HomeMy WebLinkAboutPacket, Pre PLANNER 6/12/2020Pre -Submittal Meeting Development and Public Works Department Room 616 PRE—SUBMITTAL MEETING DATE: Friday, June 19, 2020 11:00 a.m. - 12:00 p.m. r,.,W Genfer-epee Reem 616 - Pre -Submittal (Site Plan Review) #811 -20 -000114 -PRE 811-19-000130-PROJ Cherry Springs LLC Assessor's Map: 17-02-32-41 TL: 400 Address: W & Main Streets Existing Use: Vacant Applicant has submitted plans for a 129 -unit multi -family development with open space and off-street parking Planner: Melissa Cando Meeting: Friday, June 16, 2020 11:00 — 12:00 via GoToMeeting k X SITE VICINITY MAP 811 -20 -000114 -PRE Pre -Submittal Meeting 17-02-32-41 TL 400 Main & 48" Streets Cherry Springs LLC City of Springfield Development & Public Works 225 Fifth Street Springfield, OR 97477 Site Plan Review SPNINGFIEL � D Application. -(Applicant: check one) Site Plan Review Pre -Submittal: ® Ma'or Site Plan Modification Pre -Submittal: Site Plan Review Submittal: M 'or Site Plan Modcation Submittal: ❑ ifi Required Project Information (Applicant: complete this section) Applicant Name: Cherry Springs, LLC Phone: 541-485-4050 Company: Brent Lanz, Manager Email: Address: 3025 West 7th Place, Eugene OR 97402 Applicant's Rep.: Teresa Bishow, AICP Phone: 541-514-1029 Company., Bishow Consulting Email: teresa@bishowconsulting.com Address: P.O. Box 50721, Eugene OR 97405 Property Owner: Cherry Springs, LLC Phone: 541-485-4050 Company: Brent Lanz, Manager Email: Address: 3025 West 7th Place Eugene OR 97402 ASSESSOR'S MAP NO: 17-02-32-41 TAX LOT NO 5 : 400 Property Address: Vacant - No address assigned. 8.51 Proposed No. of Size of Property: Acres S uare Feet nmlllna Unift nor acre, Proposed Name of Project: Cherry Springs Description of If you are filling In this form by hand, please attach your proposal description to this application. Proposal: Proposed mult-famlly development with off-street parking and opens ace for residents. Existing Use: Vacant New Impervious Surface Coverage (Including Bldg. Gross Floor Area): sf QSi natures: Please si nand rint our name and date in thea -. -. . .In, 14 FO I, Associated Applications: ro riate box on the next a e. Signs: Pre -Sub Case No.: Date: Reviewed b : Case No.: Date: Reviewed b A lication Fee: $ Technical Fee: $ Postage Fee: TOTAL FEES: PROJECT NUMBER: Remed 1/7/14 KL 1 of 11 rjdBIISHOW INDEX WRITTEN NARRATIVE 1.0 Project Summary 2.0 Project Details 3.0 Approval Criteria and Findings 4.0 Conclusion EXHIBITS ATTACHED A. Vicinity Map B. Aerial Photograph C. County Assessor's Map D. Legal Description E. Preliminary Title Report F. Cherry Springs - Adjacent Local Streets ITEMS SUBMITTED SEPARATELY Application Form Full Size Drawing Set Application Fee 15 View of property looking northwest towards 481h Street Cherry Springs Pre -Submittal Application Page 2 of 15 Site Plan Review Written Narrative June 10, 2020 aO�BIISHOW OWM&ECT SUMMA Project Name: Project Proposal: Application Type: Project Location: Assessor's Map: Tax Lot: Size: Zoning: Plan Designation: Existing Use: Pre -Submittal Mtg Date: CHERRY SPRINGS Construct a new 129 unit multi -family residential complex on a vacant site in East Springfield Type I I - Site Plan Review East side of 48^ Street, north of Main Street 17-02-32-41 0400 8.51 Acres Mixed Use Residential (MUR) Mixed Use Vacant 6202019 City No. 811-19-000123 Associated Application: Partition Application Owner/Applicant: Cherry Springs LLC Attn: Brent Lanz 3025 West 7'^ Place Eugene, OR 97402 Applicant's Architect Rodd Hansen Rodd Hansen Architect 1551 Oak Street, Ste A Eugene, OR 97401 Rodd amarch itectu ral. com Applicant's Representative Teresa Bishow, AICP Bishow Consulting LLC P.O. Box 50721 Eugene, OR 97405 teresa®bishowconsultina. com Applicant's Landscape Arch. Jamie McGraw / Emily Brandt i.e. Engineering 809 SE Pine Street Roseburg, OR 97470 wi I leke ft eenc i neeri nc. com Applicant's Engineer Alex Palm i.e. Engineering 809 SE Pine Street Roseburg, OR 97470 aalm®ieenaineerina.com Cherry Springs Pre -Submittal Application Page 3 of 15 Site Plan Review Written Narrative June 10, 2020 rOdBIISHOW 1.0 PROJECT DETAILS 2.1 Overview Cherry Springs will provide 129 new apartments in east Springfield. Each unit will be a 2- bedroom/2-bath floor plan offering an attractive size for various households. Cherry Springs will offer on-site property management, motor vehicle parking, attractive landscaping and open space, pedestrian circulation, and bike parking. Motor vehicle access will be limited to two new private driveways on 48^ Street. Existing local streets that terminate on the east side of the property will remain closed to through motor vehicle traffic offering enhanced safety and lower traffic within Cherry Springs and preserving the character of the adjacent residential neighborhoods. The existing barricade at the terminus of "B" Street will be replaced with removable bollards for emergency access. 2.2 Property Location and Zoning Cherry Springs is located on the east side of 48^ Street with easy access to Main Street and nearby commercial services. Refer to Exhibit A — Vicinity Map and Exhibit B — Aerial Photoarach. The Euaene-Sorinafteld Metropolitan Area General Plan (Metro Plan) and the East Main Refinement Plan designate the subject property as Mixed Use Residential. Consistent with the plan designations, the subject property is zoned Mixed Use Residential MUR. The existing legal lot has frontage on both 48 Street and Main Street. A related Partition application was submitted to divide the property into two lots. Cherry Springs would have frontage on 48^ Street with the second lot having frontage on Main Street. 2.3 Existing Conditions The subject project is relatively flat with minor variations in grade. Refer to Cherry Springs Existing Conditions Map. There are numerous trees scattered throughout the site with a cluster near the northeast comer. Several trees are damaged and unhealthy. The subject property also contains grasses and obnoxious weeds. There are no identified Statewide Goal 5 natural features on the subject property. The subject property is within the mapped 5 year Time of Travel Zone and is not subject to the Drinking Water Protection Overlay District.' There is no indication of any sources of contaminants on the subject property such as underground storage tanks or prior hazardous materials handlers.2 1 City of Springfield Wellhead Protection Areas map (February 2008 delineations) 2 City of Springfield Wellhead Protection Areas map (Contaminant Source Inventory) Cherry Springs Pre -Submittal Application Page 4 of 15 Site Plan Review Written Narrative June 10, 2020 a0d BoSHCNSUOW 2.4 Key Prior Land Use Decisions The subject property was annexed to the City of Springfield sometime between 1960 and 1969.3 The Metro Plan, adopted in 1982, designated the subject property as Mixed -Use Commercial (MUC). In April 1988, the East Main Refinement Planwas adopted and the subject property was designated Mixed -Use 2A. The East Main Refinement Plan contained an adopted policy that all properties designated Mixed -Use 2A, "shall be legislatively rezoned to High Density Residential (HDR)." Consistent with the refinement plan policy, the City's zoning map was changed and the subject propertywas zoned High Density Residential (HDR). In January 2020, the Springfield City Council approved a privately -initiated amendment to the East Main Refinement Plan to allow the subject property to either retain its HDR zoning or be rezoned to Mixed Use Residential (MUR).4 At the request of the property owner, the subject property was subsequently rezoned to MUR. 2.5 Land Use and Development Requirements This is a request for Site Plan Review approval according to the Type II procedures listed in Springfield Development Code (SDC) 5.1-130 and the Site Plan Review approval criteria at SDC 5.17-125. i City of Springfield Annexation History map dated February 2014. 4 Springfield Ordinance No. 6410, City File No. 811-19-000243TYP4 Cherry Springs Pre -Submittal Application Page 5 of 15 Site Plan Review Written Narrative June 10, 2020 aOdBIISHOW 3.0 SITE PLAN APPRCIMRITERIA This section provides the applicable approval criteria for reviewing the proposed application followed by findings demonstrating compliance. Springfield Development Code provisions are shown below in bold italics. SDC 5.17-125 Criteria The Director shall approve or approve with conditions: a Type 11 Site Plan Review application upon determining that approval criteria in Subsections A. through E., below have been satisfied... A. The zoning is consistent with the Metro Plan diagram, and/or the applicable Refinement Plan diagram, Plan District map, and Conceptual Development Plan. The site is zoned Mixed Use Residential (MUR) consistent with the Mixed Use designation on the Metro Plan diagram and in the East Main Street Refinement Plan. There are no proposed changes to the zoning for the site. B. Capacity requirements of public improvements, including but not limited to, water and electricity; sanitary sewer and stormwater management facilities; and streets and traffic safety controls shall not be exceeded and the public improvements shall be available to serve the site at the time of development, unless otherwise provided for by this Code and other applicable regulations. The Development & Public Works Director or a utility provider shall determine capacity issues. Approval of this proposal would allow for construction of a 129 -unit multi -family residential complex consisting of 16 two-story apartment buildings along with a leasing office, driveways and parking areas, site landscaping, open spaces, and vegetated stormwater management facilities on about 6.26 acres. For all public improvements, the applicant will retain a private professional civil engineer to design the site improvements in conformance with City codes, this decision, and the current Engineering Design Standards and Procedures Manual (EDSPM). The private civil engineer also will also provide construction inspection services. Water and Electricity Improvements Per SDC 4.3-130, each development area is to be provided with a water system having sufficiently sized mains and lesser lines to furnish adequate supply to the development and sufficient access for maintenance. Springfield Utility Board (SUB) coordinates the design of the water system within Springfield city limits. The applicant proposes to connect to the existing public water line located in 48^ Street in two locations looping the public water system through the development. Multiple fire hydrants will be installed throughout the development to provide fire protection to all buildings and structures. Cherry Springs Pre -Submittal Application Page 6 of 15 Site Plan Review Written Narrative June 10, 2020 rod BoSHCNSUOW SUB Water advises that all non-residential domestic and irrigation services, and all residential water services with lawn sprinkler systems, require a reduced pressure backflow assembly. All fire services require a minimum of a double check detector assembly with a detector meter on a bypass. The assemblies are required to be installed above ground and adjacent to the water service. The applicant will contact SUB Water Division's Backflow Prevention Specialist at (541) 726-2396 to discuss the backflow prevention and fire protection service requirements. Per SDC 4.3-125, wherever possible all utility lines shall be placed underground. Additionally, vaults and transformers for utility connections along the street frontage should be screened from view or placed out of sight at the side or rear of buildings. There are existing overhead power lines along the western boundary of the subject property as shown on Cherry Springs Existing Conditions Map. The overhead wires on 48^ Street are backbone distribution lines and are not required to be placed underground. The overhead power lines will be unaffected by the proposed development. Within the development area, the applicant is proposing to install all new utility lines underground. As shown on Cherry Springs Water & Sewer Layout, the existing public water and sanitary sewer lines can be extended to adequately serve the proposed development. Sanitary Sewer Per SDC 4.3-105.A, the applicant proposes to install sanitary sewers to serve the new development and to connect the development to existing mains. Additionally, installation of sanitary sewers will provide sufficient access for maintenance activities. The nearest public sewer main that can provide gravity service to the entire development site is located in 48^ Street at the far northwest corner of the site. The applicant proposes to extend a new public sewer main down 48^ Street to provide service to the site. The public main will also be brought into the site as needed to provide service. The existing sewer main located adjacent and east of the site in B Street is not deep enough to provide gravity service to the site. The applicant will make any field adjustment as necessary during construction to avoid any new connection points that will require excavations into 48^ Street and utilize existing connection points that may not be located exactly as shown on the plans. Per Chapter 3.02.4.A of the City's EDSPM and Section 3.4 of the City of Eugene Stormwater Management Manual, solid waste storage areas shall be covered and hydraulically isolated from potential stormwater runoff, and directed to the sanitary sewer system. To meet this requirement, the applicant is proposing to construct two trash & recycle enclosures that are covered, hydraulically isolated, and equipped with floor drains that are plumbed to the sanitary sewer system (Sheet XXX - Site Plan and Sheet XXX - Utility Plan). Stormwater Management (Quantity) Per SDC 4.3-110.6, the Approval Authority shall grant development approval only where adequate public and/or private stormwater management systems provisions have been made as determined by the Development & Public Works Director, consistent with the EDSPM. SDC Cherry Springs Pre -Submittal Application Page 7 of 15 Site Plan Review Written Narrative June 10, 2020 a0d BoSHCNSUOW 4.3-110.D requires that runoff from a development shall be directed to an approved stormwater management system with sufficient capacity to accept the discharge. SDC 4.3-110.E requires new developments to employ drainage management practices that minimize the amount and rate of surface water runoff into receiving streams, and that promote water quality. To comply with Sections 4.3-110.D & E, the applicant proposes to direct stormwater runoff from the site into a series of stormwater treatment bio-swales and detention basins prior to discharging the stormwater into the public system. The bio-swales and detention basins will function to make the stormwater discharge from the site mimic pre-existing conditions. Stormwater from the site currently drains from east to west and into the existing drainage Swale located on the west side of 48^ Street. The existing drainage pattern will be matched post construction. Stormwater Management (Quality) Under Federal regulation of the Clean Water Act (CWA), Endangered Species Act (ESA), and National Pollutant Discharge Elimination System (NPDES), the City of Springfield has obtained a Municipal Separate Storm Sewer System (MS4) permit. A provision of this permit requires the City to demonstrate efforts to reduce the pollution in urban stormwater to the Maximum Extent Practicable (MEP). Federal and Oregon Department of Environmental Quality (ODEA) rules require the City's MS4 plan to address six "Minimum Control Measures". Minimum Control Measure 5, "Post - Construction Stormwater Management for New Development and Redevelopment", applies to the proposed development. Minimum Control Measure 5 requires the City of Springfield to develop, implement and enforce a program to ensure the reduction of pollutants in stormwater runoff to the MEP. The City also must develop and implement strategies that include a combination of structural or non-structural Best Management Practices (BMPs) appropriate for the community. Minimum Control Measure 5 requires the City of Springfield to use an ordinance or other regulatory mechanism to address post -construction runoff from new and re -development projects to the extent allowable under State law. Regulatory mechanisms used by the City include the SDC, the City's Engineering Design Standards and Procedures Manual and the Stormwater Facilities MasterPlan (S FM P). As required in SDC 4.3-110.E, "a development shall be required to employ drainage management practices approved by the Public Works Director and consistent with the Metro Plan policies and the Engineering Design Standards and Procedures Manual." Section 3.01 of the City's EDSPM states the Development & Public Works Department will accept, as interim design standards for stormwater quality, water quality facilities designed pursuant to the policies and procedures of the City's EDSPM and the City of Eugene Stormwater Management Manual. Sections 3.02 of the City's EDSPM states all public and private development and redevelopment projects shall employ a system of one or more post -developed BMPs that in combination are designed to achieve at least a 70 percent reduction in the total suspended Cherry Springs Pre -Submittal Application Page 8 of 15 Site Plan Review Written Narrative June 10, 2020 a0d BoSHCNSUOW solids in the runoff generated by the development. Section 3.03.4.E of the manual requires a minimum of 50 percent of the non -building rooftop impervious area on a site shall be treated for stormwater quality improvement using vegetative methods. Prior to Final Site Plan approval, the applicant will provide an Operations & Maintenance Plan to the City for review to ensure the long-term maintenance and operation of the proposed Stormwater System, consistent with maintenance criteria required by EDSPM 3.03.1. The plan will designate maintenance responsibility for operating and maintaining the system to the property owner of the site. Streets and Traffic Safety Controls SDC 4.2-105.G.2 requires that whenever a proposed land division or development will increase traffic on the City street system and that development has unimproved street frontage abutting a fully improved street, that street frontage shall be fully improved to City specifications. Along the western site frontage, 48^ Street is developed with two travel lanes with street lights on the east side and a ditch on the west side. The street does not have a bike lane, street trees, or a sidewalk along the subject property's frontage. Due to the existence of the drainage ditch on the west side of the road, it is not feasible to provide full street improvements within the existing public right-of-way. The applicant proposes to design a multi -modal bike/pedestrian path on the east side of 48^ Street. The applicant proposes to install new street trees along the 48th Street frontage in accordance with SDC 4.4-105.B.2. The applicant is proposing to place the street trees close to the overhead power lines in the existing public right-of-way. The applicant proposes smaller street tree species so that when they mature, they still fit under the overhead power lines. The proposed transportation facilities would be adequate to accommodate the anticipated vehicular and pedestrian traffic patterns generated by the development in a safe and efficient manner. Refer to Exhibit F — Cherry Springs Adjacent Local Streets. C. The proposed development shall comply with all applicable public and private design and construction standards contained in this Code and other applicable regulations. Standards in Chapter 3 applicable to the proposed project that are not addressed elsewhere in this report are listed below. Chapter 3 Land Use District Standards Section 3.2-615 Base Zone Mixed Use Development Standards Section 3.2-625 Mixed -Use Development Standards - General Section 3.2-630 Mixed -Use Development Standards — Specific Section 3.2-240 Multi -Unit Design Standards Cherry Springs Pre -Submittal Application Page 9 of 15 Site Plan Review Written Narrative June 10, 2020 r0dBIISHONG W TABLE 1 - Mixed Use Development Standards SDC Subject Standard Proposed Complies 3.2-615 Lot Coverage Maximum 45% Lot Coverage Q 50% ??? Bldgs — Q 24% Vehicular Areas— a 26% 3.2-615 Building Height 60 ft a 24 ft at top of pitch roof YES 3.2-625.A Building Design Architectural features e.g. Architectural features YES offsets, windows, entry include windows, entry treatments, varied exterior treatments, and trim and building materials corner boards 3.2-625.6 Building Orientation Buildings oriented to street Buildings are oriented to ??? /Maximum Setbacks along at least 50% of street about %ofthe frontage to enhance street frontage along 48' pedestrian comfort, Street. convenience and safety. 3.2-625.0 Weather Protection Awnings and canopies Main building entrances YES provide shelter for are covered providing pedestrians. shelter. 3.2-625.D Landscaping and Per SDC 4.4-100 and SDC Landscape Plan to be ? Screening 4.4-110 submitted at a later date. 3.2-625.E Street Connectivity Streets shall connect to Per SDC 3-2-605- No YES and Internal adjacent neighborhoods — street connectivity is Circulation maximum block perimeter of proposed to preserve 1,400 feet. adjacent existing neighborhood. Pedestrian paths and sidewalks shall connect all Proposed multi -modal path building entrances with each on 4P Street and internal other and with adjacent pedestrian circulation public right-of-way. connecting to adjacent public ROW. 3.2-625.F Neighborhood Compliment character of Architectural features YES Compatibility neighborhood including: include lap siding (w/6" 1) architectural compatibility, exposed) (fiber cement), 2) lighting, trim and corner boards, 3) site -obscuring hardi-panel 8" grooves, landscaping, pitch roof; shielded lighting 4) screen mech. equipment. and landscaping will provide screening; no exposed mech. equip. 3.2-625.G Pedestrian Project> 50,000 sq. ft. shall _ pedestrian amenities ??? Amenities provide 4 pedestrian to be shown on Landscape amenities Plan 3.2- Preserve Residential Min. 80% gross floor area for 100% of gross floor area is YES 630.C.1 Land Supply housing; residential priorto for housing and the or concurrent with non- apartment manager's residential development office; development will occur priorto development of new lot facing Main St. 3.2- Minimum/Maximum 20 units per gross acre if 20.6 units per gross acre YES 630.C.2 Residential only housing -12 units per of land for planned for Densities gross acre if mixed uses future residential lot. Cherry Springs Pre -Submittal Application Page 10 of 15 Site Plan Review Written Narrative June 10, 2020 rod BoSHCNSUOW TABLE 2 — Multiple Family Standards SDC Subject Standard Proposed Complies 3.2-240.D.1 Building Only applies to streets with Not applicable -4P Street NA Orientation existing or planned on -street does not have any on -street parking. parking. 3.2-240.D.2 Building Continuous horizontal distance Maximum horizontal YES Form does not exceed 160 feet distance of 112 ft 3.2-240.D.3 Transition a. Bldg setback on same side of No proposed buildings are NA and street as single-family home is on the same street as Compatibility similar to that of the nearest adjacent single-family residence. homes. b. 25 -foot buffer along LDR 25 -foot buffer along LDR YES c. Bldg Height Step Down by Bldg heights do not exceed YES LDR 25 ft d. Bldgs within 50 ft of LDR shall Blgs within 50 ft of LDR YES not have continuous horizontal have maximum horizontal distance exceeding 120 ft distance of 112 ft 3.2-240.D.4 Storage a. Min. 112 cubic ft of enclosed Each dwelling unit has 144 YES storage separate from each cubic feet of enclosed dwelling unit. storage accessed from the private patio or balcony. b. Trash receptacles are screened Trash receptacles are YES screened and covered. c. No trash receptacles in front yard setbacks or within 25 feet of No trash receptacles are LDR. within front yard setbacks YES or 25 ft of LDR. d. Ground -mounted equipment underground, where practicable There are no ground - or placed to minimize visual mounted equipment on the YES impact and screened. site. 3.2-240.D.5 Open Space a. General — Min. 15% open ??? ??? space b. Common Open Space ??? ??? - Min. 0.25 SF per 1.0 SF gross residential floor space - At least 500 SF with no dimension less than 15 ft - Max 15% on slopes greater than 25% - Min 250 SF active recreation per 20 units - Children's play areas prohibited in setback or transition areas. - Min. 50% of common open space in landscaping Cherry Springs Pre -Submittal Application Page 11 of 15 Site Plan Review Written Narrative June 10, 2020 aO�BIISHOW Cherry Springs Pre -Submittal Application Page 12 of 15 Site Plan Review Written Narrative June 10, 2020 c. Private open space is optional Each dwelling unit has 72 YES —must be directly accessible from SF of private open space the dwelling unit directly accessible from the unit. 3.2-240.D.6 Landscaping a. Min 15% of site shall be .? ??? landscaped b. Street trees min. 2 inches in ??? ??? caliper between curb and sidewalk every 30 linear ft c. Fences in front yards limited to No fences are proposed in YES 3 feet front yards. d. Native and/or drought tolerant ??? ??? plants encouraged 3.2-240.D.7 Pedestrian a. Continuous internal sidewalks Pedestrian circulation is YES Circulation provided at least 5 feet from b. Min. 5 feet from dwellings dwellings c. Internal sidewalk system shall Sidewalk system connects ??? connect all abutting streets to to 4P Street. primary building entrances d. Internal sidewalk system Internal sidewalk system ??? connects all buildings to parking provides connectivity areas, bicycle parking, storage between different uses and areas, all common areas, and public sidewalk on 48^ St abutting public sidewalks. e. Min. 5 foot wide paved Internal sidewalks are YES sidewalks typically 6- feet wide f. Internal sidewalks clearly Internal sidewalks are YES marked when crossing streets or marked at major crossings parking aisles, and ADA and will be ADA compliant compliant g. Internal sidewalks parallel and ??? ??? abutting vehicular circulation areas shall be raised or separated by a curb or other barrier. If raised, curb ramps required. h. Internal sidewalks shall be ??? ??? lighted to a min. 2 foot-candles 3.2-240.D.8 Parking a. Parking to the side or rear of On 486 St -no parking YES buildings. areas are between the building and the street. Cherry Springs Pre -Submittal Application Page 12 of 15 Site Plan Review Written Narrative June 10, 2020 aO�BIISHOW Cherry Springs Pre -Submittal Application Page 13 of 15 Site Plan Review Written Narrative June 10, 2020 b. Shielded parking lot lighting All parking lot lighting to be YES shielded per city code. c. Planter islands every 8 parking Planter islands to be YES spaces — min. 6 feet wide, provided every 8 parking excluding curb; 1 shade tree and spaces and landscaped. ground cover d. Min. 6 -foot wide planter shall ??? ??? screen parking area from living area windows planted with mix of trees, shrubs, and ground cover. e. Internal sidewalks between Internal sidewalks are YES parking lots and building provided between all entrances parking lots and building entrances f. Provide parking stall bumpers orwidened adjacent sidewalk or Protection will be provided. YES planter 2 feet, sidewalks and planters shall be protected with 6 inch curbs. g. On comer lots, parking shall Not Applicable. Lot is not NA not be located within 30 feet of on a corner. the intersection h. Min 5 -foot wide planter along Perimeter landscaping to YES perimeter of parking area next to be provided per code a property line or public right-cf- way. i. Decorativewalls optional in Nowalls are proposed. NA place of hedge in Subsection h. j Parking area landscaping ??? W" reduces stormwater runoff k. Bicycle parking provided Bike parking to be provided YES per code. 3.2-240.D.9 Vehicular a. On-site driveways or private Per 3-2-605 - No street YES Circulation streets connect with public streets connectivity is proposed to abutting the site. preserve adjacent existing neighborhood. Emergency b. Shared driveways provided vehicle access provided at whenever practicable end of B Street. c. Parking areas shall be No shared driveways or accessed from alleys if present alleys are proposed. Cherry Springs Pre -Submittal Application Page 13 of 15 Site Plan Review Written Narrative June 10, 2020 a0d BoSHCNSUOW Standards in Chapter 4 applicable to the proposed project are listed below. Chapter 4 Development Standards Section 4.4-100 Landscaping, Screening and Fencing Section 4.5-100 On -Site Lighting Section 4.6-100 Vehicle Parking, Loading, and Bicycle Parking The applicant intends to comply with the above standards in Chapter 4. Compliance is demonstrated on Sheet XX— Site Plan and Sheet XX— Landscape Plan. D. Parking areas and ingress -egress points have been designed to: facilitate vehicular traffic, bicycle and pedestrian safety to avoid congestion; provide connectivity within the development area and to adjacent residential areas, transit stops, neighborhood activity centers, and commercial, industrial and public areas; minimize curb cuts on arterial and collector streets as specified in this Code or other applicable regulations and comply with the ODOT access management standards for State highways. The proposed project is designed to facilitate safe vehicular, bike and pedestrian circulation Motor vehicle access will consist of two private driveways on 48^ Street that provide ample sight distance for motorists and adequate vision clearance where private driveways connect to the public street. Except for emergency vehicles, no vehicular access is proposed to adjacent local public streets to help preserve the existing residential neighborhoods. For further information, please refer to Exhibit F — Cherry Springs — Adjacent Local Streets In accordance with SDC 4.2-120.C, site driveways are designed to allow for safe and efficient vehicular ingress and egress as specified in Tables 4.2-2 through 4.2-5, the City's EDSPM, and the City's Standard Construction Specifications. Ingress -egress points are planned to facilitate traffic and pedestrian safety, avoid congestion, and minimize curb cuts on public streets. The applicant is proposing two new ADA -compliant driveway approaches to serve the subject property. The driveways will consist of a vertical face curb, gutter and sidewalk. Each driveway will be 24' wide with an 18' driveway throat depth for approximately 71 feet. The proposed site driveways meet the City's dimensional requirements for multi -family residential driveway approaches and separation spacing from local street intersections. The proposed site plan provides for pedestrian connections from the multi -modal path on 48^ Street to an interior sidewalk system. The interior sidewalks provide safe and convenient connections between the parking areas, the common areas, and dwelling units. Due to the existing right-of-way on 48' Street and the location of the 48^ Street channel along the west side of the street, the applicant proposes a multi -modal path for both bikes and pedestrians versus the standard city street design of an on -street bike lane and separated sidewalk. The multi -modal path will provide a safe and convenient way for bicyclists and pedestrians to use 48^ Street as a route to nearby commercial services, areas of employment, and other neighborhood activity areas. Cherry Springs Pre -Submittal Application Page 14 of 15 Site Plan Review Written Narrative June 10, 2020 aO�BIISHOW E. Physical features, including, but not limited to: steep slopes with unstable soil or geologic conditions; areas with susceptibility of flooding; significant clusters of trees and shrubs; watercourses shown on the Water Quality Limited Watercourse Map and their associated riparian areas; wetlands; rock outcroppings; open spaces; and areas of historic and/or archaeological significance, as may be specified in Section 3.3-900 or ORS 97.740-760, 358.905-955 and 390.235-240, shall be protected as specified in this Code or in State or Federal law. The subject property does not contain any steep slopes or known unstable soil or geological conditions. The Natural Resources Study, the National Wetlands Inventory, the Springfield Wetland Inventory Map, Wellhead Protection Overlay and the list of Historic Landmark Sites do not identify any known natural features or resources on the property thatwarrant protection. The City of Springfield Water Quality Limited Watercourse Map does not show any watercourses on the subject properly.' On the west side of 48^ Street the map indicates that the 48^ Street Channel is a 'Tributary to Water Quality Limited Watercourse". The map also indicates that the subject property does not contain any areas designated by FEMA as in the Floodplain or Floodway. the applicant proposes to direct stormwater runoff from the site into a series of stormwater treatment bio-swales and detention basins prior to discharging the stormwater into the public system. The bio-swales and detention basins will function to make the stormwater discharge from the site mimic pre-existing conditions. The applicant will monitor construction activities to ensure the protection of groundwater. Following completion of the proposed development, the applicant will maintain the private stormwater facilities on the site to ensure the continued protection of surface water and groundwater resources. The proposed Cherry Springs Site Plan Review complies with applicable approval criteria and SDC standards. The application provides substantial evidence to support approval of the application. If you have questions or need further information, please contact Teresa Bishow at 541-514- 1029 or via e-mail at teresatDbishowconsultinc.com. Sincerely, Teresa i3ishow END OF WRITTEN STATEMENT ' Water Quality Limited Watercourse map adopted by Council Ordinance 6021, 7/15/2002. Cherry Springs Pre -Submittal Application Page 15 of 15 Site Plan Review Written Narrative June 10, 2020 CHERRY SPRINGS PROPOSED LOT LAYOUT Property Information: Assessor Map #: 17023241 Taxlot #: 400 Layout Provides: Units: 129 Acres (residential only): 7.3 Units/acre: 20.6 Parking: 206 spaces Residential Lot Coverage: Approximate SF % pasldental Rea 917,&A4 100.04' L overage 75,805 23.9%eM1ibike Inddtl.d) 99,140 591 F ----.moi nL --mowtii tp9 -,AM PROPOSED NEW LOT BOUNDARY PROPOSED FENCE OR LANDSCAPE SCREENING C STREET BEAVER STREET CHERRY SPIUNGS PRELIMINARY LOT LAYOUT L. T Rev. Date On Desui tion r awa 3: CHERRY SPRINGS PRELIMINARY SITE LAYOUT Property Information: Assessor Map #: 17023241 Taxlot #: 400 Layout Provides: Units: 129 Acres (residential only): 7.3 acres Units/acre: 20.6 Parking: 206 spaces Residential Lot �e�FFEA 8 a i s cC c 7 Cccc17 ccc 8 20 2 —12 BIKE PARKING Coverage: S 3 Approximate SF Y Resld,td Area 31,883 100.P/ Ruiltlln8 (Avampa 7- 86, 239% 5 Farldng &Vehicle Ga,pr�gp (bike pailtiny nol lncWdetlJ 32140 268 8-PLEX HLTInppALPAH ProP�Eo ACTIVE RECREATION AREA 8 8 APPROX. EXISTING EDGE OF ASPHALT 10' MULTI -MODAL PATH WITH 2' BUFFER PROPERTY BOUNDARY j I TYPICAL BUILDING DIMENSIONS. �1,s� TYPICAL 8-PLEX T 0 60 120 Feel CHERRY SPRINGS PRELIMINARY SITE LAYOUT �e�FFEA 8 a i s cC c 7 Cccc17 ccc 8 20 2 —12 BIKE PARKING 02 S 3 5 M M M T/R APPROX. EXISTING EDGE OF ASPHALT 10' MULTI -MODAL PATH WITH 2' BUFFER PROPERTY BOUNDARY j I TYPICAL BUILDING DIMENSIONS. �1,s� TYPICAL 8-PLEX T 0 60 120 Feel CHERRY SPRINGS PRELIMINARY SITE LAYOUT EXISTING BARRICADE TO REMAIN 111Ifdd:1t — EXISTING BARRICADE TO REMAIN BEAVER STREET REPLACE EXISTING BARRICADE WITH REMOVABLE BOLLARDS FOR EMERGENCY USE ONLY B STREET EXISTING BARRICADE TO REMAIN A STREET �e�FFEA 8 a i s cC c 7 Cccc17 ccc 8 20 2 —12 BIKE PARKING Feu Ee PLE 30 1 7 ccccc 3 5 ENCLOSED TRASH CCCCCCC s T/R 5 8-PLEX HLTInppALPAH ProP�Eo ACTIVE RECREATION AREA 8 8 8 8 36 BICYCLE PARKING 8 8 5 5 I I U n 8 8 L J ENCLOSED TRASH 48 BIKE PARKING -PLEX F -PLEX 'e 1 8 T 8 8 8 8 8 EXISTING BARRICADE TO REMAIN 111Ifdd:1t — EXISTING BARRICADE TO REMAIN BEAVER STREET REPLACE EXISTING BARRICADE WITH REMOVABLE BOLLARDS FOR EMERGENCY USE ONLY B STREET EXISTING BARRICADE TO REMAIN A STREET CHERRY SPRINGS WATER & SEWER LAYOUT Property Information: Assessor Map #: 17023241 Taxlot #: 400 8" WATER LINE 8" SEWER LINE A S CC M M M CHERRY SPRINGS PRELIMINARY LOT LAYOUT Rev. Date On Desari tion r c $FRINQ$ 1EXI$TI L,--j-j L NO CONDITION$ / I / 7II \— / I I \ \ / 1 / \ / �//E 346.6'± —di — --- EXISTING STS CI _ iSTS CI STS MH GUTTER: 494.03 MAIN ST GUTTER: 494.58 RIM: 494.14 10" INV OUT (W): 492.99 MCKENZIE HWY 10" INV OUT (W): 493.01 48" INV IN (E): 484.29 TELEPHONE (OVERHEAD) EXISTING HWY 126 EXISTING FIBER OPTIC EXISTING OVERHEAD WIRE EXISTING EDGE OF ASPHALT EXISTING FENCE/FENCE POST EXISTING Nei Springfield EXISTING CONCRETE " MANHOLE AS NOTED EXISTING oarwxc o . e.e.a \ x>,a. eng.0 1 ( \ 1 1 \ \ \ \ \I I TELEPHONE PEDESTAL I LIGHT POLE EXISTING WATER SERVICE EXISTING WATER VALVE BOX EXISTING BOLLARD EXISTING SIGN EXISTING xu.o„ate EXISTING MAILBOX EXISTING POWER BOX EXISTING GUY WIRE J l L9 Springfield BEAVER ST oxl.r..nee��. / C" ST \ I \\ \\ 1 \ I BACKBONE 1 \ PROJECT DISTRIBUTION 1 \ \ POWERLINE xr'SaY / I / 7II \— / I I \ \ / 1 / \ / �//E BACKBONE "A" ST—PRIVATE DISTRIBUTION NOT A PUBLIC RIGHT—OF—WAY POWERLINE \ it \ 167.2'± ( I I \ \\ AREA TO BE PARTITIONED \\ ---4 g f'ssg \\ \ I yl I II I I \ 1 I 1 rn J 11 178.4'+ — MAJOR —di — --- EXISTING STS CI EXISTING iSTS CI STS MH GUTTER: 494.03 MAIN ST GUTTER: 494.58 RIM: 494.14 10" INV OUT (W): 492.99 MCKENZIE HWY 10" INV OUT (W): 493.01 48" INV IN (E): 484.29 TELEPHONE (OVERHEAD) EXISTING HWY 126 EXISTING FIBER OPTIC EXISTING OVERHEAD WIRE EXISTING EDGE OF ASPHALT EXISTING FENCE/FENCE POST EXISTING Nei Springfield EXISTING CONCRETE " MANHOLE AS NOTED EXISTING oarwxc o . e.e.a in x>,a. eng.0 EXISTING WATER VALVE EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING LIGHT POLE EXISTING WATER SERVICE EXISTING WATER VALVE BOX EXISTING BOLLARD EXISTING SIGN EXISTING xu.o„ate EXISTING MAILBOX EXISTING POWER BOX EXISTING GUY WIRE J l L9 Springfield BEAVER ST oxl.r..nee��. \ I \ ems 1 PROJECT LOCATION I xr'SaY 3 [3dnwe 4 RA in \ e— / .__ Epri� 45 opprine I NTS L6 ---- i 1 I I 1 I I \ I I \ / 1 I I >z` STS MH / \ \ SS MH RIM: 494.33 / RIM: 496.28 12" INV IN (N): 486.66 / \ 10" INV IN (W): 491.36 m 12" INV IN (E): 486.55 / 10" INV OUT (E): 491.36 — 12" INV IN (S): 486.74 / ± 12" INV OUT (W): 486.59 S v 1 \1 I 1 I \I � I \ I I / / I i I � I / \ \ I 1 I W BACKBONE "A" ST—PRIVATE DISTRIBUTION NOT A PUBLIC RIGHT—OF—WAY POWERLINE \ it \ 167.2'± ( I I \ \\ AREA TO BE PARTITIONED \\ ---4 g f'ssg \\ \ I yl I II I I \ 1 I 1 rn J 11 178.4'+ SSMH g RIM: 495.57 10" INV IN (W): 490.45 10" INV OUT (E): 490.41 0 m 0 Na • ■ I LEGEND: CONTOUR — MAJOR —di — --- EXISTING STS CI EXISTING iSTS CI STS MH GUTTER: 494.03 MAIN ST GUTTER: 494.58 RIM: 494.14 10" INV OUT (W): 492.99 MCKENZIE HWY 10" INV OUT (W): 493.01 48" INV IN (E): 484.29 TELEPHONE (OVERHEAD) EXISTING HWY 126 SSMH g RIM: 495.57 10" INV IN (W): 490.45 10" INV OUT (E): 490.41 0 m 0 Na • ■ I LEGEND: CONTOUR — MAJOR CONTOUR — MINOR EXISTING PROPERTY BOUNDARY EXISTING STORM SEWER EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING POWER (OVERHEAD) In_ POWER (UNDERGROUND) EXISTING TELEPHONE (OVERHEAD) EXISTING TELEPHONE (UNDERGROUND) EXISTING FIBER OPTIC EXISTING OVERHEAD WIRE EXISTING EDGE OF ASPHALT EXISTING FENCE/FENCE POST EXISTING Nei Springfield EXISTING CONCRETE " MANHOLE AS NOTED EXISTING oarwxc o . e.e.a in x>,a. eng.0 EXISTING WATER VALVE EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING LIGHT POLE EXISTING WATER SERVICE EXISTING WATER VALVE BOX EXISTING BOLLARD EXISTING SIGN EXISTING xu.o„ate EXISTING MAILBOX EXISTING POWER BOX EXISTING GUY WIRE oxer” L9 Springfield x oxl.r..nee��. ems " PROJECT LOCATION xr'SaY 3 [3dnwe 4 RA e— .__ Epri� 45 opprine VIC MAP NTS SSMH g RIM: 495.57 10" INV IN (W): 490.45 10" INV OUT (E): 490.41 0 m 0 Na • ■ I LEGEND: CONTOUR — MAJOR CONTOUR — MINOR EXISTING PROPERTY BOUNDARY EXISTING STORM SEWER EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING POWER (OVERHEAD) EXISTING POWER (UNDERGROUND) EXISTING TELEPHONE (OVERHEAD) EXISTING TELEPHONE (UNDERGROUND) EXISTING FIBER OPTIC EXISTING OVERHEAD WIRE EXISTING EDGE OF ASPHALT EXISTING FENCE/FENCE POST EXISTING ASPHALT EXISTING CONCRETE EXISTING MANHOLE AS NOTED EXISTING CATCH BASIN EXISTING CLEANOUT EXISTING WATER VALVE EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING LIGHT POLE EXISTING WATER SERVICE EXISTING WATER VALVE BOX EXISTING BOLLARD EXISTING SIGN EXISTING FIRE HYDRANT EXISTING MAILBOX EXISTING POWER BOX EXISTING GUY WIRE ° ii a ° f ' no tel'• —NC STS CI ``— GUTTER: 495.16 —" 10" INV OUT (W): 493.55 STS MH 0' 20' 40' 80' RIM: 495.16 48" INV OUT (W): 487.48 1 SCALE:1" = 40' 809 SE Pine Street Roseburg, Oregon 97470 PHONE (541) 673-0166 Le FAX (541) 440-9392 PROJECT NO. 2923-07 / DWG BY: DTM