Loading...
HomeMy WebLinkAboutPermit Electrical 2002-05-02SPRINGFIELD Job# 02-00509-01 RESIDENTIAL PERMIT City Of Springfield Gommunity Services Division Building Safety Page 1 of2 Job Number: 02-00509-01 Office:726-3759 Inspection Line: 726-3769 Tax Lot#: 01900 Subdivision: €h, 225 Fifth Street Springfield, OR97477 Location Of Proposed Site: 4733 Union Ter Spr AssessorsMap#: 18020512 Lot: Block: Addition: clTY oF SPRINGF7ELD, OREGON Owner: Dorothy Mitchell Address: 4733 Union Ter Scope Of Work: Single Family Residence Phone Number: City/State/Zip: Repair 541-747-8653 Springfield, OR 97478 Value: $4,500 t0 o,Repair wing damaged roof OK'd per DM050202 Contractor Northwest Rebuilders lnc 97448 Mortier Engineering 1245Pearl Street, Eugene, OR ,1Contractor Type GeneralContr Engineer Phone 541-689-6449 541 -484-9080 h 91992 Hwy 99 Unit D, Junction on0t \ne e- 97 1ic. Quad Area: # Of Units: Constr. Type: Water Heater: : Office Use - Land Use: Zoning Code: Bedrooms: Range: # Of Buildings: Occupancy Group: Heat Source: sq.F To request an inspection call the 24 hour recording at a.m. will be made the same working day, inspections working day. Framing Special Final Building Required lnspeffi{ Building -Prior to cover. -See Plan Review and/or lnspectors Notes, or prior to cover if applicable. -When all required inspections have been approved and the building is complete Job# 02-00509-01 # Of Stories: Height (feet): Current Units: Proposed Units: Gensus Code: Does not apply Total: Page2 of 2 Construction Types: Occupancy Groups: # Of Buildings: # Of Bedrooms: Handicap Access? Area (Sq. Feet) Main:Accessory: Fee Paid On Receipt# Value/Quantity Fee Amount Buildin Building Permit State Surcharge For Building Permit B% Building Administrative Fee Total Building 05102t2002 05t02t2002 05102t2002 8790 8790 8790 4,500 $68.40 $4.79 $5.47 $78.66 Grand Total Plan Check Type Checked By Date Completed Comment Structural-Res Don Moore 0510212002 By signature, I state and agree that I have carefully examined the hereby certify that all information herein is true and correct, and I completed application and do further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon. I further state that only contractors and em ployees who are in compliance with ORS 701.055 will be used on this project. I further agree to ens ure that all required inspections are requested at the proper time, that the project address is readable from the street, that the permit card is located at the front of , and the approved set of plans will remain on the site at all times during $78.66 re s- Z-L oa(e MaJz-oa-oz o?:44P Mor-{er Eng & Bui'lding D (--tl-)48,4-68s9 P.02 MORTIER ENGINEERING, P.C. c?@SO?o t k 1245 PEARL STREET EUGENE. OREGON 9740'I PHONE (541) 484-9080. FAX (541) 484'6859 TOLL FREE iN OREGON 1.877.66I.9959 05t08t02 Northwest Rebuilders 91992 Highway 99, Unit D Junction City, OR 97448 Sincerely, SiRUCTURAL BUILDING DESIGN . FIBE PBOTECTION CODE CONSULTANT . PI-AN CHECKING CONSTBUCNON INSPECTION RE: 4733 Union Terrace - Roof Damage - W.O. #14509 As you requested, an initial structural inspection of the truss damage caused by a tree falling during the wind storm of 02107102 on the single level house at the above address was performed by Mortier Engineering, P.C. on 04129102. A subsequent inspection was made on 05/07/02 when the roofing had been removed to view the damage to the end connections. Approximately 80% of the truss tails have been broken off requiring the tails to be replaced. A mrnrmum of one truss end connection has been severely damaged due to crushing requiring connection and top chord replacement, a minimum of one top chord has been broken requiring replacement, and a minimum of two struts have been released from the top chord connection requiring connection replacement. The bottom chords appearto be in satisfaclory condition, but were not fully open to view due to insulation and ceiling nailers. Contacl the engineer if any damage to the bottom chords is detected by the contractorafrer removal of insulation and during truss repair, to determine extent of damage and any repair that may be needed. Thank you for this opportunity to be of service. lf you have questions regarding this report, please epntact me at 484-9080 ,nO!ED z9 02 2, N ORLI.,t, RY i9 EXPIHATION DAfE:6/30/o 3 {l i,, Pamela S. Hillstrom, P,E. it s. lil 5/t/oz r/2l- s\gneo tt'l'7