Loading...
HomeMy WebLinkAboutPlan, Tentative APPLICANT 10/13/2021SITE PHOTO SITE NAME: CRAN_RWOR_E0002_004H PREPARED FOR =-; AT&T POLE#: A0356801 SCIP ID#: 16450-004H 19801 TUALAW7 897062ND . TUALATIN, OR 97062 SITE TYPE: WOOD UTILITY POLE Vendor: SITE ADDRESS: 160 S 14TH STREET fJ5INFRASTRUCTURE IL AT&T 2030 MAIN ST. SPRINGFIELD OR 97477 IRVINESUTE 200 IC 614 � J5 PROJECT ID: P-042818 - COUNTY: LANE COUNTY Vendor: JURISDICTION: CITY OF SPRINGFIELD SITE INFORMATION VICINITY MAP LOCAL MAP PROJECT DESCRIPTION Vendor: SITE INFORMATION: SITE NAME: CRAN_RWOR_EUG02_004H - rr'iy" `; PROPOSED SITE BUILD OF AN UNMANNED TELECOMMUNICATIONS FACILITY, ON AN PROPOSED UTILITY POLE WITHIN THE PUBLIC RIGHT -OF SKIP ID # : 16450-004H LATITUDE: 44°2'41.7834"N (44.04494) LONGITUDE: -123°0'20.4114"W (-123.00567) CsIwholesalev T .....: ii 716a - as -` 7-7 $J WAY CONSISTING OF THE FOLLOWING: SITE ADDRESS: 160 S 14TH STREET I - ^p r` f REMOVAL: •• (1) EXISTING WOOD UTILITY POLE SPRINGFIELD, OR 97477DRAWN BY: MLDV COUNTY: LANE COUNTY North }r - B ti :77 INSTALLATION: JURISDICTION: CITY OF SPRINGFIELD ZONING CLASSIFICATION: C - COMMERCIAL springRaid alley Rlver Center •• (1) PROPOSED AT&T CANISTER ANTENNA (1) PROPOSED AT&T ANTENNA MOUNT CHECKED BY: JDM CONSTRUCTION TYPE: N/AQ OCCUPANCY: N/A Skinner Butte Park ae (1) PROPOSED AT&T DISCONNECT/SURGE SUPPRESSOR ADJACENT PARCEL#: 1703363204201OVERLAY (3) PROPOSED AT&T CONDUITS AT&T STAND-OFF MOUNTS ZONE: NONEPROPOSED Eugene r r �, •• (1) PROPOSED AT&T EQUIPMENT ENCLOSURE SPECIAL AREA SUBZONE: NONE „a .x. (� •• (1) PROPOSED WOOD UTILITY POLE A.D.A COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION _ ♦ ,n Springfield �' IF _. � .T llnlverslty f � � - � � i�T at Oregon = TE POLE OWNER: CENTURY LINK , ADDRESS: 111 A STREET CHENEY, WA 99004 age HIII L - c 4 PHONE: (509) 235-3349 APPLICANT/CARRIER: NEW CINGULAR WIRELESS PCS, LLC ("AT&T") 'f %"'' ADDRESS: 19801 SW 72ND AVE. TUALATIN, OR 97062 Mt Pisgah POLE POLE CHANGE CONTACT: KRISTY WEAVER Arboretum PHONE: (425) 214-2186 Goshen Jasper =1 '" r a lit REQUIRED 0 06/09/21 10046 CDs REV DATE I DESCRIPTION Licensor: u � PJB OO p4a � 89198PE PROJECT TEAM CODE COMPLIANCE DRIVING DIRECTIONS SHEET INDEX REV. ENGINEER: SRE ACQUISITION: ALL WORK AND MATERIALS SHALL BE PREFORMED AND INSTALLED IN ACCORDANCE WITH CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCATION GOVERNING AUTHORITIES. DIRECTIONS FROM PDXAIRPORT: T-1 TITLE SHEET 0 GN -1 GENERAL NOTES 0St q�ONEGON,p O 9 9y 13,7 Jam' INHG�6 g/Z1 J5 INFRASTRUCTURE PARTNERS J5 INFRASTRUCTURE PARTNERS CONTACT: JAMES CHUNG CONTACT: NATALIE ERLUND 1. HEAD NORTHWEST ON NE AIRPORT WAY (10 FT) A-1 OVERALL SITE PLAN 0 1 EXPIRES: 12131/21 EMAIL: jchungQJ5IP.com EMAIL: nerlundQJ5IP.com COMMERCIAL BUILDING CODE: 2. TURN LEFT (0.2 MILES) A-1.1 DEMO SITE PLAN 0 PHONE: (949) 247-7767 x 111 PH: (503) 539-9247 OREGON STRUCTURAL SPECIALTY CODE (OSSC)-2019 3. TURN LEFT (0.2 MILES) A-2 ENLARGED SITE PLAN 0 . AT&T CONSTRUCTION MANAGER: CONSTRUCTION MANAGER: COMMERCIAL ELECTRICAL CODE: 4. SLIGHT LEFT ONTO NE AIRPORT WAY (1.8 MILES) A-3 IA LETTER AND SURVEY - A-4 ELEVATIONS 0 i HRRRev cRRnry THAT THESE Burs WERE PREPARED BY ME OR UNDER MV DIRECT SURERVISION ANDTHATI AM Dury RRciSrRRRD eNcmeER uNDRR THE uws orrHR STATE OrOREcoN OREGON ELECTRICAL SPECIALTY CODE (OESC)-2021 5. SLIGHT RIGHT TO MERGE ONTO I-205 S TOWARD I-84 (0.5 MILES) A-5 ELEVATIONS 0 CONTACT: CHARLIE PITT J5 INFRASTRUCTURE PARTNERS 6. MERGE ONTO I-205 S (2.6 MILES) AT&T Site ID: EMAIL: cp]261@att.com CONTACT: DEVIN TAYLOR PH: 971-295-6924 7. TAKE EXIT 21 B TO MERGE ONTO I-84 W/US-30 W TOWARD PORTLAND (5 MILES) D-1 DETAILS 0 PH: (503) 309-1380 TO OBTAIN LOCATION OF PARTICIPANTS 8. KEEP LEFT TO CONTINUE ON I-84 W (0.4 MILES) D-2 DETAILS 0 UNDERGROUND FACILITIES BEFORE YOU DIG IN OREGON, CALL OREGON 811 9. TAKE THE EXIT ONTO I-5 S (1.5 MILES) D-3 DETAILS 0 D-4 DETAILS 0 CRAN_RWOR_EUG02_004H AT&T RF ENGINEER: A&E MANAGER: UTILITY NOTIFICATION CENTER OO 10. KEEP RIGHT TO STAY ON I-5 S, FOLLOW SIGNS FOR INTERSTATE 5 S/SALEM (9.6MILES) RF -1 RF WARNING SIGNS 0 CONTACT:LEI WANG JS INFRASTRUCTURE PARTNERS TOLL FREE: 1-800-332-2344 OR ��� 11. KEEP LEFT TO STAY ON I-5 S (96.8 MILES) UC -1 UTILITY COORDINATION SITE PLAN 0 16450-004H EMAIL: IW4124Qatt.COm CONTACT: JOSH MALBERG www.digsafelyoregon.com 12. TAKE EXIT 194A TO MERGE ONTO OR -126 E (0.4 MILES) E-1 PLUMBING DIAGRAM & DC POWER SCHEMATIC 0 EMAIL: jmalbergQj5ip.com PH: (208) 316-1897 OREGON STATUTE Know what's below. REQUIRES MIN OF 2 13. KEEP RIGHT TO STAY ON OR -126 E (0.8 MILES) G-1 GROUNDING DETAILS 0 1 60 S 14TH STREET WORKING DAYS NOTICE 14. TAKE THE EXIT TOWARD SPRINGFIELD CITY CENTER (0.4 MILES) G-2 TYPICAL GROUNDING DIAGRAM 0 SPRINGFIELD, OR 97477 ATT PROJECT MANAGER: PROJECT MANAGER: C81I before ou dl . BEFORE YOU EXCAVATE y 15. TURN RIGHT ONTO PIONEER PKWY W (1 MILE) 16. CONTINUE ONTO S 2ND ST (SIGNS FOR OREGON 126 BUSINESS E) (180 FT) CONTACT: WENDY LONG JS INFRASTRUCTURE PARTNERS EMAIL:wlongQj5ip.com CONTACT: MARTHA MILLER 17. TURN LEFT ONTO S A ST (0.9 MILES) Sheet Title: LEGAL DESCRIPTION 18. TURN LEFT ONTO 14TH ST (233 FT) TITLE SHEET PH: (206) 321-1116 EMAIL: mmillerQj5ip.com PH: (510) 325-3362 RIGHT-OF-WAY Sheet Number: DO NOT SCALE DRAWINGS T-1 CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME SITE WORK GENERAL NOTES 1. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 2. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES, SUBCONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION. 3. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS. 4. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 5. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED. PLUGGED, OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, OWNER, AND/OR LOCAL UTILITIES. 6. THE SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE. 7. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENT AND TOWER AREAS. 8. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW, OR ICE SHALL BE PLACED IN ANY FILL OR EMBANKMENT. 9. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 10. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT, OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE PROJECT SPECIFICATIONS. 11. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 12. NOTICE TO PROCEED - NO WORK TO COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF A PURCHASE ORDER. 13. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN AND SHALL MEET ANSI/TIA 1019 (LATEST EDITION), OSHA AND GENERAL INDUSTRY STANDARDS. ALL RIGGING PLANS SHALL ADHERE TO ANSI/TIA-1019 (LATEST EDITION) INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION. GENERAL NOTES 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR - J5 INFRASTRUCTURE PARTNERS SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) CARRIER - AT&T OEM - ORIGINAL EQUIPMENT MANUFACTURER 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE THEMSELVES, WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORM CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR AND AT&T 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 4. DRAWINGS PROVIDED HERE ARE NOT TO SCALE AND ARE INTENDED TO SHOW OUTLINE ONLY. 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 6. "KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED BY CONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE SUPPLIED BY THE SUBCONTRACTOR. 7. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONTRACTOR AND AT&T PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 9. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWINGS. 10. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT THE SUBCONTRACTOR'S EXPENSE; TO THE SATISFACTION OF THE OWNER. 11. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 12. SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION; TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. ABREVIATIONS AND SYMBOLS: ABREVIATION AGL ABOVE GRADE LEVEL BTS BASE TRANSCEIVER STATION (E) EXISTING MIN MINIMUM REF REFERENCE RF RADIO FREQUENCY T.B.D. TO BE DETERMINED T.B.R. TO BE RESOLVED TYP TYPICAL REQ'D REQUIRED EGR EQUIPMENT GROUND RING AWG AMERICAN WIRE GAUGE MOB MASTER GROUND BAR EG EQUIPMENT GROUND BCW BARE COPPER WIRE SIAD SMART INTEGRATED ACCESS DEVICE IRG INTERIOR GROUND RING (HALO) RBS RADIO BASE STATION SYMBOLS: S/G SOLID GROUND BUS BAR 5 N SOLID NEUTRAL BUS BAR g°- SUPPLEMENTAL GROUND CONDUCTOR o�a 2 -POLE THERMAL -MAGNETIC CIRCUIT BREAKER A� SINGLE POLE THERMAL -MAGNETIC GRADE TO ABOVE GRADE MUST BE #2 TINNED CIRCUIT BREAKER 8 CHEMICAL GROUND ROD BELOW GRADE TO WITHIN 3" TO 6" OF TEST WELL Q' DISCONNECT SWITCH END OF THE LIQUID TIGHT CONDUIT MUST BE METER (ADD EXOTHERMIC WELD (CADWELD) GROUND STANDARD DETAIL AS WELL). (UNLESS OTHERWISE NOTED) VDC NEG_ MECHANICAL CONNECTION GROUNDING WIRE ELECTRICAL INSTALLATION NOTES 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES 2. CONDUIT ROUTINGS ARE SCHEMATIC SUBCONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC, HILTI EPDXY ANCHORS ARE REQUIRED BY AT&T. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 5. CABLES SHALL NOT BE ROUTED THROUGH LADDER -STYLE CABLE TRAY RUNGS. 6. EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, Y" PLASTIC ELECTRICAL TAPE W/ UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM W/ NEC AND OSHA. 7. ALL ELECTRICAL COMPONENTS SHALL BE LABELED W/ THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (I.E. PANEL BOARD AND CIRCUIT ID'S). 8. PANEL BOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 9. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 10. POWER, CONTROL AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG OR LARGER), 60OV, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90-C (WET & DRY) OPERATION LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE SPECIFIED. 11. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (#6 AWG OR LARGER), 600V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION CLASS B OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR, TYPE TO CABLE (#14 AWG OR LARGER), 50OV, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90'C (WET AND DRY) OPERATION WITH OUTER JACKET LISTED OR LABELED FOR THE LOCATION USED UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATE FOR OPERATION AT NO LESS THAN 75'C (90'C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E. RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (RIGID PVC, SCHEDULE 40 ) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90'S AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTING ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 21. WIREWAYS SHALL BE EPDXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS, SHALL BE CONDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) 22. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED, CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES.CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 23. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET STEEL; SHALL MEET OR EXCEED UL 50 AND RATED NEMA 1 (OR BETTER) INDOORS OR NEMA 3R (OR BETTER) OUTDOORS. 24. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY- COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) INDOORS OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 25. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) INDOORS OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 26. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 27. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 28. INSTALL PLASTIC LABEL ON THE METER CENTER TO SHOW "####". 29. ALL CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. GROUNDING NOTES 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTING PROTECTION AND AC POWER GESS) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS 3. THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTING OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 AWG COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 AWG SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK, CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 AWG SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTORS OR COPPER CLAD STEEL CONDUCTORS SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6FT OF MAIN GROUND WIRES WITH 1-#2 AWG TIN-PLATED COPPER GROUND CONDUCTOR. 19, GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS, WHEN IT IS REQUIRED TO BE HOUSED IN A CONDUIT, SAID CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (I.E. NON-METALLIC MATERIAL PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT LEG 1 FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE LIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). DESCRIPTION PHASE./CODE LETTER WIRE COLOR 240/120 10 LEG 1 HIACK LEG 2 RED WHITE AC NEUTRAL N GROUND (ECC) G GREEN VDC POS + 'RED -POLARITY MARK AT TERMINATION VDC NEG_ *BLACK -POLARITY MARK AT TERMINATION 240V OR 20BV, 30 PHASE A BLACK PHASE B RED (ORG. IF HI LEG) PHASE C BLUE 48OV, 30 PHASE A BROWN PHASE B ORANGE PHASE C YELLOW * SEE NEC 210.5(C)(1) AND (2) PREPARED FOR AT&Ti 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: G1 SINFRASTRUCTURE /P A R T N E R 3 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: 0 06/09/21 100% CDs REV DATE DESCRIPTION 21 EXPIRES: 12131/21 .I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OFTHE STATE OF OREGON AT&T Site ID: CRAN-RWOR-EUG02-004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: GENERAL NOTES Sheet Number: GN -1 INFORMATION SHOWN BELOW FOR DEPICTION PURPOSES ONLY. ALL DATA GATHERED FROM PUBLIC RECORDS AND GENERATED FROM AERIAL IMAGES AND SITE VISITS. INFORMATION DOES NOT CONSTITUTE A LEGAL BOUNDARY SURVEY AND SHOULD NOT BE USED FOR SURVEYING OR OTHER RELATED PURPOSES. STRUCTURAL ANALYSIS IS UNDER A SEPARATE PERMIT BY OTHERS. f(E) BUILDING) i (E) �PARKING� LOT PARCEL# : 1703363204201 OVERALL SITE PLAN w CAUTION: (E) OVERHEAD UTILITY LINES I I I I I I I I - — (1) (F) AT&T POWER LINE (UNLESS OTHERWISE INDICATED ELECTRICAL WORK TO BE PERMITTED AND PERFORMED BY OTHERS) (UNDER SEPARATE PERMIT) (E) WOOD UTILITY POLE (A0356801) I (P) AT&T DISCONNECT / SURGE SUPPRESSOR (P) AT&T EQUIPMENT ENCLOSURE �i I (P) AT&T CANISTER ANTENNA ON NEW MOUNT I I / I ii - 2. II L -�(F.O.C. TO PO !° I I A-5 30'-0" (TO C.L.) 60'-0" (Tq R.O.W.) I W W I ry I c~ I Z I N REFER TO ENLARGED SITE PLAN ON SHEET A-2 I I I I � I oaf "Z- . Xc0 (E) TREES (TYP) � o Fe - v I "�—(E) BUILDING 24"x36" SCALE: 1" = 10'-0" 10 5 0 10' PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: �51NFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: Licensor: 1 I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ,ULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN-RWOR-EUG02-004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: OVERALL SITE PLAN Sheet Number: A-1 1 INFORMATION SHOWN BELOW FOR DEPICTION PURPOSES ONLY. ALL DATA GATHERED FROM PUBLIC RECORDS AND GENERATED FROM AERIAL IMAGES AND SITE VISITS. INFORMATION DOES NOT CONSTITUTE A LEGAL BOUNDARY SURVEY AND SHOULD NOT BE USED FOR SURVEYING OR OTHER RELATED PURPOSES. TE: TO DE REMOVED AND DISPOSED OF IN A ED L LEGAL MANNER. f(E) BUILDING DEMO SITE PLAN I %L ' I I I I I I I I I I f(E) BUILDING (E) PARKING I LOT CAUTION: (E) OVERHEAD UTILITY LINES I I (E) WOOD UTILITY POLE (A0356801) (TO BE REPLACED) PARCEL# : 1703363204201 w V L IJ L IJ V) 2 M R.O.W.) 24"x36" SCALE: 1" = 10'-0" 10 5 0 10' PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: '5 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: k,SVINI g/21 EXPIRES: 12/31/21 .I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON' r AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: DEMO SITE PLAN Sheet Number: A-1.1 1 I I I w I I I I _Z I I I I d I a I I I I I I I I / I I I I I I I I I I I %L ' I I I I I I I I I I f(E) BUILDING (E) PARKING I LOT CAUTION: (E) OVERHEAD UTILITY LINES I I (E) WOOD UTILITY POLE (A0356801) (TO BE REPLACED) PARCEL# : 1703363204201 w V L IJ L IJ V) 2 M R.O.W.) 24"x36" SCALE: 1" = 10'-0" 10 5 0 10' PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: '5 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: k,SVINI g/21 EXPIRES: 12/31/21 .I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON' r AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: DEMO SITE PLAN Sheet Number: A-1.1 1 NOTES: 1. NEW EQUIPMENT SHALL BE PAINTED FAIRFAX BROWN TO MATCH WOOD POLE. 2. EQUIPMENT IS MOUNTED WITHIN ENCLOSURE ON THE UTILITY POLE 3. AC PANEL/DISCONNECT MOUNTED ON ENCLOSURE 4. CLEAR CLIMBING QUADRANT 5. NEW ANTENNA & MOUNT ON UTILITY POLE 6. CONTRACTOR TO INSTALL THE ENCLOSURE ON THE STREET SIDE 7. LIGHT POLE/POWER POLES ARE INTENDED TO BE PLACED IN THE ROW ONLY. 8. CONTRACTOR SHALL VERIFY ROW BOUNDARY PRIOR TO PLACIl' NEW POLE. 9. ALL LANDSCAPING AND SPRINKLERS SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. 10. ANY DISTURBED CONCRETE/BRICKWORK IN EXISTING SIDEWALK BE REPAIRED TO MATCH CURRENT CONDITIONS AND CODE. INFORMATION SHOWN BELOW FOR DEPICTION PURPOSES ONLY. A DATA GATHERED FROM PUBLIC RECORDS AND GENERATED FROM AERIAL IMAGES AND SITE VISITS. BOUNDARIES DEPICTED HEREIN M NOT ALIGN WITH ACTUAL LEGAL BOUNDARIES AND SHOULD NOT E USED FOR SURVEYING OR OTHER RELATED PURPOSES. LIGHT POLE/POWER POLES ARE INTEDED TO BE PLACED IN THE ROb ONLY. CONTRACTOR SHALL VERIFY ROW BOUNDARY PRIOR TO PLACING A NEW POLE PARCEL# : 1703363204201 ENLARGED SITE PLAN i ZA 0 CAUTION: (E) OVERHEAD UTILITY LINES (1) (F) AT&T POWER LINE (UNLESS OTHERWISE INDICATED ELECTRICAL WORK TO BE PERMITTED AND PERFORMED BY OTHERS) (UNDER SEPARATE PERMIT) (3) (P) AT&T CONDUITS ON (P) 12"STAND-OFF: (1) 2"CONDUIT W/ WEATHERHEAD FOR POWER TO AC DISCONNECT ATTACHED NEXT TO EQUIPMENT ENCLOSURE ON POLE: (1) 2" CONDUIT FOR FIBER: (1)4"CONDUIT FOR (12) LINES OF 1/4"COAX FROM EQUIPMENT ENCLOSURE TO ANTENNA (E) WOOD UTILITY POLE (A0356801) (P) AT&T DISCONNECT/ SURGE SUPPRESSOR (P) AT&T EQUIPMENT ENCLOSURE (P) AT&T CANISTER ANTENNAON NEW MOUNT (P) AT&T WORK AREA 2'-0" (F.O.C. TO POLE) - (E) CURB — — — — I 22'-1" (C.L. OF THE STREET TO POLE) 30'-0" (TO C.L. OF THE STREET) 7 1- W W F— e 24"x36" SCALE: 3/8" = 1'-0" PREPARED FOR AT&T .F 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: '5 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: 21 EXPIRES: 12131/21 .I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON' AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: ENLARGED SITE PLAN Sheet Number: A-2 2' 1®' ORT PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 1A SURVEY CERTIFICATION SCIP ID#: 16450—C-'4 I NAD 83 z " Kelly .q g° �sr Butte m l� 35 36 LAT – 44°02 41.77 N �endor: q w z z It I ( 44.04494) �5 INFRASTRUCTURE vE ? 4 a` '. 3 h ~e.sr t I I LONG – 123°00'20.41" W P A R T N E R S 2030 MAIN ST. g > a FST N 34 h� (-123.00567) SUITE 200 IRVINE, CA 92614 — � '" IN Sir W 1) ST I ELEV = 467.00' NAVD 88 J5 PROJECT ID: P-°'28'8 Vendor: BIB ti G Sr' e I �O528 =J� ~� a H 8 Sr )kerAST p HT. =24.8' I d HT.=22.5' Bike DIA.=0.86 ridge I MAIN.ST.. - a HT.=ZZ.O' 126 I _ - ►3"34 4 3 SprirwielI }DOE Spingfeld CENTER OF SUBJECT POLE –SEE DETAIL Vendor: Judkinsenwrad 34 r r IOOFCem a i Roint ' I lytM �i z >/� - O rr N JLaurel _ o ' a c� HT. HT 14 �r SITE E.. I NGc { E1i�u.7Yf T �Fj- ~� `_ '`Z J HT 8 6 DRAWN BY: MLDV ;, 1�t. n N 4f - ) C (D a wV J N] w S CHECKED BY: JDM 2 225 GEOGRAPHIC COORDINATES ° 30'TOCL 6o'To ROW LATITUDE: 44°02'41.77" N (44.04494) (NAD 83) x CONCRETE A.= if LONGITUDE: 123'00'20,41" W (-123.05567) (NAD 83) a " GROUND ELEVATION: 467.00 FEET (NAVD 88) <4 I ELV.=467.00' ` HEIGHT: @ TOP OF POLE: 24.84 FEET (ACL) ❑ d I 4 0 0 06/09/21 100% CDs DATE OF SURVEY: MAY 24, 2021a. REV DATE DESCRIPTION 2000 0 1000 2000 4000 a I POLE DETAIL RE: SCIP ID#: 16450-004 I Licensor, 160 14TH STREET s SPRINGFIELD, OR 97477 1 INCH = 2000 FEET +I d – NOT TO SCALE – 89198PE I CERTIFY THAT THE LATITUDE AND THE LONGITUDE SHOWN ABOVE AREj v OREGON �p 9sy13,�G��� 1 ACCURATE TO WITHIN +15 FEET HORIZONTALLY AND THAT THE SITE REGISTERED VIN" 6 9 ELEVATION IS ACCURATE TO WITHIN +3 FEET VERTICALLY, WHICH MEETS I PROFESSIONAL EXPIRES: 12131/21 1A STANDARDS AS DEFINED ON THE FAA ASAC INFORMATION SHEET I LAND SURVEYOR 91:003. THE HORIZONTAL DATUM (GEOGRAPHIC COORDINATES) ARE IN spn �W oh P LEGEND "IHEREBY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM TERMS OF THE NORTH AMERICAN DATUM OF 1983 (NAD 83) AND ARE REGISTERED DIpEhn E bhn Him bus, 999 o -58F and Seni�. email=andmx.plel[�sflands.mm ISTERE ENGITTHESEDERTEWERE LAWSPREPARED AT DULY REGISTERED ENGINEER RUNDERTHE WWSOETHESTATE of OREGON EXPRESSED A5 DEGREES ( }, MINUTES ( ), AND SECONDS ( ). TO PROFESSIONAL � POWER POLE D4 WATER VALVE LominmVanmoeerWA „o; THE NEAREST HUNDREDTH OF A SECOND. THE VERTICAL DATUM LAND SURVEYOR DREGO � GUY ANCHOR DECEMBER 30, 2010 AT&T Site ID: (ELEVATION AMSL) IS IN TERMS OF THE NORTH AMERICAN VERTICAL)i,i Ny111,AndreWJahn IiItt ANDREW JOHN PLETr EN=cU-A,dmWJo Plea, c=U, o=9&FLan35emices. DATUM OF 1988 (NAVD 88). ROW LINES SHOWN ARE APPROXIMATE, BASED DN GIS DATA, AND NOT A BOUNDARY SURVEY 785.`iF CRAN-RWOR-EUG02_004H ,,, email=ar re%.pfe @® Fds.co WA Date: GREG q Date: 05/26/2021 RENEWS 12/31/22 SHEET _05/26/2021 16450-004H ■ ServicEs Proj NO: 2020-177-62 DECEMBER 30, 2010 S&F LandSepvicr=sProf NO: 2020-177-62 1 OF 1 Prepared: SHEET ANDREW JOHN PLETT L.K.U. Prepared: LK.U_ 4858 SW SCROLLS FERRY RD, SUITE A www.sflcndscom 78538PLS PORTLAND, OR 97225 1 OF 1 4658 SW SCHOLLS FERRY RD, SUITE A www.sfiandE.com _ PORTLAND, OR 97225 �5 160 S 14TH STREET infaOsflvndscam Checked: A-J•P• 503-345-0328 RENEWS 12/31 /22 infv®sflvnds.cvm 1"=10' 503-345-0328 Scale: SPRINGFIELD, OR 97477 Sheet Title: 1A LETTER AND SURVEY Sheet Number: A-3 I A LETTER 2 SURVEY- 1 NOTE: 1. NEW EQUIPMENT TO BE PAINTED FAIRFAX BROWN WITH RFTRANSPARENT, UV RESISTANT, OUTDOOR RATED PAINTED TO MATCH REPLACEMENT LIGHT POLE. 2. ALL CRAN EQUIPMENT, CONDUITS AND STAND-OFF TO BE PAINTED FAIRFAX BROWN. 3. CONTRACTOR SHALL RE -INSTALL ALL EXISTING STREET SIGNS AS NEEDED ON NEW POLE. 4. CONTRACTOR TO INSTALL ENCLOSURE ON STREET SIDE. 5. MAINTAIN A b" CLEARANCE FROM ENCLOSURE TO POLE. b. INSTALL RF WARNING SIGNS PER MANUFACTURER SPECIFICATIONS AS REQUIRED BY LAW OR BY THE POLE OWNER. NO ADDITIONAL SIGNAGE WILL BE POSTED. 7. PRESERVE THE CLIMBING SPACE ON THE FIELD SIDE OF THE POLE DISCLAIMER: ALL INFORMATION PERTAINING TO EXISTING POLE AND ANTENNA MOUNTS ARE FOR DEPICTION PURPOSES ONLY. CONFIRMATION OF THE STRUCTURE AND ASSOCIATED STRUCTURAL ELEMENTS ARE BEYOND THE SCOPE OF THIS PROJECT. IN NO EVENT WILL J5 INFRASTRUCTURE PARTNERS BE LIABLE AND RESPONSIBLE FOR THE STRUCTURES STRUCTURAL INTEGRITY AND ADEQUACY WITHOUT A STRUCTURAL ANALYSIS DETERMINED AS SUCH PRIOR TO NEW INSTALLATIONS. PREPARED FOR ' AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 8. PROPOSED CONDUITS TO BE LOCATED ON 18" STAND-OFF WITH MAX. b" CLEARANCE FROM THE POLE. Vendor: 9. FIBER TO BE PROVIDED BY OTHERS UNDER SEPARATE PERMIT. 10 ALL.NDSCAPING AND SPRINKLERS SHALL BE RESTORED TO ORIGINAL CONDITION OR BET )SINFRASTRUCTURE 11. ANY DISTURBED CONCRETE/BRICKWORK IN EXISTING SIDEWALK TO BE REPAIRED TO P A R T IN E R s MATCH CURRENT CONDITIONS AND CODE. 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 STRUCTURAL ANALYSIS OF EXISTING/NEW POLES ARE BY OTHERS. J5PRoJECrID: P-042918 el Vendor: AT&T IS RESPONSIBLE FOR MAKE READY COORDINATION AND CONSTRUCTION. (P) AT&T RF WARNING NOTICE SIGNS SEE DETAILe RF -1 Vendor: T.O. PROPOSED AT&T CANISTER ANTENNA/T.O. PROPOSED WOODEN POLE (1) (P) AT&T CANISTER ANTENNA SEE DETAIL ELO 36'-0" (A.G.L.) e2 D-1 RAD CENTER OF PROPOSED AT&T CANISTER ANTENNA ELEV. 35-0" (A.G.L.) B.O. OF PROPOSED AT&T CANISTER ANTENNA _ EY LEV. 34'-0" (A.G.L.) (1) (P) AT&T PRE MANUFACTURED STAND-OFF ANTENNA MOUNT SEE DETAIL 2 3 B.O. PROPOSED AT&T STAND-OFF MOUNT/T.O. PROPOSED CONDUIT ELEV. 33'-0" (A.G.L.)� DRAWN BY: MLDV VIII CHECKED BY: JDM Iilll�l (1) (F) AT&T POWER LINE OTHERWISE INDICATED ELECTRICAL WORK N(UNLESS (1 TO BE PERMITTED AND PERFORMED BY OTHERS) CAUTION: (E) OVERHEAD UTILITY LINES (UNDER SEPARATE PERMIT) 0 T.O. EXISTING WOODEN POLE p, ELEV. 24'-10" (A.G.L.) 'y I 7z0 (1) (F) AT&T FIBER LINE III A.L.(F)POWERLINE III+ (UNLESS OTHERWISEINDICATEDELECTRICALWORK ELEV. 23'-6" (A.G.L.) off I off TO BE PERMITTED AND PERFORMED BY OTHERS) EXISTING OVERHEAD UTILITY LINES p � � EXISTING OVERHEAD UTILITY LINES � (UNDER SEPARATE PERMIT) ELEV. 22'-b" (A.G.L.) °H J� oHW ELEV. 22'-6" (A.G.L.) off Hw � VIII I A.L.(F) FIBER LINE off IIII OHw h1NI I" ELEV. 21'-b" (A. G. L.) B.O. PROPOSED AT&T EQUIPMENT ENCLOSURE / PROPOSED AT&T DISCONNECT ELEV. 19'-8" (A. G. L.) I (P) AT&T EQUIPMENT ENCLOSURE SEE DETAIL D-4 D-4 D-4 0 06/09/21 100% CDs REV DATE DESCRIPTION II Licensor: VIII � T.O. PROPOSED AT&T EQUIPMENT ENCLOSURE (2) (P) AT&T RF WARNING NOTICE SIGNS (BEHIND) SEE DETAIL RF -1 S 89198PE ELEV. 16'-0" (A. G. L.) 1111 I pIr I IIII (1) (P) AT&T IDENTIFICATION SIGN (BEHIND) SEE DETAIL RF 1 OREGON v9.L 9T' 13 1%,'0 r`&VINHG6 91 ISI I I EXPIRES: 12131/21 I I (P) AT&T DISCONNECT /SURGE SUPPRESSOR SEE DETAIL VIIII VIII D-1 iii Er.Eev CERTIFY THAT THESE Furs WERE PREPARED BY ;tE OR UNDER My DIRECT SUFERVISION ANDTHAT i Ann L _ w REGISTERED ENGINEER UNDER THE LAWS OFTHE STATE OF OREGON' I'I I (E) WOOD UTILITY POLE (A0356801) III I AT&T Site ID: (TO BE REPLACED) II �I I I (P) WOOD UTILITY POLE (A0356801) CRAN_RWOR_EUG02_004H IIgIIII I I II I J 16450-004H III I (E) SIDEWALK/GRADE (E) SIDEWALK/GRADE 160 S 14TH STREET IIII IIII �I SPRINGFIELD, OR 97477 I'Ne III Sheet Title: FINISHED GRADE III FINISHED GRADE ELEVATIONS ELEV. O,_0„ ELEV. 0.0" Sheet Number: A-4 EXISTING EAST ELEVATION 24"x36" SALE: 3/8" = 1'-0"Z® 2 PROPOSED EAST ELEVATION 24"x36" SCALE: 3/8" = V-0" L®- 1 NOTE: 1. NEW EQUIPMENT TO BE PAINTED FAIRFAX BROWN WITH RF TRANSPARENT, UV PROPOSED CRAN CONDUIT PLAN DISCLAIMER: ALL INFORMATION PERTAINING TO EXISTING POLE AND ANTENNA PREPARED FOR RESISTANT, OUTDOOR RATED PAINTED TO MATCH REPLACEMENT LIGHT POLE. 2. ALL CRAN EQUIPMENT, CONDUITS AND STAND-OFF TO BE PAINTED FAIRFAX BROWN. 3. CONTRACTOR SHALL RE -INSTALL ALL EXISTING STREET SIGNS AS NEEDED ON NEW POLE. 4. CONTRACTOR TO INSTALL ENCLOSURE ON STREET SIDE. 5. MAINTAIN A b" CLEARANCE FROM ENCLOSURE TO POLE. b. INSTALL RF WARNING SIGNS PER MANUFACTURER SPECIFICATIONS AS REQUIRED BY LAW OR BY THE POLE OWNER. NO ADDITIONAL SIGNAGE WILL BE POSTED. 7. PRESERVE THE CLIMBING SPACE ON THE FIELD SIDE OF THE POLE 8. PROPOSED CONDUITS TO BE LOCATED ON 18" STAND-OFF WITH MAX. b" CLEARANCE MOUNTS ARE FOR DEPICTION PURPOSES ONLY. CONFIRMATION OF — — — —� THE STRUCTURE AND ASSOCIATED STRUCTURAL ELEMENTS ARE BEYOND THE SCOPE OF THIS PROJECT. IN NO EVENT WILL J5 (P) 4" COAX CONDUIT INFRASTRUCTURE PARTNERS BE LIABLE AND RESPONSIBLE FOR THE I STRUCTURES STRUCTURAL INTEGRITY AND ADEQUACY WITHOUT A (P) 12" STAND-OFF AT4'-0"O.C. STRUCTURAL ANALYSIS DETERMINED AS SUCH PRIOR TO NEW I INSTALLATIONS. (P) 2" FIBER CONDUIT I & o (P) 2" POWER CONDUIT s ^"� AT&T 1 F 19801 SW 72ND AVE. TUALATIN, OR 97062 FROM THE POLE. 9. FIBER TO BE PROVIDED BY OTHERS UNDER SEPARATE PERMIT. 10. ALL LANDSCAPING AND SPRINKLERS SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. 11. ANY DISTURBED CONCRETE/BRICKWORK IN EXISTING SIDEWALK TO BE REPAIRED TO MATCH CURRENT CONDITIONS AND CODE. j (P) WOOD UTILITY POLE A0356801 Y I I i- Vendor: '5 INFRASTRUCTURE P A R T R E R S 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 STRUCTURAL ANALYSIS OF EXISTING/NEW POLES ARE BY OTHERS. I J5 PRO JeCT ID: P21is Vendor: AT&T IS RESPONSIBLE FOR MAKE READY COORDINATION AND CONSTRUCTION. 24"x36" SCALE: 3/8" 1'0 ® _`_' — " 3 ' 1' 0" 2' o- 2I� (P) AT&T RF WARNING NOTICE SIGNS 11 SEE DETAIL( Vendor: RF -1 T.O. PROPOSED AT&T CANISTER ANTEN NA/T.O. PROPOSED WOODEN POLE (1)(P)AT&T CANISTER ANTENNA ELEV. 36'-0" (A.G.L.) SEE DETAIL �2 RAD CENTER OF PROPOSED AT&T CANISTER ANTENNA I D-1 ELEV. 35-0" (A.G.L.) (1) (P) AT&T PRE MAN UFACTU RED STAND-OFF B.O. OF PROPOSED AT&T CANISTER ANTENNA _ ELEV.34'-0"(A.G.L.) ANTENNAMO NT B.O. PROPOSED AT&T STAND-OFF MOUNT/T.O. PROPOSED CONDUIT SEE DETAIL 2 3 ELEV. 33'-0" (A.G.L.) D-2 D-2 u(I DRAWN BY: MLDV 1111 I CHECKED BY: JDM CAUTION: (E) OVERHEAD UTILITY LINES (1) (F) AT&T POWER LINE 1111 (UNLESS OTHERWISE INDICATED ELECTRICAL WORK TO BE PERMITTED AND PERFORMED BY OTHERS) T.O. EXISTING WOODEN POLE (UNDER SEPARATE PERMIT) ELEV. 24'-10" (A. G.L.) I b" I'll A.L. (F) POWER LINE (\J EXISTING OVERHEAD UTILITY LINES l� 0 ELEV. 23'-6" (A. G.L.) I (1) (F) AT&T FIBER LINE EXISTING OVERHEAD UTILITY LINES (UNLESS OTHERWISE INDICATED ELECTRICAL WORK I ELEV. 22'-6" (A.G.L.)� oHw TO ELEV. 22'-6" (A.G.L.) 11 - TO BE PERMITTED AND PERFORMED BY OTHERS) (UNDER SEPARATE PERMIT) T.O. WIRE/GUYED WIRE CONNECTION Ill A.L. (F) FIBER LINE ll ELEV. 22'-0" (A.G.L.) I b ELEV. 21'-b" (A. G.L.) B.O. PROPOSED AT&T EQUIPMENT ENCLOSURE / PROPOSED AT&T DISCONNECT 0 06/09/21 10096 CDs 1� l ELEV. 19'-8" (A.G.L.) I : REV DATE DESCRIPTION Ill I' l l Licensor: I\J I� I Ill l �1I I 1 11 T.O. PROPOSED AT&T EQUIPMENT ENCLOSURE (P) AT&T EQUIPMENT ENCLOSURE L Illi SEE DETAIL 1 2 3 ELEV. 16'-0" (A.G.L.) 11 (2) (P) AT&T RF WARNING NOTICE SIGNS (BEHIND) I SEE DETAIL 1 RF 89198PE OREGON v-7 �9Y 13,1%�J�0 &VINIAG 6 9 1 Ill' I�1 -1 Ill Il1I EXPIRES: 12/31/21 1111 (1) (P) AT&T IDENTIFICATION SIGN (BEHIND) 1111 l SEE DETAIL1 J l I R F-1 (P) AT&T DISCONNECT / SURGE SUPPRESSOR " HEREev CERTIFY THAT THESE Puna WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ENGINEER UNDER THE FAWS OFTHE STATE OF OREGON' SEE DETAIL (E) WOOD UTILITY POLE 3 ,l T.O. EXISTING WIRE SUPPORT Illy (A0356801) D-1 AT&T Site ID: ELEV. 8'-7" (A. G.L.) I'll (TO BE REPLACED) 111 111 (P) WOOD UTILITY POLE (Ao356801) I CRAN RWOR_EUG02_004H _ 16450-004H 1111 I (E) SIDEWALK/GRADE 1111 (E) SIDEWALK/GRADE 160 S 14TH STREET Ij SPRINGFIELD, OR 97477 �I 1111 1111 Sheet Title: FINISHED GRADE FINISHED GRADE ELEVATIONS ELEV. 0'-0" ELEV. o'_O. Sheet Number: A-5 EXISTING SOUTH ELEVATION 24"x36" SALE: 3/8" = 1'-0"2 2' 1' 0 2 1 PROPOSED SOUTH ELEVATION 24"x36" SCALE: 3/8" = V-0' 2' 1' 0 2 PSEUDO OMNI 12-PORT CANISTER ANTENNA PREPARED FOR MANUFACTURER: GALTRONICS PART NUMBER: GQ2412-136613 DIAMETER: 14.5" HEIGHT: 24.0" WEIGHT W/MOUNT: 22.7 LBS AT&T VOLUME: 2.29347 CUBIC FEET PAINT: FAIRFAX BROWN 19801 SW 72ND AVE. TUALATIN, OR 97062 14.5" Vendor: 'S INFRASTRUCTURE ® 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: N 0 0o also s 1695-9}60 Wh l Vendor: SISP-5825 MHe 9651 690-996 WE- 452 0 1_' ,H 495-0Gf DRAWN BY: MLDV ® ® CHECKED BY: JDM v N FRONT VIEW BOTTOM VIEW NOT USED ANTENNA SPECIFICATIONS 4 2 N.T.S. N.T.S. SURGE PROTECTION BOX MANUFACTURER: RAYCAP PART NUMBER: RSCAC1333-P-240-DL WEIGHT: 8 LBS DIMENSIONS (LxWxH): 9.38" x 6.25" x 10.43" VOLUME: (0.781 FT) x (0.52FT) x (0.869 FT) = 0.353 CUBIC FEET PAINT: FAIRFAX BROWN 0 06/09/21 100% CDs REV DATE DESCRIPTION 6.25' 9.38" 5.06' Licensor: 8.59" J. 89198PE OREGON )'t3,2% ,�p O 9 9' �FSVINHG 91 6 EXPIRES: 12/31/21 o 06 _ = o `h v c M p • I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED 9v ME OR UNDER MY DIRECT SUPERVISION AND THAT IAM DULY REGISTERED ENGINEER UNDER THE LAWS OFTHE STATE 0 OF OREGON' AT&T Site ID: O CRAN RWOR EUG02 004H 16450-004H SIDE VIEW FRONT VIEW M40 GLANDS CAN BE 160 S 14TH STREET REPLACED BY 1-1/4" NPT SPRINGFIELD, OR 97477 CONDUIT FITTINGS Sheet Title: o ❑ o o DETAILS wri 0, 0 OSheet Number: D-1 3 AC DISCONNECT W/ SURGE PROTECTION SPECIFICATION BOTTOM VIEW 1 NOT USED N.T.S. N.T.S. NOT USED N.T.S. AT-WP-OMNFGALT S'PLEII ANTENNA SIDE MOUNT BRACKET N.T.S. SHIP PPPw W.. U-BJLT INEW, BILL OF MATERIALS PC M0.PK OIY 1 DESCRIPTION IOIALSHIP SO=2414 Suppa'Etl ON 'c W tl�VSz>loINDM ME Pz IM¢c 2 tl1a 1) 1.0'Mw do. AT -WP -OMNI -GALT Il Nlnole WlydS I M_M_Wird Sp®1 WM lz: ED 9] npF m�n��aos: v IopcgroP4c Cdrgxy FI: C G�D,,J Foch. Gn la Wlntl DI—H— PI — Ktl_ 095 BEY ISIHc—: 11 —h NOTES: 1. CONTRACTOR SHALL ADJUST THE MOUNT FOR FIT -UP AS REQUIRED. 2. ALL INSTALLATION INCLUDES RELEVANT ATTACHMENTS TO THE STRUCTURE SHALL BE IN ACCORD WITH THE REQUIREMENTS SET BY THE MANUFACTURER. N.T.S. NUT/LW/CBP/COIL/NUTSQ [2 PLCS] 'OSED CANISTER ANTENNA TEL: GALTRONICS / GQ2412-86613 PROPOSED STAND-OFF WELDMENT MODEL: AT -WP -OMNI -GALT -CB -1 01/2" x 2 1/2" x 4" U -BOLT 2NUT/2LW/2FW [2 PLCS] PREPARED FOR AXT 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: /'J5 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P -042B18 Vendor: 0 06/09/21 100% CDs REV DATE DESCRIPTION Licensor: A. "I HEREBY CERTIFY THAT THESE PIAM WERE PREPARED 9Y ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: DETAILS Sheet Number: D-2 AT -WP -OMNI -GALT OMNI ANTENNA MOUNT AM nc Ta rCmpw ,LLC INSTALL DRAWING IEASSAIRM INDusRwLORJ31 ATC CATALOG SALEM.OR 9 1 arZ7 ITT MI6 4177 IFI'FE ' OA9 IH DOSEUMEN16wEPROPRETARV W. ER 06/01 /Z11a 6 GIB APPROVED OF ADVAILED IOWERCQMPM ONES NO FOUAS NOTED R RCONSIRUSBIONON D6LOPURE REPR)'DUSBION OR USE OF FINISH =A IM GALVANQIb TOLERANCE ANYPARTIHEREOFMAYEEMADEDPCEPI WELdNG: SIEELGR�:FI%EXWW FRACTION. ]� R171201G LCLLG4.44 PEW RITIEN PERASSIdJ_ nm ��e ac m.n vunc ANf.IFN NOTES: 1. CONTRACTOR SHALL ADJUST THE MOUNT FOR FIT -UP AS REQUIRED. 2. ALL INSTALLATION INCLUDES RELEVANT ATTACHMENTS TO THE STRUCTURE SHALL BE IN ACCORD WITH THE REQUIREMENTS SET BY THE MANUFACTURER. N.T.S. NUT/LW/CBP/COIL/NUTSQ [2 PLCS] 'OSED CANISTER ANTENNA TEL: GALTRONICS / GQ2412-86613 PROPOSED STAND-OFF WELDMENT MODEL: AT -WP -OMNI -GALT -CB -1 01/2" x 2 1/2" x 4" U -BOLT 2NUT/2LW/2FW [2 PLCS] PREPARED FOR AXT 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: /'J5 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P -042B18 Vendor: 0 06/09/21 100% CDs REV DATE DESCRIPTION Licensor: A. "I HEREBY CERTIFY THAT THESE PIAM WERE PREPARED 9Y ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: DETAILS Sheet Number: D-2 NOT USED N.T.S. NOTES: 1. CONTRACTOR SHALL ADJUST THE MOUNT FOR FIT -UP AS REQUIRED. 2. ALL INSTALLATION INCLUDES RELEVANT ATTACHMENTS TO THE STRUCTURE SHALL BE IN ACCORD WITH THE REQUIREMENTS SET BY THE MANUFACTURER. 3. ALL CONDUIT AND STAND-OFFS PAINTED FAIRFAX BROWN. 1/4" LAG BOLT, (3) AT EA. STAND-OFF PRE MANUFACTURED ASSEMBLY WOOD UTILITY POLE WOOD UTILITY POLE CONDUIT CONNECTION DETAIL N.T.S. ELEVATION VIEW 12" , I..j PRE MANUFACTURED ASSEMBLY (P) 4" COAX CONDUIT UNISTRUT CONDUIT CLAMP (P) 2" FIBER CONDUIT (P) 2" POWER CONDUIT UNISTRUT CONDUIT CLAMP (P) 4" COAX CONDUIT (P) 2" FIBER CONDUIT UNISTRUT CONDUIT CLAMP (P) 2" POWER CONDUIT PREPARED FOR AMT 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: 51NFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P -042B]8 Vendor: 0 06/09/21 100% CDs REV DATE DESCRIPTION Licensor: A _ 1 "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: DETAILS Sheet Number: D-3 NOTES: 1. CONTRACTOR SHALL ADJUST THE MOUNT FOR FIT -UP AS REQUIRED. 2. ALL INSTALLATION INCLUDES RELEVANT ATTACHMENTS TO THE STRUCTURE SHALL BE IN ACCORD WITH THE REQUIREMENTS SET BY THE MANUFACTURER. MANUFACTURER: COMMSCOPE SSC -760238852 ITEM NO. PART NUMBER DESCRIPTION QTY. 1 MTM101101 ENCLOSURE MOUNT BRACKET WELDMENT 1 2 MT -382-14 5/8" X 14" GALV THREADED ROD 2 3 SW -58 BACKING PLATE.188"X2.5"X2.5" W/ 11/16" HOLE 2 4 GWF-05 5/8" GALV FLAT WASHER 4 5 GWL-05 5/8" GALV LOCK WASHER 4 6 GN -05 5/8" GALV HEX NUT 4 7 100521-109 WSHR,FLAT,M10,1 SS5x20x1.20,SST,PA 2 8 100522-37 WSHR, LK, SPLT, MID, SST, PASS 2 9 100534-13 SCR,HCS,HEX,M10X20,SST,PASS 2 10 SWF-03 3/8" SS FLAT WASHER 1 11 SWL-03 3/8" SS LOCK WASHER 1 12 GB -03125 3/8" X 1-1 /4" GALV BOLT KIT 1 ENCLOSURE POLE MOUNT 6" STANDOFF ASSEMBLY N.T.S. 4X 4X 4X 2X NT BRACKET e D-4 EQUIPMENT ENCLOSURE o MANUFACTURER: COMMSCOPE METROCELL RADIO CONCEALMENT ENCLOSURE PART NUMBER: SSC -760237600 DESCRIPTION: MICRO RADIO SOLUTION STANDARD COLOR: FAIRFAX BROWN WEIGHT FULLY LOADED: 300 LBS VOLUME: (3.667 FT) x (1.75 FT) x (1.667 FT) = 10.7 CUBIC FEET SHOWN MOUNTED ON AN 8" POLE CLAMP. STRAP. AND THRU BOLT OPTIONS 3" KNOCKOUT FOR CABLE ENTRY/EXIT O (CROSS CUT RUBBER BROMMETS INCLUDED) FULLY VENTILATED WITH GR487 COMPLIANT PERF PATTERNS 21" TOP VIEW 20" v v IIY FRONT VIEW SIDE VIEW EQUIPMENT ENCLOSURE SPECIFICATION N.T.S. UNIVERSAL POLE MOUNT BRACKET TAMPER RESISTANT LATCH WITH PADLOCK HASP Z0]Ii0]SNVAMTiT- REAR VIEW (2) 1-1/4" TRADE SIZE KNOCKOUTS TAMPER RESISTANT MI0SCREWS 0 3" KNOCKOUT FOR RF CABLE ROUTING OPTION UNIVERSAL POLE MOUNT BRACKET (2) 1" TRADE SIZE KNOCKOUT (2) 02" KNOCKOUT FOR CABLE ENTRY/EXIT o 3 o 162 IIY FRONT VIEW SIDE VIEW EQUIPMENT ENCLOSURE SPECIFICATION N.T.S. UNIVERSAL POLE MOUNT BRACKET TAMPER RESISTANT LATCH WITH PADLOCK HASP Z0]Ii0]SNVAMTiT- REAR VIEW (2) 1-1/4" TRADE SIZE KNOCKOUTS TAMPER RESISTANT MI0SCREWS 0 3" KNOCKOUT FOR RF CABLE ROUTING OPTION UNIVERSAL POLE MOUNT BRACKET (2) 1" TRADE SIZE KNOCKOUT (2) 02" KNOCKOUT FOR CABLE ENTRY/EXIT EtWLLOFEDRE MOUNT BRACKET N.T.S. PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: 15 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042918 Vendor: Licensor: • MHEREBY CERTIFY THAT THESE PLAINS WERE PREPARED BY E OR UNDER MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: DETAILS Sheet Number: D-4 4 3 162 NOTES11 1. ALL METRIC DIMENSIONS ARE IN BRACKETS 1 ICN: o 1 1e 2. FEATURES CRITICAL TO QUALITY ARE INDICATED IN AN OVAL CZ) 3. WELDING WORKMANSHIP PER AWS 31.1, TABLE 6.1 4. FINISH: PAINTED. -x SUFFIX ON PRODUCT PART NUMBER REPRESENTS SPECIFIC COLOR AND/OR FINISH. REFER TO MEfROCELL PRODUCT D COLOR/FINISH SPECIFICATION MTM1004 FOR SPECIFIC REQUIREMENTS. D 5. CHASE THREAD AFTER GALVANIZED CHASE THREAD AFTER GALVANIZED 125 0 A a 41 z �z6.e[6e1.4 ] 25.8[656.0 ] ' o do B 22.1 [560.7 ] C 4 c S 2.3[313.1 ] SCALE ALE1 1 1 m 0.8[240.6 ] (17.35[440.7 ]) 3 ElB 0[0.0 ] SECTIONAA A scuEr.s o. MAT'L: FPS 441 .188[4. B 4PLACES o B 188 ff ff 5.00[127.0 ] (6.00[152.41 COMMSCOPE, INC. OF NORTH CAROLINA i01ERPNCB SPPWRRLLLkM9t oPUSE x- .25 IPUCExXf ,06 MTM101101-% iPLWE x:.12 ..s }z EN. Na1ENA SEE NOTE A36 45.0° 45.0 DETAILS 010 ?54 .. I — 1. SCALE I:1 [ $e� CE 02/1118 A S Rx ENCLOSURE MOUNT BRACKET WELDMENT CINSNY 6& Lffi' :a REM NO. PART NUMBER DESCRIPTION OTY. Ewss Tflm Pa 3yiibr I TMIONC2 ENCLOSURE POPE BRACKET 1 wwRE ea in 6ya LIQ RE TP �L1118 SX. .... N. 9JRRACENEA iw in ESN 6000026500 1.4 M�M101101SERIES 2 TMI01103 SUPPORT, STANDOFF 2 1111H 3 TM101104 POLE MOUNT 1 im st& woRRRRM NAM oRtn'- S�Ei CQ015Cwnm5wp,Inc CaftlrAl IENT11 M. C V9251]N � � SIRTIS PEN9W VE�WS NS PEN9W fOFf 4 IN 032H BLACK, 1B18 NUT, 2H 1 mum (1 4 3 2 1 EtWLLOFEDRE MOUNT BRACKET N.T.S. PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: 15 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042918 Vendor: Licensor: • MHEREBY CERTIFY THAT THESE PLAINS WERE PREPARED BY E OR UNDER MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: DETAILS Sheet Number: D-4 M RF WARNING SIGNS \VAILABLE FROM EXCEL SIGN AND DECAL: ittps://vvvvw.weneedsigns.com/product.php? prod uct id=171904&cat=1135&page= l -LICK ON AT&T 'H: 510-651-0445 401 -DC -16 1"x6' NOTICE DECAL FOR 1 FOOT DISTANCE" VYVYL DECAL WITH ADHESIVE BACKING ORDER COMES IN A PACK PF 25. PLACE THREE NOTICE STICKER EQUALLY SPACED AROUND THE BOTTOM OF THE ANTENNA RADOME RF WARNING NOTICE SIGN AT ANTENNA f M AT&T TGA R D_002 1=800=638=2822 I SITE NAME SHOWN IS FOR EXAMPLE PURPOSES ONLY. THE APPROPRIATE SITE NAME SHALL BE INDICATE AT EACH SITE SHOWNUSID NUMBER LY. THE APPROPRIATE U S I D: 192355 L L NUMBOER SES SHOAILL BEINDICATE AT EACH SSIITTE IDENTIFICATION SIGN AT DISCONNECT 5" NOTICE ON THIS POLE: RADIO FREQUENCY FIELDS NEAR SOME ANTENNAS MAY EXCEED FCC RULES FOR HUMAN EXPOSURE PERSONNEL CLIMBING THIS TOWER SHOULD BE TRAINED FOR WORKING RADIO FREQUENCY ENVIRONMENTS AND USE A PERSONAL RF MONITORING IF WORKING NEAR ACTIVE ANTENNAS. IN ACCORDANCE WITH FEDERAL COMMUNICATION COMMISSION RULES ON RADIO FREQUENCY EMISSIONS 47 CFR 1.1307(B) 5" (3 DIGITS REE 000 NETWORK OPERATION CONTROL CENTER (NOC) 1-800-264-6620 NODE ID #12 THIS SITE IS COMPLIANT WITH FCC RULES FOR BOTH OCCUPATION AND CONTROLLED AND GENERAL PUBLIC OR UNDERCINTROLLED STAY BACK A MINIMUM OF 4 FEET FROM ANY ACTIVE ANTENNA TO DEACTIVATE ANTENNA CALL THE N.O. PHONE NUMBER BEFORE OPERATING DISCONNECT REENTER I.D. NUMBER SHOWN IS FOR EXAMPLE PURPOSES ONLY. THE APPROPRIATE NODE I.D. SHALL BE INDICATE AT EACH NODE NODE NUMBER SHOWN IS FOR EXAMPLE PURPOSES ONLY. THE APPROPRIATE NODE I.D. SHALL BE INDICATED AT EACH NODE NOTES: 1. WARNING SIGNS TO BE MOUNTED, IN VIEW, ON EQUIPMENT ENCLOSURE ON THE SAME SIDE AS THE DISCONNECT. 2. WARNING SIGNS TO BE INSTALL PER MANUFACTURES SPECIFICATIONS AND FCC. SIGNS ALLOWED ONLY AS REQUIRED BY LAW OR BY THE POLE OWNER. NO ADDITIONAL SIGNAGE WILL BE POSTED. RF WARNING NOTICE SIGNS AT EQUIPMENT ENCLOSURE 24"x36" SCALE: NTS PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: 'S INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: 0 06/09/21 100% CDs REV DATE DESCRIPTION EXPIRES: 12/31/21 21 .I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OFTHE STATE OF OREGON AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: RF WARNING SIGNS Sheet Number: RF -1 1 UNLESS OTHERWISE INDICATED FIBER AND ELECTRICAL WORK TO BE PERMITTED AND 11 PERFORMED BY OTHERS. J I } w, d 0I a I I I I I II I I II (E) f(E) BUILDING) PARKING LOT PARCEL# : 1703363204201 UTILITY COORDINATION SITE PLAN � I I I I I I I I - - I CAUTION: (E) OVERHEAD UTILITY LINES I I I I I I (1) (F) AT&T POWER LINE (UNLESS OTHERWISE INDICATED ELECTRICAL WORK TO BE PERMITTED AND PERFORMED BY OTHERS) (UNDER SEPARATE PERMIT) (E) WOOD UTILITY POLE III I I (A0356801) (P) AT&T DISCONNECT /SURGE SUPPRESSOR (P) AT&T EQUIPMENT ENCLOSURE II (P) AT&T CANISTER ANTENNA ON NEW MOUNT I I cl L7 00 vO a O S �o Q o o (E) TREES �� Cel (TYP) � o � n G r] �i o C' � v f(E) BUILDING 24"x36" SCALE: 1" - 10'-0" 10 5 0 PREPARED FOR J AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: 'S INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: 0 06/09/21 100% CDs REV DATE DESCRIPTION) 21 IXPIRES: 12/31/21 .I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUREWISION AND THAT I AM ,ULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN_RWOR_EUG02_004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: UTILITY COORDINATION SITE PLAN Sheet Number: UC 1 1 0-P011 M &HI!I 53rid AntHnn2 M Barad 1 r� IC2�2 RRH-R Ms 1 F.Dr !p , 6nc3ikr Dark Fi bors tem Hub PLUMBING DIAGRAM �y �Location Ifuw J 47df? in nid-Oafld) Antenna Op(tilarff: - -SI-lgOe Anle ina wab - 4 POM MId- G 8i11d (2 GHZ) + 2 PDMS H IgI�-Bar1d (!5GHZ) - Aha Trate Piraducit sUpportIng Law -P a nd an dinr 3.5 GHz Cqa I��-- AC Source P GS I.ALWG Crass Barrel -Carnbinc r - FRH -1: 4T4F1 Air-Sc;i la Mi -c ro 9251POG - RE H-2: 4T4F Air -Sr a III Yi-c ro BffaMWS - AC Powr Modules CPJRJR {0. SIJUJI. RC0&0& 1-Q6 iFL[- - 6 F ilm rs Fronthaki] regal rrd PANEL SCHEDULE VOLTAGE, PHASE: 120V 2W, 1 PH xxx 22KA MTG. xxx VA: 4020 xUx BOTTOM AMPS XXX NEMA RATING: NEMA 4x MAIN BRKR: 60 AMPS �y �Location Ifuw J 47df? in nid-Oafld) Antenna Op(tilarff: - -SI-lgOe Anle ina wab - 4 POM MId- G 8i11d (2 GHZ) + 2 PDMS H IgI�-Bar1d (!5GHZ) - Aha Trate Piraducit sUpportIng Law -P a nd an dinr 3.5 GHz Cqa I��-- AC Source P GS I.ALWG Crass Barrel -Carnbinc r - FRH -1: 4T4F1 Air-Sc;i la Mi -c ro 9251POG - RE H-2: 4T4F Air -Sr a III Yi-c ro BffaMWS - AC Powr Modules CPJRJR {0. SIJUJI. RC0&0& 1-Q6 iFL[- - 6 F ilm rs Fronthaki] regal rrd PANEL SCHEDULE VOLTAGE, PHASE: 120V 2W, 1 PH AIC 22KA MTG. VA: 4020 FEED: BOTTOM AMPS 33.5 NEMA RATING: NEMA 4x MAIN BRKR: 60 AMPS p CRT DESCRIPTION VA PER PHASE BRKR P cr"i1 NO. L-1 L-2 AMPS 1 RADIO - 1 670 15 1 2 RADIO - 2 670 15 1 3 SPARE 670 15 1 4 SPARE 670 15 1 5 SPARE 670 15 1 6 SPARE 670 15 1 - CONNECTED VA/PHASE 2010 2010 - CONNECTED AMPS/PHASE 16.75 16.75 24"x36" SCALE: NTS 121 DC POWER SCHEMATIC THIS DOES NOT CONSTITUTE AS A ONE LINE DIAGRAM. POWER DESIGN AND ONE LINE DIAGRAM TO BE FINALIZED WITH POWER PROVIDER AND ELECTRICAL ENGINEER. ELECTRICAL DISCONNECT ---------------------------- (N) 3/q' SCH. 80 PVC CONDUIT W/ (1) #6 GROUND WIRE (N) 1%2' SCH. 80 PVC CONDUIT WITH PULL ROPE UP UTILITY POLE!, SEE ELEVATIONS FOR CONDUIT LOCATION 24"x36" SCALE: NTS PREPARED FOR AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: 15 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: EXPIRES: 12/31/21 21 I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF OREGON AT&T Site ID: CRAN-RWOR-EUG02-004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: PLUMBING DIAGRAM & DC POWER SCHEMATIC Sheet Number: E-1 1 NOTES: 1. ALL METALLIC PARTS OF THE INSTALLATION ON THE POLE SHALL BE BONDED TOGETHER AND BARREL COMPRESSION GROUNDED. 7A COPPER GROUND WIRE, #6 AWS MINIMUM SIZE SHALL BE INSTALLED FROM THE BASE OR FEEDLINE ATTACH TO GROUND CONNECTION POINT OF THE ANTENNA TO A GROUND ROD AT THE BASE OF THE POLE AND BE INSTALLED ADJACENT TO THE ANTENNA FEEDLINE CONDUIT. THE GROUND WIRE SHALL BE PERMANTLY CONNECTED CONTRACTOR TO THE GROUND ROD. 3. WHERE A UTILITY CO. NEUTRAL CONDUCTOR EXISTS, THE GROUND WIRE SHALL BE PERMANTLY BONDED BOND OVER CLAMP BEFORE TO THE UTILITY CO. NEUTRAL CONDUCTOR AT THE NEUTRAL CONDUCTOR LEVEL BY UTILITY CO. CREWS. 4 A GROUND ROD, 8 FEET MINIMUM IN LENGTH SHALL BE INSTALLED (WHERE NO UTILITY CO. GROUND GROUND WIRE ON POLE BETWEEN FACE (NOTCH ROD & INTACT GROUND WIRE EXISTS) AT THE BASE OF THE POLE. THIS INSTALLATION SHALL MEET OR 3. EXCEED THE REQUIREMENTS OF CONSTRUCTION GUIDELINE D16-2 5. THE GROUND WIRE SHALL BE COVERED BY A PROTECTIVE MOLDING FOR ITS ENTIRE LENGTH ON THE REFERENCE OF UTILITY CO. STD. POLE, EXCEPT AT THE POINT WHERE IT MUST BE EXPOSED FOR BONDING TO THE UTILITY CO. NEUTRAL. 6. THE UTILITY CO. AND COMMUNICATION GROUND RODS SHALL BE BONDED TOGETHER USING COPPER #6 AWG WIRE G R O U I V M N G NOTES 24"x36" SCALE: NTS COAXIAL GROUND KITS W. LONG BARREL COMPRESSION DOUBLE LUG WITH SIGH HOLE, ATTACH TO GROUND BAR & INSTALLED BY ANTENNA CONTRACTOR 0 0 0,0000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O '000000000000000000' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #2 SOLID BARE TINNED COPPER GROUND BAR COPPER WIRE (TYP.) INSTALLED BY GENERAL CONTRACTOR NOTES: 1. COAT ALL MECHANICAL CONNECTION WITH "NOOX" OR APPROVED EQUAL 2. ALL GROUND LUGES TO HAVE INSPECTION WINDOWS/SIGHT HOLES to] 10l0l♦11111I IImiy2,01 NOT USED 24"x36" SCALE: NTS GROUND BAR IN #6 AWG TO ANTENNA GROUNDS AND EQUIPMENT GROUNDS TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 AWG BCW TO GROUND ROD J 24"x36" SCALE: NTS NOTES: 1. GROUND WIRE MOLDING SHALL BE INSTALLED OVER THE BARE GROUND WIRE TO PROTECT LINE WORKERS, THE WIRE, AND THE PUBLIC. EXTEND PLASTIC MOLDING AT LEAST TWO INCHES BELOW GRADE. 2. THE GROUND WIRE SHALL BE IN ONE CONTINUOUS LENGTH. INSERT GROUND WIRE FROM THE BOTTOM OF THE GROUND CLAMP AND BOND OVER CLAMP BEFORE TIGHTENING. CONNECT TO SECONDARY OR SERVICE NEUTRAL ON THE POLE. PLACE GROUND WIRE ON POLE BETWEEN FACE (NOTCH SIDE) AND SERVICE NEUTRAL. 3. IDRIVE GROUND ROD IN UNDISTURBED EARTH 4. REFERENCE OF UTILITY CO. STD. CONNECT TO SECONDARY OR SERVICE NEUTRAL 1/2" PLASTIC MOULDING #2 SOLID BARE TINNED COPPER WIRE (TYP.) GRADE _. Lk GROUND ROD CLAMP 6" GROUND ROD, 5/8"0 X 8' LONG (NOT REQUIRED IF PGE GROUND ROD IS PRESENT) 5 1 HARDWARE DETAIL FOR EXTERIOR CONNECTIONS WOODEN POLE E E 0 2 IC -CRIMP DETAIL TYPE SS TYPE TA TYPE W TYPE GT 24"x36" SCALE: NTS 16 C A R D W E L D D E T A 0 L S -D '6' ECTOR CRIMP CONNI TYPE PT TYPE VN TYPE VS TYPE GY 24"x36" SCALE: NTS 13 TYPE GL TYPE NC TYPE VB TYPE GR 24"x36" SCALE: NTS PREPARED FOR x s7 AT&T 19801 SW 72ND AVE. TUALATIN, OR 97062 Vendor: '5 INFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: 21 EXPIRES: 12/31/21 .I HEREBY CERTIFY THAT THESE EDAM WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM NLY REGISTERED ENGINEER UNDER THE LAWS OFTHE STATE OF OREGON AT&T Site ID: CRAN-RWOR-EUG02-004H 16450-004H 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: GROUNDING DETAILS Sheet Number: G-1 7 LEGEND PREPARED FOR MGB MASTER GROUND BAR =_ AT&T A CADWELD 19801 SW 72ND AVE. MECHANICAL CONNECTION TUALATIN, OR 97062 — — — — #2 COPPER -TINNED BARE WIRE. ADD 1/2" WIRE COVER ON THE Vendor: BOTTOM 12 FT. MIN. 36" BELOW GRADE OR 6" BELOW FROST LINE '51NFRASTRUCTURE 2030 MAIN ST. SUITE 200 IRVINE, CA 92614 J5 PROJECT ID: P-042818 Vendor: Vendor: ANTENNA PER PLAN, TYP. NEW ANTENNA SIDE ARM MOUNT DRAWN BY: MLDV THRU-BOLT CONNECTION TO I LAA - #6 GREEN STRANDED TO CHANNEL, 3/8" DOUBLE LUG I THRU-BOLT CONNECTION, DOUBLE LUG 1 I CHECKED BY: JDM NOTE: 1 1 DETAIL SHOWS GENERAL SCHEMATIC GROUNDING REQUIREMENTS ONLY. #2 COPPER -TINNED, BARE WIRE. ADD 1/2" WIRE COVER ON THE BOTTOM 12 FT. 1 I MASTER GROUND BAR I (MGB) INSIDE ENCLOSURE I MMGB EQUIPMENT ENCLOSURE PER PLAN, TYP. 1 0 06/09/21 100% CDs REV DATE DESCRIPTION 1 #2 GREEN STRANDED TO #2 SOLID 1 DISCONNECT PER PLAN, TYP. Licensor: #2 GREEN STRANDED TO #2 SOLID 89198PE � y OREGON p O y 13,2%J� r`SVINHG�6 9 1 1 I EXPIRES: 12/31/21 POLE 1 1 .I HEREBY TSE PLAINS E PREPAREDA BYWOOD ME ORUNOERMY DIRECT ISIONANDTHAT IAM DULY REGISTERED ENGINEER UNDERTHE LAWS OF THE STATE OF OREGON ' GRADE 1 AT&T Site IF L CRAN RWOR EUG02 004H (N) GROUND ROD 5/8" x 8' LONG 16450-004H COPPER CLAD STEEL (IF REQUIRED) 160 S 14TH STREET SPRINGFIELD, OR 97477 Sheet Title: TYPICAL GROUNDING DIAGRAM Sheet Number: G-2 NOT USED TYPICAL GROUNDING DIAGRAM 24"x36" SCALE: N,�; 1