HomeMy WebLinkAboutPermit Building 1998-06-15SPiINGFIELD
NOTICE:
THIS PERMIT SHALL EXPIRE IF THE V$GHKogNTIAI. PERMIT APPI,IcATIoN
AUTHoBIZED UNDER THIS pEHMtT ts ruorcrrY oF SPRTNGFTELD
coMMENcED oR rs ABANDoNE, ror
*Tl]1,:i:"lili.?-""'o"
ANY 180 DAY PERIOD.
225 North Fifth Street
Spri-ngfie1d, OR 97477
Location of Proposed Work: 2450 20TH ST
.A.ssessors Map #: A7032443
Lot : Bl-ock:
Page 1
Job Number: 980571
Office:
fnspecti-on Line:
726 - 37 59
725 -37 69
Tax Lot #: 01601
Subdivision:
OWNET: JAN CARRIGAIiI
Addressl. 2450 2oTH STREET
Describc WOrK: FA.ITILY ROOM ADDITION
Phone #: 747-605L
city/state/zip: SPRTNGFTELD, oREGON 974-t7
ADDITION
ConEractor
Const.
Contractor #Expires
o6/L3/e8
Phone
687 -6597
QUAD AREA: 5RNW
ZONING CODE: LDR
VN
HEAT SOURCE: WH
-- OFFICE USE
LAND USE:
OCCY GROUP
1111
:R3
# OF BLDGS: 1
CONSTR. TYPE:
SQ FOOTAGE: 288INSUL PATH: P1
To request an inspecEion, cafl the 24 hour recording aL 726-3759
A11 inspections requested before 7:00 a.m. will be made the same working day,
irtspections requested after 7:00 a.m. will be made the following work day.
--- REQUIRED INSPECTIONS ---
TNDERFLOOR PLITMBING - Prior to insufation or decking.
SLAB - To be made after all inslab building service eQuipment, conduiL
piping, and other equipment items are in place but prior to concrete
ROUGH PLITMBING - Prior to cover.
ROUGH ELECTRICAL - Prior to cover.
FRAI{ING - Prior to cover.
SHEAR WALI NAILTNG - Before covering sheathing with finish material-s.
IN$ULATION - FLoor; prior to decking wall/Ceiling; Pri-or to cover
DRYWALL - Prior to taping.
FINAL PLIIMBING - When all plumbing work is complete '
FINAL ELECTRICAL - When alf efectrical work is complete.
FINAL BUILDING - When all required inspections have been approved and
the building is complete.
Lot Faces
Lot Tlpe:
House
E
INTERIOR
N
Setbackssw
51
Total Height: 15 Solar Approved: Y
E
Itsem
Main
Garage
ADDITION
Total Value
Building Permit Fee
Surcharge/aamin
--- BUII,DING PERMTT ---
Square Feet x $/Square Feet Value
0.00
0.00
L8 ,622 .00
L8 ,622 . OO
734
10
50
17
TOTAL FEE
288 64 .56
(A)L4s .27
General:PETERSEN DESIGN 0074534
449 W M STREET SPRINGFIELD OR 97471
SPNINGFIELD
h,
ilob Number : 9 8057 L
of,EaoM
Page 2
PLIruBING PERMIT
Item
Fixtures
Plumbing Permit
Surcharge/Admin
TOTAL CIIARGE (c)
Fee
10.00
15.00
1_ .20
L6.20
MISCELLAI.IEOUS PERMITS
Surcharge/Admin
CITY SDC.
TOTAL MISCELLAI.IEOUS PERMITS (E)
0.00
B3.53
83 .53
(Excluding Electrical)
unless otherwise noted
TOTAL AI,IOITNT DUE - - -
(A, B, C, D, and E combined)245.00
BUILDING VALUE, PLAI.I CHECK AND BUILDING PERMIT
This permit j-s granted on the express condition that. the saj-d construct.ion
shaIl, in all- respects, conform to the ordinance adopted by the City ofSpringfield, includi-ng the Development Code, regulati-ng t.he const.ruction and.
use of buildings, and may be suspended or revoked at any ti-me upon viol-ationof any provisions of said ordj-nances.
Plan Check Fee: 87 .43 Date
Received By:
Pl-ans Reviewed By: AL WARD
Building Site Reviewed By: LISA HOPPER
Paid: os/a4/98
Date: O6/:-5/98
Receipt Number z 29823
--- ADDTTIONAL COMMENTS
A SEPERATE ELECTRICAL PERMIT IS REQUIRED.
By signature, r st.ate and agree, that r have carefurly examined.the completed application and do hereby certify that all- informat.ion hereonis true and correct, and f further certify that any and all work performedshall be done in accordance with the Ordinances of the City of Springfield,
and the Laws of the State of Oregon pertainj-ng to the work described herein,
and that NO OCCUPANCY will be made of any structure without permission of the
Community Services Division, Building Safety. I further certify that onlycontracLors and employees who are in compliance wi-th ORS 701.055 will_ beused on this project.
f further agree to ensure that all required inspections are requested at theproper time, that each address is readable from the street, that the permitcard is located at the front of the property, and the approved set of planswill remain on the site at arl- t.imes during construction.
t \s q
Signat Date
$
I
gPNIr|GFIELTI
.Tob Number: 9BO57l
OTTOF onEcotv
Page 3
--- VALIDATION ---
Receipt Number
Date Paid
Amount Received
Received By:
A 3s3 zf
6
L +
//r
JoB No.7frorlt
ATTACHMENT A
CITY OF SPR]NGFIELD SYSTEMS DEVELOPMENT CHARGE
WORKSHEET
NAME OR COMPANY I,.,.t C,o fTtZt Gq *)
LOCATION 246 o Ztra Sz
DEVELOPMENT TYPE
BUILDING SIZE
ADD t7.ta ^)1c)1nz,
CT SIZ
1 ST0RI'4 DRAIl'lAGl 16 <Zz + 3{'z-
IMPERVIOUS SO FT. 3 52-x $0.225 PER SQ. FT. $ a7,5{
2. SANITARY SE'iER-CITY prr-,v^r& 5eyr,c--
NO. OF PFU'S X $.16. 86 PER PFU
(See Reverse Side)
3. TRANSPORTATiCN
NO OF UNITS X TRIP RATE X COST PER TRIP
x s472 49 $a*X
x _ x $472.49
x x $472.49
0. Ft
$
c
$
$
4. SANiTARY SE.'ER-MhJMC
NO. OF FEU'S X _PER FEU + $10 MI^JMC/ADM FEE q .a-
MI^IMC CREDIT IF APPLICABLE (SET REVERSE)
5, ADMiNISTRATIVE FEES
BASE CHARGE (SUBTOIAL ABOVE) X .05
TOTAL-|',ll/.lMc SDC
SUBTOTAL (ADD ITEMS 1,2,3 & 4)s 71,*
SDC Coordi nator
,utr, g- l8 :77
TOTAL SDC $ 83 ,53
s+*
$ z,qt
RESIDENTIAL
PERMIT APPLICATION
lnspections: 726.3169
Office: 726.3759
SPR LD
JOB NUMBEFI ?to 57 t
225 Fifth Street
Springfleld, Oregon 97477
LOCATION OF PROPOSED WOBK:2,1 Au 2o I
ASSESSORS MAP:/ z,:\zqqz
TAX LOT o/,
SUBDIVISION:
Lor BLocK:
Jn rv
PHONE:
/c STATE:ztP
?
?rqz 7
7 ril^os-/
CITY:
ADDRESS:
OWNER:
NEW
-
REMODEL ADD|TION DEMOLTSH oTHER
DESCRIBE WORK:
ADDRESS
l^./
CONTRACTOR'S NAME
ELECTRICAL:
MECHANICAL:
coNsT.
CONTRACTOR #
GENERAL:
PLUMBING
- OFFICE USE -
QUAD AREA: ffiregon rhfi{&Uf,Eirveu+e-
, oF BLDGS: follow rules adopted bptbFQl6qn Utility
Notilication Center. Those rules are set forth-t{CIfl0E:occY GRoUP: irr O iFl 952=oo1=oo1o thftCIOlftnHlBeel-----ft1$pEf MIT, oF sroRtEs: 0090. You mav obtain cgfiqg gLl$ECUle! iy
WATER H EATE R: ffi snffaiffiIil
sttAt9tRPHEtffi
U r\EEPll{)8 PE Hlfi F[:t S+J€,r
rQ$$rfiffi@ffigF0R_
FLOOD PLAIN
ZONING CODE:
To req uest an ns pect yo u m ust 726-3769.S s 24 h o urlonTht s.ns pec ons requ es ed be fo re 7:OO a m.wl il be
he fol ow ng wo day.rk
Plumbing - When allblng worl( ls complete.
Flnal Electrlcal - When allelectrlcal work is complete.
Final Mechanical - When allmechanical work ls complete.
FInal Building - Vrihen ailrequired lnspectlons have beenapproved and building is
completed.
Other
MOBILE HOME TNSPE TIONS
Blocking and Set.Up - When allblocklng ls complete.
Plumbing Connections - When
home lras been connected to
water and sewer.
Eleclrical Connection - Whenblocklng, set-up, and ptumbing
inspections have been approved
and the home is connected to
the servlce panel.
Final - After all required
lnspectlons are approved andporches, skirting, decks, and
ventlng have been installed.
n
m ade he same work ing d ay,ns pect on req
n Temporary Etectric
Slte lnspectlon - To be made
after excavatlon, but prior tosettlng forms.
Underslab Plumblngl Electrical /
Mechanlcal - Prlor to cover.
Footlng - After trenches are
excavated.
Masonry - Steel locatlon, bond
beams, groutlng.
Foundatlon - After forms are
erected but prlor to concrete
placemont.
Underground Plumblng - Prior
to fllllng trench.
Floor lnsulatlon - Prlor to
decking.
Sanitary Sewer - Prior to filllng
trench.
Storrn Sewer - Prior to fllling
trench.
uested after 7:00 a.m. will be macle
REQUIRED TNSPECTIONS
Rough Mechanlcal - prior to
cover.
Rough Electrical - prior to
cover.
Electrical Servlce - Must be
approved to obtaln permanent
electrlcal power.
Waler Llne - Prlor to filling l-l Fence - When ccrirpleted.
h.
Plumbing - Prlor to
Curbcut & Approach - After
forms are erected but prior to
placement of concrete.
Sidewall< & Driveway - After
excavation ls complete, forms
and sub-base material ln place.
Street Trees - When all requlred
trees are planted.r.
FIn
EXPIFIES .) PHONE
call a
E
E
D
[-l Flreptace - prtor to factngu materlals and framlng lnsp.
l-l Framlng - Prtor to cover.
[-l walt/Ceillng tnsulatlon - prtor tol-r cover.
l-l Drywall - Prtor to taptng.
l-_l Wood Stovo - After lnstaltatton.
n lnsert - After flreplace approval'J and lnstallatlon of unlt.
E
E
tl
tl
[-l Underltoor P]umblng / Mechanlcal
Prior to lnsulatlon or clecking.
[--l Post and Beam - Prlor to floor
-
lnsulatlon or decklng.
tl
E
tl
Lot faces
Lot sq. ftg.
Lot coverage
TopographY
Total height
P.L.HSE GAR ACC
N
S
E
IS THE PROPOSED WORK TN THE -
HISTORICAL DISTRICT, OR ON
THE HISTORICAL REGISTER?
-
lf yes, this applicatlon must be slgned
arrd approved bY the Historlcal
Coordinator prior to permit issuance.
APPROVED:
Set
AND BUILDING PERMIT
This pernrit is granted on the express condition that the said
construction shall, in all respects, conform to the Ordinance
adopted by the City ot Springfield, includlng the
Development Code, regulating the construction and use of
buildings, and may be suspended or revoked at any time
upon violation of any provisions ol said ordinances'
Plans Reviewed BY Date
Receipt Numbe
BUILDING VALUE,LAN CHECK
Date Paid
Received By
VALUE
(A)
BUILDTNG PERMIT
Total Value
Building Permit Fee
State Surcharge
Total Fee
''+
X $/SQ. FT.SO. FT.ITEM
Main
Garage
Carport
Systems Development Charge is due on all undeveloped
properties within tlre City limits which are being improved.
SYSTEMS DEVELOPMENT CHARGE (SDC)
(B)
ADDTTIONAL COMMENTS
Note:
-- Building Inspector may require
- additional plans, information,
-
and/or fees for the cornplction of
this project.
ITEM
Fixtures
Residential Bath(s)
Sanitary Sewer
Water
Storm Sewer
Moblle Home
FEE
N.
7D
l,b!
z/,ia o
2-o
FT.
FT.
(c)
PLUMBING PERMIT
By slgnature, I state and agree, that I have carefully examlned
the completed application and do hereby certlfy that all
information hereon is true anct correct, and I f urther certlfy
that any and all work performed shall be done in accordance
wlth the Ordinanccs of the City of Sprlngfield, and the Laws
of the State of Oregon pertainlng to the work descrlbed
herein, and that NO OCCUPANCY will be made of any
structure without perrnission of the Building Safety Divislon.
I further certify that only contractors and employees who
are in compliance with ORS 701.055 will be used on this
proiect.
I further agree to ensure that all required inspections are
requested at the proper time, that each address ls readable
from tlre street, that the permlt card ls located at the fronl
of the property, and the approved set of plans will remaln
Slgnatu re
Date
on the site at times during constructlon
Wood Stove/ lnsert/Flreplace Unit
Dryer Vent
MISCELLANEOUS PERMITS
Mobile Home
State lssuance
State Surcharge
Sidewalk
-
ft
Curbcut
--_
ft
Demolitlon
State Surcharge
LuL 5nr
UaLo(E)
/4{.\z)
NoVent Fan
(D)
Total Miscellaneous Ferrnits
MECHANICAL PERMIT
Furnace
Exhaust Hood
Mechanical Permit
lssuance
State Surcharge
Total Permit
TOIAL AMOUNT DUE (excluding electrical)
(A, B, C, D, and E Comblned)
I
q
0,(,
BECEIVED AY
VALIDATION:
AMOUNT RECEIVED
RECEIPT NUMBER
DATE PAIi)
7o??t
r ' i,
Lot Type
-
lnterior
-
Corner
.- Panhandlel
-
Cul-de-sac
Plan Check Fee: ---
z
Plumbing Permit
State Surcharge
Total Charge
- FT.
CITY OF OFEGO'U
SPFlINGFIELO
D EV ELOP M ENT S ERVIC ES DE PARTM ENT
May 3,1999
Jan Carrigan
2460 20'h Street
Springfield, Oregon 97 477
Dear Ms. Carrigan:
Your request for an extension of 1,our permits for a family room addition to be located at2460 20'h Street.
Springfield, Oregon, City Job Number 980571 has been reviewed and approved'
This extension may only be granted one time and will expire I 80 days from the date of the granting of the
extension (November 3, 1999).
If you have any questions, or if I may be of any assistance, please feel free to phone rfle at 726-3790 .
Sincerely,
a
Lisa Hopper
Building Safety Supervisor
cc: Dave Puent, Communif-v Sen,ices Manager
lh
225 FIFTH STREET
SPRINGFIELD, OR 97477
(541 ) 726-s753
FAX (s41) 726-3689
-ADDRESS-2460 2OTH ST
DESCR:FAMILY ROOM ADDITION
URBAN GROWTH BOUNDARY
-OWNER_JAN CARRIGAN 747-605L
2460 2OTH STREET
SPRINGFIELD, OREGON 97477
-INFO-
ADDITION
RESIDENTIAL
1111
BUILDING DIVISTON JOB# 98 71
-LEGAL-LOT BLOCK
-VALUE-
1,8622
ACTTVE
L8,62
L70324430L601 980515 / 990323
-ENERGY- _STATS-
HEATI-WH 2_ 1. BLDG ZONE LDRH2O- 1 STORIES FLOODPLAINRANGE- BEDRM OCC GRP R3INSULATION UNITSPATH-PI SQ FEET 288
CONST TYPE VN
-CONTRACTORS_
GENL-PETERSEN DESTGN
CONTRACTOR PHONE-3 44-663 8
PLMB-BL DUMAS
ELECT_C & S ELECTRIC
MECH_
DESGN-
QUAD AREA sRNW
SEQ-REQUIRED PERMTTS- -----_-FEE-_SURCHARGE--DATE-_RECPT--CAT-------VALUE
OO].-061-RES PLAN CHECK
OO2-OO2-BUILDING PERMIT
OO3-OO5-PLUMBING
oo4-070-sDC/sroRM
005-073-SDC/ADMTN
OO6-OO4-ELECTRICAL
O O7 -O O 5-PLUMBING
0 0 8- 0 7 1- -sDC/SANr rARY
009-073-SDC/ADMTN
)-OO6-MECHANICAL
O1- 1--O 87-MECHANICAL I SSUAN
87
L34
15
79
3
56
20
L4T
7
t-5
1_0
.43
.50
.00
.55
.98
.00
.00
.42
.08
.00
.00
.73
.75
.00
.00
98051
98061
98061
98061
98051-
98072
98080
98080
98080
98090
98090
9823
0325
0325
0325
0325
o822
0991
0991
0991
L298
L298
601
510
500
5t- 0
.000
6
0
0
0
2
1
0
0
0
0
0
2
0
0
0
0
0
0
0
0
0
4253535353035343433333
.80
.00
.00
.00
.75
.00
SEQ-MINIMUM INSPECTIONS + REQUIREMENTS-- --EXP DATE---ACT DATE-
520
a 98061 I
980804
9B0B0s
980624
980 81_ 0
980804
981_026
-----DATE---RSLT--INSP
OO1-02 1-UNDERFLOOR PLUMB
002-004-SLAB
OO3-02 3-ROUGH PLUMBING
004-044-ELECTRTC SERVTCE I/200 AMPS
OO5-OO6-FRAMTNG
OO6-1o4-SHEAR WALL NAILIN
O O 7-O O 9-INSULATION
OOB-O].1-DRYWALL
OO9-02g-FINAL PLUMBING
O1O-04g-FINAL ELECTRICAL
011-O]-g-FINAL BUILDING
01.2_042-ROUGH ELECTRIC 3 CIRCUITS
O1-3-04g-FINAL ELECTRICAL
014-023-ROUGH PLUMBING
O]-5-02 g-FINAL PLUMBING
O]- 6-0 3 I-ROUGH MECHANICAL
O1-7_O 3 g-FINAL MECHANICAL
$$
hsEQ--TNSPECTIONS -COMMENTS-------
00r.-009-INSULATToN
002-004-SLAB, 3-OO3-FOUNDATION
v-t4-lO4-SHEAR WALL NAILIN
O05-042-ROUGH ELECTRIC TRAINING WITH DAVE G.
OO6-042-ROUGH ELECTRIC
OO7-044-ELECTRIC SERVICE SUB-CALLED
OO8-042-ROUGH ELECTRIC
980 6r_6
980 618
980622
980624
980720
9807 20
980 804
980804
WIR 38oK 38oK 38oK 38ro 59WIR 6]-OK 6LOK 6L
(
\
W
OI. -JO6-FRAMING
O 1 O-O O 9-INSULATION
01L-0Ll--DRYWALL
O 1 2-O O 9-INSULATION
O1 3-O 2 3-ROUGH PLUMBING
N14-O].6-PROGRESSIVE
. :EPT BATH
t.rCEPT BATHRM
NEED TO FINISH GARAGE WALL
WILL CALL FOR INSP.
980 80s
980 8r-0
980 90 3
981 014
9810 2 6
990323
OK
OK
POK
POK
OK
IO
38
38
38
59
27
38
1-
C;+a
(0
:r
oP
/3
& o+h Sb.
R-
q1
---_
\r^t1 ^3 o \ C t-rrra" r
e
9;"-\ If\\r\l )
q"
Tn^ C 1"n^.r \/-\
C
C'\ \.,e o
5? ., ^JC. - \tr,
oBsGsfdCITY OF
i)roval.
LEGAL
JOB
Address
Phone'141 -^t !cit
Supervi so r icense Number sbs
Expiration Date
Constr Contr. Number e,+q
Expir:ation Date
S ure of SuPervising Electrician
0vners Name
Address {o0
cir
OVNER ALI.A
The installation i
prop erty I ovn whi
for sale, lease or
0vners Signature:
DATE:
S TGFIELO
PERHIT APPLICATION
ty Job Nrlltrb erq 8 051 t
FEE SCEEDUI^E BELOV
dential-Single or
mily per dvelling unit'MuIti-Fa
Permits are,non-transferable and expire
ii vortt is not started vithin 180 days
;i i;;;";"" ot if vork is susPended for
180 days.
2. CONTS.ACTOR INSTALLATION ONLY
Electri cal con trac.or c4 s F[ud.u.n,,Jrw, .
Service Ineluded:
I tems
1000 sq.ft. or less
Each additional 500
sq. ft or Portion
thereof
Each Manuf'd Home or
ModuLar Dvelling
Service or Feeder
Services or Feeders
InstalIation, Alterations
or Relocation:
200 amps or Iess I
201" amps to 400 amPs
-
40L amPs to 600 amPS
-
60L amps to 1000 amPs-
Over 1000 amPs/vo1ts
-
Reconnect 0n1Y
One Circuit
SUBTOTAL OF ABOVB
52 State Surcharge
32 Administrative Fee
TOTAL
Cos t
$ Bs.oo
$ 1s.oo
$ 40.00
Sum
B
c
_5[qos s0.00
s 60.00
s100.00
$130.00
$300.00
$ 40.00
TemporarY Services or Feeders
in"i"fiuilon, Alteration or Relocation
200 amPs''or less
201 amPs to 400 amPs
-
Over 40L to 600 amPS
-
Over 600 amPS or 1000 volts
D. Branch Circuits
Nev, Alteration or Extension P
$
$
$
s
40.
55.
00
00
00
abovexBlr
BO
ee
$
$
er
er Panel
35.00
.
2.00 b.oo
not included)
$ 40.00
s 40.00
$ 20.00
$ 36.00
5
RECEIVED
-40-7<
5 b. c)o
l(-1 -l-q I
n
.1
q-t -q8
J0URI" 0R JOB N0 (tosTt
ATTACHMENT A
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE
WORKSHEET
NAME OR COMPANY Can*rrt 6,WJ,r,,
(/
LOCATION 7f I o Zd
DEVELOPMENT TYPE
BUILDING SIZE
1. STORM DRAINAGE
IMPERVIOUS SQ. FT
2. SANITARY SEWER-CITY
NO. OF PFU'S
(See Reverse Side)
3. TRANSPORTATION
4. SANITARY SEWER-M|^IMC
A. REIMBURSEMENT COST:
5. ADMINISTRATIVE FEES:
BASE CHARGE (SUBTOTAL ABOVE) X .05
SDC Coordi nator
ATTACH'A. I/'JPD
OT SI
X $0.227 PER SQ FT. $
7 x $47.14 PER PFU $ltl1, "f z
Ft
NO OF UNiTS X TRiP RATE X COST PER TRIP
x 5475.32
x $475.32
X
X
$
$
$XNO. OF FEU'S PER FEU
B. IMPROVEMENT COST
NO. OF FEU'S X PER FEU
MWMC CREDIT IF APPLICABLE (SEE REVERSI)
Mt,\lMC ADMINISTRATIVE FEE
SUBTOTAL (ADD ITEMS i,2,3 & 4)$
$
<$
TOTAL.Mt^lt'4c SDC $
$ 10.00
$?,0 g
Date
TOTAL SDC $ I Ll f,fo
FIXTURE UNIT CALCU[ ^-lON TABLE: Number of New Fix .; X Unit Equivatent = Fixture L1aits
(NOTE: For remodels, calculate onl; .re NET additional fixtures)
NUMBER OF UNIT FIXTURE
FIXTURE TYPE NEW FIXTURES EOUIVALENT UNITS
Bathtub.....
Drinking Fountain....
Floor Drain.
lnterceptors For Grease/Oil/Solids/Etc..
lnterceptors For Sand/Auto Wash/Etc..
Laundry Tub/Clotheswasher......
Clotheswasher - 3 Or More.....
Mobile Home Park Trap (1 Per Trailer)..
Receptor For Refrigerator/Water Station/Etc.....
Receptor For Commercial Sink/Dishwasher/Etc.
Shower, Single Sta11..........-z-
Shower, Gan9.........
Sink: Bar, Commercial, Residential Kitchen
Urinal, Stall/Wall
Wash Basin lLavatory , Single.....
Toilet, Public lnstallation.
Toilet , Private......
Miscellaneous:
TOTAL FIXTURE UNITS
CREDIT CALCULATION TABLE: Based on assessed value. lf improvements occurred after annexation date in table,
calculate credits se arates
/Head
2
1
2
3
6
2
6
6
1
3
2
1
2
2
1
6
4
I
-L
Credit for Parcel or Land Only lf Applicable
lmprovement (if after annexation date)
x$
(Rate X Assessed Value)
(Rate X Assessed Value)
CREDIT TOTAL $
Year
Annexed
Rate per $1,OOO
Assessed Value
Year
Annexecl
Rate per $1,OOO
Assessed Value
1979 or before
1 980
1 981
1982
1 983
1 984
1 985
1 986
1 987
1 988
$4.27
4.18
4.12
3.99
3.83
3.68
3.48
3.1 8
2.82
2.42
1 989
1 990
1 991
1992
1 993
1 994
1 995
1 996
1 997
$1.98
1.55
1.15
0.96
o.83
0.67
o.52
0.38
o.21
RUNOFF COEFFICIENTS FOR STORM DRAINAGE
(For Estimating Purposes Only)
Residential....,
Commerical...
lndustrial.......
Governmental
o.4
0.9
o5
o.5
FIXUNIT.WPD IMPERVIOUS AREA = TOTAL LOT SIZE X RUNOFF COEFFICIENT
' ln I,nL rt"'Yl I u,{|.tvrJLr{ I l\.'lu t ADLtr,: Number of New Fixtgles X Unit Equivalent = Fixrure Units(NorE: For remodels, carculate o.. ^ h" NET additional fixtures)
FIXTURE TYPE
Bathtub......
Drinking Fountain..
Floor Drain.,
lnterceptors For GreaselOil/SoiidsiErc.................
lnterceprors For Sand/Auto Wash1Etc..................
Laundry Tub/Clotheswasher....
Clotheswasher - 3 Or More....
Mobile Home Park Trap (1 per Trailer)..................
Receptor For Refrigerator/Water Station/Etc........
Receptor For Commercial Sink,,DishwasheriEtc..
Shower, Single Stall...
Shower, Gang....
Sink: Bar. Commercial, Residerrtiai Kitchen............
Urinal, Stall/Wall...
Wash Basin lLavatory, Singie..
Toiiet, Pubiic lnsrallation.
Toiler, Private.......
Miscellaneous:
NUMBER OF
NEW FIXTURES
TOTAL FIXTURE UNITS
UNIT
EOUIVALENT
FIXTURE
UNITS
adeiH
2
i
2
,)
o
Z
A
6
,l
J
2
I
2
2
1
6
4
CREDIT CALCULATION TABLE: Based on assessed value. lf im provements occurred after annexation date in rable.calculate ci'edits rates
Credit for Parcel or Land Onty lf Applicable
lmprovement (if after annexation date)
x s_
(Rate X Assessed Value)x $_
(Rate X Assessed Value)
CREDIT TOTAL s
Year
Annexed
Rate per $1,000
Assessed Value
Year
Annexed
Rate per $1,COO
Assessed Value
1979 or before
1 980
1 981
1 982
1 983
1 984
1 985
1 986
1987
1 988
1 989
1 990
1 991
1 992
1 993
1 994
1 995
1 996
vz.co
2"17
1.73
1.31
o.92
o.74
0.61
0.45
0.31
o.17
RUNOFF COEFFICIENTS FOR STORM DRAINAGE
(For Estimating Purposes Only)
Fesioen iiai..
Commerical
tndustrial. . . .
Governmental..
0.4
0.9
o5
0.s
lMPERVlous AREA : TorAL Lor stzE x RUNOFF coEFFtctENT
$3.97
3.89
3.83
3.70
3.55
3.39
3.20
2.91