Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Application APPLICANT 4/8/2022
THE SATRE GROUP Land Use Planners, Landscape Architects, Environmental Specialists 375 West 4th Avenue, Suite 201, Eugene, Oregon 97401 ,,..�..r., (541)686-4540 • www.satregroup.com TRANSMITTAL TO: City of Springfield DATE: April 8, 2022 225 5'^ Street PROJECT: SUB 30 Level Reservoir Springfield, OR 97477 Site Plan Review Pre -Submittal CLIENT PROJ #: ATTN: SG PROJ #: 2140 TRANSMITTED; Herewith DISPOSITION: For Your Approval Separate Cover For Your Information/Use X Other For Reply TRANSMITTED: # Copies Item Dated No. Pages In addition to this cover page) 4 paper copies of a: Site Plan Review Pre -Submittal Application Packet Varies Several REMARKS: This Site Plan Review application packet is hereby submitted for Pre -Submittal. The submittal package includes: 1. This Transmittal 2. Application Fee 3. Application Form 4. Written Statement 5. Deed 6. Title Report 7. Stormwater Scoping Sheet and Stormwater Report 8. Geotechnical Report 9. Reduced Site Plan 10. Plan Set We look forward to your assistance with the project. Don't hesitate to contact us should you have any questions or need any additional information. Thank you. A X IN jCity of Springfield Development Services Department 225 Fifth Street Springfield, OR 97477 Site Plan Review SPRINGFIE�('1, AA Application Type ., - Site Plan Review Pre-Submittal:Ma'or Site Plan Modification Pre -Submittal: ❑ Site Plan Review Submittal: ❑ Ma'or Site Plan Modification Submittal: ❑ Required Project Information (Applicant: complete this section) Applicant Name: Steven Wages, P.E., Project Manager Phone: (541) 726-2396 Company: Springfield Utility Board Email:stevenw@subutil.com Address: 202 South 18th Street, Springfield, OR 97477 Applicant's Rep.: Rick Satre, AICP, ASLA, CSI Phone: (541) 686-4540 Company: The Satre Group Email: rick@satregroup.com Address: 375 W 4th Avenue, Suite 201, Eugene, OR 97401 Property Owner: Springfield Utility Board Phone: (541) 726-2396 Company: Springfield Utility Board Email:stevenw@subutil.com Address: 202 South 18th Street, Springfield, OR 97477 ASSESSOR'S MAP NO: 18-02-03-00 TAX LOT NOS : 302 Property Address: No site address for the Tax Lot Size of Property: 1.77 Acres 0 Square Feet ElProposetl No. of . None Proposed Name of Pro-ect: SUB 3rd Level Reservoir Description of If you are filling in this form by hand, please attach your proposal description to this application. D=.Construct improvements to the SUB 3rd Level Reservoir Pro Existing Use: Water storage reservoir New Irrigiervious Surface Coverage (Including Bldg. Gross Floor Area): sf Si natures: Please si q n and print your name and date in thea ro riate box on the next a e. Required Project Information (City Zntake Staff., complete this section) Associated Applications: Si ns: Pre -Sub Case No.: 1,Z-D6b6 t -per Date: $ ZZ Reviewed by: iL Case No.: I Date: Reviewed b : Application Fee: $ LAIA Technical Fee: $ f2l Postage Fee: TOTAL FEES: $ UlL� - PROJECT NUMBER: BIHq-coo Jpfborr Revised 1/7/14 KL 1 of 11 Owner Signatures This application form is used for both the required pre -submittal meeting and subsequent complete application submittal. Owner signatures are required at both stages in the application process. An application without the Owner's original signature will not be accepted. Pre -Submittal The undersigned acknowledges that the information in this application is correct and accurate for scheduling of the Pre- Submittal Meeting. If the applicant is not the owner, the owner hereby grants permission for the applicant to act in his/her behalf. I/we do hereby acknowledge that I/we are legally responsible for all statutory timelines, information, requests and requirements conveyed to my representative. i Date: Signatbre Print I represent this application to be complete for submittal to the City. Consistent with the completeness check performed on this application at the Pre -Submittal Meeting, I affirm the information Identified by the City as necessary for processing the application is provided herein or the information will not be provided If not otherwise contained within the submittal, and the City may begin processing the application with the information as submitted. This statement serves as written notice pursuant to the requirements of ORS 227.178 pertaining to a complete application. Date: Signature Revised 1/7/14 KL 2 of 11 Site Plan Review Application Process 1. Applicant Submits a Site Plan Review Application for Pre -Submittal • The application must conform to the Site Plan Review Submittal Requirements Checklist on pages 4-7 of this application packet. • A pre -submittal meeting to discuss completeness is mandatory, and pre -submittal meetings are conducted every Tuesday and Friday, from 10:00 am - noon. • Planning Division staff strives to conduct pre -submittal meetings within five to seven working days of receiving an application. 2. Applicant and the City Conduct the Pre -Submittal Meeting • The applicant, owner, and design team are strongly encouraged to attend the pre - submittal meeting. • The meeting is held with representatives from Public Works Engineering and Transportation, Community Services (Building), Fire Marshall's office, and the Planning Division and is scheduled for 30 to 60 minutes. • The Planner provides the applicant with a Pre -Submittal Checklist specifying the items required to make the application complete if it is not already complete, and the applicant has 180 days submit a complete application to the City. 3. Applicant Submits a Complete Application, City Staff Review the Application and Issue a Decision • A complete application must conform to the Site Plan Review Submittal Requirements Checklist on pages 4-7 of this application packet. • A Type II decision, made after public notice, but without a public hearing, unless appealed, is issued within 120 days of submittal of a complete application. • Mailed notice is provided to property owners and occupants within 300 feet of the property being reviewed and to any applicable neighborhood association. In addition, the applicant must post one sign, provided by the City, on the subject property. • There is a 14 -day public comment period, starting on the date notice is mailed. • Applications are distributed to the Development Review Committee, and their comments are incorporated into a decision that addresses all applicable approval criteria and/or development standards, as well as any written comments from those given notice. • Applications may be approved, approved with conditions, or denied. • At the applicant's request, the Planner can provide a copy of the draft land use decision prior to issuing the final land use decision. • The City mails the applicant and any party of standing a copy of the decision, which is effective on the day it is mailed. • The decision issued is the final decision of the City but may be appealed within 15 calendar days to the Planning Commission or Hearings Oficial. Revised 1/7/14 KL 3 of 11 Site Plan Review Submittal Requirements Checklist NOTE: • ALL of the following items MUST be submitted for BOTH Pre -Submittal and Submittal. • If you feel an item on the list below does not apply to your specific application, please state the reason why and attach the explanation to this form. [1 Application Fee - refer to the Development Code Fee Schedule for the appropriate fee calculation formula. A copy of the fee schedule is available at the Development Services Department. Any applicable application, technology, and postage fees are collected at the pre -submittal and submittal stages. Q Site Plan Review Application Form W Narrative explaining the purpose of the proposed development, the existing use of the property, and any additional information that may have a bearing in determining the action to be taken. The narrative should also include the proposed number of employees and future expansion plans, if known. Density - if applicable, list the size of property (acres), maximum allowable density and the density proposed. Q Copy of the Deed 0 Copy of the Site Plan Reduced to S+/z"x 11", which will be mailed as part of the required neighboring property notification packet. N/A ❑ State or Federal Permits Required - The applicant must demonstrate that an application has been submitted for any required federal or state permit and provide a copy of the application upon request. W Completed Attached Scoping Sheet Four (4) Copies of the Following Plan Sets for Pre -Submittal OR Four (4) Copies of the Following Plan Sets for Submittal: All of the following plans must include the scale appropriate to the area involved and sufficient to show detail of the plan and related data, north arrow, and date of preparation. All plan sets must be folded to 8'/2" by 11" and bound by rubber bands. Please Note: • These plans must provide enough information to enable the City to determine that the proposed development is feasible, but are not necessarily required to be detailed construction level documents. • The City's Engineering Design Standards Manual, while not land use criteria, may be used in whole or in part, by the City Engineer to determine the feasibility of a proposed plan. • Nothing herein should be interpreted as implying any requirement in contradiction of Oregon Statute or Oregon Administrative Regulation. Revised 1/7/14 KL 4 of 11 a. Site Assessment of Existing Conditions © Prepared by an Oregon licensed Architect, Landscape Architect, Civil Engineer or Surveyor Vicinity Map The name, location and dimensions of all existing site features including buildings, curb cuts, trees and impervious surface areas, clearly indicating what is remaining and what is being removed. For existing structures to remain, also indicate present use, size, setbacks from property lines, and distance between buildings. N/A F1 The name, location, dimensions, direction of flow and top of bank of all watercourses and required riparian setback that are shown on the Water Quality Limited Watercourse Map on file in the Development Services Department N/A❑ The 100 -year floodplain and floodway boundaries on the site, as specified in the latest adopted FEMA Flood Insurance Rate Maps or FEMA approved Letter of Map Amendment or Letter of Map Revision N/A ❑ The Time of Travel Zones, as specified in SDC 3.3-200 and delineated on the Wellhead Protection Areas Map on file in the Development Services Department © Physical features including, but not limited to trees 5" in diameter or greater when measured 4 1/1 feet above the ground (stands of more than five (5) trees may be shown as a cluster with mix of trees species noted), riparian areas, wetlands and rock outcroppings b. Site Plan Prepared by an Oregon licensed Architect, Landscape Architect, Civil Engineer or Surveyor Proposed buildings: location, dimensions, size (gross floor area applicable to the parking requirement for the proposed use(s)), setbacks from property lines, and distance between buildings; measured setbacks shall be prepared by an Oregon licensed Surveyor when minimum setbacks are shown. © Location and height of existing or proposed fences, walls, outdoor equipment, storage, trash receptacles, and signs N/A ❑ Location, dimensions, and number of typical, compact and ADA parking spaces; including aisles, wheel bumpers, directional signs, and striping. ADA routes from public rights-of-way whall be designated including at grade connections 91 Dimensions of the development area, as well as area and percentage of the site proposed for buildings, structures, parking and vehicular areas, sidewalks, patios, and other impervious surfaces N/A F-] Observance of solar access requirements as specified in the applicable zoning district 21 On-site loading areas and vehicular and pedestrian circulation W1 Access to streets, alleys, and properties to be served, including the location and dimensions of existing and proposed curb cuts and curb cuts proposed to be closed N/A❑ Location, type, and number of bicycle parking spaces N/A❑ Note location of existing and planned Lane Transit District facilities (within 1/2 mile) Revised 1/7/14 KL 5 of 11 N/A❑ Area and dimensions of all property to be conveyed, dedicated, or reserved for common open spaces, recreational areas, and other similar public and semi-public uses N/A ❑ Phased Development Plan — where applicable, the Site Plan application must include a phasing plan indicating any proposed phases for development, including the boundaries and sequencing of each phase. Phasing must progress in a defined sequence addressing street connectivity between the various phases and accommodating the logical extension of other required public improvements, including but to limited to, sanitary sewer, stormwater management, water and electricity. The applicant must clearly indicate which phases are proposed for approval under the current Site Plan application and which are deferred to future review procedures. c. Existing Improvement and Public Utilities Plan Prepared by an Oregon licensed Architect, Landscape Architect, Civil Engineer or Surveyor Location and width of all existing easements Location, widths (of paving and right-of-way), and names of all existing streets, alleys, dedications or other right-of-ways within or adjacent to the proposed development, including jurisdictional status other than City. Indicate connection points for roof drainage. Location and type of existing street lighting Location of existing and required traffic control devices, fire hydrants, power poles, transformers, neighborhood mailbox units, waterline backflow preventers and similar public facilities Location, width, and construction material of all existing and proposed sidewalks, sidewalk ramps, pedestrian access ways, and trails © Location and size of existing utilities on and adjacent to the site including sanitary sewer mains, stormwater management systems, water mains, power, gas, telephone, and cable N. Indicate the proposed connection points. Detail must be proportionate to the complexity of the proposed project. Show existing and proposed spot elevations or contours, and direction of drainage patterns. d. Proposed Grading, Paving, & Utilities Plan © Prepared by an Oregon licensed Civil Engineer, except where noted below The approximate size and location of storm water management systems components N/A F-1 Location, widths (of paving and right-of-way), and names of proposed streets, alleys, dedications or other rights -of -ways within or adjacent to the proposed development © Location and width of all proposed easements N/A ❑ Location and type of proposed street lighting Information on existing slopes over 5% shall be prepared by an Oregon licensed surveyor and be drawn with one foot contour interval lines; land with a slope over 10 percent shall be shown with 5 foot contour interval lines Revised 1/7/14 KL 6 of 11 e. Landscape Plan N/A ❑ Prepared by an Architect, Landscape Architect, or other Landscape Professional approved by the Director N/A ❑ Location and dimensions of landscaping and open space areas to include calculation of landscape coverage N/A ❑ Where applicable, screening in accordance with SDC 4.4-110 N/A ❑ Location of existing and proposed street trees f. Architectural Plans V Where abutting residentially zoned properties, exterior elevations of all proposed structures over 140 square feet for the development site, including height, shall be shown g. On -Site Lighting Plan V Location, orientation, and maximum height of exterior light fixtures, both free standing and attached Type and extent of shielding, including cut-off angles, and type of illumination, wattage, and luminous area Additional Materials That May be Deferred at the discretion of the applicant until Final Site Plan or Building Permit Submittal: N/A ❑ List in chart form the proposed types of landscape materials (trees, shrubs, ground cover). Include in the chart genus, species, common name, quantity, size and spacing N/A ❑ Where plants are proposed as part of the stormwater management system, a planting plan shall be provided. N/A❑ Irrigation Plan showing of irrigation lines, required backflow preventers and above ground utilities. [A Photometric test report for each light source. [.� An applicant may submit conceptual floor plans in order to have staff address Resolution of potential nuisance conflicts Additional Materials That May be Required by the Director: IT IS THE APPLICANT'S RESPONSIBILITY TO DETERMINE IF ADDITIONAL STANDARDS/APPLICATIONS APPLY TO THE PROPOSED DEVELOPMENT. THE APPLICANT SHOULD CONSIDER UTILIZING PRE -DEVELOPMENT MEETINGS AS DISCUSSED IN SDC 5.1-120: Copy of a Preliminary Title Report issued within the past 30 days documenting ownership and listing all encumbrances. N/A F-1 A developer may be required to prepare a Traffic Impact Study (TIS) to identify potential traffic impacts from proposed development and needed mitigation measures. Revised 1/7/14 KL 7 of 11 N/A ❑ Where a multi -family development is proposed, any additional materials to demonstrate compliance with SDC 3.2-240 N/A ❑ Riparian Area Protection Report for properties located within 150 feet of the top of bank of any Water Quality Limited Watercourses (WQLW) or within 100 feet of the top of bank of any direct tributaries of WQLW A Geotechnical Report prepared by an engineer must be submitted concurrently if the Soils Survey indicates the proposed development area has unstable soils and/or a high water table, or if required by the City Engineer Where the development area is within an overlay district, address the additional standards of the overlay district on plans and narratives [� Where physical aspects of a proposed development, including but not limited to scale, odor noise, glare or vibration, will impact less intensive surrounding uses, the Director may request submittal of conceptual floor plans or other information necessary to determine compliance with applicable standards. [� If five or more trees are proposed to be removed, a Tree Felling Permit as specified in SDC 5.19-100 N/A ❑ A wetland delineation approved by the Oregon Division of State Lands must be submitted concurrently where there is a wetland on the property N/A ❑ The applicant must demonstrate that an application has been submitted for any required federal or state permit and provide a copy of the application upon request 0 Where any grading, filling or excavating is proposed with the development, a Land and Drainage Alteration permit must be submitted prior to development N/A ❑ Where applicable, any Discretionary Use or Variance as specified in SDC 5.9-100 and 5.21-100 46 An Annexation shall be submitted prior to submission of application, as specified In SDC 5.7-100, where a development is proposed outside of the city limits but within the City's urban service area and can be served by sanitary sewer Revised 1/7/14 KL 8 of 11 April 7, 2022 SPRINGFIELD UTILITY BOARD SOUTH HILLS 3RD LEVEL RESERVOIR REPLACEMENT Site Plan Review Map 18-02-03-00, Lot 302 WRITTEN STATEMENT In accordance with Site Plan Review submittal requirements, this written statement describes the proposed development and demonstrates that the proposal complies with the standards and criteria contained in SDC 5.17-100 through 5.17-125. LAND USE REQUEST A. Development Objective The development objective for the existing reservoir site is threefold. One, to continue serving as a water storage reservoir site; two, the construction of a new, second water storage reservoir, and three the demolition and replacement of the existing water storage reservoir. Subject Property RLID Maps 2022 B. Project Directory Owner/Applicant Steven Wages Springfield Utility Board 202 South 18tr Street Springfield, OR 97477 Phone: (541) 726-2396 Email: stevenw(rasubutil.com PlannerlLandscaoe Architect (and Applicant's Representative) Rick Satre, AICP, ASLA, CSI The Satre Group 375 West 4" Avenue, Suite 201 Eugene, OR 97401 Phone: (541) 686-4540 Email: rickasatregrouo.com Surveyor Dan Nelson, PLS Branch Engineering, Inc 310 5'N Street Springfield, OR 97477 Phone: (541) 746-0637 Email: dann@branchengineering.com PLANNERS - IANeSCAPEASCNITECTS - ENVIRONMENTAL SPECIALISTS 375 West 4th, Suite 201, Eugene, OR 97401 Phone: 541.686.4540 www.satregroup.com Springfield Utility Board— South Hills 3'd Level Reservoir Replacement Page 2 of 13 Site Plan Review Map 18-02-03-00, Lot 302 Civil Engineer Tom Boland, P.E. Murraysmith, Inc. 888 SW 5th Avenue, Suite 1170 Portland, OR 97204 Phone: (503) 225-9010 Email: Tom.Boland(rilmurraysmith.us THE SITE AND EXISTING CONDITIONS A. Development Site The To Level Reservoir site is located at South 661, Place and Jessica Drive in the Thurston Hills of Springfield. The reservoir site is partially forested and is approximately 1.77 acres in size. Access is by way of a graveled drive (part of an existing variable width access and utility easement) extending from South 66th Place. Abutting the site to the north, south and east is unimproved land which is planned and zoned for low density residential development. The 3'^ Level Reservoir is outside Springfield city limits (annexation agreement is underway in a separate process). B. Planning Context 1. Planning and Zoning Local long-range land use is governed by the t �.•� 2 4 Eugene -Springfield Metropolitan Area General Plan (Metro Plan), often supplemented with a 2 more specific refinement plan and/or i !� neighborhood plan, followed by site-specific zoning. Further, zoning can sometimes be comprised of base and overlay zoning. For the reservoir site, the Metro Plan designation is Low Density Residential, there is no applicable neighborhood plan, and the base zoning is Low Density Residential. C__, SpringFleld zoning Map September2018 2. Transportation a. TransPlan. The metro area adopted transportation plan, The Eugene -Springfield Transportation System Plan (TransPlan), adopted in 2001 and amended in 2002, includes one project in the vicinity of the subject property — Project 36, a future collector connecting Straub Parkway to the west to the general vicinity of the south side of MountainGate Master Plan area. b. Springfield 2035 Transportation System Plan. The City of Springfield's Local Street Network f J diagram shows proposed future streets within Springfield's jurisdiction. The plan is illustrative only Ij and is not parcel specific. Future local streets, their locations and connection points can be adjusted at ✓i time of specific development proposals. None of the — future streets affect the subject property. Local Street Network Map Excerpt 1 y City of Springfield August 2018 The Satre Group • 375 West 4" Avenue, Suite 201, Eugene, OR 97401 • (541) 686-4540 • www.satregmup.cpm Springfield Utility Board — South Hills 3'° Level Reservoir Replacement Page 3 of 13 Site Plan Review Map 18-02-03-00, Lot 302 April 7. 2022 c. Public Transit. There is no public transit service in the vicinity of the reservoir site. 3. Utilities a. Stormwater and Wastewater. The Springfield Stormwater Facilities MasterPlan shows the property as being within the Weyerhaeuser Basin. The Master Plan identifies no capital improvement projects in the vicinity of the project. The site has both stormwater and sanitary infrastructure adjacent to the property in both South 66'h Place and Jessica Drive. Stormwater Facilities Master Plan City of Springfield, Calabar 2008 It. Wellhead Protection. The subject property is not within a wellhead protection area, nor are there any protection areas near the subject property. Wellhead Protection Areas Map Except City of Springfield and Springfield Utility Board January 2013 c. Water & Electric. Existing water and electric infrastructure exist on and adjacent to the subject site. I$ Existing Water Infrastructure Existing Electric Infrastructure Springfield Utility Boats, 2021 Springfield Utility Board, 2021 The Satre Group • 375 West 0 Avenue, Suite 201, Eugene, OR 97401 • (541) 686-4540 • www.setieorouo.com Springfield Utility Board - South Hills 3'd Level Reservoir Replacement Site Plan Review Map 18-02-03-00, Lot 302 e. Utility Easements Page 4 of 13 A variable width private access r easement exists on and utility wo m the SUB reservoir site. The M. Po. easement (Lane County Deeds In and Records 2007-020544) is for y3 „L_ "1d' a water line and private access and private utilities. There is also I 8 a 10 -foot -wide public utility easement along the east side of I ',,, ,1774 3 , South 66n Place and the north: .---_' side of Jessica Drive abutting the�` syy. reservoir site. 'Y 4. Natural Resources a. Springfield Natural Resources Study. The Springfield Natural Resource Study Report does not identify any resources on or near the site that would be impacted by the proposed development. b. Springfield Wetland Inventory I Water Quality Limited Watercourses (WQLW). Neither the National Wetlands Inventory nor the Local Wetlands Inventory document the presence of jurisdictional wetlands on or adjacent to the subject property. Springfield's Water Quality Limited Watercourses inventory also documents that there are no WQLW features on or adjacent to the subject property. c. Geotechnical Stability. Two Geotechnical Reconnaissance reports were generated for the existing SUB Reservoir Site in 2013. The second report, Supplemental Geotechnical Investigation, dated November 18, 2013, States that three exploratory boreholes were drilled at the site and includes the following conclusion on page 7. "SUMMARY AND CONCLUSIONS. The slope stability analyses indicate the reservoir site is relatively stable for both static and seismic conditions based on the estimated soil strength parameters. Therefore, we believe the risk of slope instability is low. Certain factors could still affect the stability of the site, including future development of the surrounding area and other factors that influence groundwater conditions. In addition as with any development within landslide terrain, some risk of instability, though minor, still remains." ir�✓{\> rr. Borehole Map South Hills Reservoir Supplemental Geotechnical Investigation November 18, 2013 The Satre Group • 375 West 4'" Avenue, Suite 201, Eugene, OR 97401 • (541) 6863540 • w satre trouo.eem Springfield Utility Board — South Hills 3rd Level Reservoir Replacement Site Plan Review Map 18-02-03-00, Lot 302 5. Parks and Open Space a. Willamalane Park and Recreation Compreh The Willamalane Comprehensive Plan includes three projects within the vicinity of the reservoir site. Page 5 of 13 Project 3.8. Pursue acquisition and development of natural area parks and trail t systems along the Thurston Hills ridgeline -- south of Potato Hill and towards the Jasper- 1,j i,# Natron area. (Completed. See Project 4.10.) # �-1 Project 3.10. Identified in the MountainGate Master Plan, develop a 90 -acre natural area park and trail system on top of Potato Hill. Project 4.10. Acquisition and development of a ridgeline trail in the south Thurston Hills area. (Property has since been acquired. The portion immediately southeast of the reservoir site has been identified by Willamalane as a Community Forest. Development of a trail system is underway.) III. SITE PLAN REVIEW— APPROVAL CRITERIA AND FINDINGS This section is presented in the same order of applicable requirements found in Section 5.17-125, Site Plan Review Criteria of the Springfield Development Code. Applicable sections of the Code are in bold italics, followed by proposed findings in normal tela. A. The zoning is consistent with the Metro Plan diagram, and/or the applicable Refinement Plan diagram, Plan District map, and Conceptual Development Plan. Response: There is no applicable Plan District Map, Conceptual Development Plan, or Refinement Plan for the subject property. The zoning is consistent with the Metro Plan Diagram. The subject property is zoned Low Density Residential and has a Metro Plan designation of Low Density Residential. Metro Plan Diagram 2010 Regarding the Eugene -Springfield Public Facilities and Services Plan, the development proposal is consistent with the following Plan's policies: The Satre Group • 375 West 4" Avenue, Suite 201, Eugene, OR 97401 • (W) 6664540 • w .satreorouo.cam jit 5 MThursWn Hills Park and Recreation Projects Map Excerpt Willamalane Park and Recreation District October 2012 III. SITE PLAN REVIEW— APPROVAL CRITERIA AND FINDINGS This section is presented in the same order of applicable requirements found in Section 5.17-125, Site Plan Review Criteria of the Springfield Development Code. Applicable sections of the Code are in bold italics, followed by proposed findings in normal tela. A. The zoning is consistent with the Metro Plan diagram, and/or the applicable Refinement Plan diagram, Plan District map, and Conceptual Development Plan. Response: There is no applicable Plan District Map, Conceptual Development Plan, or Refinement Plan for the subject property. The zoning is consistent with the Metro Plan Diagram. The subject property is zoned Low Density Residential and has a Metro Plan designation of Low Density Residential. Metro Plan Diagram 2010 Regarding the Eugene -Springfield Public Facilities and Services Plan, the development proposal is consistent with the following Plan's policies: The Satre Group • 375 West 4" Avenue, Suite 201, Eugene, OR 97401 • (W) 6664540 • w .satreorouo.cam Springfield Utility Board - South Hills 3" Level Reservoir Replacement Page 6 of 13 Site Plan Review Map 18-02-03-00, Lot 302 The Public Facilities and Services Plan states that SUB will "add upper-level reservoir(s) for the 3'd 4'h, and 5th level". Special Development Standards for High Impact Public Facilities (SDC 4.7-160 A.) indicates that Discretionary Use is not required if the facility is designated on the Public Facilities and Services Plan. The 3'" Level Reservoir Site is considered a Hight Impact Public Facility per SDC 6.1-110 and is listed on the Public Facilities and Services Plan. Eugene -Springfield Public Facilities and Services Plan December 31, 2011 B. Capacity requirements of public and private facilities, including, but not limited to, water and electricity; sanitary sewer and stormwater management facilities; and streets and traffic safety controls shall not be exceeded and the public improvements shall be available to serve the site at the time of development, unless otherwise provided for by this Code and other applicable regulations. The Public Works Director ora utility provider shall determine capacity issues. Response: The site is a proposed public utility facility. It is not and will not be inhabited with any dwelling units, offices or other buildings regularly occupied by people. There is no need for the full suite of utility facilities. Nonetheless, public and private facilities are provided as follows: Storm: Public stormwater infrastructure exists in South 66'^ Place and Jessica Drive adjacent to the subject property. Sanitary: Sanitary infrastructure is adjacent to the site in South 66'^ Place and Jessica Drive. Water: Water infrastructure is available on site. Electric: Electric infrastructure is adjacent to the site in South 66ta Place and Jessica Drive. Streets: South 66t, Place and Jessica Drive are local streets per the TSP. ROW has been dedicated along the Tax Lots. C. The proposed development shall comply with all applicable public and private design and construction standards contained in this Code and other applicable regulations. SDC CHAPTER 3 LAND USE DISTRICTS (Portions applicable to all six tax lots) 1. SDC 3.2-210 Residential Zoning Districts Base Zone Development Standards As a High Impact Public Utility Facility, the proposed reservoir is permitted in the Low Density Residential zone subject to approval of a Site Plan Review application and compliance with special standards in Section 4.7-160. SDC 4.7-160 addresses High Impact Public Utility Facilities and includes the following standards: A. The facility shall be designated on the Metro Plan's Public Facilities and Services Plan or be approved in accordance with a Type l/I review procedure (Discretionary Use). Response: The V Level Reservoir is on the Public Facilities and Services Plan. The Satre Group •375 West 4'" Avenue, Suite 201, Eugene, OR 97401•(541) 686-4540•v wsatrecroup.wm Springfield Utility Board - South Hills 31d Level Reservoir Replacement Page 7 of 13 Site Plan Review Map 18-02-03-00, Lot 302 B. The facility shall be screened as specified in Section 4.4-100. Response: The facility is screened from Jessica Drive and South 66th Place. See response to 4.4-100 below. C. In residential districts, a minimum of 25 percent of the lollparcel shall be landscaped. Response: The facility is landscaped. See 4.4-100 below. 2. SDC 3.2-215 Base Zone Development Standards Response: Base Zone Development Standards applicable to the application include Lot Coverage and Setbacks. The Lot Coverage Standard is a Maximum Coverage of 35 percent, inclusive of structures and paved area. The project area is 1.77 acres, or 77,101 square feet. See sheet C-2 for new impervious area. The Setback Standards is 10 feet for front, street side and rear yards and 5 feet for interior yards. Proposed setbacks exceed those minimum setbacks. (See Plan Set.) SDC 3.3-500 HILLSIDE DEVELOPMENT OVERLAY DISTRICT (Applicable to all six tax lots as portions of each of the six lots has some area over 15% slope) 1. SDC 3.3-510 Applicability The HD Overlay District is applied in residential zoning districts above 670 feet elevation or to development areas below 670 feet in elevation where any portion of the development area exceeds 15 percent slope as determined using the slope calculation described in Subsection 3.3-520A. Response: Portions of the development site exceed 15 percent slopes. Therefore, the HD Overlay District applies. See Hillside Development Overlay District application submitted concurrently with this application. SDC CHAPTER 4 DEVELOPMENT STANDARDS (Applicable to all six tax lots) SDC 4.2-120 Site Access and Driveways A. Site Access and Driveways - General. 1. All developed lots/parcels shall have an approved access provided by either direct access to a: a. Public street or alley along the frontage of the property; b. Private street that connects to the public street system; c. Public street by an irrevocable joint use/access easement serving the subject property that has been approved by the City Attorney, where: I. A private driveway is required in lieu of a panhandle driveway; or fl. Combined access for 2 or more lots1parcels is required to reduce the number of driveways along a street. Response: The subject property receives direct access from South W Place (a public street) by an existing variable width access and utility easement serving the subject property. The easement is for the benefit of Tax Lots 6000, 6100, 6200, 6400, 6500, and The Satre Group -375 West 4th Avenue Suite 201, Eugene, OR 97401•(541) 666-4540-w satraorouo.com Springfield Utility Board — South Hills V Level Reservoir Replacement Page 8 of 13 Site Plan Review Map 18-02-03-00, Lot 302 April7.2O22 SUB and exists to grant an easement for a water line, private access and private utilities over and across the above-mentioned Tax Lots. B. Driveway access to local streets is generally encouraged in preference to streets of higher classification. Response: The subject property fronts local streets South 66th Place and Jessica Drive. The 3' Level Reservoir takes access from South 66th Place via the variable width access and utility easement noted above. C. Driveways shall be designed to allow safe and efficient vehicular ingress and egress as specified in Tables 4.2-2 through 4.2-4 and the City's Engineering Design Standards and Procedures Manual and the Public Works Standard Construction Specifications. SDC Table 4.2-2 Driveway Design Specifications 2 -Way Driveway Width - Industrial Required: 24 feet minimum, 35 feet maximum. Transition Width Required: 8 feet minimum, no maximum. Driveway Throat Depth Required: 18 feet Response: There is an existing curb cut and driveway on the boundary between Tax Lots 6100 and 6200; this driveway connects to a private access and utility easement and provides access to the 31' Level Reservoir. The driveway has an 8' minimum transition width and a paved throat depth of 18 feet (the first 18 feet of the driveway is paved in accordance with SDC Table 4.2.2, Footnote 3). SDC Table 4.2-3 Curt Return Driveway Design Specifications Response: The driveway does not include a curb -return. Thus, this criterion does not apply. SDC Table 4.2-4 Minimum Separations between a Driveway and the Nearest Intersection Curb Return on the Same Side of the Street` Multifamily Residential Required. Local Street. 150 feet. Response: The driveway does not include a curb -return. Thus, this criterion does not apply. 2. SDC4.2425 Intersections Intersections shall be designed and constructed as specified in the City's Engineering Design Standards and Procedures Manual and the following requirements. A. In order to minimize traffic conflicts and provide for efficient traffic signalization, intersections involving curb return driveways and streets, whether public or private, shall be directly opposed, unless a Traffic Impact Study indicates that an offset intersection benefits public safety to a greater degree. Response: The proposed development does not include a curb return driveway. B. Streets shall be laid out so as to intersect as nearly as possible at right angles. The angle of intersection between 2 intersecting streets shall be at least 80 degrees. At intersections, each local street shall be straight or have a radius The Satre Group • 375 West 4th Avenue, Suite 201, Eugene, OR 97401 - (541) 686-4540 • v satrearoup.cam Springfield Utility Board — South Hills 3'u Level Reservoir Replacement Page 9 of 13 Site Plan Review Map 18-02-03-00, Lot 302 greater than 400 feet for a distance of 100 feet from each intersection. At intersections, each collector or arterial street shall be straight or have a radius greater than 600 feet for a distance of 100 feet from each intersection. Response: The application does not propose any new streets. 3. SDC 4.2-130 Vision Clearance A. All corner lots/parcels shall maintain a clear area at each access to a public street.... Response: The proposed development area includes a corner lottparcel. No screen or physical obstruction will be placed in the 2 % by 8' vertical vision clearance area in the 10' by 10' vision clearance triangle at the driveways on Tax Lot 6100 and 6200. No screen or physical obstruction will be placed in the 2 % by 8' vertical vision clearance area in the 25' by 25' vision clearance triangle at the street corner on Tax Lot 6200. SDC 4.2-135 Sidewalks A. Sidewalks and planter strips abutting public streets shall be located wholly within the public street right-of-way, unless otherwise approved by the Public Works Director. B. Sidewalks shall be designed, constructed, replaced or repaired as specified in the City's Engineering Design Standards and Procedures Manual, the Public Works Standard Construction Specifications and the Springfield Municipal Code, 1997. New sidewalk design shall be consistent with existing sidewalk design in the same block in relation to width and type C. Planter strips may be required as part of sidewalk construction. Planterstrips shall be at least 4.5 feet wide and long enough to allow the tree to survive. Maximum planter strip width is dependent upon the type of tree selected as specified in the City's Engineering Design Standards and Procedures Manual. Response: The 31° Level Reservoir has existing street frontage on Jessica Drive. A curb- side sidewalk was constructed along the pump station frontage on 66th at the time the pump station was constructed. No additional sidewalk is proposed. 5. SDC 4.2.140 Street Trees B. Existing street trees are to be retained. If removed, they must have a permit to do so and be replaced with a new tree. Response: are no existing street trees along either South 66'" Place or Jessica Drive. None will be removed. SDC 4.2-145 Street Lighting Public street lighting design and placement is specified In the City's Engineering Design Standards and Procedures Manual and the Public Works Standard Construction Specifications and Is approved by the Public Works Director. A. Street Lighting shall be included with all new developments or redevelopment. Existing street lights shall be upgraded to current lighting standards with all new developments or redevelopment as determined by the Public Works Director. The developer is responsible for street lighting installation costs. Response: South 66th Place and Jessica Drive are improved with a paved roadway, curb and gutter and streetlights. Sidewalk and landscaped strip also exist along the pump station frontage. As streetlights exist, this standard is met. The Satre Group - 375 West 4'" Avenue, Suite 201, Eugene, OR 97401 - (541) 6864540-www.satreorouo.com Springfield Utility Board - South Hills V Level Reservoir Replacement Page 10 of 13 Site Plan Review Map 18-02-03-00, Lot 302 7. SDC 4.3-105 Sanitary Sewers A. Sanitary sewers shall be installed to serve each new development within the city limits and to connect developments to existing mains... Response: Existing sanitary infrastructure exists in South 66n Place and Jessica Drive. Thus, sanitary sewer service is available to the subject property. (Although service is available, the proposed development does not need sanitary service and does not plan to extend service into the site.) 8. SDC 4.3-110 Stormwater Management B. The approval authority shall grant development approval only where adequate public and/or private stormwater management system provisions have been made as determined by the Public Works Director, consistent with the policies set forth in the Stormwater Management Plan and the Engineering Design Standards and Procedures Manual. The stormwater management system shall be separated from any sanitary sewer system. Surface water drainage patterns shall be addressed on every Preliminary Site Plan, Tentative Partition or Subdivision Plan. C. A stormwater management system shall accommodate potential run-off from its entire upstream drainage area, whether inside or outside the development. The Public Works Director shall determine the necessary size of the facility, based on adopted Public Facility Plans and Stormwater Facility Master Plans. The developer shall pay a proportional share of the cost according to adopted City Council policy. D. Run-off from a development shall be directed to an approved stormwater management system with sufficient capacity to accept the discharge. Where the Public Works Director determines that additional run-off resulting from the development will overload an existing stormwater management system, the Approval Authority shall withhold Development Approval until provisions, consistent with the Engineering Design Standards and Procedures manual, have been made to correct or mitigate the condition. Response: There is existing stormwater infrastructure in South 661h Place and Jessica Drive. An on-site stormwater collection system will be constructed. Any additional stormwater runoff from the development site to the existing system will not exceed the carrying capacity of the system. See accompanying Stormwater Management Plan and plan set for additional information. E. Any development with a stormwater threshold management requirement of 1,000 square feet of impervious surface area shall be required to employ stormwater management practices consistent with the Springfield Engineering Design Standards and Procedures Manual, which minimize the amount and rate of surface water runoff into receiving streams. Response: The onsite stormwater system will include stormwater management practices consistent with the Springfield Engineering Design Standards and Procedures Manual. See accompanying Stormwater Management Plan and plan set for additional information. F. Identification of Water Quality Limited Watercourses. Response: There are no Water Quality Limited Watercourses on the development site. Therefore, this standard does not apply. G. Protection of Riparian Area Functions. Response: There are no Water Quality Limited Watercourses on the development site, therefore there are no riparian areas to protect. This standard does not apply. The Satre Group • 375 West 41' Avenue, Suite 201, Eugene, OR 97401 • (541) 6864540 •www satrearauo.com Springfield Utility Board - South Hills V Level Reservoir Replacement Page 11 of 13 Site Plan Review Map 18-02-03-00, Lot 302 9. SDC 4.3-125 Underground Placement of Utilities; and SDC 4.3-130 Water Service and Fire Protection Response: New utilities associated with the project will be placed underground. Water services is available from South 661h Place and Jessica Drive. An existing fire hydrant is located on the north side of Jessica near the southwest corner of the 3" Level Reservoir. 10. SDC 4.3-140 Public Easements A. Utility Easements. The applicant shall make arrangements with the City and each utility provider for the dedication of utility easements necessary to fully service the development or land beyond the development area as necessary. The minimum width for public utility easements adjacent to street rights-of-way shall be 7 feet. The minimum width for all other public utility easements shall also be 7 feet. However, the utility provider or the Public Works Director may require a larger easement for major water mains, major electric power transmission lines... or in any other situation to allow maintenance vehicles to set up and perform the required maintenance or to accommodate multiple utility lines. Where feasible, utility easements shall be centered on a lotlparcel line. Response: A number of easements are already in existence related to the subject property and proposed project. Should additional easements be required, the applicant shall make arrangements as needed. 11. SDC 4.4-105 Landscaping A. Three types of landscaping may be required., 1. Landscaping standards for private property as specified in this Section and other Sections of this Code. 2. Street trees in the public right-of-way as specified in Section 4.2-140. 3. Curbside planter strips in the public right-of-way as specified in 4.2-135. B. Unless otherwise specified in this Code all required setback areas and parking lot planting areas shall be landscaped. Response: Required setbacks include 10 feet at the front lot line for buildings and 5 feet at front, interior side and rear yards for parking, driveway and outdoor storage. These setback areas are already landscaped (i.e., at the recently constructed pump station) or are landscaped with existing hillside vegetation. (See Plan Set.) Interior to the 3' Level Reservoir site, there will be some disturbed areas as the proposed reservoir and utility infrastructure is constructed. These areas will be landscaped with meadow grass that is drought resistant and does not need irrigation. A minimum of 65 of required planting areas will be covered with living plant material within 5 years of installation. There will be some areas of tree removal. See Tree Felling Plan (Sheet TF1.0). These will be interior to the site, where the reservoir will be constructed. Existing trees along street frontage to the south and west and along the adjacent property to the north and east will remain. 12. SDC 4.4.110 Screening; and SDC 4.4-115 Fencing A. Screening shall be required 1. Where commercial and industrial districts abut residential districts and no approved screening exists; 2. For outdoor mechanical devices and minor and major public facilities; 3. For outdoor storage areas abutting residential districts; 4. For trash receptacles. The Satre Group - 375 West 4'" Avenue, Suite 201, Eugene, OR 97401 • (541) 686-4540 • v satreoroup.com Springfield Utility Board - South Hills 3b Level Reservoir Replacement Page 12 of 13 Site Plan Review Map 18-02-03-00, Lot 302 April 7 2022 Response: The development is in a residential district. There are no proposed outdoor mechanical devices. There are no outdoor storage yards or areas. There are no trash receptacles. The recently constructed pump station was screened to meet this standard. Improvements associated with this application are either underground or are screened with existing vegetation. B. Screening shall be vegetative, earthen and/or structural and be designed to minimize visual and audible incompatible uses from adjacent properties... 1. Structural screening shall be a fence or masonry wall constructed to provide a uniform sight -obscuring screen. Response: A 6' tall chain link fence with 3 strands of barbed wire surrounds the perimeter of the 30 level reservoir site; the chain-link fence is black powder -coated chain link. Existing trees, shrubs, and landscaping provide screening along the Jessica Drive right-of-way and the north property line of the pump station site, between the subject property and the adjacent residential property. Existing hillside vegetation between the proposed improvements and the residential property will remain and continue to serve as screening. 13. SDC 4.5.100 On -Site Lighting Standards; and SOC 4.5-110 Illumination and Height A. On-site lighting shall be the minimum illumination necessary for a given application including parking areas and vehicle sales areas. All exterior light fixtures shall be shielded or recessed so that direct glare and reflection are contained within the boundaries of the property, and directed downward and away from abutting properties; public rights-of-way; and riparian, wetlands and other protected areas identified in this Code on the same property. B. Height. 1. The height of a freestanding exterior light fixture shall not exceed 25 feet or the height of the principal permitted structure, whichever is less. In this case, height is measured as the vertical distance between the paved surface and the bottom of the light fixture. Response: On-site lighting will be limited to wall mounted light fixtures attached to the reservoir(s). (See Plan Set.) 14. SDC 4.6-100 Vehicle Parking, Loading and Bicycle Standards. Response: The proposal will meet the standards of Section 4.6-105 through 4.6-125 Vehicle Parking, Section 4.6-130 through 4.6-135 Loading Areas and Section 4.6-140 through 4.6- 156 Bicycle Parking. • Section 4.6-105 through 4.6-125 Vehicle Parking — This is a major public utility facility. It is not open to the public. There are no customers or visitors. The only vehicles that will be accessing the site will be maintenance and repair vehicles from the utility facility owner. There is no parking needed. Thus, this standard does not apply. • Section 4.6-130 through 4.6-135 Loading Areas — The need is not so much for loading areas as it is for staging areas for on-site work activity. In this regard, a gravel surface area is provided from South 66 Place to the reservoir site. These areas meet or exceed the minimum width of 10 feet, minimum length of 25 feet and minimum clear vertical height of 14 feet. In this regard, this standard is met. • Section 4.6-140 through 4.6-155 Bicycle Parking — This facility is not open to the public. Individuals accessing the site will be utility employees in maintenance and repair vehicles. Thus, this standard does not apply. The Satre Group • 375 West 4� Avenue, Suite 201, Eugene, OR 97401 • (541) 6864540 • wv+w.salmamup.wm Springfield Utility Board - South Hills 31d Level Reservoir Replacement Page 13 of 13 Site Plan Review Map 18-02-03-00, Lot 302 D. Parking areas and ingress -egress points have been designed to: facilitate vehicular traffic, bicycle and pedestrian safety to avoid congestion; provide connectivity within the development area and to adjacent residential areas, transit stops, neighborhood activity centers, and commercial, industrial and public areas; minimize driveways on arterial and collector streets as specified in this Code or other applicable regulations and comply with the ODOT access management standards for State highways. Response: The facility does not front on or take access from an COOT facility or a collector or arterial street (South 66th Place and Jessica Drive are local streets). The existing driveway meets intersection standards. Bicycle and transit facilities do not exist in the immediate neighborhood and no demand for such will be generated by this development. E Physical features, including, but not limited to: steep slopes with unstable soil or geologic conditions; areas with susceptibility of flooding; significant clusters of trees and shrubs; watercourses shown on the WQLWMap and their associated riparian areas; other riparian areas and wetlands specified in Section 4.3-117; rock outcroppings; open spaces; and areas of historic and/or archaeological significance, as may be specified in Section 3.3-900 or ORS 97.740-760, 358.905-955 and 390.235-240, shall be protected as specified in this Code or in State or Federal law. Response: Of the physical features listed in this criterion, the following features and how the proposal addresses those is as follows: • Steep Slopes with unstable soil or geologic conditions. There are steep slopes on the site but no unstable soils or geologic conditions. A copy of the geotechnical report is included in the application packet. • Areas with susceptibility of flooding. There are no areas susceptible to flooding. • Significant clusters of trees and shrubs. There are a few trees and shrubs on the property. Trees have been surveyed are shown on the plan set. Trees to be removed are shown on the plan set. A significant portion of the subject property will not be disturbed. Of the disturbed areas interior to the site, native grasses will be planted. • Watercourses shown on the WQLW Map and their associates riparian areas. There are no watercourses on the site. • Other riparian areas and wetlands. There are no riparian areas or wetlands. • Rock outcroppings. There are no areas of rock outcroppings • Open spaces. As it is defined in the Springfield Development code, there are no open spaces on the site. • Areas of historic and/or archeological significance. There are no known historic or archeological areas on the site. IV. Conclusion The above information represents known applicable planning, zoning and site development requirements for the contemplated project. It presents known physical conditions and contexts. It captures the project's primary development objective. Based on the information and findings contained in this written statement, associated exhibits and plan set the proposed SUB 3'1 Level Reservoir project meets the criteria of approval contained in the Springfield Development Code. Therefore, the applicant requests that the City of Springfield approve the proposal. If you have any questions about the above application, please do not hesitate to contact Rick Satre, at The Satre Group, 541-686-4540, or rick(o)satregrouo.com. Sincerely, ZLck &Mre. Rick Satre, AICP, ASLA, CSI, Principal I Partner The Satre Group The Satre Group • 375 West 4'^ Avenue, Suite 201, Eugene., OR 97401 • (541) 686-0540 • w salreirmuo.wm a C J o2s y � m V n g`m of a i No 0 � n(o'3 U i an GF3 O F'9: g9'0 0 :WGS dc5 iW eTh ` W c 2s G 9 w M 'a -P � it " a Oil esu -`� mqW SN¢ E. G 0�� IY Yd � S Pt EEMA i i'ink o _and Y '4 .1.1y y", Ix ,� d' °,� sA. wow 4 14 e. 18q ARM 47 r rR lip, <dy- �� kY .� �� I gyp., 1 r e 1�i 1 y —y,III e v / �� />�-