\OCC1IPNICY lNSPBCf,ION APPLICATION
CITY O! SPRINGFIELD BUIIDING DIIESIOII
================================================================================
DATE: 8/25/94 JOB NUMBER:q t3
ADDRESS OF INSPECTTON: 610..&674N10ttr . oR 976
O\.INER: ai ar Tnn-PHONE NUMBER: r,pq,_r
OVNER'S ADDRESS:
APPLICANT:Richard S. Boettcher President of the Board of Irrc.
APPLICANT'S ADDRESS:AS
FOR ACCESS TO PROPERTY - TELEPHONE NUMBER:
pR0pgSED USE: Currently used as a group hone for 5 adults with developnental disabilities
and are wanting to increase to 6 residents.
TH]
INS
S APPL
A $35.00 INSPECTION FEE IS REQUTRED AT THE TTIIE OF APPLTCATION
ICATION FORM MUST BE SIGNED BY THE OI.INER OF THE PROPERTY TO BE
FOR OPFTCE USE O![LY
t - r -7'-l 6.iDATE PATD:
DATE OF INSPECTION:
DATE OF CERTTFICATE OF COMPLTANCE:
COMMENTS:
RECEIPT NUMBER:
DATE OF REPORT:
lq
November 16, 1994
Alvord-Taylor Inc.
290 East 17th St.
Eugene, OR 97401
Subject: occupancy Inspection at 610, 612, and 614 North 10th st.
Proposed use: Adult care Facility to expand from five to six residents
Dear Alvord-Taylor Inc.,
At your request, the_community Services DivisioniBuilding Safety conducted aninspection of the building at the above address. rhe furpose of the inspection was todetermine the suitability of the building for the p-por"a'use as indicated.
Based on the proposed occupancy, the existing conditions which are mentioned belowdo not meet the minimum nuiloing S.afety coi"..quirements. corrective measuresmust be taken prior to occupancy to irstatt, reptacel o, modify the following items inorder for the building to conform to applicabre safeiycodes: l
Rooms used for sleeping pulposes shall have.a secondary means of emergency egressdirectly to the outside tt torg-t, a door or window traving'a minimum openable area ofi;'"ltllJi,ffi.ff f:i:l"t rhe window silr above tf,e interior no;o;r;ding shau
;til:JiJ,"T;ixt:lxfocated on opposite sides of the building. Exit signs sharl be
randing at stairways shall have a dimension measured in the direction of the travel notless than the width o^f .rr" stairway. iqorr]l *. ..qui; on each sioe or a stairway,ffiff ::t
less than 34 inches o. ro* than 38 in"r,"Juuove the nosing of rreads and
Electrical requirements shall be verified through the city,s electrical inspector.
Toilet seats shall be open front in design.
Provide one 24 rated fire extinguisher for each 3000 square feet of floor area andmount three to five feet off floor level.
An approved electrically supervised fire alarm and detection system shall be provided
with audible alarm devices capable of being heard throughout the building.
Although it is not required by Oregon law at this time, we strongly recommend the
installation of a Residential Fire Sprinkler System.
The above items are requirements for the existing structure only. Other items such as
parking, paving, site improvements, sidewalks, etc., have not been addressed as part of
this inspection, and may be required. Please contact the Planning Division of this
office regarding any necessary improvements to the site.
If you need any further information or have any questions regarding the above
requirements, please contact the appropriate inspector noted below between the hours
of 8:00-9:00 r.ffi., 1:00-2:00 p.fl., or 4:00-4:30 p.m. at726-3759.
Sincerely,
Tom Marx
Structural
Inspector
Jim Hays
Electrical
Inspector
Ralph Shaw
Plumbing
Inspector
cc: Dave Puent, Building Official/Community Services Manager