Loading...
HomeMy WebLinkAboutPermit Building 2010-06-11sLP e�ur_C�c� rS CITY OF SPRINGFIELD SON r M mm • -iL• . - Building/Combination Permit Status Issued PERMIT NO: COM2010-00630 225 Fifth Street, Springfield, OR ISSUED: 06/11/2010 541-726-3753 Phone APPLIED: 05/18/2010 541-726-3676 Fax EXPIRES: 12/11/2010 541-726-3769 Inspection Line VALUE: $ 230,000.00 SITE ADDRESS: 510 S 48TH ST SPRINGFIETYPE OF WORK: Single Family Residence ASSESSOR'S PARCEL NO.: 1702324406400 TYPE OF USE: New Residential PROJECT DESCRIPTION: Single family residence Owner: HAYDEN ENTERPRISES Phone Number: 541-228-6935 Address: 2622 SW GLACIER PL #110 REDMOND OR 97756 CONTRACTOR INFORMATION Contractor Type Contractor License Expiration Date Phone General HAYDEN ENTERPRISES 92208 07/29/2011 541-228-6935 Electrical TOP NOTCH ELECTRIC INC 172366 09/29/2010 541-317-1998 Mechanical PACIFIC AIR COMFORT INC 39237 03/25/2012 541-672-9510 Plumbing STUTZMAN SERVICES INC 31747 06/12/2012 541-928-8942 BUILD TION 1+�`N to �� # of Units: egos Ott 3qto�` Opt -e 2 Lot Size: 7,126 Primary Occupancy Group: QNit pied ose e 24.00 Sq Ft 1st Floor: 1,280 Secondary Occupancy G ``,,,$ a �h i'� lf�lrW ale tet. Oth`p eoq#�e'ore ,,Forced Air Gas Sq Ft 2nd Floor: 609 Primary Construction T �Ot► .p0��WOR t�o�! Gas Sq Ft Basement: {{g,�ayb''10Secondary Construction Ica Gas SqGarage/Carport 400 # of Bedrooms: �nN(O the CentO`e�pCE r► Sq Ft Other: 365 0�o. e11nkled Building: �`t1�0 g$p ng n/a Occupant Load: C �0 4u Ge DEVELOPMENT INFORMATION REQUIRED PARKING Frontyard Setback: 14.00 Overlay Dist: Total: 2 Side 1 Setback: 7.45 # Street Trees Rqd: 2 Handicapped: Side 2 Setback: 5.00 'PkVe&-Drive Rqd: Yes Compact: Rearyard Setback: 49.90 0/0 of LofCoverage: 32.10 Solar Setbacks: 0.00 9O?, Subdivision Not Accepted PUBLIC IMPROVEMENTS Street Improvements: c�: 4�S Q�� �Q�► Fully ImUroved �,1�� QQN Curbside 7' Storm Sewer Available: Yes �15 Special Instruction: Storm water to tap/ For this parcel in Westin�y{h$h� ��"" ation to the Building Division, by the City Engineer "that no conrieiq a3 ��il�` oossainitary or storm H2O Notes: systems, until the subdivision is accepted by tgny��i' P Page 1 of 5 0'... Building/Combination Permit Status Issued PERMIT NO: COM2010-00630 225 Fifth Street, Springfield, OR ISSUED: 06/11/2010 541-726-3753 Phone APPLIED: 05/18/2010 541-726-3676 Fax EXPIRES: 12/11/2010 541-726-3769 Inspection Line VALUE: $ 230,000.00 Valuation Description Description Tvpe of Construction $ Per Sq Ft Square Footage Value Date Calculated or multiplier or Bid Amount Estimate Estimate $1.00 .230,000.00 $230,000.00 05/18/2010 Total Value of Project $230,000.00 Amount Paid Date Paid Receipt Number Fee Description Plan Review Residential $804.60 5/18/10 2201000000000000522 + 12% State Surcharge $251,14 6/11/10 1201000000000000660 + 5% Technology Fee $122.49 6/11/10 1201000000000000660 1st Appliance $79.00 6/11/10 1201000000000000660 3 Baths One & Two Family $402.00 6/11/10 1201000000000000660 Addressing Assignment $38.00,; .. 6/11/10 1201000000000000660 Building Permit $1,237.85 6/11/10 1201000000000000660 Curbcut Permit $88.00, .. 6/11/10 1201000000000000660 Dryer Vent $9.00" 6/11/10 1201000000000000660 Exhaust Hoods $13.00 6/11/10 1201000000000000660 Fire SF Fee - Residential $132.70 6/11/10 1201000000000000660 Fireplace (Listed) $20.00 6/11/10 1201000000000000660 Gas Outlets 1-4 $7.00 6/11/10 1201000000000000660 Heat Pump $17.00 6/11/10 1201000000000000660 Plan Review Major - Planning $211.00 6/11/10 1201000000000000660 PW Disc - 2nd Permit $-30.00 6/11/10 1201000000000000660 Residence Wiring 1000 Sq Ft $134.00 .,6/11/10 1201000000000000660 Residence Wiring Ea Addd 500 $75.00 6/11/10 1201000000000000660 Sanitary Sewer - Improvement $1,030.40 6/11/10 1201000000000000660 Sanitary Sewer - Reimbursement $1,722.88, 6/11/10 1201000000000000660 SDC MWMC Administration $10.00 6/11/10 1201000000000000660 SDC MWMC Compliance Charge $22.63 6/11/10 1201000000000000660 SDC MWMC Improvement $1,333.57 6/11/10 1201000000000000660 SDC MWMC Reimbursement $101.97 6/11/10 1201000000000000660 SDC Sanitary/Storm Admin $248.04 6/11/10 1201000000000000660 SDC Storm - Improvement $246.33 6/11/10 1201000000000000660 SDC Storm - Reimbursement $885.83 6/11/10 1201000000000000660 SDC Tran Reimburs-Residential $279.54 6/11/10 1201000000000000660 SDC Trans Improvement -Resident $1,140.17 6/11/10 1201000000000000660 SDC Transportation Admin $90.63 6/11/10 1201000000000000660 Sidewalk Permit $88.00 6/11/10 1201000000000000660 Temp Power 200 amps or less $63.00 6/11/10 1201000000000000660 Vent Fan $36.00 6/11/10 1201000000000000660 Willamalane Single Family $2,858.00 6/11/10 1201000000000000660 Total Amount Paid $13,768.77 Pate 2 of 5 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line GFIELD Building/Combination Permit PERMIT NO: COM2010-00630 ISSUED: 06/11/2010 APPLIED: 05/18/2010 EXPIRES: 12/11/2010 VALUE: $ 230,000.00 Plan Reviews Initial Review 05/20/2010 0.5/20/2010 APP DJB Planning Review 05/20/2010 '05/21/2010 APP DDK Front elevations are site specific and contain REQUIRED design elements. Inspectors will field check that actual elevations match submitted designs as shown on the approved set of plans. Public Works Review 05/21/2010 05/25/2010 APP LKW Storm water to tap/ For this parcel in Westwinds, it is the recommendation to the Building Division, by the City Engineer "that no connection shall be made to sainitary or storm H2O systems, until the subdivision is accepted by City Council" Structural Review 05/20/2010 06/07/2010 APP RWC To Request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspect oi�9"requested after 7:00 a.m. will be made the following work day. Erosion/Grading Inspection: Prior to ground disturbance and after erosion measures are.installed. Sidewalk - Curbside: After forms are erected but prior to placement of concrete. Curbcut - Standard: After forms are erected but prior to placement of concrete. Erosion/Grading Inspection: Prior to ground disturbance and after erosion measures are installed. Ufer Electrical Ground: Install ground rod at footing and call for inspection in conjunction with footing and/or foundation inspection. Footing: After trenches are excavated. Foundation: After forms are erected but prior to concrete placement. Post and Beam: Prior to floor insulation or decking. Floor Insulation: Prior to decking. Shear Wall Nailing: Before covering sheathing with finish materials. Framing Inspection: Prior to cover and after--atl rough in inspections have been approved. Wall Insulation: Prior to cover. } Paee 3 of 5 "FadiMAL 0 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Ceiling Insulation: Prior to cover. Drywall: Prior to taping. CITY Building/Combination Permit PERMIT NO: COM2010-00630 ISSUED: 06/11/2010 APPLIED: 05/18/2010 EXPIRES: 12/11/2010 VALUE: $ 230,000.00 Lath/Plaster: To be made after all lathing and gypsum board, interior and exterior are in place, but prior to plastering. Hold Downs Installed: Special Inspection performed prior to placement of concrete. Provide report to City Building Inspector. Final Building: After all required inspections,have been requested and approved and the building is complete. Perimeter Foundation Drains: After gravel and filterrcloth is installed but prior to backfill. Underfloor Plumbing: Prior to insulation or decking. Underfloor Drain: Prior to cover or placement of concrete. Rough Plumbing: Prior to cover and including required testing. Shower Pan. Prior to covering and including required testing. Water Line: Prior to filling trench and including required testing. Sanitary Sewer Line: Prior to filling trench and including required testing. Storm Sewer Line: Prior to filling trench. Final Plumbing: When all plumbing work is complete. Underfloor Mechanical. Prior to insulation or decking and including required testing. Underfloor Gas: After line is installed and required testing and capped if not attached to an appliance. Rough Gas: After line is installed and required testing and capped if not attached to an appliance. Gas Service: After line is installed and line has been connected to a minimum of one appliance including required testing. Presure test done at this point. Rough Mechanical: Prior to Cover Final Gas: When all gas work is complete. Final Mechanical: When all mechanical work. is complete. Temporary Electric: Approval required prior to Utility Company energizing pole. Ufor Electrical Ground: Install ground rod at footing and call for inspection in conjuction with footing and/or foundation inspection. Rough Electric: Prior to Cover Final Electric: When all electrical work is complete. Low Voltage: Prior to cover. Page 4 of 5 CITY OF SPRINGFIELD Building/Combination Permit Status Issued PERMIT NO: COM2010-00630 225 Fifth Street, Springfield, OR ISSUED: 06/11/2010 541-726-3753 Phone APPLIED: 05/18/2010 541-726-3676 Fax EXPIRES: 12/11/2010 541-726-3769 Inspection Line VALUE: $ 230,000.00 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property', and the approved set of plans will remain on the site at all times during construction. Owner or Contractors Signature Page 5 of 5 Date Electrical Permit A tion 225 Fifth Street* Springfield, OR 97477+PH(541)726-3753+FA.X(541)726-3689 - DEPARTMENT USE .ONLY SPRINGFIELD xWR� z 630 '=„ s Permit no.: Date: S P This permit is issued under OAR 918-309-0000. Permits are nontransferable. Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days. —LOCA—L GOVERNMENT -APPROVAL Zoning approval verified? ❑ Yes ❑ No CATEGORY OF CONSTRUCTION— ONSTRUCTION[;Residential [a Residential 1] Government ❑ Commercial -JOB-SITE INFORMATION"AND LOCATION'... Job site address: me) ?+hS,-)- City: ,•, C� State: (3 ZIP: 97'178' Subdivision. W r i kvw(c Lot no.: _ btSCRIPTION OF .WORK le $ �;;,:-'PROPERTY OWNER Name: 4-2:4,f v-\. c,, ,•e S. Address: Y �e-, sc.,/ City: 14 State: Q 2 ZIP: 77 to Phone: WL rpjhon Ut►lit E-mail: A'REN adopted b rules are se This installation is be fsf>t' r �,ru�es owned by me or a m IQ e� a� e hp property is not intended 479.540(1) and 479.5 . inc-1 �he center. on utility Notl +cat Signature: oallc for the Oregon 44). p()-332-23 PONT RAC R` 1 L TION':_ Business name: T Ab I PC Address: Q(z %Gl coves C, City: State: C92 ZIP: Phone: N I =31? -1G9-,-� Fax: - - E-mail: CCB license no.:J /'--� 3�p% BCD license no.: �Z Signing supervisor's license no.: V` Print name of signing supervisor: $ Signature of signing supervisor: u PE SNALL J"Is PERM pl9Ta aRIZED UNDER BANDai�- (U- � ,-AW1t114CED aR 1S A /nu 0�� /*r 180 DAY PER1aD. 440-2584-J (9/08/CONI) V�o FEE SCHEDULE ' Cot Lf lI Total Number of inspections per item (} Qlv. 1 is. cost. Residential, per unit, service included: 1,000 sq. ft. or less (4) ) $134.00 ON Each thereof additional 500 sq. ft. or portion 3 $ 25.00 $ 75' Limited energy (2) $ 32.00 $ Each manufactured home or modular dwelling service or feeder (2) $ 63.00 $ Services or feeders: installation, alteration, relocation 200 amps or less (2) $ 81.00 $ 201 to 400 amps (2) $ 93.00 $ 401 to 600 amps (2) $158.00 $ 601 to 1,000 amps (2) $205.00 $ Over 1,000 amps or volts (2) $469.00 $ Reconnect only (2) $ 63.00 $ Temporary services or feeders: installation, alteration, relocation 200 amps or less (2) $ 63.00 $ 201 to 400 amps (2) $ 87.00 $ 401 to 600 amps (2) $126.00 $ Over 600 amps or 1,000 volts, see services or feeders section above Branch circuits: new, alteration, extension per panel a. Fee for branch circuits with purchase of a service or feeder fee: Each branch circuit $ 6.00 $ b. Fee for branch circuits without purchase of a service or feeder fee: First branch circuit (2) $ 55.00 $ Each additional branch circuit $ 6.00 $ Miscellaneous fees: service or feeder not included Each pump or irrigation circle (2) $ 63.00 $ Each sign or outline lighting (2) $ 63.00 $ Signal circuit or a limited -energy panel, alteration, or extension (2) $ 63.00 $ Each additional inspection: (1) $58.00 $ �. 4 .. _ 'APPLICANT USE......,�rf-- nter subtotal of above fees FOfiiimum Permit Fee $58.00) $ Z-7Z-, IV.tnter 12% surcharge (.12 x [A]) $ (C) Technology Fee (5% of [A]) $ TOTAL fees and surcharges (A through C): $ SFV r willamalan Park and, Recreation District Job. No. •C�d � �� SYSTEM DEVELOPMENT CHARGE WORKSHEET January 1 dune 30, 2010 NAME: 14gj>Cw WD mem PHONE: Sy/ ;;-?F'-6 `7r5 ADDRESS:�CITY eO► STATEJ4 ZIP: ,73"G LOCATION OF PROPOSED BUILDING SITE: Street Address: Plat Name: Tax Lot Number: 1. DEVELOPMENT TYPE (Check appropriate dwelling(s). Dwelling type definitions are on the back.) A. Singie-Family Single—FamilyDetached NO. OF UNITS B. Single-Famil Attached NO. OF UNITS C. Multi=Famii— Apaalftrn6 �t NO. OF UNITS D. Sin le Room Occu anc N.0-017--U-NITS - - ---- E. Accesso Dwellin Unit NO. OF UNITS WILLAMALANE SDC X $2,858 per unit = X $3,100 per unit = X $2,641 per unit = -X $1,321 -per-unit X $1550 per unit = $ 2. SDC CREDIT (If applicable) SDC payer must furnish proof of Willamalane Credit approval.} $ 3. TOTAL WILLAMALANE NET SDC ASSESSED (if SDC reduced for Credit) Development Services Department Date City of Springfield 5 t 225 Fifth Street City of Springfield Official Receipt Springfield, Oregon 97477 V '-.lopment Services Department 541=726=3159 Phone Public Works Department RECEIPT #: 1201000000000000660 Date: 06/11/2010 9:02:38AM Job/Journal Number Description Amount Due COM2010-00630 Plan Review Major - Planning 211.00 COM2010-00630 Sidewalk Permit 88.00 COM2010-00630 Curbcut Permit 88.00 COM2010-00630 PW Disc - 2nd Permit (30.00) COM2010-00630 SDC Storm - Improvement 246.33 COM2010-00630 SDC Storm - Reimbursement 885.83 COM2010-00630 Sanitary Sewer - Reimbursement 1,722.88 COM2010-00630 Sanitary Sewer - Improvement 1,030.40 COM2010-00630 SDC Tran Reimburs-Residential 279.54 COM2010-00630 SDC Trans Improvement -Resident 1,140.17 COM2010-00630 SDC MWMC Reimbursement 101.97 COM2010-00630 SDC MWMC Improvement 1,333.57 COM2010-00630 SDC MWMC Administration 10.00 COM2010-00630 SDC Sanitary/Storm Admin 248.04 COM2010-00630 SDC MWMC Compliance Charge 22.63 COM2010-00630 SDC Transportation Admin 90.63 COM2010-00630 Building Permit 1,237.85 COM2010-00630 3 Baths One & Two Family 402.00 COM2010-00630 Vent Fan 36.00 COM2010-00630 Exhaust Hoods 13.00 COM2010-00630 Dryer Vent 9.00 COM2010-00630 Gas Outlets 1-4 7.00 COM2010-00630 Residence Wiring 1000 Sq Ft 134.00 COM2010-00630 Temp Power 200 amps or less 63.00 COM2010-00630 Addressing Assignment 38.00 COM2010-00630 Willamalane Single Family 2,858.00 COM2010-00630 1st Appliance 79.00 COM2010-00630 Fireplace (Listed) 20.00 COM2010-00630 Heat Pump 17.00 COM2010-00630 Residence Wiring Ea Addtl 500 75.00 COM2010-00630 Fire SF Fee - Residential 132.70 COM2010-00630 + 12% State Surcharge 251.14 COM2010-00630 + 5% Technology Fee 122.49 Item Total: $12,964.17 Payments: Check Number Authorization Type of Payment Paid By Received By Batch Number Number How Received Amount Paid Check HAYDEN HOMES LLC djb 25635 In Person $12,964.17 Payment Total: $12,964.17 cReceintl Page 1 of 1 6/11/2010 225 Fifth Street sp"MINGWOM 0 City_ of Springfield Official Receipt Springfield, Oregon 97477 1 L?` '-Ilopment Services Department 541-726-3759 Phone Public Works Department RECEIPT #: 2201000000000000522 Date: 05/18/2010 9.13:37AM Job/Journal Number Description Amount Due COM2010-00630 Plan Review Residential 804.60 Item Total: $804.60 Payments: Check Number Authorization Type of Payment Paid By Received By Batch Number Number How Received Amount Paid CreditCard HAYDEN ENT dib 020597 In Person $804.60 Payment Total: $804.60 cReceintl Page 1 of 1 5/18/2010 DEVELOPMENT SERVICES DEPARTMENT k Li7A'Y1 O 225 FIFTH STREET SPRINGFIELD, OR 97477 PHONE (541)726-3753 FAX (541) 726-3689 www. d s pringiiel d. or. us MOISTURE -CONTENT ACKNOWLEDGEMENT FORM L cv-A builde at the following address: Street Address City C -(O- (; Permit # If applicable: Co + ( - wcsk w feat's Subdivision/Lot . am the general contractor or the owner - Map and Tax Lot To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2, I am notifying the building official that I am aware of the moisture content requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference.] Section 8318.2 Moisture content. Prior to issuance of the insulation/vapor barrier approval required by R109.1.5.2 of this code: (A) All moisture -sensitive wood framing members used in construction shall have a moisture .content of not more than 19 percent of the weight of dry wood framing members. (B) The general contractor or the owner who was issued the structural permit shall notify the building official on a division approved form that the contractor or the owner who was issued the structural permit is aware of and has taken steps to meet the requirement in paragraph (A). Signature IA.Moisture Content Aclmow Form.doc 7—,2a— �D. Date .T LANE COUNTY OREGON [HE SUILDING D�f'ARTMENT -._------------------�----...----,- ._LLC Exterior Wail Envelope Self-Certificatior, Form 1, Nyden o,, - owner -builder at the following address: sro - -�) tjs� v` T , Street Address City C -6o- 06 Permit# am the general contractor or the To conform to the 2008 Oregon Residential Specialty Code (ORSC), Section R703.1.1, I am notifying the building official that I am aware of the exterior wall envelope requirements of R703.1.1, and hereby certify that the components of the exterior wall envelope have been installed in accordance with the code requirements. [Section R703.1.1 is provided for reference on the reverse side of this form.] Signature 7—.X —/U. Date Revised: 2/8/2010 Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering: R703.1.1 Exterior Wall Envelope. To promote building durability, the exterior wall envelope shall be installed in a manner that water that enters the assembly can drain to the exterior. The envelope shall consist of an exterior veneer, a water -resistive barrier as required in R703.2, a minimum 1/8 inch space between the water -resistive barrier and the exterior veneer, and integrated flashings as required in R703.8. The required space shall be formed by the use of any non -corrodible furring strip, drainage mat or drainage board. The envelope shall provide proper integration of flashings with the water -resistive barrier, the space provided and the exterior veneer. These components, in conjunction, shall provide a means of draining water that enters the assembly to the exterior. Exceptions: 1. A space is not required where the exterior veneer is installed over a water -resistive barrier complying with section R703.2 which is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirement of ASTM E2273 or other recognized national standards. 2. A space is not required where window sills are equipped with pan flashings which drain to the exterior surface of the veneer in a through wall fashion. All pan flashings shall be detailed within the construction documents and shall be of either a self -adhering membrane complying with AAMA 711-07 or of an approved corrosion -resistant material or a combination thereof. Self -adhering membranes extending to the exterior surface of the veneer shall be concealed with trims or other measures to protect from sunlight. 3. A space is not required where the exterior veneer is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other recognized national standards and is installed over a water resistive barrier complying with section R703.2. 4. A space is not required where the exterior veneer is matching an existing exterior finish as in additions, alterations, or repairs. 5. A water-resistant exterior wall envelope shall not be required over concrete or masonry walls designed in accordance with Chapter 6 and flashed according to section R703.7 or R703.8. 6. Compliance with the requirements for a means of drainage, and the requirements of Section R703.2 and Section R703.8, shall not be required for an exterior wall envelope that has been demonstrated to resist wind -driven rain through testing of the exterior wall envelope, including joints, penetrations and intersections with dissimilar materials, in accordance with ASTM E 331 under the following conditions: 6.1. Exterior wall envelope test assemblies shall include at least one opening, one control joint, one wall/eave interface and one wall sill. All tested openings and penetrations shall be representative of the intended end-use configuration. 6.2. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size. 6.3. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24 pounds per square foot. 6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure duration of 2 hours. The exterior wall envelope design shall be considered to resist wind -driven rain where the results of the testing indicate that water did not penetrate: control joints in the exterior wall envelope; joints at the perimeter of openings penetration; or intersections of terminations with dissimilar materials. DEVELOPMENT SEP•.\ACES DEPARTI LAMENT SPRINGFIELD e int �a = p zi5t: 2 X i7s 'ry _ 225 FIFTH STREET SPRINGFIELD, OR 97477 PHONE (541)726-3753 FAX (541)726-3689 wtlnv.6.springfield. or. us HIGH -EFFICIENCY LIGHTING SYSTEMS OREGON RESIDENTIAL SPECIALTY CODE (ORSC) Permit No.: , e�' 3e)- Site Address: 0 5 ' x"/16 ,57z Subdivision/Lot: t,�p5� w,"n G'/ and/or . Map and Tax Lot: Jurisdiction By my signature below, I certify that a minimum of ❑ fifty (50) percent, seventy-five (75) percent, of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)1 * Check the 75% box if the additional measure selected to comply with ORSC NI 101.1 and Table N1 101.1(2) requires 75% of lighting fixtures to have energy efficient lamps. Signed: Print Name: �`„1 r/Ciellel-flI ContrnctOr/Authorized Agent Date: S—'' .3/— /O' Contractor's CCB # ZO Expiration Date: �`31--- I ORSC Section N 1107.2. High -Efficiency Lighting Systems. A minimum of fifty (50) percent of the permanently installed lighting fixtures, seventy-five (75%) percent, if the selected additional energy code measures in the Table N1101.1(2) requires greater liollting efficiency, shall be installed with compact or linear fluorescent, or a h. -]hint °ource. that has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this re.quir,,;ment. The he Building official shall he notified in .writing at the final inspection that. a minimum of the required percentage of the .._ I:._...._. FL.......,- ...:. ..._,." r..r+: r•,n„ r,4 11 (1 n:>r ; -,-0 -,It DEVELOPMENT SERVICES DEPARTNIENT scr, SPRINGFi, J Irl 225 FIFTH STREET SPRINGFIELD, OR 97477 PHONE (541)7263753 FAX (541)726-3889 www. d. springBeld. or. us MOISTURE -CONTENT ACKNOWLEDGEMENT FORM am the general contractor or the owner - builder at the following address: i Street Address Ci C-10 - (57 Permit # If applicable: Subdivision/Lot Map and Tax Lot To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2, I am notifying the building official that I am aware of the moisture content requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference.] Section 8318.2 Moisture content. Prior to issuance of the insulation/vapor barrier approval required by R109.1.5.2 of this code: (A) All moisture -sensitive wood framing members used in construction shall have a moisture .content of not more than 19 percent of the weight of dry wood framing members. (B) The general contractor or the owner who was issued the structural permit shall notify the building official on a division approved form that the contractor or the owner who was issued the structural permit is aware of and has taken steps to meet the requirement in paragraph (A). tare JAMoisture Content Aclmow Form.doc Date SPRINGFIELD SCAFiiL, !' UILDING C EPARTMENT _LLLANEC Exterior Wall Envelope Self -Certification Form I,_ owner -builder at thy" ollowing address: r/O ' -5 �I Street Address :e City sc� _ Permit# am the general contractor or the To conform to the 2008 Oregon Residential Specialty Code (ORSC), Section R703.1.1, I am notifying the building official that I am aware of the exterior wall envelope requirements of R703.1.1, and hereby certify that the components of the exterior wall envelope have been installed in accordance with the code requirements. [Section R703.1.1 is provided for reference on the reverse side of this form.] Signature � �.:�/ Lam• _ _ Date Revised: 2/8/2010 Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering: R703.1.1 Exterior Wall Envelope. To promote building durability, the exterior wall envelope shall be installed in a manner that water that enters the assembly can drain to the exterior. The envelope shall consist of an exterior veneer, a water -resistive barrier as required in R703.2, a minimum 1/8 inch space between the water -resistive barrier and the exterior veneer, and integrated flashings as required in R703.8. The required space shall be formed by the use of any non -corrodible furring strip, drainage mat or drainage board. The envelope shall provide proper integration of flashings with the water -resistive barrier, the space provided and the exterior veneer. These components, in conjunction, shall provide a means of draining water that enters the assembly to the exterior. Exceptions: 1. A space is not required where the exterior veneer is installed over a water -resistive barrier complying with section R703.2 which is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirement of ASTM E2273 or other recognized national standards. 2. A space is not required where window sills are equipped with pan flashings which drain to the exterior surface of the veneer in a through wall fashion: All pan flashings shall be detailed within the construction documents and shall be of either a self -adhering membrane complying with AAMA 711-07 or of an approved corrosion -resistant material or a combination thereof. Self -adhering membranes extending to the exterior surface of the veneer shall be concealed with trims or other measures to protect from sunlight. 3. A space is not required where the exterior veneer is manufactured in a manner to enhance drainage and meets the 759 drainage efficiency requirements of ASTM E2273 or other recognized national standards and is installed over a water resistive barrier complying with section R703.2. 4. A space is not required where the exterior veneer is matching an existing exterior finish as in additions, alterations, or repairs. S. A water-resistant exterior wall envelope shall not be required over concrete or masonry walls designed in accordance with Chapter 6 and flashed according to section R703.7 or R703.8. 6. Compliance with the requirements for a means of drainage, and the requirements of Section R703.2 and Section R703.8, shall not be required for an exterior wall envelope that has been demonstrated to resist wind -driven rain through testing of the exterior wall envelope, including joints, penetrations and intersections with dissimilar materials, in accordance with ASTM E 331 under the following conditions: 6.1. Exterior wall envelope test assemblies shall include at least one opening, one control joint, one wall/eave interface and one wall sill. All tested openings and penetrations shall be representative of the intended end-use configuration. 6.2. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size. 6.3. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24 pounds per square foot. 6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure duration of 2 hours. The exterior wall envelope design shall be considered to resist wind -driven rain where the results of the testing indicate that water did not penetrate: control joints in the exterior wall envelope; joints at the perimeter of openings penetration; or intersections of terminations with dissimilar materials.