Shannon, We received a notice of incomplete submittal dated March 2, 2022 for the referenced site review
application. The following Dropbox location
https://www.dropbox.com/sh/73mobntvaw4woki/AAD4Y9YZNfPkiPtlQfrzxt4a?dl=0 contains the original and revised
drawings and supporting documents for this project. We have addressed all incomplete items as follows;
• Comment from the Eugene/Springfield Fire Marshal identified that the existing water supply is insufficient
(SDC 5.17-725). Sheet C2.0 has been revised to show the replacement of the existing undersized
fire hydrant and associated supply line at the northeast corner of the property. This water supply
improvement was identified and coordinated with the Fire Marshal , SUB Water and myself. The
project narrative has also been revised to describe this improvement under SDC 4.3-130.
• Demonstrate that a Traffic Impact Study (TIS) is not required per SDC 4.2-105 B. Sheet G200 has been
revised to add a Traffic Summary showing the calculations that demonstrate a TIS is not
required. In addition the project narrative has been revised to add the calculations and
references to SDC 4.2-105 B. to demonstrate a TIS is not required for this project.
• The submitted lighting plan is unreadable. Please provide a lager and legible lighting plan showing that
lighting levels at the property line does not exceed 0.7 FC. A larger version of the lighting plan is
provided as Drawing Sheets ES100 and ES101 that includes a larger, easier to read, photometric
plan showing that lighting levels at the adjacent residential zoned properties do not exceed 0.1
FC.
• Discrepancies in the following two plans: The 24" wall adjacent to the drive through facility is not shown
on the landscape plan. The stormwater plans and detail contradict each other. Landscape drawing
Sheets LA -1 and LA -2 have been revised to show a 3' CMU wall adjacent to the drive through
facility. Sheet C2.0 has been revised to show an overflow pipe symbol instead of a catchbasin at
the stormwater treatment facilities consistent with the Rain Garden detail on that sheet.
In addition, a new Title Report dated March 14, 2022 has been provided. Please let me know if there are any
questions about the revised submittal documents.
Mikael Shields, P.E. I Civil Engineer
Johnson Broderick Engineering, LLC
325 West 13th Avenue, Eugene, Oregon 97401
Office: 541.338.9488, x1008
Due to the Covid-19 pandemic, the majority of the JBE team is working remotely, as are many of our colleagues and
partners.
JBE offices are closed to all visitors for the foreseeable future.
We are available by phone during the business day. Given short notice we will arrange or participate on a video
conference. Site services take a bit of planning, let us know what you need.
CONFIDENTIALITY AND PROPRIETARY INFORMATION NOTICE: This email, including attachments, is covered by the Electronic Communications Privacy
Act (18 U.S.C. 2510-2521) and contains confidential information belonging to the sender which maybe legally privileged. Nothing contained in this
message or in any attachment shall constitute an Electronic Signature or be given legal effect under 44 U.S.C. 3504 Sec. 1]0]. The information is intended
only for the use of the individual or entity to which it is addressed. If you are not the intended recipient, you are hereby notified that any disclosure,
copying, distribution or the taking of any action in reliance of the contents of this information is strictly prohibited and maybe unlawful. If you have
received this electronic transmission in error, please immediately notify us by phone. Do not review or forward, and immediately delete and destroy all
copies of this email and any attachments.
CB ANDERSON
ARCHITECT
Date: 27 September 2021, Revised 20 January, 2022, Added 4.2-105 on March 8, 2022
To: City of Springfield, Oregon
Re: TYPE II SITE PLAN NARRATIVE FOR:
Site Address:
1570 Mohawk Blvd, Springfield OR
PROJECT NARRATIVE
Project Scope: The redevelopment of a site from a commercial structure with a drive
through (bank) to a restaurant with a drive-through.
The site is situated near and across the street from other buildings of its same type.
The site directly abuts six other properties, four of which are zoned low density
residential, one is community commercial, and the other is mixed use commercial.
Site design has paid close attention to where the drive -up ordering posts are located,
and we are mitigating that potential noise with a 6' high concrete masonry unit (cmu)
fence. These cmus are well suited for blocking sound. We will also be texturing these
blocks and varying their color in a visually pleasing manner.
Site design has also paid close attention to the drive-through's direction at pay and
pick up windows with respect to Mohawk Blvd. We are proposing a 3' high wall in this
area along with landscaping. That 3' wall is intended to look and feel like the building.
We have looked at numerous schemes, and in the prior DIM meeting, I believe we
agreed that this orientation now further progressed was the most feasible.
We understand that 1% of our building cost needs to go towards a public art
statement. We are proposing a location and suggesting an artwork approach that
would provide maximum visibility and opportunity for public enjoyment. It is on the
corner of an intersection and near a bus stop.
As suggested in G200, the artistic goal would be to weave together a variety of
colored and textured ribbons of sidewalk, each representing different voices in the
community. Some sidewalk strands might have rocks in them, or another embedded
colored glass, or another slices of local rock set in like pavers, another tinted, another
with embedded impressions, another with tiles fragments and mosaic pieces, and so
forth.
Peak staffing, during meal times, is expected to be between 8 to 10 persons. Between
peak times, staffing is typically 6 or less persons.
208782-2911 7209Gr nwe Ave N
F: 208.782-%24 S WeWA98103
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
Following are additional items requested by the Tentative Site Plan Review
Application Pre -Submittal Checklist. We will only address items marked "incomplete"
Copy of the deed and a Preliminary title report (note 1): A more recent title report is
provided.
Brief narrative (note 2):
Following is a brief summary the Mixed -Use Commercial Design and Development
Standards, SDC 3.2-600 and SDC 5.17-125's criteria of approval explaining how each
standard and criterion is met:
SDC is in blue colored text for context and the convenience of the reader.
How this project complies is in bold, black text as briefly as we are able to write
CHAFFER 3 LAND USE DISTRICTS
Section 3.2-600 Mixed -Use Zoning Districts.
3.2-605 Establishment of Mixed -Use Zoning Districts
This project is: MUC
A. Mixed -Use Commercial District (MUC). The MUC District is established where a mix of commercial with
residential uses is compatible with existing nearby uses. Development within the MUC District shall have a
commercial dominance, with residential and public uses also allowed. The primary development objectives of
the MUC District are to expand housing opportunities; allow businesses to locate in a variety of settings;
provide options for living, working, and shopping environments; facilitate more intensive use of land while
minimizing potentially adverse impacts; and to provide options for pedestrian -oriented lifestyles. Development
areas one acre or more in size in the MUC District shall have frontage on either an arterial or collector street.
Access to any MUC development area may be from a local street, if there is no negative impact on adjacent
residential uses.
3.2-610 Schedule of Use Categories
This project is: Eating and Drinking Establishments.
Delicatessens and sit down restaurants including espresso shops: P (permitted)
Drive up restaurants and espresso shops (Section 4.7-180): S (SPECIAL DESIGN STANDARDS subject to
special locational and siting standards to be met prior to being deemed a permitted use (Section 4.7-100).)
3.2-615 Base Zone Mixed Use Development Standards
Oereio mentStandwd
MUC
This Project
Minimum Area
6,000 square feet
32,507 = OK
Minimum Street Frontage(1)
40 feet
250+ feet on
Mohawk
157+ feet on
171^ Street =
K
Maximum Lot/Parcel Coverage
Lot/parcel coverage standards in
ee Site
the MUC and MUE Districts shall be
lans
limited only by standards
(including, but not limited
to: required parking, landscaping)
specified in Sections 4.4-105 and
Page 2 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
Deveio rnentStandard
MDC
71yisproject
4.6-100. Generally, there is no
maximum lot/parcel coverage
standard.
Minimum Landscaping
Minimum requirements defined by
See
standards in other Sections of this
Landscape
Code.
Plans
Landscaped Setbacks(2), (3),(4) and 5
Front Street Side Yard and Through Lot/parcel Rear Yard
Building Setback
None
18+/-f eat =
OK
Parking, driveway, and outdoor storage setback
5 feet
5 feet = OK
Interior Side Rear Yard Setbacks when Abutting Residential or CI Districts
Building Setback
10 feet
23+ feet =
OK
Parking, Driveway, Outdoor Stora a Setback
5 feet
5 feet = OK
Maximum Building Height(6)
Maximum unless abutting residential districts (See
90 feet
22 feet
below
When abutting an LDR, MDR, or MUR District to the
Defined by the Maximum Shade lbutting
LDR,
north
Point Height requirement
nit building is
of Section 3.2-225A.1.b., or up to
my 22 feet tall
50 feet south of a northern
ind more than
lot/parcel line a plane extending 22
feet away
south with an angle of 23 from
all = OK
degrees and originating from the
top of a 16 foot hypothetical
fence located on the northern
lot/parcel line.
When abutting an LDR, MDR, or MUR District to the
No greater than that permitted in Abutting
LDR.
east, west, or south
the LDR or MDR Districts for a LDR
max is 30
distance of 50 feet. feet.
This
rojectis 22
feet
=OK
(1) The Directorrey waive the requirement that buildable City lots/parcels have frontage on a public street when all of the following
apply:
(a) The los/parcels have been approved as part of a Development Area Plan, Site Han, Subdivision or Partition application, and
(b) Access has been guaranteed vu a private street or driveway by an irrevocable joint use/access agreement as specified in Section
4.2-120A
(2) There are no setback requirements for buildings in the Downtown Exception Area.
(3) Where an easement is larger than the required setback standard, no building or above grade structure, except a fence, shall be built
on or over that easement.
(4) Required setbacks are measured from the special street setback in Satan 4.2-305N, where applicable.
(5) Architecturzl extensions may protrude into any 5 -foot or larger setback area by not more than 2 feet
(6) Incidental equipment may exceed these height standards. In the NUE District, incidental equipment exceeding the height standards
cannot occupy additional floor space.
3.2-625 Mixed -Use District Development Standards—General
Page 3 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on 8 March 2022
Mixed use zoning distracts require special attention to building design because of the intermixing of land uses
and higher intensity of development that can occur in these areas. The standards below implement commonly
accepted design principles with the goal to achieve more attractive, functional and pedestrian oriented design.
Not every case and circumstance is anticipated by these standards, nor is it the goal of this Section to
prescribe every design detail of development. It is expected that the Springfield development community will
apply their own design creativity to build on these principles and create attractive, livable, and viable projects.
The standards below provide an objective framework for achieving the desired goal of attractive, pedestrian
oriented development. Developers may choose to meet these standards as prescribed, or they may propose
other design ideas which are equal or superior to a particular standard in meeting the design objectives in
Subsections A. -G., below. Where developers request an exemption from a stated standard, it is their
responsibility to propose an alternative design and to demonstrate to the Director that it is equal or superior to
the stated standard. The Director has the authority to authorize an exception to these standards and
determine the acceptability of an alternative design the developer proposes. When developers propose
alternative designs that are not acceptable to the Director, they may appeal the decision as specified in
Section 5.3-115.
A. Building Design Standards. Intent: New structures and improvements to facades requiring
building permits shall provide architectural relief and interest, with emphasis at building entrances and
along sidewalks, to promote and enhance a comfortable pedestrian scale and orientation. Blank walls
shall be avoided to the maximum extent practicable by complying with the following minimum
requirements. The following standards are intended to be specific and quantifiable while allowing for
flexibility in design.
1. Ground floor windows shall be required for all civic and commercial uses. Al
elevations of buildings abutting any street shall provide at least 50 percent of their length
(e.g., a 100 -foot wide building facade shall have a total of at least 50 linear feet of windows)
and at least 25 percent of the ground floor wall area as windows and/or doors that allow
views into lobbies, merchandise displays, or working areas. On corner lots/parcels this
provision applies to both elevations.
EXCEPTION: Elevations of buildings adjacent to alleys or vehicle accessways used primarily
for service and delivery access is exempt from this requirement.
This Project: The primary entrance facade faces NE. It fronts 17th Street and with
access to much of the parking. It is 41.083 feet long. 31.75' of it is storefront,
which is 77+%.
All three other facades are limited access due to vehicle accessways for food
delivery. Therefore, we believe these three other facades are exempt. However,
that does not mean these three other facades are lacking interest or allowing
visibility into dining areas. The SE facade of the dining room facing Mohawk is
23.67' long. The storefront windows along that side are 12 feet wide, which is 50+
% of the facade. The remaining facade is painted by a DHC art team.
2. Ground floor windows are required as part of the primary entrance elevation for all
industrial uses. Windows are required for at least 30 percent of the primary entrance and
ground level offices that are part of the entrance elevation. The windows shall be measured in
linear fashion (e.g., a 100 -foot wide building entrance and office facade shall have a total of
at least 30 linear feet of windows and/or doors on the ground floor that allow views into
lobbies, merchandise displays, or working areas).
This Project: n/a
Page 4 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on 8 March 2022
3. Along the vertical face of a structure, offsets shall occur at a minimum of every 50
feet by providing at least one of the following:
a. Recesses, including, but not limited to: entrances and Floor area with of
minimum depth of 4 feet.
b. Extensions, including, but not limited to: entrances and Floor area with a
minimum clearance of 4 feet, a minimum depth of 4 feet, and a maximum length of
an overhang shall be 25 feet.
C. Offsets or breaks in roof elevation with a minimum of 3 feet or more in
height.
This Project: The main fa5ade length this applies to is 66.081 feet. We propose
visual interest through a 7 -foot extension canopy at the drive-through pick up
window. That canopy is approximately 13.5 feet wide and 4 feet tall. The building
does also jog at one of the ends of the canopy, but it is 20 inches instead of 48
inches. We believe that the combination of the large extension canopy and jog in
the building meet the spirit and intent of the development code.
4. In order to break up vast expanses of single element building elevations, building
design shall include a combination of architectural elements and features, including, but not
limited to: offsets, windows, entry treatments, wood siding, brick, stucco, textured concrete
block.
This Project: We feel that the Dave's mural art and the three -color approach
address the "vast expanse' concern for building elevations. The building's primary
fa5ade along Mohawk creates a central, red -colored box covered by a larger
vehicle overhang that has a 54 SF face projected 7' out from the building. The
dining segment of the structure that includes windows is recessed 20 inches and
in a light gray color. The dark gray segment at the kitchen serves as a backdrop for
the sign and Dave's mural art.
S. In order to provide differentiation between the ground floor and upper stories,
building design shall include bays or balconies for upper levels, and awnings, canopies, or
other similar treatments for lower levels. Variation in building materials, trim, paint,
ornamentation, windows, or other features including public art, may also be used.
This Project: n/a for 1 -story
6. External modifications proposed for structures listed on the Springfield Historic
Landmark Inventory shall comply with the applicable standards specified in Section 3.3-900.
This Project: n/a for new construction
7. The proposal contains an equally good or superior way to achieve the intent of
Subsections 1. through 6., above.
This Project: As noted above, Dave's Hot Chicken artwork, inside and out, is
unique to each structure and location following the style presented in our
submittal. Using the exterior color scheme as a backdrop, Spaltterhaus'
professional team of artist and painters fill the canvass with art, making the
building more of a living structure in the built environment.
Pa'C 5 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
B. Building Orientation and Maximum Setbacks. Intent: To the greatest extent practicable, all
new buildings in a mixed-use development shall be oriented toward both exterior and internal streets
in a manner that accommodates pedestrian comfort, convenience and safety.
1. In the Downtown Mixed Use Area, buildings shall be oriented towards fronting streets
in a manner that frames and defines both streets and pedestrian areas along those streets.
The maximum building setback in the Downtown Mixed Use Area is 10 feet. Buildings in this
area shall not be separated from fronting streets by off-street parking, vehicle circulation
aisles or drive-thru lanes.
EXCEPTIONS: Street setbacks in the Downtown Mixed Use Area may be approved by the
Director when:
a. The building design incorporates public seating, plazas, or other usable public
space as specified in Subsection G. below;
b. The building design incorporates landscaped stormwater quality facilities
within the setback area that also enhance the pedestrian scale, orientation and
interest;
C. Necessary to preserve existing healthy mature trees; or
d. Necessary to accommodate handicapped access requirements.
This Project: n/a — not downtown
2. Parking in the Downtown Mixed Use Area shall be located beside or behind buildings,
internal to development on a site. For existing development sites, outparcel buildings between
a large parking lot and the street shall be used to help define the streetscape, and lessen the
visual impact of the parking lot from the street.
This Project: n/a — not downtown
3. Public entrances to all new buildings in the Downtown Mixed Use Area shall be visible
from the street and oriented so that pedestrians have a direct and convenient route from the
street sidewalk to building entrances.
This Project: n/a — not downtown
4. In MUC Districts outside of the Downtown Mixed Use Area, buildings may be set back
from fronting public or private streets, but shall be connected to those by a continuous
internal sidewalk (and as needed, sidewalk crossings). This internal sidewalk network shall
connect customer entrances of buildings on a development site with one another and with
fronting public sidewalks or rights-of-way. The internal sidewalks shall be at least 5 feet wide.
The internal sidewalk network shall connect transit stops or station to buildings on the
development site to form a direct and convenient pedestrian connection with these transit
facilities.
This Project: The connecting internal sidewalk is located to facilitate as short and a
direct connection with the city sidewalk as possible to the corner and bus stop.
The crosswalk at the drive-through lane is located to maximize safety with driver
awareness of a coming turn in the lane. The 5' wide cross walk is also proposed to
be raised to further reinforce the pedestrian nature of the connection.
Pa,•c 6,fl 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
S. The proposal contains an equally good or superior way to achieve the intent of
Subsections 1. through 4., above.
This Project: address 1-4
C. Weather Protection. Intent: Awnings and canopies are intended to protect pedestrians from
the weather and add to the architectural interest of buildings. New commercial or mixed-use
residential development shall provide a weather -protected area adjacent to sidewalks and plazas.
1. Awnings or canopies shall be at least 6 feet wide, and shall follow building offsets to
eliminate long expanses of awnings and or canopies.
This Project: complies
2. Awnings and canopies shall not obscure architectural features (e.g., transom area) of
the building and shall not extend into the second story of the building.
This Project: n/a
3. Awnings and canopies shall be in proportion to the overall building and shall match
the width of the storefront or window opening.
This Project: n/a — not that retail strip mall style
4. Backlit awnings and canopies are not permitted.
This Project: the metal awning will not be back -lit, but it will have lights
S. Awnings and canopies shall be suspended from the building and not supported by
posts.
This Project: complies
6. The proposal contains an equally good or superior way to achieve the intent of
Subsections 1. through 5., above.
This Project: This section of the code seems to be addressing retail strip mall
concerns. Nevertheless, the building's fagade angles out over the entrances to
provide weather protection. And the large metal canopy serves as an artistic
element in addition to providing weather protection at the food delivery window.
D. Landscaping and Screening.
1. Intent: Landscaping is intended to compliment built forms within a development area,
softening and providing visual relief and contrast to buildings, sidewalks and parking lots.
Trees, as part of a landscaping plan, shall provide shade for pedestrian comfort as well. The
installation of landscaping shall be accomplished in a manner that assures that planted stock
receives adequate irrigation. Screening is intended to compliment a development area by
shielding trash receptacles, storage areas and other unsightly facilities from public view within
the development area.
Page 7 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on 8 March 2022
a. Mixed-use developments shall provide landscaping and screening in
accordance with Sections 4.4-100 and 4.4-110 and the following standards:
This Project: The existing fence to remain provides landscape and screening in
accordance with Sections 4.4-100 & 4.4-110.
b. Street trees shall be required consistent with Section 4.2-140. Species shall be
compatible with the design features specified in Subsection G., below and shall
provide continuity with nearby landscaping. The Director may grant a 1 -for -1
reduction in the number of street trees required when a development preserves
healthy, mature trees located within 10 feet of the sidewalk Required street trees
shall be placed in planter strips between sidewalks and curbs as specified in Sections
4.2-135 and 4.2-140, or in individual tree pits. If individual tree pits are utilized, each
pit shall be a minimum of 64 square feet per tree, with a minimum width of 4.5 feet.
This Project: Street trees have been added within the existing planting strip. The
trees have been selected from the City Street Tree List, are appropriately sized for
the planting strip and are less than 30' o.c. Please note, no street tree has been
added at the corner of 17th and Mohawk Ave due to an existing utility pole
2. Screening of parking areas, drives, mechanical equipment and trash receptacles shall
be as specified in Section 4.4-110. In addition:
a. No trash receptacles shall be allowed within the front setback areas abutting
residential districts.
This Project: There are no trash receptacles within the front setback areas
abutting residential districts.
b. All ground -mounted utility equipment not installed underground shall be
placed to reduce visual impact or screened with walls or landscaping.
This Project: Ground mounted utility equipment screened by landscaping. A
placeholder location for a potential pad -mounted transformer is shown as a
rectangle just south of stormwater planter 1.
C. Notwithstanding the timelines specified in Section 4.4-105, plants shall be
sized to attain 50 percent coverage in 2 years and 100 percent coverage in 4 years.
This Project: Current planting plan LA -1 complies with coverage requirements.
3. Irrigation systems are required to support landscaping. Drought -resistant plants are
encouraged. See Sections 5.17-120D.3. and 4.4-105.
This Project: Irrigation is design build. Irrigation notes added to LA -2. Drought
resistant plants are used where possible.
4. Parking areas, drives, and mechanical equipment shall be screened as specified in
Section 4.4-110. Trash receptacles shall be screened from on and offsite view by placement of
a solid fenced or walled enclosure, from 5 to 6 feet in height. No receptacles are allowed
within front setback areas abutting residential districts. Al ground -mounted utilities equipment
not placed underground shall be placed to reduce visual impact or screened with walls or
landscaping. Plants shall be sized to attain 50 percent coverage in 2 years and 100 percent
coverage in 4 years.
This Project: the new trash enclosure is enclosed by a concrete masonry wall 5 to
6 feet in height.
Page 8 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
S. The proposal contains an equally good or superior way to achieve the intent of
Subsections 1. through 4., above.
This Project: The landscaping and screening will complement the build form and
provide visual relief by using a combination of deciduous and evergreen shrubs.
Where possible native plants are used, and irrigation will be provided to all plant
beds. Trees have been appropriately placed throughout the site to provide a
comfortable pedestrian environment, with additional street trees added along
Mohawk Avenue. All mechanical equipment and trash receptacles have been
enclosed to meet the screening requirements.
E. Street Connectivity and Internal Circulation. Intent: To make mixed-use developments part of
a connected street system that serves vehicles, pedestrians and bicycles. Public or private streets
connect the development to adjacent neighborhoods and zoning districts. When street connections
are not practicable, pedestrian connections are made to and through the development in lieu of
planned street connections. Pedestrian connections shall equal what would be available if they were
on a street.
1. Streets and accessways of any one development or site shall interconnect with those
of adjacent developments or sites. Internal street or circulation patterns that isolate a
development from all adjacent developments, and only allow access to fronting arterial or
collector streets, shall be prohibited.
EXCEPTION: The Director may determine that topography and/or existence of natural
features of the development site would be better accommodated with an alternative
circulation pattern.
This Project will reuse existing curbcuts with the following changes at the request
of the city:
1. North drive -cut to be entrance only; south drive -cut to be exit only
2. South drive -cut to be pulled back about 4 to 5 feet, so that the exist is at least
24 feet wide, for two exit lanes, one turning north to the light for access to
northbound lanes on Mohawk and one turning south only, then on to Mohawk.
3. New directional signage and striping will be installed and maintained.
2. Streets and accessways shall align and connect to each other to create a direct and
convenient pattern of circulation that is consistent with the City's existing street and block
pattern in the area. The maximum block perimeter shall be 1,400 feet.
This Project: n/a
3. A mixed use development's street network (both public and private on-site streets)
shall connect directly to neighborhood streets in the surrounding area, providing multiple
paths for pedestrian, bicycle, and vehicular movement to and through the development area.
In this way, trips made from the surrounding residential neighborhood to the mixed use
development will be possible without requiring travel along a major thoroughfare or arterial.
Page 9 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
This Project: The existing curb cuts on to 171h Street, with an immediate
connection to southbound on Mohawk, and Olympic Street's traffic light comply
with this section of the code quite nicely.
4. Outparcel buildings shall be connected to and served from the internal streets of the
primary development area of which they are a part.
This Project: n/a
S. Pedestrian paths and sidewalks shall connect all building entrances with each other
and with public rights-of-way in a manner that is direct and convenient for the pedestrian.
This Project: The pedestrian path enters the site from the R.O.W. just north of the
bus stop. It becomes a raised crosswalk at the exit of the drive-thru, then on to a
larger patio with multiple directions of walking to either entry. Short-term bike
parking is alas conveniently located adjacent to the entrances.
6. The proposal contains an equally good or superior way to achieve the intent of
Subsections 1. through 5., above.
This Project: See above.
F. Neighborhood Compatibility. Intent: To achieve a compatible transition between mixed-use
and other zones of differing height, bulk and scale requirements, consideration shall be given to the
scale and design of surrounding buildings to promote compatibility and complement or enhance the
character of existing single-family neighborhoods. Development in mixed-use districts shall be
appropriate and related to the setting and established character of the surrounding area or
neighborhood. Minimum standards adjacent to Low Density Residential Districts are:
1. Architectural compatibility between new development and adjacent LDR development,
including, but not limited to: similar roof forms, windows, trim, and materials, shall be
required to the maximum extent practicable.
This Project: This building is 1 -story and so are the adjacent structures in LDR
zones, all of which primarily front different streets. The proposed Dave's Hot
Chicken structure is actually closer to the Taco Bell building on Mohawk than it is
to most of the other structures in the immediately surrounding LDR zones facing
16" and 17th Street. Therefore, similar window, siding, trim, and shallow sloped
hipped and gable roof forms would be n/a.
2. Lighting shall be arranged and constructed not to produce direct glare on adjacent
LDR development as specified in Section 4.5-100.
This Project: A photometric study of the proposed lighting show containment of
glare and light trespass on adjacent LDR sites.
3. Site obscuring landscaping shall be required, including, but not limited to: the
retention of existing vegetation; installation of a 6 -foot minimum height, site -obscuring fence
with shade trees planted a maximum of 30 feet on center (2 -inch caliper at planting); and/or
other landscaping to provide visual buffering.
This Project: There are existing fences currently in place that maintain a visual
buffer from our proposed development and the adjacent LDRs. For the most part,
Page 10 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
the survey identifies these fences as location on our property. Some of the fences
will likely be rebuilt to accommodate the new landscaping scheme.
4. Mechanical equipment shall be screened from view from adjacent LDR properties and
the street as specified in Subsection D.4., above. Mechanical equipment shall be buffered so
that noise does not typically exceed 50 decibels as measured at the LDR property line. The
City may require a noise study certified by a licensed acoustical engineer.
This Project: Understood. The roof top equipment will be behind an opaque
parapet wall, which corner is over 23 feet from the property line, and then
whatever additional space to the roof top units
S. The proposal contains an equally good or superior way to achieve the intent of
Subsections 1. through 4., above.
This Project: See above.
G. Pedestrian Amenities. Intent: To provide appropriate pedestrian amenities in mixed-use
developments, pedestrian amenities, including, but not limited to: benches, ornamental paving and
public art shall be provided and durably designed and integrated into an overall design scheme or
pattern.
1. All new structures and substantial improvements to existing buildings shall provide
pedestrian amenities, as specified in this Subsection. The number of pedestrian amenities
provided shall comply with the following sliding scale.
Size of Structure or
Substantial Improvement
Number of
Amenities
<5,000 sq. ft.
1
5,000-10,000 s . ft.
2
10,000-50,000 sq. ft.
3
>50,000 sq. ft.
4
This Project: 1 amenity. The public art is proposed in a visible public space
immediately adjacent to the bus stop and pedestrian entrance.
2. Acceptable pedestrian amenities include:
a. Sidewalks incorporating ornamental paving treatments, including, but not
limited to: concrete masonry unit pavers, brick, or stone, which are 50 percent wider
than required by this Code.
b. A public outdoor seating plaza adjacent to, or visible and accessible from, the
street (minimum useable area of 300 square feet).
C. Sidewalk planters between the sidewalk and building including stormwater
swales.
d. Street tree density more extensive than required by this Section.
e. Streetscape scale container planters.
E Installation of 3 -inch caliper size or larger to fulfill the street tree
requirement.
Page 11 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
g. Public art, including, but not limited to: sculptures, fountains, clocks, or
murals with a value equal to or greater than 1 percent of construction value of the
structure.
It. Pocket parks with a minimum usable area of 300 square feet.
This Project: A 450 SF area is proposed as a public art consisting of interweaving
ribbons of pavement in various colors, textures, and embedded elements such as
slices of local rocks.
3. Guidelines for the siting, construction and character of pedestrian amenities:
a. Amenities shall be visible and accessible to the general public from a fully
improved street. Access to pocket parks, plazas, and sidewalks shall be provided via a
public right-of-way or a public access easement.
b. The size or capacity of pedestrian amenities shall be roughly proportional to
their expected use, including use by employees, customers, residents, and other
visitors. The Director may alter minimum area standards for pocket parks and plazas
based on this guideline.
C. Amenities shall be consistent with the character and scale of surrounding
developments. For example, similarity in awning height, bench style, planter
materials, street trees, and pavers is recommended to foster continuity in the design
of pedestrian areas. Materials shall be suitable for outdoor use, easily maintained, and
have at least a 10 -year expected service life.
d. Bus stops, as a pedestrian amenity, shall conform to standards of the Lane
Transit District.
This Project: The location of the public art is proposed in a location that would
seem to maximize the potential for fostering community and continuity with
pedestrian access nodes.
4. The proposal contains an equally good or superior way to achieve the intent of
Subsections 1. through 3., above.
This Project: See above.
3.2-630 Mixed -Use Development Standards—Specific
A. MUC Development Standards.
1. Preservation of the Commercial Land Supply
a. One hundred percent of a new mixed use building footprint may be developed
for commercial uses.
b. A minimum of 60 percent of the ground floor area within a new building in
the MUC District shall be dedicated to commercial uses to ensure that commercial
land is preserved for primarily commercial purposes. Up to 100 percent of any
building may be developed for residential uses so long as 60 percent of the total
ground floor area within the development area is devoted to commercial uses.
C. The commercial uses on an MUC site shall be developed prior to or
concurrently with other proposed uses. Concurrency may be established by approval
of a Master Plan that provides a mix of uses that includes commercial and other
proposed uses.
Page 12 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on 8 March 2022
Proposed commercial structure is 2,915 SF. 100% of building footprint is
used for commercial.
2. Maximum Footprint for Retail Uses. The maximum building footprint for a grocery
store shall be 70,000 square feet. The maximum building footprint for other single tenant
wholesale or retail uses shall be 50,000 square feet. The maximum footprint for all other uses
shall be based upon lot/parcel coverage and building setbacks.
Proposed commercial structure is 2,915 SF. 100% of building footprint is
used for commercial.
3. Minimum Floor Area Ratio. A minimum floor area ratio (FAR) of .90 shall be required
for all new development or redevelopment in the MUC portion of the Downtown Mixed Use
Area. A FAR of .30 is required for new development on lots/parcels greater than 1 acre in the
MUC District outside of the Downtown Mixed Use Area. FAR is defined for this purpose as the
amount of gross floor area of all buildings and structures on the building lot/paroel divided by
the total lot/paroel area.
This project is n/a. The lot is 32,507 SF, therefore under 1 acre.
4.2-105 Public Streets
B. An applicant may be required to prepare a Traffic Impact Study (TIS) to identify potential
traffic impacts from proposed development and needed mitigation measures. A TIS is required if any
of the following criteria are met:
This project:
ITE trip generation 11th edition has land use (934) Fast food drive
restaurant with drive thru has a weekday rate of 467.48 trips/1000sq.ft
and a PM peak hour rate of 50.94 trips/1000 sq. ft.
ITE trip generation for land use (912) Drive-in Bank has a weekday trip rate
of 100.35 trips/1000sq.ft. and a PM peak hour rate of 20.92trips/1000sq.ft.
With an existing 3,650 sq. ft. Drive-in bank and a proposed 2,915 sq. ft. fast
food restaurant the project remains under the trip threshold for requiring a
TIA for the peak hour with 73 new peak hour trips and 996 new weekday
trips.
1. Peak Hour Threshold. If a change in land use or intensification of an existing use
generates 100 or more trips during any peak hour as determined by procedures contained in
the most recent edition of the Institute of Transportation Engineers Trip Generation Manual, a
TIS shall be performed by a registered professional engineer.
A Traffic Impact Study (TIS) is not required, because the proposal does not
exceed 100 peak hour trips.
2. Average Daily Traffic Threshold. If a change in land use or intensification of an
existing use generates 1,000 or more trips per day as determined by procedures contained in
the most recent edition of the Institute of Transportation Engineers Trip Generation Manual, a
TIS shall be performed by a registered professional engineer.
A Traffic Impact Study (TIS) is not required, because the proposal does not
exceed 1,000 ADT.
Page 13 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on 8 March 2022
4.3-130 Water Service and Fire Protection,
B. Fire hydrants and mains shall be installed by the developer as required by the Fire Marshal and the
utility provider.
Developer will coordinate with SUB water for upgrade of existing public fire hydrant as
shown on Site Utility Plan, Sheet C2.0 to meet required fire Dow per discussion with Fire
Marshal.
5.17-125 Criteria
The Director shall approve or approve with conditions: a Type II Site Plan Review application upon
determining that approval criteria in Subsections A. through E., below have been satisfied. If conditions cannot
be attached to satisfy the approval criteria, the Director shall deny the application.
A. The zoning is consistent with the Metro Plan diagram, and/or the applicable Refinement Plan
diagram, Plan District map, and Conceptual Development Plan.
This Project: n/a
B. Capacity requirements of public and private facilities, including, but not limited to, water and
electricity; sanitary sewer and stormwater management facilities; and streets and traffic safety
controls shall not be exceeded and the public improvements shall be available to serve the site at the
time of development, unless otherwise provided for by this Code and other applicable regulations. The
Public Works Director or a utility provider shall determine capacity issues.
This Project is smaller than the current multiple tenant commercial structure with a drive-
through
C. The proposed development shall comply with all applicable public and private design and
construction standards contained in this Code and other applicable regulations.
This Project: Understood, the project shall comply.
D. Parking areas and ingress -egress points have been designed to: facilitate vehicular traffic,
bicycle and pedestrian safety to avoid congestion; provide connectivity within the development area
and to adjacent residential areas, transit stops, neighborhood activity centers, and commercial,
industrial and public areas; minimize driveways on arterial and collector streets as specified in this
Code or other applicable regulations and comply with the ODOT access management standards for
State highways.
This Project: As noted above in the response to SDC 3.2-625 E.1, we are following the city
recommendations regarding the ingress -egress.
E. Physical features, including, but not limited to: steep slopes with unstable soil or geologic
conditions; areas with susceptibility of Flooding; significant clusters of trees and shrubs; watercourses
shown on the WQLW Map and their associated riparian areas; other riparian areas and wetlands
specified in Section 4.3-117; rock outcroppings; open spaces; and areas of historic and/or
archaeological significance, as may be specified in Section 3.3-900 or ORS 97.740-760, 358.905-955
and 390.235-240, shall be protected as specified in this Code or in State or Federal law.
This Project: n/a
End of response to Brief narrative for (note 2)
Page 14 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
Site Assessment of Existing Conditions:
Vicinity Map: This is on G200
Existing Fence (note 3): The fence is shown on G200, Architectural Site Plan, as
existing or to be replaced to comply with SDC 4.4-110.
Proposed Site Plan (note 3):
Fences: The fence is shown on G200, Architectural Site Plan, as existing or to be
replaced to comply with SDC 4.4-110.
Percentages of site proposed for buildings. structures, parking and vehicular areas,
sidewalks, patios, and other impervious surfaces (note 4): Added to G200
Loading into the restaurant (note 5): This occurs from a truck parked by the trash
enclosure to the delivery door further down by the drive-through ordering. Deliveries
occur in the early morning before traffic starts.
Bicycle facility design (note 6): Drawings have been added to show how it complies
with SDC 4.6-145.
Separate existing and proposed utility plans (note 7): See updated Civil sheets
Show easements related to ultilites (note 8): See updated civil sheets
Any easements related to grading, paving... (note 9): See updated civil sheets
Area of landscaping (note 10): See updated landscape architect sheets
Show 6' fence on landscpaing (note 111: See updated landscape architect sheets
Relocate description of irrigation system to Landscape Plan. (note 12): See updated
landscape architect sheets, specially LA2. We hired a landscape architect to address
these notes and they were not able to physically fit the irrigation notes on LA1.
Street trees (note 13): See updated landscape architect sheets
Proposed tree caliper to be min 2" and shrubs to be 5 gallon (note 14): See updated
landscape architect sheets
This concludes the pre -Submittal Checklist addressing Planning
Additional Materials or Permits
Page 15 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on 8 March 2022
GeoTech report: Please see report from K& A Engineering, Inc., May 9, 2021
Overlay District of Drinking Water Protection IDWPI SDC 3.3-200: Please see civil
drawings
Overlay District of Nodal Development (/NDO) SDC 3.3-1000: A) The minimum FAR
density required by for a MUC zone is 0.4. Our building's gross floor area is 2,915 SF.
The site is 32507. Therefore, our FAR is 2915/32507 = 0.09. B) The maximum setback
is 20 feet, we are proposing 18 feet. C) Due to the odd shape of the site, and
proximity to LDRs, we feel that it is best to have the drive-through exist along the
street buffered by landscaping and a 3' high wall.
In the DIM meeting we discussed these variances for this site redevelopment, and
that we should proceed to this Type II site review submittal phase because the
proposal addressed the spirit of this part of the code for a human scale development
given the odd shape of the lot. Additionally, we addressed the nodal purpose of the
site by proposing the public art's location in the most likely location will it can be
enjoyed by the largest number of people, also immediately adjacent to the bus stop
and pedestrian access to the site.
When it comes time to the public art area's actual design, the firm Dave's Hot
Chicken uses to apply the artwork to the building inside and out can also give us
proposal for the public art using one of their professional artists. Our goal would be
to use as many local elements, textures, and so forth as possible in the public art
area design to reflect the nature and character of the community at large.
Tree Felling Permit: Please see Tree Felling permit
This concludes Additional Materials or Permits for Planning
Land and Drainage Alteration permit: PUBLIC WORKS
Geotech Report (Note1): Please see report from K & A Engineering, Inc., May 9, 2021
Planting Plan (Addl. Comment for note 3): See updated landscape architect sheets.
We hired a landscape architect to address this note and others. Landscape Architect
says:
1. Stormwater facilities have been updated with additional species.
2. Kark F grass is Calamagrostis x acutiflore'Karl Foerster'. Unlike Reed canary grass,
this plant spreads by rhizomes and can become wider over time, but it is not
considered invasive and will not self -seed.
Page 16 of 17
Project Narrative
Dave's Hot Chicken
Date: Sept 27, 2021, Revised 20 January 2022, Added 4.2-105 on H March 2022
Parking lot drainage patterns and area of each basin (Note 2): See civil drawings
Additional details for catch basins and stormwater treatment areas (Note 3): See civil
drawings
Cut/ Fill Amount (Note 4): See civil drawings
This concludes our response.