sidle Cade. 2 antl 3Aaes- 35 pail and no single lease space shall exceed 15 000 square feet Minimum Landscaping Perimeter and Interior landscaping area Minimum requomems defined by standards in often combined coverage shall not be less Nan SefLons of this Code. 20 percent of me total development area. Maxknum Perking, loading and vehicular 45 percent Laeparcel coverage limited onty by standards M oMer circulation area average Sections of this Code. Landscaped Se baths (2)(3)(4) and (5) Front Street Side Yard, and Through Lon Rear Yard Building Setba t 10 Feet 10 Feet 10 Feet 10 Feet Paddng, driveway, and me! .... Smile 7 Feel 5 Fed 5 Feet 5 Feet setback Interior Safe, Rear Yard S deaths when Abuming Residential or Cl Distils Building Setbatlt 10 Fed 10 Feat 10 Feet 10 Feat Pelting, Driveway Omdoor Storage 7 Feet 5 Feet 5 Feet 5 Feet Setback Maximum Budding Height(6) 20 Fast No Maximum, except as specified belew When a butting an MR or MDR District to 20 Feet Defend hymn Maxanum Shade Pant Heigmrecommuche at the nosh Saddled 2-225410, sup to 50 foul "da mwNom Istel he. a pare mbnding sash wM as state N23 degrees and onglnala, man Ne lop of a 16 loin hypodermal fence coed on Ne noMem seemed lie. When abutting an UDR or MDR Direct to 20 Feet No greater Man MatpelmMed in me MR or MDR Carl ler Me east, wed, or scum a dividends of 50 feet Response. The project site and abutting lots are zoned CC. The restaurant building is located on two tax lots which combined are approximately 4.49 -acres in size with more than 50 feet of street frontage. The building is proposed ten feet or more from all property lines, with no architectural features anticipated to extend more than two feet into the required setback. A review of standards related to lot coverage, landscaping, and parking are addressed later in this report. 'lleo13WL Page Type II Site Plan Review (Pre -Submittal) I Chick -til -A #94967 3.3-200 Drinking Water Protection Overlay District 3.3-210 Applicability As of May 15, 2000, all areas within specified wellhead TOTZ automatically are rezoned to add the DWP Overlay District to the underlying zoning district. The areas to which the DWP Overlay District is applied are shown on the Drinking Water Protection Area Maps on file in the Development Services Department and incorporated in this Section by reference. Response: The project site is located in the Five Year Time of Travel Zone (TOTZ) in the Drinking Water Protection Overlay District as identified in the Map 3 of the Drinking Water Protection Area. Therefore, this section is applicable and responses are provided as required. 3.3-220 Time of Travel Zones A. The DWP Overlay District includes 4 TOTZ: 0-1 year; 15 years; 5-10 years; and 10-20 years. The locations of the TOTZ for each wellhead are shown on Drinking Water Protection Area Maps on file with the City's Development Services, Public Works, and Fire and Life Safety Departments; and Springfield Utility Board (SUB) and Rainbow Water District (RWD). Response: The project site is located in the Time of Travel Zone (TOTZ) five (5) year in the Drinking Water Protection Overlay District as identified in the Map 3 of the Drinking Water Protection Area. 3.3-225 Review A. A DWP Overlay District Development Application is required when the criteria of both Subsections A.1. and 2., below are met: 1. A site is affected by one of the following: a. There is a change of land use, occupancy or tenancy of a property, including, but not limited to: a change from vacant to occupied; or b. During the Building Permit process; or c. In conjunction with any development application, including, but not limited to: Site Plan review and Minimum Development Standards. Response: Existing conditions on the project site include a vacant motel and Elmers Restaurant. The applicant's anticipated plans include demolishing both structures and building a new restaurant (Chick -fl -A). An existing conditions and demolition plan is included with this application as Sheet C1.0 of Appendix 4. Future uses of Pad -A and Pad -B are unknown at this time and therefore, are not included in this site plan review application or Drinking Water Protection (DWP) Application Exemption Request. Therefore, the applicant anticipates future Pad - A and Pad-Bwill be subjectto reviewthrough a DWP Overlay District Development Application at a later point in time. 4013WL. Page Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 The Chi ck-fil-Arestaurant will replace the existing restaurant (formerly Elmers) and therefore, no change of use, occupancy, or tenancy of the property is proposed with this application. Disposal of hazardous materials is anticipated to be similar to those practices currently used for Elmers. 2. The action in Subsection A.1., above will: a. Affect the storage, use, and/or production of hazardous or other materials that pose a risk to groundwater; or b. Increase the quantity of hazardous or other materials that pose a risk to groundwater that are stored, used and/or produced. Response: The Chick -fl -A restaurant will replace the existing restaurant (formerly Elmers). Disposal of hazardous materials is anticipated to be similar to those practices currently used for Elmers. Chick-fil-A uses cleaning, sanitizing, and disinfecting chemicals that are EPA -registered products. Cleaning solvents, degreasers, and other cleaning chemicals are disposed of in accordance with the manufacturer's label, Safety Data Sheets, and local, state, and federal regulations. Through daily use, cleaning chemicals are disposed of in the sanitary sewer in diluted forms. Should bulk containers need to be disposed of, the containers will be taken to a permitted local hazardous waste recycling facility. B. Prior to the submittal of a DWP Overlay District Development Application, an exemption request may be submitted to the Director as specified in Section 3.3-23013.1. Response: No change of use is proposed with this application and no new hazardous materials are anticipated thatwould cause a risk of contamination to groundwater. Therefore, the applicant has included an exemption request from the DWP Overlay District Development Application, including with this application as Appendix 9. Chapter 4 Development Standards 4.2-100 Transportation 4.2-105 Public Streets (B) An applicant may be required to prepare a Traffic Impact Study (TIS) to identify potential traffic impacts from proposed development and needed mitigation measures. ATIS is required if any of the following criteria are met: (1) Peak Hour Threshold. If a change in land use or intensification of an existing use generates 100 or more trips during any peak hour as determined by procedures contained in the most recent edition of the Institute of Transportation Engineers Trip Generation Manual, a TIS must be performed by a registered professional engineer. Response: This site plan review requests approval for a new restaurant facility to replace the existing restaurant (Elmer's). A Trip Generation Assessment Memo provided by Kittleson and Associates for the project site (Chick -fl -A #04987) indicates a Ileo 13WL. Page 10 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 marginal increase in average daily trips and hourly peak trips at full buildout of the project site, assumed retail uses for Pads A and B. However, as previously stated, this application requests approval for the restaurant facility, which will have fewer average daily and peak hour trips than the existing uses as reflected in Table 2 of the memo. A copy of this technical memorandum is included with this application as Appendix 7. Therefore, the applicant concludes the proposed use will not generate 100 or more vehicular trips during any peak hour, and a Traffic Impact Study (TIS) is not required. (2) Average Daily Traffic Threshold. If a change in land use or intensification of an existing use generates 1,000 or more trips per day as determined by procedures contained in the most recent edition of the Institute of Transportation Engineers Trip Generation Manual, a TIS must be performed by a registered professional engineer. Response: This site plan review requests approval for a new restaurant facility to replace the existing restaurant (Elmer's). A Trip Generation Assessment Memo provided by Kittleson and Associates for the project site (Chick -fl -A #04987) indicates a marginal increase in average daily trips and hourly peak trips at full buildout of the project site, assumed retail uses for Pads A and B. However, as previously stated, this application requests approval for the restaurant facility, which will have fewer average daily and peak hour trips than the existing uses as reflected in Table 2 of the memo. A copy of this technical memorandum is included with this application as Appendix 7. Therefore, the applicant concludes the proposed use will not generate 1,000 or more vehicular trips per day, and a Traffic Impact Study (TIS) is not required. (3) Variance and Known Issues Threshold. The Director may determine that a TIS is necessary to support a request for a Variance from the transportation provisions of this code or where traffic safety, street capacity, future planned facility, or multimodal concerns may be associated with the proposed development. Response: No variance from the transportation provisions is requested with this application. Therefore, this provision does not apply. B. An applicant may be required to prepare a Traffic Impact Study (TIS) to identify potential traffic impacts from proposed development and needed mitigation measures. ATIS is required if any of the following criteria are met: Response: The applicant has included a Trip Generation Assessment Memorandum prepared by Kittleson and Associates with this application as Appendix 7. The applicant concludes that traffic generated from the proposed use will not be substantially different than existing traffic levels generated from the existing use and therefore requests confirmation of the need and scope of a TIS. C. Minimum street curb -to -curb widths and minimum street right-of-way widths are as specified in Table 4.2-1 unless otherwise indicated in the Springfield Transportation System Plan, an applicable Refinement Plan, Plan District, 400WL Page 11 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Master Plan, Conceptual Development Plan, or the adopted bicycle and pedestrian plan; where necessary to achieve rightof-way and street alignment; or as needed to meet sitespecific engineering standards, including but not limited to requirements for multi -way boulevard and/or modern roundabout designs. Example street layouts meeting minimum street standards are provided in Figures 4.2-13 through 4.2-V for illustrative purposes only. These Figures are intended to demonstrate potential street configurations that meet the requirements. Table 4.2-1 Minimum Street Right -of -Way and Curb -to -Curb Standards Response: No modifications to the existing right-of-way and curb -to -curb standards is anticipated to result from the applicant's proposed driveway location. The existing full movement driveway on Gateway Street is expected to be limited to left-in-dght- in-right-out movements and new cross-over accesswill be provided connecting the site to commercial properties to the west and south. D. Street Network Standards—General Criteria. 1. Collector and Arterial Streets. Subject to the standards of this code, the location of collector streets and arterial streets must comply with the Transportation System Plan, including the Conceptual Street Map. Response: No modifications to Gateway Street are proposed with this application. The applicant proposes several internal drive aisles to facilitate access throughout the site and to the proposed Chick-fil-A restaurant and drive-through. IE313WL Page 12 Tneal bearably FM. RIgMM-Way Cu@10 Cure 7.61 Lanes Tum Lane SMq and H. street Classllkalum (1) wade (1) Lanes Wki VAON(2) 91keudautp) Cure (1) sidexew 4vt i4blted 43&D Me, Adenal(5) 14952'/84' 7BM9' L 12' hua 6'bel 5' Teen sloes e1M ie 42 EG MucaMesd(5) 75'/68.69 521/44'M 2 12' 6 W sloes 5 ' 7'aoM SMfls req'a�er 4.2 NJ Mader Colleda 7.I64'l56' 52/10'/36 2 17 lam. 6'take sides 5• 5- note sides requ ed Minor CollWor-Nam 4.2 K- 13'efiere Residential Zoning roBY50' S9I1Y21' 2 it 8'boM Sills 5 5'boM SMes M expense DlsMds (8) MlnorCdedor- 13'e9ere 4.2 N -P Resleena6l Zoning M'159M2' 35'/392.2 4' WA 5' 5'Win sides M,xM4 DaMM(6) Lool5tree1 X15 pefceM 42Q5 5.7.719.14' M'28'70' 2 19 WA Not required 5' 5'aoM tleas Node (7) Loral Sheet x15p bt 4.2 T -V y149132' 362a'2o' 2 19 WA Not requVed 6 -curbs only 5'both sees Value (7) Sar CuFde-sacauM 83•dlemeYr 79 diarbeler WA WA NIA WA 5'arwnd bulb Noy 29 =qft�f WA WA WA Nolrequlred Nulrequlred Response: No modifications to the existing right-of-way and curb -to -curb standards is anticipated to result from the applicant's proposed driveway location. The existing full movement driveway on Gateway Street is expected to be limited to left-in-dght- in-right-out movements and new cross-over accesswill be provided connecting the site to commercial properties to the west and south. D. Street Network Standards—General Criteria. 1. Collector and Arterial Streets. Subject to the standards of this code, the location of collector streets and arterial streets must comply with the Transportation System Plan, including the Conceptual Street Map. Response: No modifications to Gateway Street are proposed with this application. The applicant proposes several internal drive aisles to facilitate access throughout the site and to the proposed Chick-fil-A restaurant and drive-through. IE313WL Page 12 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 2. Local Streets. The local street network, which includes pedestrian accessways and multiuse paths, must meet the following standards: Response: No local streets are proposed with this application. 3. Dead -End Streets. Response: No dead-end streets are proposed with the redevelopment of the project site. Therefore this provision and Subsections a — b are not applicable. 4. Block Length and Block Perimeter. a. Block perimeter for all street classifications must not exceed the following maximums, except as provided or exempted elsewhere in this Code or in an applicable Refinement Plan or Plan District: iv. 1,600 feet in other zoning districts. Response: The project site is located in the CC zoning district and the block perimeterwill not exceed 1, 600 feet. b. Block length must not exceed: 600 feet for local street not in industrial zones or that do not serve industrial nonconforming or the maximum block length established in an applicable Refinement Plan or Plan District, whichever is less; Response: The project site is located in the CC zoning district (considered other zoning between Subsections i -iii) and the block length will not exceed 600 feet. 5. Maximum Street Grades. Street grades must not exceed 8% on major and minor arterial streets, 10% on major and minor collector streets, and 12% on local streets. Response: No new roads (private, collector, or arterial) are proposed for this project site. All local drive aisles will be graded to be level, with slopes well below 12%. A grading plan is included as Sheet C3.0 of Appendix 4 reflecting proposed grading throughout the project site. Medians. 1. General. A raised median physically deters vehicles from crossing or entering a median area by way of a raised curb or concrete barrier. Raised medians help avoid crashes caused by crossover traffic, reduce headlight glare distraction, prevent traffic turning left from through lanes, provide refuge for pedestrians crossing the street, and remove turning traffic from through lanes, thereby maintaining efficient and safe traffic flow. Median design and installation must follow the standards in the Manual on Uniform 'lleo0 WL Page 13 Type II Site Plan Review (Pre -Submittal) I Chick-fil-A #04967 Traffic Control Devices and AASHTO's "A Policy on Geometric Design of Highways and Streets." Response: No medians are proposed for new internal drive aisles on the project site. However, preliminary discussions with the City indicate the existing raised median on Gateway Street will need to be shifted north to accommodate the proposed driveway location entering the project site. A Project Improvement Plan (PIP) is anticipated as a condition of approval for this project. The width, size, and length of the relocated median are anticipated to remain the same as the existing median. G. Additional Right -of -Way and Street Improvements. 1. Whenever an existing street of inadequate width is abutting or within a development area requiring Development Approval, the dedication of additional right-of-way is required. Whenever street dedication results in the right-of-way that does not connect with the City street system, a deed restriction shall be recorded with the Lane County Deeds and Records stating that the property shall not be built upon until a fully improved street is constructed to serve the property, and connect with the City street system. Response: Preliminary discussions with the City during a pre -application conference (811-22- 000127) indicate Gateway Street is not underdeveloped or inadequate and would not require street frontage improvements at this time. Therefore, subsections two through five are not applicable. 2. Whenever a proposed land division or development will increase traffic on the City street system and the development site has unimproved street frontage, that street frontage shall be fully improved to City specifications in accordance with the following criteria: Response: No land partition or development is proposed that would increase traffic, as mentioned previously. In support of this conclusion, a trip generation assessment memo drafted by Kittleson and Associations is provided with this application as Appendix 7. Table 4.2-1A Special Street Setbacks Streat Classlaoabon Sataaok Distance from Ne Cantanlna (q Major Anerlal 50' Minor Arterial 38' Major Collector 36' Mlnor Colleabr 35' Local Street, <16 percent slope 28.5' Local Street, 215 percent sbpe 25' Alley 10' 4013WL. Page 14 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 (1) Where fully improved right-of-way abuts the property line of the subject property, the setback distance is one-half of the width of the existing, fully improved right-of- way. Response: Preliminary communications with the City indicate the right-of-way abutting the eastern property line (Gateway Street) is fully improved. The Chick-fil-A building is proposed 51 feet from Gateway Street (considered a minor arterial) and exceeds half the required right-of-way width specified in Table 4.2-1A. The Chick -fl -A building is not adjacent to Beltline (major arterial) and therefore exceeds half the required right-of-way width specified in Table 4.2-1A. 4.2-120 Site Access and Driveways A. Site Access and Driveways—General. 1. All developed lotstparcels are entitled to one approved driveway access provided by either direct access to a: a. Public street or alley along the frontage of the property; or Response: The project site has three access driveway locations. The primary way traffic will enter the project site is from Gateway Street. The driveway access from Gateway Street will be limited to left -in -right -in -right -out movements and new cross-over access will be provided connecting the site to commercial properties to the west and south. 2. Driveway access to designated State Highways is subject to the provisions of this Section in addition to requirements of the Oregon Department of Transportation (ODOT). Where City and ODOT regulations conflict, the more restrictive regulations shall apply. Response: No access to the project site is proposed from a designated State Highway. 3. As determined by the Director, sites with abutting parking areas within the same zoning district may be required to provide driveway connections or pedestrian connections internal to the sites and joint access agreements to provide efficient connectivity and preserve public street functions and capacity. Response: Driveway connections and pedestrian walkways are shown on the site plan included as Sheet C2.0 of Appendix 4. It is the client's intention to obtain a reciprocal access agreement on the southern drive aisle per this requirement. B. Driveways must take access from lower classification streets when development sites abuts more than one street and streets are of differing classification as identified in the Springfield Transportation System Plan. 4E30WL Page 15 Type II Site Plan Review (Pre -Submittal) I Chick-fil-A #04967 EXCEPTION: Driveway access to or from a higher classification street may be permitted if no reasonable alternative street access exists or where heavy use of local streets is inappropriate due to traffic impacts in residential areas. Response: Driveways to the project site will take access from the lower classification street, Gateway Street. No access is proposed from Beltline. No exemptions are requested with this application. C. Driveways shall be designed to allow safe and efficient vehicular ingress and egress as specified in Tables 4.2-2 through 4.2-5 and the City's Engineering Design Standards and Procedures Manual and the Development & Public Works Standard Construction Specifications. Table 4.2-2 Response: The project site has three access driveway locations. The driveway accessing the project site from Gateway Street is a right -in -right -out, 32 -foot -wide driveway, with no variation in throat width. The transitional width on the eastern driveway goes from 32 -feet -wide to 29 -feet -wide, consistent with the transitional width specified in Table 4.2-2. The western and southern driveways are right -in -right -out, 29 -foot - wide and 24 -foot -wide driveways, respectively. Driveway width and throat depths are the same as overall width, and therefore are consistent with the transitional width and throat width specified in Table 4.2-2. Table 4.2-3 Driveway Design Specifications 1.way Driveway 2 -way Drivewayz Width Width Radius of Curb (2) Driveway Throat Depth Land Use MinN., MiNMas. Mes. Sioglefamily and Duplexes (3) (41 12'716' 12'-af(1)NA. NA. NA. NA Multifamily Residential 26165' 118'CommercldWubg[ Mu6lfamlly Residential 24 feel 30 feet Land(4)(5) 12916' 24135'(1)1Intlusldal 60 feet CommarciaVPublic Land (6) 12118' 26T35'n)18'(2) 35 feet Go feet Response: The project site has three access driveway locations. The driveway accessing the project site from Gateway Street is a right -in -right -out, 32 -foot -wide driveway, with no variation in throat width. The transitional width on the eastern driveway goes from 32 -feet -wide to 29 -feet -wide, consistent with the transitional width specified in Table 4.2-2. The western and southern driveways are right -in -right -out, 29 -foot - wide and 24 -foot -wide driveways, respectively. Driveway width and throat depths are the same as overall width, and therefore are consistent with the transitional width and throat width specified in Table 4.2-2. Table 4.2-3 (1) Wider driveways may be permitted to accommodate traffic demands and/or to improve traffic safety. (2) Greater curb radii may be permitted where high volumes of large trucks are anticipated. (3) Measured from the face of the curb to the first stall or aisle. 400WL. Page 16 Curb Room Dries" Design Specifications Driveway WMth(1) Radius of Curb (2) Driveway Throat Dep1h lend... (3) tend Use Min. Mac Min. Mes. Single -Family and Duplexes NA. NA. NA NA. NA. Mu6lfamlly Residential 24 feel 30 feet 10 feel 20 feel 60 feet CommarciaVPublic Land 24 feet M feet 15 feet 35 feet Go feet Industrial 24 feet 35 feet 15 feet 35 feel 60 feel (1) Wider driveways may be permitted to accommodate traffic demands and/or to improve traffic safety. (2) Greater curb radii may be permitted where high volumes of large trucks are anticipated. (3) Measured from the face of the curb to the first stall or aisle. 400WL. Page 16 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Response: Vehicular access to the site will be provided from both Gateway Street and multiple internal drive aisles and private roadways within the commercial development site to the south and west, which are within existing reciprocal access easements. New internal drive aisles will be 24 feet wide or greater and allow for turning radii of 20 feet measured from curb to curb. A site plan is included with this application as Sheet C2.0 of Appendix 4. Table 4.2.4 Minimum Separations Between a Driveway and the Nearest Intersection Curb Return an the Same Side of the Street (1) Land Use, Street Type Atterlal Collector Local Single -Family Residential and Duplexes 200 feet 50 feet 30 feet Nulffamily Residential 209 feel IDO feet 75 feet CommerciaOPablic Land 209 feet 1DD feet 75100[ Induellial 200 feet 200 feet 150 Seel (1) Each category of street is considered separately. Distances may be reduced in the following circumstances: (a) Access is from a one-way street. (b) The driveway is marked for "right -in -right -out only." (c) The driveway is marked "exit only" and is designed to prevent left turns. Response: Vehicular access to the site will be provided from both Gateway Street (minor arterial) and multiple internal drive aisles and private roadways within the commercial development site to the south and west. The right-in/right-out access driveway from Gateway Street is 147 feet from the nearest intersection curb, consistent with this provision. (d) In cases where an existing lotiparcel and/or use make compliance with these specifications unreasonable, a new driveway or an existing driveway required to be relocated by this Code shall be placed at the furthest point from the intersection curb return, considering both safety and internal circulation requirements of the development. Response: Compliancewith these specifications is feasible, as specified above. Thereforethis adjustment does not apply. 4013WL Page 17 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #84967 4.2-125Intersections Intersections shall be designed and constructed as specified in the City's Engineering Design Standards and Procedures Manual and the following requirements. A. In order to minimize traffic conflicts and provide for efficient traffic signalization, intersections involving curb return driveways and streets, whether public or private, shall be directly opposed, unless a Traffic Impact Study indicates that an offset intersection benefits public safety to a greater degree. Response: Preliminary communications with the city and Kittleson and Associates indicate that the drive aisle to the south is considered aligned with adjacent commercial drive aisles perthis requirement. B. Streets shall be laid out so as to intersect as nearly as possible at right angles. The angle of intersection between 2 intersecting streets shall be at least 80 degrees. At intersections, each local street shall be straight or have a radius greater than 400 feet for a distance of 100 feet from each intersection. At intersections, each collector or arterial street shall be straight or have a radius greater than 600 feet for a distance of 100 feet from each intersection. Response: New drive aisles and southern and western intersections are provided at right angles throughout the project site per this requirement, per this requirement. 4.2-130 Vision Clearance Area A. All lots or parcels must maintain a Vision Clearance Area to provide adequate sight distance for approaching traffic. Vision clearance areas must be shown on Site Plans for applicable land use applications. Response: Vision clearance areas are shown on the site plan included with this application as Sheet C3.0 in Appendix 4. B. No screens, plantings, or other physical obstructions are permitted between 2Yz and 8 feet above the established height of the curb in the Vision Clearance Area. Response: All structures and public facilities have been designed in accordance with the appropriate City codes to meet this standard. Plantings include trees that will reach mature heights between 30-50 feet. The applicant anticipates shrubs will be maintained to a height less than two and one-half feet from the curb to keep clear vision areas free of visual obstacles. A landscape plan and supplemental information sheets are included with this application as Sheets L1.0 — L1.2 of Appendix 4. 4013WL. Page 18 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 C. The Vision Clearance Area must be in the shape of a triangle. Two sides of the triangle must be property lines or a property line and edge of driveway for a distance specified in this Subsection. Where the property lines or driveway edge have rounded corners, they are measured by extending them in a straight line to a point of intersection. The third side of the triangle is a line across the corner of the lot or parcel joining the non -intersecting ends of the other 2 sides. The following measurements establish the Vision Clearance Area: Table 4.2-5 Response: Vision clearance areas are shown on the site plan included with this application as Sheet C3.0 in Appendix 4. As illustrated, the areas exceed ten feet from all approaches, as measured from the rounded corners of the driveway edge in a straight line to a point of intersection. 4.2-135 Sidewalks A. Sidewalks and planter strips abutting public streets shall be located wholly within the public street right-of-way unless otherwise approved by the Director. Response: Existing sidewalks and planter strips are provided on Gateway Street and Beltline. The applicant does not anticipate that new sidewalks and planter strips along street frontages will be required for the redevelopment of the project site. 4.2-140 Street Trees Street trees are those trees required within the public right-of-way. The primary purpose of street trees is to create a streetscape that benefits from the aesthetic and environmental qualities of an extensive tree canopy along the public street system. Street trees are attractive amenities that improve the appearance of the community, provide shade and visual interest, and enhance the pedestrian environment. Street trees also improve air quality, reduce stormwater runoff, and moderate the micro -climate impacts of heat absorbed by paved surfaces. Street trees may be located within a planter strip or within individual tree wells on a sidewalk, round -about, or median. EXCEPTION: In order to meet street tree requirements where there is no planter strip and street trees cannot be planted within the public right-of-way, trees shall be planted in the required front yard or street side yard setback of private property as specified in the applicable zoning district. 40E3 WL Page 19 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Response: No modifications to the existing frontages on Beltline or Gateway Street are proposed. As such, the applicant anticipates existing street treeswill be preserved consistent with this provision. 4.2-145 Lighting Standards Lighting design and placement for streets, paths, and accessways must conform to the following design standards and the Development 8r Public Works Standard Construction Specifications: A. Lighting must be included with all new developments or redevelopment. Existing lighting must be upgraded to current standards with all new developments or redevelopment. The developer is responsible for lighting material and installation costs. Response: New lighting will be provided forthe Chick-fil-A building and internal parking areas, consistent with this provision. B. Upon approval by the Director, a developer may install decorative lights, as may be permitted in this section and the Development & Public Works Standard Construction Specifications. Response: The applicant does not anticipate decorative lighting forthe project site. Therefore, this provision does not apply. C. Design Standards. 1. Lighting must comply with Illuminating Engineering Society, American National Standards Practice for Roadway Lighting — RP -8- 14 and applicable National Electrical Safety Code (NESC) and National Electrical Code (NEC) standards. Response: All proposed lighting is designed to comply with the Illuminating Engineering Society, American National Standards Practice for Roadway Lighting — RP -8-14, and applicable National Electrical Safety Code (NESC) and National Electrical Code (NEC) standards. A photometric plan is included with this application as Appendix 6 to demonstrate consistency with this provision. 2. Intersections must be illuminated to a level equal to the sum of the average required illuminance of the 2 intersecting streets. Response: The applicant is proposing two new drive aisles, one each at the west and south from adjacent parcels. The location of driveway intersections and illumination levels are shown on the photometric plan, included with this application as Appendix 6. 3. Mid -block crosswalks that are approved by the City Traffic Engineer must have 2 times the illumination required for the street. 400WL. Page 20 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Response: No mid block crosswalks are proposed for this project site. Therefore, this provision does not apply. 4. Decorative poles with City -approved LED fixtures and lighting controls must be used on all streets within the Nodal Development Overlay District and where any refinement plan or plan district requires decorative lighting. Decorative poles may be used on streets, paths, and accessways in any other zone at the option of the developer as approved by the Director. Response: The project site is not located within the Nodal Development Overlay District. Therefore, this provision does not apply. 5. City -approved LED fixtures and lighting controls must be used when lighting is required along multi -use paths and accessways. Response: No multi -use paths or accessways are proposed with this application. Therefore, this provision does not apply. 6. Roadway style poles and "cobra head" fixtures with City -approved LED fixtures and lighting controls must be used along streets in all other locations. Response: No modifications to street frontage lighting is proposed with this application. All existing exterior building and parking lot lighting will be shielded and directed inwards towards the proposed development area. The lighting shall not reflect on or cast a glare on adjacent properties and will likely use "cobra head" fixtures for all parking lot light poles. When roadway style poles are used on arterial and collector streets in any zone other than residential, they must be steel or aluminum. When roadway style poles are used on local and collector streets in residential zones, they must be fiberglass, steel, or aluminum. Response: No modifications to street frontage lighting is proposed with this application. Therefore this provision does not apply. 8. Where lot frontages are 80 feet or less, poles must be located at property lines unless approved by the Director. Response: Lot frontages on the project site exceed 80 feet. Therefore this provision does not apply. 9. The weak point illumination must not be less than 0.1 -foot candles. Response: The weak point illumination exceeds 0.1 -footcandle, as demonstrated on the photometric plan included with this application as Appendix 6. 4013WL. Page 21 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 10. Roadway style poles set behind sidewalks must have 8 -foot arm length. Roadway style poles set between curb and sidewalk or where no sidewalk exists must have 6 -foot arm length. Response: No new walkways or multi -use paths are proposed with this project and as such, lighting or roadway -style poles along said paths are not proposed. Therefore, this provision does not apply. 11. Pole handholes must be used instead of junction boxes where feasible. Junction boxes for street lighting must only be utilized for street crossings or where necessary to comply with electrical code standards cited above. Response: Where applicable, the applicant anticipates pole handholes will be used for all light poles in place of junction boxes, consistent with this provision. 12. Pole Height. Lights on local streets with a curb -to -curb width of less than 28 feet must have a 20 -foot fixture mounting height. Response: Light pole location and height are unknown at this time. However, light poles on local streets will be designed to have a 20 -foot fixture -mounted height, per this requirement. Lighting on local streets must be installed on the same side of the street and on the side of the street first constructed, except where necessary to be consistent with the existing lighting design and placement. Response: No new local street lights are proposed with this project. Light poles must not be placed on the outside of curves with less than a 1,000 -foot radius. Response: Light pole location and height are unknown at this time. However, no light poles are proposed on the outside of curves with less than a 1,000 -foot radius, per this requirement. 4.2-150 Multi -Use Paths A. Development abutting an existing or proposed multi -use path identified in the Springfield Transportation System Plan (including the Conceptual Street Map), City -adopted bicycle and pedestrian plan, or the adopted Willamalane Park and Recreation District Comprehensive Plan must include provisions for the extension of the multi -use path through the development area by the dedication of public easements or rights-of-way. The developer bears the cost of multi -use path improvements. 'lleo0 WL Page 22 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Response: The project site is not adjacent to an existing or proposed multi -use path as identified in Figure 12 ofthe City's Transportation System Plan —Conceptual Street Map. Therefore, this provision does not apply. 4.2-120 Accessways A. Accesswsys allow pedestrians and bicyclists convenient linkages to adjacent streets, residential areas, neighborhood activity centers, industrial or commercial centers, transit facilities, parks, schools, open space, or trails and paths where no public street access exists. Accesswsys may also be used as a secondary emergency access. Accessways must be dedicated as public right-of-way during the development review process. EXCEPTION: When site constraints preclude the ability to dedicate right-of- way without impacting setback requirements or other development standards, the Director may authorize dedication of a public easement or may otherwise modify the standards in this Section. Response: Existing pedestrian accessways are provided on Beltline and Gateway Street. Therefore no accessways are proposed for this project. 4.3-100 Infrastructure Standards — Utilities 4.3-105 Sanitary Sewers A. Sanitary sewers shall be installed to serve each new development within the city limits and to connect developments to existing mains. Installation of sanitary sewers shall provide sufficient access for maintenance activities and shall comply with the provisions of this Code, with the Public Works Standard Construction Specifications, the City's Engineering Design Standards and Procedures Manual, the Springfield Municipal Code, 1997 and Department of Environmental Quality (DEQ) regulations. Response: Existing sanitary sewer lines are present throughout the project site. The applicant anticipates that the restaurant will connect to the city sewer in the northeastern corner of the project site. A utility plan showing the location of water, sewer, and stormwater lines is included with this application as Sheet C5.0 of Appendix 4. B. The City Engineer shall approve all sanitary sewer plans and proposed systems prior to development approval. Response: The applicant anticipates that review and approval of the utility plan are necessary before development approval, consistent with this provision. C. Proposed sewer systems shall include design consideration of additional development within the area as projected by the Metro Plan. Response: The project site is not adjacent to an expansion area or proposed expanded service pipe as shown in Figure 5.5 of the City Wastewater Master Plan. 4tJ 0 W L Page 23 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 D. Proposed developments shall provide dedication and improvements indicated in an adopted Capital Improvements Program or Public Facilities Plan. The developer shall pay a proportional share of the cost according to adopted City Council policy. Response: No wastewater projects are identified adjacent to the project site according to Table 6.1 of the City's Wastewater Master Plan. 4.3-110 Stormwater Management A. Stormwater Management Regulations. By implementing the policies set forth in the currently approved Stormwater Management Plan, provide for the effective management of stormwater and drainage from the City into the groundwater and watercourses within the City and its urbanizing area; minimize demand on the City's stormwater management system, and alleviate future costs of treating the discharge; promote water quality; preserve groundwaterand the vegetation and rivers it supports; reduce peak storm flows; minimize public and private losses due to flood conditions; and minimize stormwater discharge impacts on water quality and quantity and stream flow patterns, including peak and base flows in intermittent and perennial streams, within the McKenzie River and Willamette River watersheds. Response: A preliminary stormwater plan is included with this application as Sheet C4.0 of Appendix 4. A drainage report is included with this application in Appendix 10. The drainage report concludes that the project site will provide water quality and quantity mitigation through proposed stormwater planters and rain gardens that are sized for a 1.4 -inch over 24-hour stormwater event. A downstream analysis has been performed and found that development did not create capacity issues in the existing system. B. The Approval Authority shall grant development approval only where adequate public and/or private stormwater management systems provisions have been made as determined by the Public Works Director, consistent with the policies set forth in the Stormwater Management Plan and the Engineering Design Standards and Procedures Manual. The stormwater management system shall be separated from any sanitary sewer system. Surface water drainage patterns shall be addressed on every Preliminary Site Plan, or Tentative Partition or Subdivision Plan. Response: The applicant anticipates the proposed stormwater management system complies with the policies set forth in the Stormwater Management Plan and the Engineering Design Standards and Procedures Manual as required by this section. C. A stormwater management system shall accommodate potential run-off from its entire upstream drainage area, whether inside or outside of the development. The Public Works Director shall determine the necessary size of the facility, based on adopted Public Facility Plans and Stormwater 400 0 W L Page 24 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Facility Master Plans. The developer shall pay a proportional share of the cost according to adopted City Council policy. Response: The proposed stormwater system design is shown on Sheet C4.0 and described in the drainage report included with this application as Appendix 10. Because the project will be redeveloping an existing site that has more impervious coverage than what is proposed, the resultant peak flows entering the public system will be smaller than existing. D. Runoff from development shall be directed to an approved stormwater management system with sufficient capacity to accept the discharge. Where the Public Works Director determines that the additional run-off resulting from the development will overload an existing stormwater management system, the Approval Authority shall withhold Development Approval until provisions, consistent with the Engineering Design Standards and Procedures Manual, have been made to correct or mitigate this condition. Response: A preliminary stormwater plan is included with this application as Sheet C4.0 of Appendix 4. A drainage report is included with this application in Appendix 10. The drainage report concludes that the project site will provide water quality and quantity mitigation through proposed stormwater planters and rain gardens that are sized for a 1.4 -inch over 24-hour stormwater event. A downstream analysis has been performed and found that development did not create capacity issues in the existing system. E. Any development with a stormwater threshold management requirement of 1,000 square feet of impervious surface area shall be required to employ stormwater management practices consistent with the Springfield Engineering Design Standards and Procedures Manual, which minimize the amount and rate of surface water run-off into receiving streams. The following stormwater management practices may be required in order to relieve demand on the City's piped drainage system, alleviate future costs of treating the piped discharge, promotewater quality, preserve groundwater and the vegetation and rivers it supports, and reduce peak storm flows: 1. Temporary ponding of water; 2. Permanent storage basins; 3. Minimizing impervious surfaces; 4. Emphasizing natural water percolation and natural drainageways; 5. Preventing water flowing from the street in an uncontrolled fashion; 6. Stabilizing natural drainageways as necessary below drainage and culvert discharge points for a distance sufficient to convey the discharge without channel erosion, as perm ittedlal lowed by City, State and Federal regulations; 400WL Page 25 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 7. On-site filtration or skimming of run-off, that will enter natural drainageways to maintain water quality; 8. On-site constructed wetlands; and 9. The riparian area boundary, as specified in Subsection 4.3-115A, may be utilized to meet City on-site stormwater management requirements for flood control and water quality treatment provided the design is complementary to and supportive of the primary objective of a properly functioning riparian habitat condition. Where the riparian boundary is not of sufficient size to meet these on-site requirements, the additional area needed shall be located contiguous to the riparian boundary to form a consolidated stormwater feature for operational and maintenance efficiencies and that is designed to be compatible with and complementary to the riparian area boundary. Response: Total impervious cover exceeds 1,000 square feet and therefore, will implement several of the stormwater management practices listed above, including stormwater planters and rain gardens that are sized for a 1.4 inch over 24-hour stormwater event. It's of note that the redevelopment of the project site will decrease the area of impervious cover from 3.651 acres (159,037 square feet) to 3.648 acres (158,907 square feet). F. Identification of Water Quality Limited Watercourses. The Director shall maintain a Water Quality Limited Watercourses (WQLW) Map on file in the Development Services Department, which designates certain watercourses and their direct tributaries within the City and its urbanizing area. The WQLW Map shall contain watercourses recommended by the Public Works Director. Any revision to the WQLW Map shall be approved by the City Council as an amendment to this Code. Those watercourses and their direct tributaries included on the WQLW Map have been found to warrant protective measures in support of the City's response to State and federal regulations regarding surface and subsurface discharging stormwater management systems by satisfying the following criteria: 1. Water Quality Limited Watercourses(WQLW): Waters of the State that meet one or more of the following criteria: a. Watercourse reaches, lying within the City and its urbanizing area, that are included by the State of Oregon Department of Environmental Quality (ODEQ) on its most recently adopted "303(d)" List of Impaired and Threatened Waterbodies. b. Watercourse reaches, lying within the City and its urbanizing area, with significant water quality impairment identified by water quality monitoring and sampling done in accordance 'lleo0 WL Page 26 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 with approved quality assurance/quality control (QA/QC) protocols. Response: The project site is not adjacent to a watercourse as identified in the City's Natural Resource Study Report (2011). The applicant's proposed use is the same as the existing use on the project site. Consistency with water quality assurance/quality control protocols is outlined in further detail in findings for the Drinking Water Protection Overlay District. Therefore, the applicant anticipates this provision and all Subsections do not apply. 4.3-117 Natural Resource Protection Areas Response: No locally significant wetland and riparian areas, flood hazard areas, or Goal 5 resources are identified on the project site. The site is located within the Drinking Water Protection Overlay. The project's consistency with the Drinking Water Protection Overlay District is discussed earlier in this narrative. Therefore, this section does not apply. 4.3-120 Utility Provider Coordination A. All utility providers shall be responsible for coordinating utility installations with the City and the developer through the Development Review Committee or by separate written correspondence. B. The developer shall be responsible for the design, installation and cost of utility lines and facilities to the satisfaction of the utility provider. Response: The applicant anticipates existing wastewater, stormwater, and franchise lines are available adjacent to the proposed restaurant. There is no existing water line to serve the future restaurant location and as such, the applicant plans to extend water from the eastern property line up to the restaurant building from an existing tap adjacent to Pad A and Gateway Street. Plans indicate the new waterline and junction box will be included in a 10 -foot -wide dedicated easement for SUB. The location and specifications surrounding the new domestic waterline are outlined in the marked site plan from SUB, included with this application as Appendix 3. These comments were included in the design and shown on the utility plan included as Sheet C5.0 of Appendix 4. 4.3-125 Underground Placement of Utilities Whenever possible, all utility lines shall be placed underground. However, overhead and above -ground facilities are permitted for the following: Response: All existing and proposed utility lines shown on Sheet C5.0 of Appendix 4 that are contiguous to the project site, including those required for electricity, communication, water, and stormwater will be placed underground as required by this provision. to 13 W IL Page 27 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #84967 4.3-130 Water Service and Fire Protection A. Each development area shall be provided with a water system having sufficiently sized mains and lesser lines to furnish an adequate water supply to the development with sufficient access for maintenance. Response: A new water line will extend from the eastern property line up to the restaurant building from an existing tap adjacent to Pad A and Gateway Street. The proposed line will be sized to provide domestic water service and with adequate pressure for fire suppression purposes. The location of fire hydrants and water lines are shown on Sheet C5.0 and Sheet C5.1 in Appendix 4. B. Fire hydrants and mains shall be installed by the developer as required by the Fire Marshal and the utility provider. Response: The applicant anticipates fire hydrants and mains will be installed as required by the Fire Marshal and utility provider (SUB). As such, the applicant has provided a utility plan (Sheet C5.0) and fire access plan (Sheet C5.1) in Appendix 4 to demonstrate the project's consistency with this provision. 4.3-135 Major Electrical Transmission Lines A. When necessary to increase the capacity of major electrical power transmission lines, utility providers shall provide the increase by use of existing rights-of-way or easements. Response: The applicant anticipates the proposed restaurant use will have similar if not less electrical utility demand compared to the previous uses (formerly Elmer's restaurant and a motel). Therefore, no increase in the capacity of major electrical power transmission lines is anticipated and this provision does not apply. 4.3-140 Public Easements A. Utility Easements. The applicant shall make arrangements with the City and each utility providerforthe dedication of utility easements necessary to fully service the development or land beyond the development area, as necessary. The minimum width for public utility easements adjacent to street rights-of-way shall be 7 feet. The minimum width for all other public utility easements shall also be 7 feet. However, the utility provider or the Public Works Director may require a larger easement for major water mains, major electric power transmission lines, sanitary sewer lines, stormwater management systems or in any other situation to allow maintenance vehicles to set up and perform the required maintenance orto accommodate multiple utility lines. Where feasible, utility easements shall be centered on a lotiparcel line. Response: There is no existing water line to serve the future restaurant location and as such, the applicant plans to extend water from the eastern property line up to the restaurant building from an existing tap adjacent to Pad A and Gateway Street. 40013 W L. Page 28 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #94967 Plans indicate the new waterline and junction box will be included in a 10 -foot -wide dedicated easement for SUB. The location and specifications surrounding the new domestic waterline are outlined in a letter from SUB, included with this application as Appendix 3. These comments were included in the design and shown on the utility plan included as Sheet C5.0 of Appendix 4. 4.4-100 Landscaping, Screening and Fence Standards 4.4-105 Landscaping A. These regulations ensure that new development complies with the landscaping provisions of this Code and any applicable Refinement Plans, Plan Districts, Master Plans, and Conceptual Development Plans; is adequately screened from less intensive development; considers the effects of vegetation on public facilities; retains significant clusters of natural trees and shrubs wherever possible; minimizes run-off; facilitates energy conservation and crime prevention; and improves the appearance of the City to create a desirable place to live and work Response: A landscaping plan is included with this application as Sheet 11.0 of Appendix 4 to illustrate landscaping improvements and consistency with the Gateway Refinement Plan. B. Three types of landscaping may be required: 1. Landscaping standards for private property as specified in this Section and other Sections of this Code. Response: Existing street trees and curbside planter strips along the public right-of-way were both noted as sufficient, with no required landscaping improvements. Therefore, the applicant anticipates private property landscaping requirements, as specified in this code, and the Gateway Refinement Plan will be required. C. Materials and installation costs of planting and irrigation other than what is required by the Minimum Development Standards (Section 5.15-100) shall not be required to exceed 10 percent of the value of the new development, including parking facilities. The Director shall determine the location, quantity and quality of required landscaping as specified in this Code. Response: The applicant anticipates that the cost of planting and irrigation will not exceed 10 percent of the value of the new development, as specified in this provision. D. Unless otherwise specified in this Code, the following areas of a lotiparcel shall be landscaped: 1. All required setback areas and any additional planting areas as specified in the appropriate zoning district. 2. Parking lot planting areas required in this Section. 'lletJ 0 W L. Page 29 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Response: The applicant has prepared and included a landscape plan as Sheet L1.0 of Appendix 4, that identifies perimeter landscaping, interior landscaping, and parking lot planting areas, consistent with this provision. E. At least 65 percent of each required planting area shall be covered with living plant materials within 5 years of the date of installation. The living plant materials shall be distributed throughout the required planting area. The planting acceptable per 1,000 square feet of the required planting area is as follows: Response: The landscape plan is designed such that each required planting will achieve at least 75 percent with living plant materials within three (3) years, consistent with the more stringent standard outlined in the Gateway Refinement Plan. The gross floor area of the proposed restaurant is 4,987 square feet. The landscape plan shows 71 trees, 1,222 shrubs, and 10,365 square feet of ground cover. A landscape plan is included with this application as Sheet L1.0 of Appendix 4. F. Parking lot planting areas shall include 1 canopy tree at least 2 inches in caliper that meets City street tree standards as may be permitted by the City's Engineering Design Standards and Procedures Manual and at least 4 shrubs, 5 -gallon or larger, for each 100 square feet of planting area. Shrubbery that abuts public right-of-way or that is placed in the interior of any parking lot shall generally not exceed 2-1/2 feet in height at maturity. Parking lot planting areas shall include: Parking and driveway setback areas specified in the applicable zoning district; and 5 percent of the interior of a parking lot, exclusive of any required parking setbacks, if 24 or more parking spaces are located between the street side of a building and an arterial or collector street, and are visible from any street. Response: The project site is located in the CC zoning district and is subject to a ten -foot building setback and five-foot parking, driveway, and outdoor storage setback. The landscape plan indicates 18 percent or 5,196 square feet of the interior parking lot is screened from Beltline and Gateway Street, consistent with this provision and the Gateway Refinement Plan. G. All new required planting areas shall be provided with a permanent underground irrigation system unless where planted with native species or plant communities, or as may be exempted by the Director. Response: The applicant anticipates that all new planting areas will be provided with a permanent underground irrigation system. Irrigation system design and plans will be provided following land use approval. 40013 W L Page 30 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 H. Landscaped setbacks abutting required screening on the same property may be exempted by the Director from planting requirements if the area is not visible from any public right-of-way or adjacent property. Response: The applicant anticipates that the project site will be able to provide landscaping within the required property setbacks in the CCzoning districtwhile also complying with the screening requirements for mechanical equipment and trash enclosures. Therefore, no exemption is requested with this application. Planting Installation Standards. 1. The applicant shall provide methods for the protection of existing plant material, which will remain through the construction process. The plants to be saved and the method of protection shall be noted on the Planting Plan. Response: No existing planting material will remain through the construction process. Therefore this provision does not apply. 2. Existing trees to be retained on private property shall not have construction occur within the drip line, unless a landscape architect certifies that affected trees will have at least a 90 percent chance of survival over a 5 -year period. Trees to be saved shall be kept free from trunk abrasion. Response: No existing trees will be retained on the project site. Therefore, the applicant anticipates a Tree Felling Permit will be required and will be provided following land use approval. 3. The Planting Plan may be required to include specifications for topsoil, including depth and organic matter requirements, to ensure the health and vitality of required planting. Where planting areas have been excavated, the Planting Plan shall provide for the replacement of topsoil. All waste material shall be removed from required planting areas prior to the application of topsoil. Inspection may be made by the Director prior to planting to verify proper rough grade and installation of irrigation systems. b. Plant materials and soil preparation may be inspected prior to or in conjunction with the occupancy inspection to ensure that placement, quantity, size, and variety conform to the approved Planting Plan and the requirements of this Section. Nursery tags identifying variety and species shall remain on plant specimens until the Final Building Inspection by the Building Official or the issuance of a Certificate of Occupancy. ltJO WL Page 31 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Response: The applicant understands that inspection and verification of soil depth and organic matter will occur before the proposed plantings. 4.4-110 Screening A. Unless otherwise specified in this Code, screening shall be required: 2. For outdoor mechanical devices and minor and major public facilities; 4. For trash receptacles; Response: The project site does not abut a residential or different zoned area, and therefore is not subject to screening between uses. Outdoor mechanical devices and minor and major facilities will be located on the roof and screened behind the building fagade. The location and screening method for mechanical equipment can be seen on the architectural plan, included with this application as Appendix 5. Trash and recycling receptacles will be located within an enclosure, designed to have matching architectural features to the proposed restaurant including a combination of dark steel and white stucco siding. B. Screening shall be vegetative, earthen and/or structural and be designed to minimize visual and audible incompatible uses from adjacent properties. Unless specified elsewhere in this Subsection, screening shall be continuous to at least 6 feet above ground level. The following standards shall apply: 1. Vegetative Screening. Evergreen shrubs shall be planted to form a continuous hedge. When immediate screening is necessary, a sight - obscuring fence shall be installed in place of, or in conjunction with the shrubs. The 6 -foot height standard specified in Subsection B., above shall occur within 4 years of planting. 3. Structural Screening. Afence or masonry wall shall be constructed to provide a uniform sightobscuring screen. EXCEPTIONS: Any refuse container or disposal area which would otherwise be visible from a public street, customer or resident parking area, any public facility, adjacent property, or any residential area, shall be screened from view as specified in Subsections 1. and 3., above. All refuse materials shall be contained within the screened area. See also Section 3.2-240D.3.b. for multifamily design standards. This standard does not apply to single and 2 -family dwellings. Response: The refuse and recycling areas are located within an enclosed masonry wall, as shown on the architectural plan included in Appendix 5. 4013WL. Page 32 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 4.4-115 Fences Fences shall not exceed the height standards in Table 4.4-1 and shall be located as follows: A. General 1. In any zoning, overlay or plan district not specifically listed in Table 4.4-1, fence standards shall be determined based upon the use, for example a commercial use in the Mixed Use Commercial District shall comply with fence standards for the commercial districts in Table 4.4-1. Response: No fences are proposed with this application. Therefore this provision does not apply. 4.5-100 On -Site Lighting Standards 4.5-110 Illumination and Height A. Standards for Installation and Operation of Outdoor Lighting. Except as exempt by subsection (C) of SDC 4.5.105 above, new outdoor lighting fixtures installed after July 1, 2022, are subject to the standards below. No provision of this section is intended to preempt Springfield Municipal Code 8.200 et seq., Signs, or applicable State codes. (1) All outdoor lighting fixtures subject to this section must be designed as a full cut-off fixture or have a shielding method to direct light emissions down onto the site and not shine direct illumination or glare onto adjacent properties. (2) All lighting for roadways, roadway signs, intersections, and pedestrian ways must be designed or have an opaque shielding method to direct light emissions downward and below the horizontal plane of the fixture in the permanently installed position. (3) The use of laser source light or any similar high intensity light for outdoor advertising or entertainment is prohibited. (6) Businesses and institutions with outdoor lighting, such as parking lot lights, building lights, landscaping lights, and other similar exterior lighting features, are encouraged to extinguish such lights at the end of the working day, except for lights necessary for personal and building safety. Response: Lighting will be provided in accordance with these standards. As shown on the photometric plan included with this application as Appendix 6, lighting will be provided throughout the project site at lighting levels consistent with the City's on- site lighting standards. Lighting will be provided throughout parking areas, landscaped areas, and all building entrances. Any proposed lighting will be 40013 W L Page 33 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 downward facing and shielded to avoid significant light trespass. Lighting provided at roadway signs and private driveway intersections will be designed to be downward facing, below the horizontal plane of the fixture in the permanently installed position. B. On-site lighting shall be the minimum illumination necessary for a given application including parking areas and vehicle sales areas. All exterior light fixtures shall be shielded or recessed so that direct glare and reflection are contained within the boundaries of the property and directed downward and away from abutting properties; public rightsof-way; and riparian, wetlands, and other protected areas identified in this Code on the same property. Response: Lighting will be provided in accordance with these standards. As shown on the photometric plan included with this application as Appendix 6, lighting will be provided throughout the project site at lighting levels consistent with the City's on- site lighting standards. Lighting will be provided throughout parking areas, landscaped areas, and all building entrances. Any proposed lighting will be downward facing and shielded to avoid significant light trespass. Lighting provided at roadway signs and at private driveway intersections will be designed to be downward facing, below the horizontal plane of the fixture in the permanently installed position. C. Height. 1. The height of a free standing exterior light fixture shall not exceed 25 feet or the height of the principal permitted structure, whichever is less. In this case, height is measured as the vertical distance between the paved surface and the bottom of the light fixture. Response: All proposed light poles will not exceed the 25 -foot maximum height requirement per this provision. 4.6-100 Motor Vehicle Parking, Loading and Bicycle Parking Standards 4.6-110 Motor Vehicle Parking — General A. Off-street parking spaces shall be provided, consistent with requirements in Section 4.6-125, Table 4.6-2, unless excepted as allowed herein, for: 1. All new construction and expansion of multiple family residential, commercial, industrial and public and semi-public uses. If an existing development is expanded, new parking spaces shall be provided in proportion to the increase only. 2. Changes in use or the use category of an existing building or structure. Response: The applicant anticipates new parking spaces are required due to the change in use from the existing buildings (formerly Elmer's and a motel) to the new restaurant 400 13 W L Page 34 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 and future Pad Site A and future Pad Site B. Parking totals and design findings are provided for the restaurant only. Future Pad Site parking totals will be provided when developed in the future. B. If parking has been provided to serve an existing use, the number of parking spaces cannot be reduced if the result would be fewer spaces than required by this Section, except as parking reductions are allowed below and under Special Provisions to Table 4.6-2. Response: The applicant has reconfigured the parking lot from the existing use and existing parking in an effort to provide ample room for new development (utilities, drive aisles, landscape improvements, and future pad sites). Parking counts will not result in fewer parking spaces than those provided under the existing approval. C. Parking reductions under Sections 4.6-110.1-1 through L and Special Provisions to Table 4.6-2 shall not reduce the number of ADA parking spaces required in accordance with the minimum parking in Table 4.6-2 or under Section 4.6-110.M. Response: No parking reductions are requested with this application. Two ADA parking spaces are proposed, consistentwith Table 4.6-2 and Section 4.6-110.M. E. Required parking spaces shall be available for the parking of passenger vehicles of residents, customers, patrons, visitors, and employees only, and shall not be used for outdoor displays, storage of vehicles, equipment, or materials. Parking for company motor vehicles that remain on the premises overnight, or enclosures designed for the temporary collection of shopping carts, must be provided in addition to the number of parking spaces required by this Section. Response: All required parking totals are provided for passenger vehicles of customers, patrons, visitors, and employees. No outdoor displays, storage of vehicles, equipment, or materials is proposed with this application. E. Unless joint use of parking facilities is requested as may be permitted in Subsection E. below, the total requirement for off-street parking spaces is the sum of the requirements for all uses. If the total number of required parking spaces results in a fraction, the fraction shall be rounded up to the next whole number. Off-street parking facilities for one use shall not be considered as providing parking facilities for any other use, unless as may be permitted in Subsection F., below. Response: Parking totals proposed with this application are for the restaurant building only. Additional parking stalls to serve future pad sites A and B are shown on the site plan but not requested as a part of the application and will be designed and included in future submittals. G. When on -street parking is available directly abutting the property and there are no adopted plans to remove the on -street parking, parking spaces in a 400 0 W L Page 35 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 public right-of-way directly abutting the development area may be counted as fulfilling a part of the parking requirements for development as follows: For each 18 feet of available on -street parking, there will be 1/2 space credit toward the required amount of off-street parking spaces. The developer is responsible for marking any on -street spaces. Response: There are no on -street parking areas directly abutting the project site. Therefore, this provision does not apply. H. Motor Vehicle Parking Space Reduction Credit for Additional Bicycle Parking. Additional bicycle parking beyond the minimum amount required in Table 4.6-3 that complies with the bike parking standards in Sections 4.6-145 and 4.6-150 may substitute up to 20% of off-street motor vehicle parking otherwise required in Table 4.6-2. For every 2 non -required bicycle parking spaces that meet the short -or long-term bicycle parking standards specified in Table 4.63, the motor vehicle parking requirement is reduced by 1 space. When existing parking converted to bicycle parking under this subsection results in surplus motor vehicle parking spaces, the surplus parking may be converted to another use in conformance withthe requirements of this Code. Response: No reduction in parking totals is requested with this application. Therefore, this provision does not apply. Motor Vehicle Parking Space Reduction Credit for Frequent Transit Corridors—Abutting Sites. Development sites abutting an existing or proposed Frequent Transit Corridor may request a reduction of up to 15% from minimum off-street motor vehicle parking required in Table 4.6-2. Response: No reduction in parking totals is requested with this application. Therefore, this provision does not apply. J. Motor Vehicle Parking Space Reduction Credit for Frequent Transit Corridors—Nearby Sites. Development sites not abutting but within 1/4 -mile of an existing or proposed Frequent Transit Corridor may request a reduction of up to 10% from minimum off-street motor vehicle parking required in Table 4.6-2. Response: No reduction in parking totals is requested with this application. Therefore, this provision does not apply. K. Reduction Credit for ADA Improvements for Frequent Transit Corridors. Development sites abutting or within 1/4 mile of an existing or proposed Frequent Transit Corridor may receive a reduction of up to 10% from the minimum off-street motorvehicle parking required in Table4.6-2 in exchange for contribution to the City forADA improvements in the public right-of-way. The required contribution will be equal to the Base Curb Ramp Fee multiplied by each set of 4 parking spaces to be reduced, rounded up to the next whole number (e.g. one Base Curb Ramp Fee for 1 to 4 parking spaces reduced, double the Base Curb Ramp Fee for 5 to 8 parking spaces reduced, etc.). The 400 0 W L Page 36 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Base Curb Ramp Fee must be set by Council resolution and must be approximately the cost of constructing one ADA -compliant curb ramp. Nothing in this subsection waives or alters any requirement for a developer to construct or provide on-site or off-site ADA improvements. Response: No reduction in parking totals is requested with this application. Therefore, this provision does not apply. N. Right Size Parking Alternative -Maximum. The Approval Authority may authorize an alternative parking standard that is more than 125% of the minimum off-street parking standard in Section 4.6-125. The alternative parking standard must be the peak parking demand identified by a parking generation study conducted according to the ITE Manual of Transportation Engineering Studies and prepared by a licensed engineer. (6412) Response: The project site is required to provide a minimum of 50 parking stalls and is limited to a maximum of 63 parking stalls. Atotal of 83 parking stalls is requested to serve the proposed restaurant, which exceeds the maximum allowed amount. In support of this request, a parking assessment memorandum from Kittleson and Associates is included with this application as Appendix 8. 4.6-115 Motor Vehicle Parking - Parking Lot Design All off-street parking areas shall comply with the following dimensional standards: Table 4.6-1 Dimensional Feature (all dimensions in feet) Diagram Stall width, standard Parking Angle 0 45 J � 0 90 A I 9.0 9.0 I 9.0 I 9.01 Stallwidth, compact I A 1 30 801 801 8 0 Stall length. standard I1 24.0 18.0 18.0 18.0 Stall length. compact I1 22.0 16.0 16.0 16.0 Aisle width between stall Imes I 1 12.0 12.0 16.0 24.0 Bumper overhang(typicah IDI 0.0 1.5 1.6 2.0 Cross -aisle, I-way I1 16.0 16.0 16.0 1 16.0 Cross -aisle, 2 -way I1 24.0 24.0 24.0 24.0 Response: Parking stall locations and dimensions are shown on the site plan included with this application as Sheet C2.0 of Appendix 4. 41to0 WL Page 37 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #84967 4.6-120 Motor Vehicle Parking — Parking Lot Improvements All parking areas shall conform to the setback, vision clearance, planting and screening provisions of this Code and shall be completed prior to occupancy. Required parking spaces shall be improved as follows: A. All parking lots, bays, and spaces must have a durable, dust -free surfacing of Asphaltic concrete, Portland cement concrete or other materials as approved by the City Engineer. Permeable pavement meeting standards in the City's Engineering Design Standards and Procedures Manual may be allowed by the City Engineer for parking areas and driveways. Parking lot surfacing shall not encroach upon the public right-of-way. Response: The existing parking area will be resurfaced with new Asphalt concrete, as approved by the City Engineer. B. Adequate drainage improvements shall be provided to manage all onsite run-off. Provisions shall be madeforthe on-site collection of drainagewaters to eliminate sheet flow onto sidewalks, public rights-of-way, and abutting private property. All drainage systems shall be approved by the City Engineer. Response: Adequate drainage improvements are proposed to manage surface water run-off from the site, as shown on the storm plan included in Sheet C4.0 of Appendix 4. C. All parking spaces fronting a sidewalk, alley, street, landscaped area or structure shall be provided with a secured wheel bumper or linear curb not less than 6 inches in height to be set back from the front of the stall a minimum of 2 feet to allowfor vehicle encroachment. Wheel bumpers shall be a minimum of 6 feet in length. Curbs shall be constructed in conformance with the Standard Construction Specifications. EXCEPTION: As an option, the sidewalk or landscaped area may be widened 2 feet beyond the minimum dimension required to allow for vehicle encroachment. A curb not less than 6 inches in height shall protect the widened sidewalks and planter areas. Response: The site has been designed such that linear curb will be provided in front of parking spaces abutting the restaurant, drive-through lanes, and landscaped areas. D. Backing into the public right-of-way, other than alleys is prohibited. EXCEPTION: Parking areas of less than 4 spaces on a residentially zoned lotiparcel may back into the public right-of-way. Response: On-site traffic circulation allows for efficient navigation without backing into the public right-of-way. to 13WL. Page 38 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #94967 E. All spaces shall be permanently and clearly marked unless the Director determines that the spaces should not be marked for safety considerations. Old striping shall not be visible after being replaced by new striping. Response: All parking stalls with be permanently and clearly marked, consistent with this provision. No existing striping will be visible after being replaced by the new asphalt paving and new striping. F. Not more than 30% of the total parking spaces in a parking lot may be designated for compact cars, unless a greater percentage is authorized by the Director based on substantial evidence that greater than 30% of the total parking spaces is appropriate for the use. These spaces shall be signed andlor the space painted with the words "Compact Car Only." Response: No compact spaces are proposed with this application. Therefore, this provision does not apply. G. Parking Spaces for People with Disabilities. 1. Parking spaces for people with disabilities and accessible passenger loading zones that serve a particular building shall be located as close as possible to a building entrance. Response: The project site provides two accessible parking stalls with a shared passenger loading zone. Both spaces are located adjacent to the restaurant entrance. 2. The number and dimensions of parking spaces for people with disabilities shall be as specified in Section 1106 of the Oregon Structural Specialty Code. Response: The project site provides 83 parking stalls and therefore, is required to provide a minimum of two accessible parking stalls and one van accessible space according to Oregon Structural Specialty Code. The location of accessible parking stalls is shown on the site plan, included as Sheet C2.0 of Appendix 4. 4.6-125 Motor Vehicle Parking — Parking Space Requirements A. Table 4.6-2 establishes minimum off-street parking standards according to use, which apply to that use in any zoning district. B. The minimum parking standard for any use not specified in Table 4.6-2 is the average peak period parking demand identified for that use in the current version of the ITE Parking Manual, forthe day(s) of the weekwith the highest parking demand. C. The maximum off-street parking standard for any use that is not a residential use is 125% of the minimum off-street parking standard. There is no maximum off-street parking standard for residential uses. Ileo0 WL Page 39 Type II Site Plan Review (Pre -Submittal) I Chick-fil-A #04967 D. Parking standards established in Table 4.6-2 may be modified as provided in Section 4.6-110. Table 4.6-2 Response: The proposed restaurant building is 4,987 square feet of gross floor area and requires a minimum of 50 parking stalls and not more than 63 parking stalls (ie - 125% of the minimum number of parking stalls). The project site includes 83 parking stalls and therefore exceeds the maximum parking requirements. In support of this request, a parking assessment memorandum from Kittleson and Associates is included with this application as Appendix 8. Special Provisions. B. Commercial Districts. 1. Parking lots in the Neighborhood Commercial (NC) District shall be designed so that every seventh space is developed as a landscaped separator between spaces. NC developments that require more than 25 parking spaces shall locate half of all the required spaces over 25 behind proposed buildings. Response: The project site is not located in the Neighborhood Commercial (NC) District. Therefore, this provision does not apply. too WL Page 40 Minimum Panama standard Zu Nssmmual uses Single mmily (attached and Oadoned) and auplev 1 space Wr each MVelnng when paved on street Poll Is available directly ab rt ng dwellings the proper and Mere are no adopted plans to remove the On street parking. 2 spau5 for each dwelMg when no paved on street parking Is available directly abuding the properly or when the Skbting on -street parking Is planned to be removed as pan UI an NoflW also Manuel dealings, l space ror each dwelling One GIWs out, Pus . 025 space for each bedroom orlove Hing unit plus l per bull hme employee W the busiest shin Sparking and morning houses (see SOC 67-215) 05 Man additional parking space for each boardlog mom In addition to any puling fora pnmary use. Commemialllndustdal uses CMld care center l space Snatch 35d square(eetofgrossarea, plus l dropoRspacs foretell 700 squarebeet,ff, sdoorarea. MMait.00 or bed and breakfast tadlNes l spas plus i space nor each guest mom. Eann and drintrat establishments is ace for each 1 Ws uam leet or aress Mor area. Retail trade and seMces(Induding shopping centers) l space for every 300 square feet or gross floor area. Manufacture and assembly. and other primary l space ror can l No square feet or gross floor area industrial uses. Includes warehousing, warehouse commereWl saks(IncludNg bulky l space has each 6N square fleet M gross Mor area. ...handle.) Pushed ark InsrXYtlonal was Educationist htllniss 2spaceloreableastimmin plus l Wasch 100squarebeet Urine largest Public assembly area. Public chatty holly None, unlessuunryvUltlxwill be parned ovemlght Recreational MdN s, and reYglous, social and public 1 spat or each IN square beet OF door area In Me prhnary aasembry area and 1 Instaboons for Sued 200 square feet Orgross Poor area for Me remainder of ale building. TMnspoftM facHPks tspace tor each 300 square feel M gross Mor area not Including vehicle storage aRu. Response: The proposed restaurant building is 4,987 square feet of gross floor area and requires a minimum of 50 parking stalls and not more than 63 parking stalls (ie - 125% of the minimum number of parking stalls). The project site includes 83 parking stalls and therefore exceeds the maximum parking requirements. In support of this request, a parking assessment memorandum from Kittleson and Associates is included with this application as Appendix 8. Special Provisions. B. Commercial Districts. 1. Parking lots in the Neighborhood Commercial (NC) District shall be designed so that every seventh space is developed as a landscaped separator between spaces. NC developments that require more than 25 parking spaces shall locate half of all the required spaces over 25 behind proposed buildings. Response: The project site is not located in the Neighborhood Commercial (NC) District. Therefore, this provision does not apply. too WL Page 40 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 2. Parking lots shall be used exclusively for the parking of vehicles. EXCEPTION: Parking spaces in excess of the number required by this Code may be used for temporary sales or display of merchandise where the activity does not create a hazard for automobile or pedestrian traffic orwhere otherwise allowed under this Code or the Springfield Municipal Code. Response: The project site's parking lot will be used exclusively for the parking of vehicles. 3. A minimum of 4 off-street parking spaces shall be required for all sites in commercial zoning districts that require parking, unless reduced under Section 4.6-110.M. Response: The parking totals provided for the proposed restaurant exceed the minimum off- street parking requirements established by this section. Adequate parking counts are provided, consistent with Table 4.6-2. 4.6-135 Loading Areas — Facility Design and Improvements A. All necessary loading areas for commercial and industrial development shall be located off-street and provided in addition to the required parking spaces. Response: As provided under Subsection C, no loading areas are provided based on the minimum size requirements for commercial loading areas. B. Vehicles in the loading area shall not protrude into a public right-of-way or sidewalk. EXCEPTION: When no other reasonable alternative exists, loading areas shall be located so that vehicles are not required to back or maneuver in the public right-of-way or internal travel aisles. Response: As provided below, no loading areas are provided based on the minimum size requirements for commercial loading areas. C. The minimum sizes required for commercial and industrial loading areas are as follows: 1. Two hundred fifty square feet for buildings of 5,000 to 20,000 square feet of gross floor area. Response: The restaurant building is 4,987 square feet of gross floor space and therefore, is below the 5,000 square foot threshold therefore the project is not required to provide a loading area. 41to0 WL Page 41 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 4.6-145 Bicycle Parking — Facility Design A. Required bicycle parking spaces and facilities must be a powder coated staple or inverted -U rack as shown in Figure 4.6-B. Alternatively, the required bicycle parking spaces must fulfill the criteria for quality bicycle parking, which are as follows: 1. Supports the bicycle frame in a stable position without damage to wheels, frames, or components and provides two points of contact; 2. Allows locking of the frame and one or both wheels with a U -lock; 3. Is securely anchored to the ground or to a structure; 4. Resists cutting, rusting, bending, or deformation, both from natural causes and from human abuse; 5. Powder coated or durable, non -scratching surface; and 6. Works well for a variety of bicycle frame types (e.g., should work for step -through frame as well as diamond frame, children's bicycles as well as adult bicycles, recumbent as well as other styles of adaptive bicycles). Response: Bicycle parking spaces will consist of powder -coated staple style racks that are spaces to work with a variety of bicycle frame types. B. Required bicycle parking spaces and facilities must be constructed and installed in accordance with Section 4.6-150 and Figures 4.6-13 and 4.6-C. Bicycle parking must be provided at ground level unless an elevator with clear bicycle wayfinding signage is easily accessible and directs users to an approved bicycle storage area. Each required bicycle parking space must be accessible without removing another bicycle. Response: Bicycle parking will be provided adjacent to the restaurant building on the ground floor with adequate spacing between bicycles to provide convenient access. C. All required long-term bicycle parking spaces must be sheltered from precipitation and include lighting. Response: The proposed Chick -fl -A restaurantwill be 4,987 square feet. Per Table 4.6.3, the project restaurant is required to provide 1 bicycle parking space per 600 square feet of floor area, or nine bicycle parking spaces, with 25 percent of spaces designated as long-term parking and 75 percent designated as short-term parking. The applicant will provide ten bicycle parking spaces (four long-term, six short- term). Bicycle parking will be located under an awning and well -lit per this provision. 4013WL. Page 42 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 D. Short-term bicycle parking must be sheltered as follows: 1. If 10 or fewer short-term bicycle parking spaces are required, no shelter is required for short-term bicycle parking. Response: Six (or 75 percent) short-term bicycle spaces are provided. Therefore, the applicant does not exceed ten short-term bicycle spaces and is not required to shelter short-term bicycle parking. E. Bicycle parking that accommodates oversized bicycles and alternative bicycle types must be provided as follows: 1. Each oversized bicycle parking space must provide minimum clear area of 4 feet by 8 feet as shown in Figure 4.6-C. 2. At least 10% of the long-term bicycle parking spaces for commercial uses and residential uses must be oversized bicycle parking spaces. Response: One oversized bicycle parking space (10 percent ofthe required long-term parking) can be provided, as necessary, on the outside of the bicycle rack. 4.6-150 Bicycle Parking — Facility Improvements A. Bicycle Parking Location and Security. 1. Bicycle parking racks, shelters, or lockers must be securely anchored to the ground or to a structure. Response: Bicycle parking racks will be securely anchored to the ground, consistent with this provision. 2. Exterior long-term bicycle parking must be located within 200 feet from the main building entrance, primary point of entry to the use, or employee entrance. Response: Exterior long-term bicycle parking racks are located within 100 feet from the restaurant building entrance, consistent with this provision. 3. Exterior short-term bicycle parking must: a. Be located no further than 50 feet from the main building entrance or primary point of entry to the use, as determined by the City, but not further away than the closest onsite automobile parking space excluding designated accessible parking spaces, whichever distance is less; and b. Be clearly visible from the main building entrance or primary point of entry to the use. too WL Page 43 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 Response: Exterior short-term bicycle parking racks are located 40 feet from the restaurant building entrance and are visible from the main building entrance, consistent with this provision. 4. Bicycle parking shall be separated from motor vehicle parking by a barrier, curb, or sufficient distance to prevent damage to parked bicycles. Response: Bicycle parking will be located immediately adjacent to the restaurant building, separated by curbing to prevent damage to parked bicycles. 5. Where bicycle parking facilities are not directly visible and obvious from the public right-of-way, signs shall be provided to direct bicyclists to the parking. Directions to sheltered facilities inside a structure may be signed or supplied by the employer, as appropriate. Short-term parking shall be made available to the general public. Response: The applicant anticipates that bicycle parking will be visible from the public right- of-way, either from Gateway Street or the southern drive aisle. 6. Bicycle parking may be located inside a building on a floor, which has an outdoor entrance open for use, and which does not require stairs to access the space. EXCEPTION: The Director may allow bicycle parking on upper stories within multi -story residential buildings. Response: The applicant anticipates that bicycle parking will be visible from the public right- of-way, either from Gateway or the southern drive aisle. Bicycle parking and bicycle racks must be located to avoid conflict with pedestrian movement and access. Direct access from bicycle parking spaces to the public right-of-way must be provided by at - grade or ramp access. Pedestrian access must be provided from the bicycle parking area to the building entrance. Bicycle parking may be located in the public sidewalk or right-of-way where there is a minimum 5 feet between the parked bicycle and the storefront and does not conflict with pedestrian accessibility. Response: Bicycle parking will be located adjacent to the restaurant building, separated from pedestrian walkways. The applicant does not anticipate bicycle parking will conflict with pedestrian movement and access. B. Employers with changing rooms and shower facilities or other additional amenities may be eligible fora 10% reduction of Transportation System Development Charges if the Director determines that those facilities encourage bicycling or other active modes of transportation by employees or patrons. 4t7 0 W L Page 44 Type II Site Plan Review (Pre -Submittal) I Chick-fil-A #04967 Response: The applicant anticipates no changing rooms and shower facilities or other amenities will be provided with the development of the project site. 4.6-155 Bicycle Parking — Number of Spaces Required Table 4." Minimum Required Bicycle Parking Spaces Long and abort -Term Bicycle Use Catwory specific uses Number of Required Spaces Parkins Percentages Commends] General retail 1 per 3.000 square feet of floor area 25% long-term 75%short-term Eating and drinking 1 per 600 square feet of floor area 25% long -ten establishments 75% short-term Service establishments 1 per 2.000 square feet of floor area 25% long-term 75%short-term Art lnsthuflOngallery 1 per 1,500 square feet of floor area 25% long -tend 75%short-term DrIve-through only 2 for employee parking(minMum of 4 does not 100%tong-term establishments apply) Lodging 1 per 10 rentable rooms 75% long-term 25X short-term Omce, Including medical 0.75 per 5.000 square feet of floor area 7:% 'o offices and clln]¢ 25%short-term Industrial and wholesale 0,25 per employee OR 1 per 4.000 square feel of 75% long-term floor area, v.Tlchever a was 25%short-term Response: The proposed Chick-fil-A restaurant will be 4,987 square feet. Therefore, nine bike spaces are provided (four long-term, six short-term). 4.7-100 Specific Development Standards 4.7-145 Eating and Drinking Establishments The cumulative total area of sit-down restaurants and delicatessens, secondary retail uses and exercise studios in the GO District shall be limited to no more than 10 percent of the gross floor area of the office building in which they are sited. Response: The project site is not in the General Office (GO) zoning district. Therefore, this provision does not apply. IE30 WL Page 45 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 5.0 GATEWAY REFINEMENT PLAN Commercial Element Policies and Implementation Actions 2.0 Improve the appearance of the freeway commercial area around the intersection of Gateway Street and Belt Line Road. 2.1 As part of the site plan review process for development, require all landscaped areas to be at least 75 percent covered with living plant materials within 3 years of the date of installation. Response: The landscape plan includes a note that at least 75 percent of landscape areaswill be covered with living plant materials within three years of the date of installation. In support of this statement, the landscape architect has designed an automatic irrigation system and anticipates soil depth and organic composition is compatible with the plant species selected. The landscape plan is included with this application as Sheet 11.0 of Appendix 4. 2.2 Through the site plan review process requires 7.5% of the interior of parking lots visible from arterials and collectors to be landscaped. Require vegetative screening of parking lots. Allow such vegetative screens to include shrubs to 3'/]' high, except in vision clearance areas. Response: The landscape plan indicates the majority of perimeter parking (17,372 square feet) will be screened by a three foot tall evergreen shrub hedge between the interior parking lot and Beltline and Gateway Street. The location of the parking lot is interior to the project site and as such, no conflict between vegetation height and vision clearance areas is anticipated. The landscape plan is included with this application as Sheet 11.0 of Appendix 4. 2.3 Require properties developing along the potential access routes to the McKenzie -Gateway Special Light Industrial site to provide planter strip and front yard landscaping designed to enhance the site's entryway. Examples could include additional street trees and landscaped areas. Response: No access to the McKenzie -Gateway Special Light Industrial site is proposed with this project. Therefore, the applicant anticipates that this policy does not apply. 2.4 The City shall explore siting and construction of a "Welcome to Springfield" sign in the vicinity of the Gateway/Beltline intersection. The sign shall be aesthetically designed and visible to travelers entering the Gateway area from Belt Line Road and 1-5. Surrounding park -like landscaping should be considered and encouraged as part of this entry design. Response: The applicant anticipates that a Welcome to Springfield sign would be placed at the Intersection of Gateway and Beltline on tax lot 1703222001201. The project site is located to the south of the speculative sign and therefore, the applicant 41ttJ 13 W L Page 46 Type II Site Plan Review (Pre -Submittal) I Chick -til -A #04967 anticipates no significant conflict with future siting considerations for the city welcome sign. 5.0 CONCLUSION As evidenced through this narrative and associated documents, the applicant's pre -development review application is consistent with the applicable local policies and regulations governing the allowance of these requests. Therefore, the applicant respectfully requests the City of Springfield's approval of this application. 4013WL Page 47 City of Springfield Development & Public Works 225 Fifth Street Springfield, OR 97477 Site Plan Review SPRINGFIELD � Site Plan Review Pre -Submittal: ❑ Major Site Plan Modification Pre -Submittal • ❑ Site Plan Review Submittal: or Site Plan Modification Submittal: A licant Name: Steve Schwartz phone. 303.519.7206 Company: Chick-fil-A, Inc. Email: Steve. schwartz@ Address: 15635 Alton Parkway, Suite 350, Irvine, CA 92618 cfacorp.com Applicant's Rep.: Andrew Hunt Phone: 760.214.8362 Company: 4G Development & Consulting, Inc. Email: ahunt@4gdev.com Address: PO Box 2//70571, San Diego, CA 92198 Pro ert Owner: IVI1: /�,�. /,j;,,: ZS Phone: 511 1$` GElj Company: Glc - 1%) f .i .. o- (1 2L-_ r-.: Tree / 42� Email apo' i7s'"«er.c.0� Address: F -Y& 4M�i�r ASSESSOR'S MAP NO; TAX LOT NO S < /r Property Address: ] }�% r� � '��✓�.. �J r:z-i. _5 �; ',q � tG/, ��f� �f�`l7� Size of Property: , V ropuse No. of _ (�- Pro osed Name of Pr -A - Description of If you are filing in this form by hantl, please attach your proposal description to this applkation. Pro osal: Proposed Chick-fil-A fast food restaurant with dual drive-thru la Existin Use: Hotel/Motel and Elmer's Restaurant. New Im envious Surface Covera a Includin Bld . Gross Floor Area): sf Si natures: Please si nand riot our name and date in the apprc riate box on the next a e. Associated A lications: Signs: Pre -Sub Case No.: Date: Reviewed by: Case No.: Date: Reviewed b : Application Fee: $ Technical Fee: $ Posta a Fee: $ TOTAL FEES: $ PROJECT NUMBER: Revised 1/7/14 KL 1 of 11 as. Plan View Scale - 1" = 25R + 'es 'ab +ab a.5 +p] 'a5 0.5 a.5 'a.5 *a.5 __ __ ___ _._ _. +05 'a.5 *08 'a.9 a.] '01 'a8 a8 'a8 'OA '0] 'O8 '8 'O8 +0A '3 +op +op +op +0a +a.a a.2 +a.a - _ _ I _ _ _ 'a5 'p8 'a. '09 '1A '1.1 '1.5 '18 13 '1A +02 'p8 'p8 'O8 '09 '1.1 ' 3 '1.2 'a.9 '0.5 j pAi I a1 'a.] '09 '1.1 '13 '1A '18 'l8 'l] '2p '1.5 '13 '13 ,-,+ '09 '1A '13 '18 '18 1A 'a.B 00 a.1 ap +al SA +u +1A +19 +2g +a2 +aa '2a 42a Sl SA +v +1. +u +1e +22 v +1.2 ae 'p8 '11 '18 'lp 'l8 '32 '5.5 '3< 'l] '21 '18 '13 '1. '11 '2.1 '29 32 '197 j a.1 *p9 *13 *19 *. A *31 8 *1 *1.5 *3p *37 *32 A< '2.1 00 a.2 *1A *13 *3p *38 *38 *38 *5 �ay,+88 '39 '38 *3A *23 18 *1.5 *1.7 *23 *32 *32 3.5 '22 W7,/5'9'J +02 'IA '11 '1A '2.1 '38 '37 'Ap '88 ']2 '43 '39 '3A '25 A '1.7 '18 '34 '33 #r '13 � I a°! 00 I I'12 15 + +� '43 '87 ']2 'Ag 1] + '27 ' 1 '19 '1 1 3 '33 3.6 +2.5 II 'a.3 II '13 +11 23 28 33 'A< '] 2 '] g 'A8 '3.5 (11 '29 < 1 '2 '2T '3 ' 'L.9 8 ± ___ _ _ __ _ __ _ _ _ _ --------- _ _ _ _ _ ________ --I I 0 'a.2 'a.2 *a.L *a.5 'a.] 'a.] 'a.] 1 'aA I 00 I I y '14 '18 +2d '28 '32 '<.5 ']p '73 '5.1 43<'3 A '2. +22 + + + + +1.2 '1.0 'a8+ + .Aus'13 '18 '22 '28 '3< 'A3 ']3 ']8 'A] '38 '35 '31 '27 '23 '2.1 +2'� *< M]3 *8.9 • 1 � 'a1 5�+*8A 'I 3e ® *p.] *fA ➢.] m *1A *15 *11 811 *a.] I '00 0] � 11 I '1A '15 5 '28 '3g 'A2 '6.5 +7.1 '<.5 39 35 '<A 38 '3p ' 3 '2.1 -SO 6 * 9 '40 ] ].5 0a *13 *18 *2A *"1. 'a. I 1 A +1A '22 +29 +38 +4A +89 +73 +A20 38 A] +43 + +2.5 +2.2 3 +'1.3 *2.p *3. +]5 +16 +0, <ai1 11 +02 +02 '03 403 +a8 +09 21 +2a +v +39 +eg +7.1 'a2 43a +38 +51 A 3. '3.a 'E. 8 \'31 '3.a `aa +20 +5 +.2 1 4- 0 ° oo0"O4 0 +0.2 +03 '03 40.5 +p8 +09 +13 +2p +2.5 +32 +37 +5.7 +6.2 +3.8 43.5 +32 +5A *m9 *A2 3.3 '12.8 ] +36 8 +2 T,i 'p5 +03 II I=13ILS ILIR� 11 ®S34S* 11 *.3 *03 *0.5 *OB *01 *09 *13 *1.B+22 *27 *33 *&0 *3.8 *2.B *28 *LB *l] *l< *2.7 * .5 8 J.8 K3.9 .� +p, 'a.3 87 SP 1 1 *aA +0a +0a +p.] *a8 *12 *15 181 *2p *22 '28 'Ap +<. +3.0 *2.2 *2 *LA'I NA 04A *3. '2A *L. _ _ _ _ _ _ b.] „�'�6 'd0 *A2 *3211 *p +a.3 - y +0.5 4.8 'aP 49 '12 '1B '18 '1P '1P '19 '22 '27 37 '19 '42 *sA *m2 *3A *2A ''33 3 319 2 a] 37 35 b_p. 3 'all + +a.ai --_- ______- _- - ____- _____ ---- 1 +01 '09 '1.1 '13 +18 +22 +2A +2.1 +19 +18 +18 +2p '19 '1. +1.1 +13 +38111 *<A i.8 *3. *2.81 *2 /2 118 '15 p*1.L 1"IA *1A *1A *1a *11 *18 18 'i *19 '2.5 ��.3 *41 Ns +35i +13 O8 %2 �4 t +23 +33 +35 +28 1 t9 +18 +11 '1.5 *12 � +� +2.7 * p .1 �0 '2 ��' '4Q 18 698 '18 '11 '11 A '2A '22 ' l �1l _ _'2.p 'I 23 *2g NA +511 '15 +0a 1!! +09 +1A +11 42.1 +29 +42 +53 +34 +2.5 +2.1 +18 +1A +1.1 +p. +0A a.] +18 '3A '3 '42 8 '2.5 '2.2 '2.3 '23,..:.1 '23 A '3A *3S 3 '2.1 / �1-a +19 +0a i1! +1A +18 +2p 427 +3A '55 +62 +38 +3p +23 +19 +13 +09 +p. 408 +8 +12 '31 '< B.2 '48 '3.1 '2.8 '2.8 '28 A '28 '3S i.8 '4g '2.9 8 '1458i 3 III +0a -I +1A +11 +23 432 +35 +g0 +65 +39 +3.5 +2g +2p +13 +09 +p. 408 +1.1 +2A '22 '2A i.2 NA 9 '5.'31 '3.2 '3.1 '32 '3.1 '35 '4.3 'g. '3 3 44 3 'g.8 -1 i+ r +0a i +1.1 +11 +2.5 433 +35 +53�+5] +3] +3g +27 +2p +13 +09 +p. 401 +11 +181 '22 72.8 '3.5 5.p %.2 '5. '3S '31 '3.5 '35 '35 '39 L.] '].a 5.6 '31 l Na 92 -'k 58' .2 *pg I a. a.b +1A +11 +22 '3.1 +3A '51 +63 +38 +34 +2.5 +19 +13 +09 +p. 401 +1A +1.]' '22 2.9 '3a '<.5 '<. '3S '3A '3A '38 '37 ND L.5 '49 '31 9 ' $ " 5 I +8 *pg I i 1 +03 +1A +18 +2p '2g +32 +55 +g.1 +3g +28 +22 +18 +1.2 +a.8 +a. '0] +1A +18 ''2.1 l 3< '48 %.p '5. 3.9 '"a.8 '3.5 3.5 i.5 '39 <a *].0 b.3 3.8 8 '4411 91 'ae 65 � +221i +p8 03 '1A +1A +11 +2.0 *2.] *L5 *L8 *3.1 +22 +18 +1.8 +1.2 *0.9 +a. +08 +1A 15 +2.1 +2i 30 04< B.9 b.2 3.8 3'3S 33 32 38 04S "T b.3 .5 .1 40 58 22111 +a.] 1 ,,.�+_ +p3 '09 +13 +1A +18 +21 +29 +31 +24 *A�-r.8 *1A *1.2 *1.a *a.B *a.8 *1.1 *1A i *1B *2.1 1X2.] 40 i 3+4. 3.1 3.9 '32 33 33 33 *4< S.8 *48 *2.8 *28 A *38 A *35 *1 ]I +al 0.8 +1A +13 +13 +15 +20 +20 +11 +1 +13 +1.1+ 9 +1A +1.1 +1A i *18 1X18 *2. � � +3 '2.9_ _ '2.8_ 03e_ _ 33 _ _ 3A 38 304S _____040 - 31 +2.5 '2. '1B 0 +1311 03 'al __ _ +a.8 '09 '1A '1.1 18 +15 +13 +13 +13 +A +1. '1.1 +12 18 �// '2.$ 'S.6 '2. + g '2A ' '3a 33 + '38 ND * A '44 ' '38 '2A ' '25 '2.2 '18 13 '2.2 1l +1Aii +03 'al \ +a8 '1A '1.1 '13 +15 8 +1A +13 +1.2 +1 +1.1 +1.1 1. +1.1 *1.2 +13 +18 f +11 +18 � ] '19 '2.1®�--''i -.a .8 '3.2 35 'aA '4.2 '43 *3.8 '3.2 ].]® *2.1 ®18 t2 'y� +1 +a.] +1.a 1. '13 418 +2A +18 +4 +1.4 +13 13 +13 +13 +1. +1.4 A +20 +22 +19 +11 '19 '19 '2.1 a i.2 *42 '41 '4p '4.1 3A *3A l '2.2 '18 +13 +09 +a.s j +1.2 +1A +18 422 +30 +30 +22 +11 +18 +1.5 +1.5 +1A +1. +18 411 +21 +29 .5 3 8 +1.3 +es +l +0511 +02 +10 11 +1.5 +11 +2.1 43p +41 +<A +28 +2.1 +19 '11 +1.5 +1.5 +1] +19 42.1 +27 +<A +48 +33 +23 +19 +11 +1A 1.1 + +p.5 p.5 +OB +0] +01 +pA +aAl *02 +1.1 +1.8+2e +27 43< +59 '51 +33 +27 +2A +1.8 +1.5 +1.5 +1 +2.1 42g +32 '55 +63 +37 +28 +2.1 +11 +13 +O8 +0A 40.5 0'' +pA +pA +O8 +01 +pA li '03 +1.1 +0 +32 43g +1 +59 +35 +3.2 +2A +2A +1.8 +1.8 +2. 43.1 +35 +A +gA +38 +34 +2A 1.9 1.4 0.8 a.8 i 12 1A 22 2.2 2.2 19 2.5 28 2. 1.8 1.8 1.3 1.1 lz0 +1.2 111 ♦�� yt' +18 +2.5 < )♦a +yma, 0 +3A +3< +2] +2A +1.g +1.g +2 +2.g ♦ * +51,a.ar 8. +38 +3g +28 +2.1 1.5 +1.1 +1.1 +1.3 +1.] 5 +3] +43 +3.5 +3< +3] +4< +3 +2A +2.1 +18 +1A +131 'O8 +13 T ! '18 +23 +33 +38 *83 1 *35 *33 *2< *2.a '18 '1.5 +2. *2 +32 *35 *59 *g. *4p *3.5 *28 '2. '1.5 +13 *1.2 +1A *18 A *29 +32 +3.1 *3.1 +32 +3p 28 +24 +23 *22 *2.1 *1811 1 +1 1 +1A +2p +27 +34 +58 +5A +3A +27 +2.1 +1.5 +1.5 +1 +22 +28 +33 +53 +62 +38 +3p +23 + 9 +1.5 +13 +1.1 '1A +1A +18 '21 +27 +3p '3.1 +28 +2.5 +2.1 +2p +22 '23 +25 +2A li +' l +1A +1A +1.7 +2.1 +29 +42 +48 +28 +2.1 +1. g +1A +1A +16 +19 +22 +28 +42 +5A +34 +24 +19 +1] +13 +1.1 +1.0 '1.1 '11 +12 '15 +18 +19 +19 +19 +11 +1.6 +1A +2p +23 +29 +3A1 A +02 +1.1 +1.3 *1A '2.2 3.1 +31 +22 +1A +1.5 +1A +13 +1A '1. 1. '11 +22 3. +35 +27 +1A +1.5 +13 +1.0 +0.9 408 +01 +p8 +02 +1A +1.1 +1.1 +1.1 +1.1 +1.1 '13 '18 +2g +31 +45'i 3.1 +p8 i O8 1A %1 '1A +19 +19 +1A +13 +13 +1.1 +1.1 +13 '1. *1.3 +1A +1A +2.1 +22 +18 +A +13 +1.1 +1A a. +.g +a5 +a5 +aA +a.g +a.g +a.g +a.g +a.] +08 +1.1 18 +27 +33 +36I '3A +pA 11 +0A +01 +O8 40.9 +12 +12 +1A +1A +1A +1A 1.1 +1.2 +13 +13 +15 +1A +13 +A 1. +09 +8 I 1A +1.7 +27 +33 +3Ak *2.5 +aA 1. +e4 +0a +0A 40A +p8 +p8 +p8 + 8 +09 +09 9 1A +1.1 +1.2 413 +13 +1A +1A +13 +A +1A +09 + 8 1.0 +1.5 +2.5 +32 +3311 +2] 03 +3 +e4 40 +05 +05 +e6 +01 +O8 +1.1 1. +13 +1. 1.7 +18 +18 +1A +1A +13 +1A 9 I���yl /////���������� �� 09 +13 '22 +29 +38� +3A +03 II (� 11 -A +0.2 +0.3 '03 403 +03 +pA +p 5 +OB +O8 +1A +13 +1.5 +18 2. +2A +2. +2] +25 +22 +18 +1.5 +13 + .1 O8 +1.1 '11 +23 +33 A +29 li +02 +2p +0.2 402 03 +0 +0a +01 +1A +13 +18 +21 2 -3 +3A +32 +28 +23 +2p +1A +3 01 +0.9 +13 +19 +22 +a.1 11 +a.1 +a.1 +a.1 +a.1 +02 +02 +03 +Om +0A +p.8 +13 +11 +24 '3 +33 +3A +}.p +3.1 n +2.1 +1,$ +A Og +a.] +1.1 18 151 '13 +0.1 +a.1 +a.1 +0.1 +02 +a.3 *aA +a.g +09 +1A +2.0 +2.9 +3.6 +3A •+2A +32 +3.5 +2g +11 +13 +O8 *0< * 3 +02 +01 +01 +aO +Op +Op +Op +Op +Op +Op *p.3 *1.1 *1A f' p8 +a.1 ....... ..... ....... _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ *a.1.1 +a.a +aA +aA +0.1 +0.1 +0.1 +0.1 +0.2 +0.2 a. + . + +aA +aA + * . a.3 'a.2 +a.1 +a.1 +a.1 *aA +a.0 OA +0A +a.a +0A +a.1 tel +a. +0.4+aA 'a.] +a.] 0A 5/ 3/16/2022 cele of to Scale rowing No. C I I I I I Imm 4 m 20 4 3 I RANDY PAPE BELTINE 9 STALL: @9'X18' E4FEEE MPU PC. UP 17 P13 LS LRG 90 SEATS LOSS: 4,987 SF @9'X18' i I I "n"n" !Ni Y )STALLS @9'X18'1 'k 24.00' 16 2 1 1 7 STALLS 14 TYP 3200,. O v IN" nSITE PLAN NOTES 1. PROPOSED CONCRETE SIDEWALK 2. PROPOSED CFA STANDARD CATCHING/SPILLING CURB AND GUTTER 3. PROPOSED 4" WHITE PAINTED PARKING STRIPE 4. PROPOSED ASPHALT PAVEMENT SURFACE 5. PROPOSED DRIVE-THRU PAVEMENT MARKINGS REFER TO ARCHITECTURAL PLANS FOR BUILDING DETAILS 6. PROPOSED STANDARD A.D.A. STALL AND SIGNAGE 7. PROPOSED VAN ACCESSIBLE A.D.A. STALL AND SIGNAGE 8. PROPOSED WHITE PAINTED STOP BAR AND SIGNAGE 9. PROPOSED DRIVE-THRU EQUIPMENT AND SIGNAGE 10. PROPOSED DRIVE-THRU CANOPY 11. PROPOSED A.D.A. RAMP WITH TRUNCATED DOMES 12, PROPOSED TRASH ENCLOSURE, SEE ARCHITECTURAL PLANS FOR ELEVATION 13. PROPOSED DRIVE-THRU CONCRETE 14. PROPOSED WHITE PAINTED DIRECTIONAL ARROWS 15. PROPOSED CONCRETE PATIO W/ OUTDOOR TABLES & SEATING 16. PADS A AND B AND ASSOCIATED PARKING AND DRIVING AREAS TO BE DESIGNED AND CONSTRUCTED AT A LATER TIME. 17. PROPOSED BUILDING 18. PROPOSED 6"CURBAND GUTTER 19. PROPOSED LID STORMWATER FACILITY, SEE STORMWATER PLAN SHEET FOR MORE INFORMATION 20. PROPOSED PHASE II LID STORMWATER FACILITY, SEE STORMWATER PLAN SHEET FOR MORE INFORMATION I ILEGEND CIVIUS PROJECT # BOUNDARY LINE BUILDING EASEMENT CATCHING CURB & GUTTER ------------ - SPILLING CURB &GUTTER a SIGN e SANITARY SEWER CLEANOUT e STORM SEWER CLEANOUT ❑® STORM CATCH BASIN tli9ital files pmticcN fm abwenmeiprgW PROPOSED ASPHALT PAVEMENT '.°. PROPOSED CONCRETE I OREGON UTILITY NOTIFICATION CENTER 1-800-332-2344 ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER. THOSE RULES ARE SET FORTH IN OAR 952-001-0010 THROUGH OAR 952-001-0090. YOU MAY OBTAIN COPIES OF THE RULES BY CALLING THE CENTER. (NOTE THE TELEPHONE NUMBER FOR THE OREGON UTILITY NOTIFICATION CENTER IS (503) 232-1987.) 1 3 1 2 1 1 N 1 20 0 20 40 SCALE IN FEET ■ W® E o00� ma-ayo,) nq o 0 Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 720 SW Washington Street, #750 Portland, Oregon 97205 971-280-8641 RIIIIIIIIIIIIII LU I.i I.i C Q a J � _ 06z LL 0 / W Q UJ LUJ ILL 0 B �Q'^) z ILV FSR# 04987 REVISION SCHEDULE NO. DATE DESCRIPTION CIVIUS PROJECT # 14841.01 PRINTED FOR LAND USE DOCUMENTS DATE A1111012021 DMBy JLG ISO inmmnaicn cwaii,aa ca ms dnnw� am is aii � tli9ital files pmticcN fm abwenmeiprgW Z maY ^y bereproLxiin anY mvrrl WlFaY G exPrczz vnllenarvnbalcmvnlim G auYaizel pmRtl rcprcsWa4ves. LU SHEET U SITE PLAN O W CO SHEET NUMBER C2.0 _a Appendix 9 Drinking Water Protection (DWP) Application Exemption Request Return to: Amy Chinitz, Drinking Water Protection Coordinator Springfield Utility Board 202 South 1St" Street Springfield, OR 97477 Phone: 541.744.3745 Email: AmyC@subutil.com I SPRINGFIELD 1k D Drinking Water Protection (DWP) Application Exemption Request Required Project Information (Applicant., complete this section) Applicant Name: Steve Schwartz Phone: 303.519.7206 Company: Chick-fl-A,Inc. Email: steve.schwartz@cfacorp.com Address: 15635 Alton Parkway, Suite 350, Irvine, CA 92618 Applicant's Rep.: Andrew Hunt Phone: 760.214.5362 Company: 4G Development and Consulting, Inc. Email: shunt@4gdev.com Address: PO Box 270571, San Diego, CA 92198 Property Owner: Attn: Richards Boyles !Phone: 5412840613 Company: Sycan B Corp+ Olypic Street, LLC Fax: Address: 840 Beltline Rd, Ste 202, Springfield, OR 97477 ASSESSOR'S MAP NO: 17032220 TAX LOT NOS : 1300, 1600 Property Add reSS: 3350 Gateway Street, Springfield OR 97477 Associated Land Use or Building Permit Case No.: Planner: Andrew Limbird Existing Use: Motel and Restaurant Proposed Use: Restaurant Size of Proper : 4,49 Acres ® Square Feet ❑ Property The undersigned acknowledges that the Information included with this application is correct and accurate. The undersigned also certifies that the total quantity of hazardous materials on the subject site will not exceed the Owned amount listed in this ap lication and will not contain Dense Non -Aqueous Phase Liquids (DNAPLs). s. 4'r ^1 'r g/JJnature �f y /(rLn�r le r L. Z Print Date: Revised 1/1/08 Molly Markarian 1 of 3 DWP Application Exemption Request Submittal Requirements Checklist NOTE: If you feel an item does not apply, please state the reason why and attach the explanation to this form. ❑ DWP Application Exemption Request Form ❑ Proposal Description — provide a very brief description of the nature of the business or operation, as well as a description of how the business or operation will use, store, or produce hazardous materials Pleasesee attached project description and narrative responsewith findings for Spuny(ield Development Code (SDC) 3.3-200. ❑ List of All Hazardous Materials to be used, stored, or produced on the site (e.g., cleaning products, paints and paint products, pesticides, maintenance supplies, petroleum products, automotive supplies, etc.). Hazardous materials are defined as those chemicals or substances which are physical or health hazards as defined and classified in the most recently adopted or amended Fire Code by the City, whether the materials are in usable or waste condition. Commonly used office supplies do not need to be listed. The list should include the following for each hazardous material: ❑ Name of the product ❑ Manufacturer ❑ Total quantity of each product Response: Chick-fil-A uses cleaning, sanitizing, and disinfecting chemicals that are EPA registered products. Cleaning solvents, degreasers, and other cleaning chemicals are disposed in accordance with the manufacturer's label, Safety Data Sheets, and local, state, and federal regulations. Through daily use, cleaning chemicals are disposed into the sanitary sewer in diluted forms. Should bulk containers need to be disposed, the containers will be taken to a permitted local hazardous waste recycling facility. Revised 1/1/08 Molly Markanan 3 of 3