HomeMy WebLinkAboutItem 02 Street Lighting Program UpdateAGENDA ITEM SUMMARY Meeting Date:
9/20/2021
Meeting Type:
Work Session
Staff Contact/Dept.:
Brian Barnett/DPW
Staff Phone No:
541.726.3681
Estimated Time:
30 Minutes
SPRINGFIELD Council Goals:
Maintain and Improve
CITY COUNCIL
Infrastructure and
Facilities
ITEM TITLE:
STREET LIGHTING PROGRAM UPDATE
ACTION
REQUESTED: Direct the City Manager to enter into a contract with an Energy Services Company
(ESCO) via Request for Proposals/Qualifications (RFP/Q) or a cooperative
procurement process to complete a city-wide upgrade of street light fixtures to
LED.
ISSUE
STATEMENT: The City of Springfield's street light system has continually declined over the last
decade to the point where traffic maintenance staff has worked with Springfield
Utility Board to replace legacy street light technologies with LED fixtures. The
street light system is essential and relied upon by the community to illuminate
transportation systems in residential, commercial, and industrial areas. We estimate
approximately 30% of the system has transitioned to LED organically as failures
occur. In addition, there have been substantial improvements in LED technology
over the last decade along with decreasing cost. LED fixtures use substantially less
energy than legacy fixtures and require less frequent maintenance. As a result, the
City can save money by proactively replacing all legacy street light fixtures with
LED. The sooner this project is executed, the sooner this savings can be realized
and the more money the city will save. The following presentation is a proposal to
conduct a proactive full system replacement instead of reactively replacing fixtures
as thev fail.
ATTACHMENTS:
Attachment 1: Street Lighting Program Update Council Briefing Memo
Attachment 2: Street Lighting Program Update Presentation
Attachment 3: McKinstry Proposal
DISCUSSION/
FINANCIAL City Staff intends to conduct a proactive city-wide replacement of legacy fixtures
IMPACT: with LED fixtures, instead of reactively replacing fixtures as they fail. Within
approximately one year, this project will replace all non -LED street light fixtures
with LED fixtures, which will improve the quality of our lighting system along with
substantially reducing operating, maintenance, and energy costs. This project will
pay for itself through savings over approximately 10-12 years.
Staff evaluated the services ESCO can provide and determined that using an ESCO
is the best combination of service, expertise, schedule performance, and cost. An
RFP/Q may be required to access ESCO services however if a cooperative
procurement contract, also known as a piggyback contract, is available a time
consuming and costly Request for Proposal/Qualifications process is avoided and
allows the City to immediately enter a services contract.
MEMORANDUM
Date: 9/13/2021
To: Nancy Newton, City Manager
City of Springfield
COUNCIL
From: Brian Barnett, P.E., PTOE, City Traffic Engineer BRIEFING
Scott Miller, P.E., PMP, Traffic Operations MEMORANDUM
Engineer
Subject: Street Lighting Program Update
ISSUE: The City of Springfield's street light system has continually declined over the last
decade to the point where traffic maintenance staff has worked with Springfield Utility Board to
replace legacy street light technologies with LED fixtures. The street light system is essential
and relied upon by the community to illuminate transportation systems in residential,
commercial, and industrial areas. We estimate approximately 30% of the system has transitioned
to LED organically as failures occur. In addition, there have been substantial improvements in
LED technology over the last decade along with decreasing cost. LED fixtures use substantially
less energy than legacy fixtures and require less frequent maintenance. As a result, the City can
save money by proactively replacing all legacy street light fixtures with LED. The sooner this
project is executed, the sooner this savings can be realized and the more money the city will
save. The following presentation is a plan to conduct a proactive full system replacement instead
of reactively replacing fixtures as they fail.
10X"►[] 1 r Lero7:,I IIMA
MANDATE:
Maintain and Improve Infrastructure and Facilities
BACKGROUND:
Current System Information and Operational Challenges
• The City owns 4,557 street lights. 3,214 (-70%) are High Intensity Discharge
(HID) lights, consisting of Low Pressure Sodium (LPS), High Pressure Sodium
(HPS), and Metal Halide (MH) fixtures. 1,433 (-30%) are already LED, which
can be attributed to new construction, specific upgrade projects such as
Downtown Lighting improvements, and LPS lifecycle replacement.
• Springfield Utility Board (SUB) maintains this city -owned system.
• HPS and MH bulbs have a 4-5 year lifespan and require frequent maintenance to
replace bulbs and ballasts.
• LPS replacement parts (i.e. bulbs) have become boutique products and are no
longer manufactured in commodity sized quantities and are costly to purchase.
As such, when LPS fixtures fail, they must be replaced entirely. This has caused
ongoing maintenance costs to increase significantly in the last few years. The
City has chosen to replace these with LED fixtures, so that the repair cost can
also contribute towards upgrading the light. The City has already replaced over
1,100 LPS fixtures in this manner.
• Increasing Operations & Maintenance costs and increasing energy costs mean
that this aging system becomes more expensive to maintain and operate with
each coming year.
• We often rely upon citizens to report outages, leading to relatively long repair
times.
Attachment 1, Page 1 of 2
Value of upgrading to LED
• LED lights use approximately 50% less energy and need approximately 75% less
maintenance.
• Improved lighting levels will contribute to improved level and quality of light,
which will contribute to better traffic and pedestrian safety. Current light levels
often do not meet adopted city standards. (Crash Reduction Factor of 16-74%
depending on treatment.)
• LED fixtures have an average lifespan of 20 years.
• The City will save approximately $180,000 per year in energy and maintenance
costs (in today's dollars). Due to inflation and rising energy prices, this savings
will continue to increase over time.
• Project pays for itself through lower utility bills—payback period of 10-12 years.
• The cost of LED fixtures continues to decrease, and the efficiency of LED
fixtures continues to increase, with substantial improvements made in the last
few years. New fixtures are approximately 20% more efficient than just 1 year
ago. A wider range of colors is now available. In the past, 4,000 Kelvin was the
lowest color temperature available, but now 3,000 Kelvin is available. This
temperature comes with a slight loss of efficiency, but some people find this
color to be more pleasing to the eye. Recent research indicates that the best
human visual response to activity in the street or sidewalk, at street light
illumination levels, occurs at 4,000 Kelvin color temperature. As a result, staff
plans to use 4,000 Kelvin in all situations.
• We can incorporate smart lighting controls with a remote -control system. This
system will allow City staff to remotely control, monitor, meter, dim, trim, and
automatically report outages to maintenance personnel. This will reduce repair
times and will allow further energy savings if the City Council adopts a dimming
and trimming strategy. This will also allow us to address citizen complaints more
readily.
Options
City staff has researched the following replacement approaches:
1. Continue replacement as failures occur; service may be interrupted for up to
several months, higher replacement cost, inconsistent lighting types throughout
the city, creates drain on street fund Operations Division budget.
2. Conventional design, bid, and build project using either city staff or a consultant
to manage and engineer the project over approximately three years; project could
be funded by debt financing that is repaid through annual energy and
maintenance savings.
3. Partner with an Energy Service Company (ESCO) to deliver the project over
approximately 1 year; project could be funded by debt financing that is repaid
through annual energy and maintenance savings.
RECOMMENDED ACTION: Staff recommends Option 3, Partner with an Energy
Service Company (ESCO). This approach is superior in every way compared to Option
1 (timeline, cost, quality). Compared to Option 2, this approach will more efficiently
deliver a higher -quality product at a competitive price.
Attachment 1, Page 2 of 2
IiiPIOREGOH
City of Springfield
Street Lighting Program Update
Brian Barnett, P.E., PTOE, City Traffic Enginta�grent2, Page 1 of
Scott Miller, P.E., PMP, Traffic Operations Engineer
IiiPIOREGOH
Background
•City owns 4,557 street lights
3,124 (^'70%) High Intensity Discharge (HID)
Low Pressure Sodium (LPS)
High Pressure Sodium (HPS)
Metal Halide (MH)
1,433 (1%030%) already LED—new
construction, downtown lighting, LPS
replacement
Attachment 2, Page 2 of 9
IiiI!IOREGOH
Background
• Springfield Utility Board (SUB) maintains this city -
owned system
HPS and MH bulbs have a 4-5 year lifespan and
require frequent maintenance
Lack of LPS replacement parts has caused
maintenance costs to increase substantially
• Current system relies upon citizens to report
outages, leading to long repair times
Attachment 2, Page 3 of 9
IiiI!IOREGOH
FY 2021 Actual Cost Breakdown
•SUB energy bill: $224,000
• SUB operations & maintenance: $131,000
• Payment of $150,000 against $275,000
accrued deficit for SUB maintenance
($125,000 remains and continues to grow)
• City purchased repair materials: $43,000
• City contracted repairs: $103,000
• Total FY2021 Cost: $651,000
Attachment 2, Page 4 of 9
IiiPIOREGOH
Current Operational Challenges
Citizens reporting outages
• Timeliness of repairs
Increasing frequency of needed repairs
• Increasing O&M costs
• Increasing energy costs
• LPS unavailability, higher cost of maintenance & energy
for HPS & MH
Current strategy: Replace LIPS with LED as they fail
Attachment 2, Page 5 of 9
1ii1!SkOREGOH
LED Advantages
LED lights use approximately 50% less energy and need 75%
less maintenance over 20 -year lifecycle
Improved lighting levels promotes safer traffic and security—
current light levels do not meet adopted city standards in
many locations—especially important in areas with vulnerable
users like pedestrian crossings and intersections
Crash Reduction Factor of 16-74% depending on treatment
Wider range of colors now available—options include bright
white to warm yellow
Incorporate smart lighting controls, allowing remote control,
monitoring, metering, dimming, trimming, and outage
reporting
Additional energy savings available through dimming &
trimming
Attachment 2, Page 6 of 9
IiiPIOREGOH
Prospective LED Upgrade Project
F City plans to upgrade all non -LED fixtures to LED
Staff recommends to partner with an Energy Services Company
(ESCO) to deliver this project ($2.3 M estimated project cost)
ESCO performs an audit of existing infrastructure, lighting design,
construction and project management
ESCO guarantees a maximum project cost and annual energy savings
ESCO assists in coordinating financing through a local bank, or
finance internally (Intra or interfund loan, ARPA?)
High Return on Investment yields long term cost savings. Example:
Traffic Signal Incandescent to LED changeout
City will save approximately $180,000 per year in energy and
maintenance costs (at today's dollars and utility rates)
Project pays for itself through lower utility bills and operational
costs—payback period 10 years with dim & trim, 12 years without
Attachment 2, Page 7 of 9
SPRINGFIELD
L�
OREGON
$700,000
*500A00
#500,000
$400,000
$300,000
$200,000
*100,000
50
PROJECT SAVINGS V. BASELINE
0 1 7 3 4 5 6 7 9 9 14 11 12 13 14 15 16 17 19 19 20
0—Capital Contribution
Savirgs
=Post Implementation Utility Cost
=Debt Service in excess of Savings
Attachment 2, Page 8 of 9
Debt Service Supported by Savings
—Total Baseline Cost
IiiPIOREGOH
Questions?
Brian Barnett, P.E., PTOE, City Traffic Engineer
• uual IIlli iL—IU—VI.AU , 541-726-3681
Scott Miller, P.E., PMP, Traffic Operations Engineer
• smmer(«uspringfieia-or.gm, 541-726-3673
Attachment 2, Page 9 of 9
6 SPRINGFI
ELD
�RE�aQN
Aw rh
WHY McKINSTRY?
0 TEAM
91 MY EXPERIENCE
COLLABORATION
WITH UTILITES
OKNOWLEDGE OF
TECHNOLOGIES
O CITY
KNOWLEDGE
INSTALLATION
CREWS READILY
AVAILABLY
0 LOCAL TEAM
LOWEST COST &
TRANSPARENT
PROJECT OVERVIEW
• 4,557 fixtures(1,433 LED/ 3,124 HID)
• -85% cobra, -15% decorative
• SUB provides maintenance
• SUB open to using controls meter data for
billing
• Springfield has some fixtures that can be used
• Standardized on AEL Autobahn for now
• Open on Controls selection (currently ROAM)
• Springfield is AHJ for permits?
CITY OBJECTIVES
• Convert lighting and add controls
• Controls- dimming, metering, CMMS
capabilities
• Understanding utility rate structures and
collaboration with utility is important
• Quality equipment a priority
• Color temperature evaluation (3000K vs 4000K)
• Dimming schedules and guarantees aligned
• Goal to complete project in a year
• Procurement, project delivery, quality as
important as cost-effectiveness
• Other (photometric design approach)
Attachment 3, Page 1 of 15
w
y
Q
CITY OF SANDY
MCKINSTRY LESSONS LEARNED
.....................................................................................................................................................
✓ Audit strategy needs to be addressed
✓ Fixture & technology selection
✓ City preferences on photometric design standards can impact cost
✓ City preferences that can be cost drivers
✓ City preferences that can be controversial
✓ Utility collaboration
✓ Controls and hardware/software solutions
✓ Permits and Authority Having Jurisdiction (AHJ)
6 SPRINGFI
ELD
�RE�aQN
AW rh
CITY OF SANDY
AFTER__
Photometrics - multiple templates based on roadway
Controls experience, dimming schedule,
Hillsboro, OR
7100
classification and pedestrian conflict level. Included templates
GE LightGrid
Utility collaboration, Power disconnects,
for typical intersections
Decorative lighting, Utility Rebates
1000 lights and included
Lumen Equivalent & Standards - Photometrics for locations that
Controls experience
Sandy, OR
replacement of -100 wood
changed from post top lantern fixtures to cobra head, lumen
Ubicquia
Utility collaboration,
laminated poles with new poles.
equivalent & standards for other areas
Utility Rebates
Auburn, WA
2900
City Standards, Roadway Class
Sensus
Controls experience, design standards,
AHJ/permits, media support
Bellingham, WA
4000
Lumen Equivalent
Echelon
Controls experience, media support
Fife, WA
1000
Lumen Equivalent
Photocell
Multiple utilities
Redmond, WA
2000
City Standards, Roadway Class
GE LightGrid
Dimming profiles, utility collaboration
Issaquah, WA
500
Lumen Equivalent
Photocell
Decorative experience
CITY OF SANDY
AFTER__
h!
10
I
City of Springfield ,
Street Lighting
Project Overview
• 4,557 fixtures(1,433 LED/ 3,124 HID)
• —85% cobra, —15% decorative
• SUB provides maintenance
• SUB open to using controls meter data for billing
• Springfield has some fixtures that can be used
• Standardized on AEL Autobahn for now
• Open on Controls selection (currently ROAM)
• Springfield is AHJ for permits?
SPRINGFIELD
dM Attachment 3, Page 4 of 15OREGON IIlS�y
.re w morsureriy
SPRINGFIELD
AM
OREGON
City Objectives (that we heard)
✓ Convert lighting and add controls
✓ Controls - dimming, metering, CMMS capabilities
✓ Understanding utility rate structures and collaboration with utility is important
✓ Quality equipment a priority
✓ Color temperature evaluation (3000K vs 4000K)
✓ Dimming schedules and guarantees aligned
✓ Goal to complete project in a year
✓ Procurement, project delivery, quality as important as cost-effectiveness
✓ Other (photometric design approach)?
Attachment 3, Page 5 of 15
!(Z..
w morsu�reriy
Lessons Learned #1 - Audit
FX -Audit strategy needs to be addressed
• What information collected forth e project delivery (i.e. wattage, fixture type, pole height, etc)?
• What information is important to be collected for City records (i.e. hand -holds, tags, disconnects,
etc)?
• City asset tags during audit phase?
fixture and technology selection
• Performance specification to compare available products/technologies
• Controls performance evaluation, reference check, capability and reliability
• Cost model on controls is important to evaluate (up front cost vs. annuity cost)
• Decorative fixture strategy (retrofit vs. replace) considered with appropriate stakeholders
• Decorative controls strategy important to establish before control vendor/standard is selected
Attachment 3, Page 6 of 15( - in5�y
.re w morsu�reriy
CITY OF SANDY, OREGON
MALI—yEssention, LLC
Company Confidential
I�t�y
Q. -
m raorsurrer�
IA
CITY OF SANDY. OREGON
STREETLIGHT LED CONVERSION
aso,00a
5300,000
5250.000
5200.000
S150,rco
5(00,000
550,000
0
NOTEI: Sensus material first cost includes the cost of the network devices. Initial network installation and upgrade to Sensus Analystics/RNI Build -Update for logic associated with the water meter measure cost is ^S951_
10 -YR LIFE CYCLE COST COMPARISON
McKinstry Essentlon, LLC
Company Conndentiai
1 3 4 5 6 7
YEAR
�Currenr by GE �SensuS �l icquia
Attachment 3, Page 8 of 15
.,
P": 1,:d 1
3/20/2020
Fixture BOD Comparison
�Ff y
Q. -
m raorsuner�
5.111-
Alarm On Power
RF
Material Flrsf
Annual
Po[entlal
Metering Accumry
Discoveryot
On board GPS
Failure
Encryption
Warranty
Dimming
Watts
MMz
Spacing
Photocell Operation
Network
Backhaul
Cost,
Lusts
Incentive
Firture
Il0 I
7 years
$9,207/yr
b
ANSI C12200-5 pass
Yes with Dali
AES -256
Standard.
1&
7miles line of
(based on
Potential
z
+/-0.5%
Driver
Yes
Yes
with key
10 yrs
0-1tIV
Avg
9Dtl
sight
Yes
FlexNet
RF to PI -Net
$222,664
price for yrs
with
J H
manag't
Optional
2-5 only)
dimming
gum4
5years
D
99.9%Class 0.1
Yes with Bali
Yesw/Last Gasp
standard
Potential
o
Yes
AE5256-hi[
PWM, DAti, DAL120-10
O.S
NA
-
Yes
LTE CATS
LTE CATI
$113,553
$4,274/yr
with
m
+f-0.2%
Driver
Reasoning
10 years
❑phonal
dimming
B
Yes data isn't
AES and
To 1,000 FT
Poeential
ANSI C12.20
Yes with Call
Yes
el
received for
Certificate
10 years
0-10V
2
915
lip
Stand Alone
Cellular TaYes
$223,793
$0
with
+/-0.5%
Driver
hours
Authent.
Apart
The Cloud
dimming
�
aso,00a
5300,000
5250.000
5200.000
S150,rco
5(00,000
550,000
0
NOTEI: Sensus material first cost includes the cost of the network devices. Initial network installation and upgrade to Sensus Analystics/RNI Build -Update for logic associated with the water meter measure cost is ^S951_
10 -YR LIFE CYCLE COST COMPARISON
McKinstry Essentlon, LLC
Company Conndentiai
1 3 4 5 6 7
YEAR
�Currenr by GE �SensuS �l icquia
Attachment 3, Page 8 of 15
.,
P": 1,:d 1
3/20/2020
Fixture BOD Comparison
�Ff y
Q. -
m raorsuner�
Lessons Learned #2 - Design
City preference on photometric design standards can impact cost
• ESCOs often use lumen equivalents to select fixtures and deliver (easy)
• Does the city have design standards such as roadway classification, distribution types, 0&M
requirements?
• Will areas of the city require re -design or re-evaluation of fixture wattage/type?
City preferences that can be cost drivers
• Will any places require new poles?
• Will the city desire to standardize inventory of fixtures for stock or require any fixtures
customizations?
City preferences that can be controversial
• Color temperature
• Wattage, light distribution patterns, AihajAWAt s, Page 9 of 15
Q. -
m raorsurrer�
instry
ue or rom swan'
LOCATIONS WHERE EXISTING FIXTURES ARE LANTERN STYLE:
017 - Columbia Park 507- Peninsula Park
097 -Cathedral Park 666-Se€ll Park
224- Laurelhurst Park 668 - Seflwood Riverfront Park
268 - Montavi?la Park 639 - Wallace Park
271- Mt. Scott Park 868 - Woodstock Park
TOTAL QUANTITY OF FXiSTING LANTERN FIXTURES: 296
LAMP ORIENTATION WITHIN EXISTING FIXTURE: Vertical
LIGHT POLLUTION ASPECTS OF EXISTING FIXTURES:
Lamp are in vertical orientation and the lamp base connection
point is at the bottom of the fixture housing. Both increase
the amount of light pollution.
The fixture housing at the top of the lantern does reduce the
amount of light pollution.
EXISTING PATHWAY LIGHTING CONTROLS:
The pathway lighting is controlled by timeclocks. This results
in the lighting ciruc€ts being energized at dusk and de -
energized at dawn. This on/off type of strategy, as opposed
to a sensory type of strategy, results in the lighting operating
as if an occupant was pressent at all times regardless of the
actual need for lighting due to occupancy. This adds to the
light pollution of the pathway lighting.
McKinstry Essention, LLC
Company Confidential
LOCATIONS WHERE EXISTING FIXTURES ARE SHOEBOX STYLE:
061- Bloomington Park 234 - Lents Park
053 - Brentwood Park 561 - Raymond Park
112 - Ed Benedict Park 832 -Ventura Park
215 - Kenton Park 852 - Westmoreland Park
220 - Knott Park
TOTAL QUANTITY OF EXISTING SHOEBOX FIXTURES: 246
LAMP ORIENTATION WITHIN EXISTING FIXTURE: horizontal
LIGHT POLLUTION ASPECTS OF EXISTING FIXTURES:
Lamps are in horizontal orientaton and the lamp base
connection is at the top of the fixture housing. Both reduce
the amount of light pollution.
Due to the drop lens the lamp is not fully enclosed within the
fixture housing and adds to the light pollution.
EXISTING PATHWAY LIGHTING CONTROLS:
The pathway lighting is controlled by timeclocks. This results
in the Tighting cirucits being energized at dusk and de -
energized at dawn. This on/off type of strategy, as opposed
to a sensory type of strategy, results in the lighting operating
as if an occupant was pressent at all times regardless of the
actual need for lighting due to occupancy. This adds to the
light pollution of the pathway lighting.
Attachment 3, Page 10 of 15
Page I of 2
PARK PATHWAY LIGHTING
LOCATION WHERE EXISTING FIXTURES ARE ACORN STYLE:
1202 -Ed Benedict Memory Garden
TOTAL QUANTITY OF EXISTING ACORN FIXTURFS:
LAMP ORIENTATION WITHIN EXISTING FIXTURE: Vertical
LIGHT POLLUTION ASPECTS OF EXISTING FIXTURES:
Lamp are in vertical orientation and the lamp base connection
point is at the bottom of the fixture housing. Both increase
the amount of light pollution.
The fixture housing at the top of the lantern does not reduce
the amount of light pollution.
EXISTING PATHWAY LIGHTING CONTROLS:
The pathway lighting is controlled by timeclocks. This results
in the lighting cirucits being energized at dusk and de -
energized at dawn. This on/off type of strategy, as opposed
to a sensory type of strategy, results in the lighting operating
as if an occupant was pressent at all times regardless of the
actual need for lighting due to occupancy. This adds to the
light pollution of the pathway lighting.
5/21/2021
ROM Lighting Options
nsry
Q. -
m raorsnner�
Irrstry
rb as rrrr io�re,.a
Examples of Acceptable 1 Unacceptable Lighting Fixtures
Unacceptable 1 Discouraged I Acceptable
Fixtures t t produce glare and light trespass Fixtures Mat shield Me Iial source to minimize glare and light trespass
antl l0 7autitete better visional nigh
l�.l ��L•!� I � I
i
E)
Unshlelde eldool ar ar T
& Unshielded
Po fielded Wall
n
Mount F%lutea
Drop -Lens & Sag -Lens Fixtures
wl exposed bulb I refractp 1—
Unalaoided Streetlight
Unshleltled 8onards
ur,a"relded eam
U 3Jghi
Unshielded
'Perlotl' Style
R#ores
Louvered �/
Manne'sble ` -�, -vS1
9xturee Z'
h ,S
IOP'Lens Canopy
_
Urts Ided PAR
FI—lights
Table from line—do-1 Dark sky M,od,d- website
McKinstry Essention, LLC
Company Confidential
r ^c r Y
s.� Full Cutoff Fixtures
Fully
yJallpck 8 Wall
Mount Fixtures
Fully Shielded Fixtures
Full Cull Sireetipht
wiry shielded
Fully Shiight Walkwey
Barn Light Bollards
Fully Shieltled 2 1 Y ` Y
Uecorattre Fully Shlaltletl
F'utturva 'Periotl'Syle
�xt�ree
sMeldedunderCanopy
F_
Shielded l y.aimed
PAR Fl
—dfig hts
PARK PATHWAY LIGHTING
OUTDOOR LIGHTING BASICS:
1. Lighting should only be on when needed.
2. Lighting should only light the area that needs light
3. Lighting should be no brighter than necessary for the intended use.
4. Minimize blue light emissions
5. Lighting should be fully shielded (pointing downward)
The color of light is important. Both LED and metal hatide lamps contain large amounts of blue light in their
spectrum. Because blue light brightens the night sky more than any other color of light, it is important to
minimize the amount emitted. Some studies have shown that exposure to blue light at night can be harmful
to human health and endanger wildlife. Using lighting that has a color temperature of no more than 3000
Kelvins is therefore recommended. The graphic below shows the Kelvin rating for various lamp types.
0
Kalvin
-Mmparatura
Chart
The illustration to the left provides a visual guide to the differences that the design of the light fixture itself
has on light pollution (and desires to become dark sky compliant). Fixtures clouded in red show
representative sample of fixtures similar to what PAR currently has installed that are considered unacceptable
or discouraged due to light pollution concerns. The green clouded examples show similar fixtures that are
considered acceptable for light pollution concerns.
1. Based on the pathway lighting found at the sites included in the ESPC scope of work, the primary
fixture types being used are Lantern or Shoebox with a few decorative Acorn style fixtures at Ed
Benedict Memory Garden.
2. Acceptable Lantern fixtures should be fully shielded. This means the lamp should he in a horizontal
orientation within the top shield of the fixture.
3. Acceptable Shoebox fixtures should be fully shielded. This means the lamp should be in a horizontal
orientation within the top shield of the fixture.
4. Acceptable Acorn fixtures should be fully shielded. This means the lamp should be in a horizontal
orientation within the top shield of the fixture.
SUMMARY:
Converting the existing pathway lighting to 3,000 kelvin LED technology will reduce the energy consumption of
the existing lighting by 40-60% but will not drive reductions in light pollution. The new LED fixture wattage
should he selected to provide the minimum amount of light required, Installation of new fixtures will have a
longer payback but will reduce the light pollution.
lll��naaw can c�emszoos. wma�.e rix ln.e„r,.rsa,.,r�. hv.v�e,,,etoa.nl. In addition to the conversion to LED lighting a control system would allow the light level to be dimmed, further
reducing the energy consumption but improving on the light pollution impacts as well.
Attachment 3, Page 11 of 15 5/21/2021
Page 7 of 2 ROM Lighting Options
Ih7try
Q. -
m raorirurlerea
Lessons Learned #3 - Utility Collaboration and Controls
0
10 Utility Collaboration
• Important to understand current and future rate structures to inform design and product selection
• Important to work with the utility to understand what they need to meet goals (data, format, rate
justification documentation, O&M requirements, etc)
• Will existing conditions of the city require re -design or re-evaluation of fixture wattage/type?
Controls (if wanting to use controls for meter and consumption data to utility)
• Ensure utility has desired hardware and software solutions
• Utility grade meter
• Consumption data is available in acceptable format, metrics, period and granularity utility requires
• Reliability of controls is high and acceptable outage/downtime strategy exists
Attachment 3, Page 12 of 15
!(Z..
w morsu�reriy
Lessons Learned #4 - Permits and System Deficiencies
Permits and Authority Having Jurisdiction (AHJ)
• What permits will be required for the work?
• Who is the permit authority, and who are the permit stakeholders who need to sign off?
• Will a fixture replacement in any case trigger the need for existing code deficiencies (disconnects, fuses,
grounding, etc) to be corrected?
Attachment 3, Page 13 of 15
!(Z..
w morsu�reriy
dIp%/M :::: mmmmmm
% /) (J5 (9
TEAM COLLABORATION KNOWLEDGE OF CITY
EXPERIENCE WITH UTILITES TECHNOLOGIES KNOWLEDGE
.D.
INSTALLATION
CREWS READILY
AVAILABLY
SPRINGFIELD
dil
OREGON
LOCAL TEAM
Attachment 3, Page 14 of 15
LOWEST COST &
TRANSPARENT
(Z..!w morsu�reriy
Project Cash Flows - Street Lighting and Controls Retrofit
COSPro�eR Cort
Orozz vro7ex cozK $z, sa],ete
Pro? Coit ager Rebate/In
Urtly Sa �Isn9z
Total Frsl Year Savings
5176,654
OSTSrm (yrs)
Ms (Yrs)
Conrtrvctlon Perlo6 (MontM1s)
$2,590,809
Annual int ert Rate%Years)
S1 L ht R -Wit
al sa g
vroJect cost
fe $4,944[5 lstro ft
$2,54],ele
$203,780
al n
$2,590,809
rigs/Cos[
t77%
nergY rort($1tn
nergy Cos[ (%)
Simplevayback (Yrs)
13.1
m (IRR)
Rol(!!re olte9u!pment)
vv@DIt-1 Rate of ®
9o.a%
Easy]]]
omparison Metrics
N
N==
$2,353,]06
$1,003,021
N N"$450,085
b (®R) %
PR03ECT SAVINGS V. BASELINE
$]00,000
$600,000
$500,000
$.00,.00
$300,000
$200,000
$10"000
$0
MCapitallContribution 111111Post Implementation Utility Cost Debt Service SupportedbySavings 111111Savings 111111DebtlService in excess of Savings -Total Baseline Cost
10-
Nadry Slvmpz ll 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 E .00% 322.-$ 4"944'515
$ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ 0.00 $ o.00 $ .00% $
unllry an6 Operational Savings $ 18.,010 E 189,53. $ 195,220 E 201,0» $ 20],109 E 213,322 $ 219,222 E 226,31. $ 233,103 E 200,096 $ 2.],299 E 25.,]18 $ 26;359 E 220,230 $ 2]8.332 E 286,68] $ 295,388 E 300,1.6 $ 313,221 E $ 4,944,SIS
.umuiaeve sawngz g 184,014 ; 373,548 g 560,]68 ; 769,044 ; 9]6953 ; 1,190,2]6 $ 1,409,997 ; 1,636,311 g ],869,414 ; 3,109,510 $ 2,356,809 ; 2,611,52] $ 2,8]3,886 $ 3,144,116 $ 3,422,453 $ 3,]09,141 $ 4,004,429 $ 4,308,5]5 $ 4,621,846 $ 4,944,515
oral Sav!ngz $ 184,014 $ 189,534 $ 195,220 E 201,077 $ 207,109 E 213,322 $ 219,222 E 226,314 $ 233,103 E 240,096 $ 247,299 E 254,718 $ 262,359 E 220,230 $ 279,332 E 286,687 $ 295,288 E 304,146 $ 313,221 E 322,669 $ 4,944,515
on 0.00 00 0.00 00 0.00 00 0.00 00 0.00 00 0.00 00 0.00 00 0.00 00 0.00 $ 0.00 0.00 $ .00 $
$ - $ - $ - $ - $ - $ - $ - $ - $ - $
ie05avings cam Flow $ 18.,014 $ 189,534 $ 195,220 $ 201,077 $ 20],109 $ 213,322 $ 219,722 $ 226,314 $ 233,103 $ 240,096 $ 217,299 $ 254,118 $ 262,359 $ 220,230 $ 278,331 $ 286,687 $ 295,288 $ 304,146 $ 313,211 $ 322,669 $ 4,944,515
/vaYment- - - - - - --
2 13
4 1
.umulative cusromer [asn Flow g 1 ; g E g E 2 $ 2 E 2 ; 2 $ 2 E 211 24677,
t t t 2 2 2
O $ $ $ $ $ E $ E 2 $ 26;3 $220,230 $ 278,337 $ 286,6 $ 295,288 $30.,1.6 $ 313,271 E $
z 3 4 5 6 8 9 to $ 777 $x22 $ 507 $-706 2,353,]06
831,644 $1,118,331 $1,413,619 51,712,766 $z, 031,037 $ z, 353,706
covYRLCNT ® 2016 Mtllinstry Co., LLC. All H9 -reserved. InMmat/on roma/netl in this material is ronfitlential antl propNetary ro M[Xinmry. No a is ocument maY 6e reprotluretl, modified, ropled, published, w tl/stlosed, In a/fher electronic or printed MmaK In anY torm wiMout Me prior written consent o/MCKlnstry.
The__ pmvltled In tb/s dowment is no[ln[entled robe and should 770[68 ronsWed as advim wlMin Me meaning of Sechonl Se of Me securities exchange .R 011934 and the munlclpal advisor rvles of Me sec or MSR6. Menne ronsult wlM your tax, legal,w Man[ial advisors as appropr/ate.
ae�. Attachment 3, Page 15 of 15 9/3/2021