Loading...
HomeMy WebLinkAboutBuilding Correspondence 1981-09-17UI'I'Y OF SPETI}VGFIEIJI) SPRINGFIELD. OREGON E1 A7'' September 17, 1981DEPARTMENT OF PUBLIC WORKS 346 MAIN STREET 726-3753 Mr. Kevin Elfring 1223 North 35rd Street Springfield, Oregon 97477 Dear Mr. Elfring: On September 1, 1981 a service equipment inspection was made at the above address at the request of the Springfield Utility Board. The following are some, but not all, of the defects found. ELECTRICAL SAFETY The electrical system has been improperly altered and maintained and con- stitutes hazardous wiring as described in Section 1001 (e) of the Uniform Housing Code as adopted by the City of Springfield. Although the exist- ing system nay have met the standards of the code that was in effect at the tine of its installation, alterations, and/or improper maintenance re- quire corrections to be made in accordance with both the Uniform Housing Code as adopted by the City of Springfield and the current Oregon State Electrical Specialty Code (E.S.C.). Oregon Electrical Safety Law Section 22-1t0 (.b) states that electrical work performed on property that is for rent, sale or lease, sha1l be done by an electrical contractor. 1) Service drop does not have sufficient clearance over roof (8' is re-quired). National Electrical Code 230-24 (a) 2) Service conductor not continuous from service head (point of attacluuent) to the metering equipment. National Electrical Code %A-46 3) Service conduit not large enough for size and number of conductors. National Electrical Code 346-6 4) Splices in junction box are not properly installed. National Electri- ca1 Code 346-74 5) No ground bushing on conduits on load side serr,rice panel Electrical Code 250-71 (b) National 6) Our records show no inspection or permits for installation. Electri- cal Safety Law 479-550 E r- Mr. Kevin Elfring Electrical Service InsPection 1223 North 33rd Street September 17, 1981 Page 2. Please direct all inquiries to the Springfield Building Division at 726-37 53. Sincerely, 1Mtru"h,'* James Matteson Electrical InsPector 1001. 1b JM/1 s