HomeMy WebLinkAboutPermit Building 2017-03-15L63T dF pRAIUINC�S:
FIG,
1
51TE FLAN 4
5ITE INFOfRi�irATION
FG,
2
FROF05 D
ELEVATION5
Fes.
3
FIROFO5 D
FLOOR FLAN
FG.
4
FOUNDATION
/ FLOOfR FFRA1 IING FLAN 4 DETAILS
FG.
5
ROOF Fi X—IING PLAT l $ TfRU&e D iAIL&
f=,G,
&
6ECT ION5 $
5HEAR ALL DET AIL6
GENERAL CONSTRUCTION NOTES:
FRAMING-
EXTERIOR
RAMINCA:EXTERIOR WALLS - 2 X 6s 6 16" D.C. W/ 1116" OSB EXT, 4 1/2" GYP. INT.
TYPICAL EXTERIOR SHEATHING NAILING - Id NAILS a 6" O.C. EDGES 4 12" O.C. FIELD
INTERIOR WALLS - 2 X 4s a 16" O.C. W/ 1/2" GYP. BOTH SIDES
WINDOW HEADER. HEIGHTS:
MAIN FLOOR - 6'-9" APP. UNLESS NOTED
ALL DIMENSIONAL LUMBER TO BE DOUG FIR *2 OR SETTER
ALL WOOD IN DIRECT CONTACT WITH CONCRETE TO BE PRESSURE TREATED (P.T.)
EXTERIOR HEADERS TO BE 4 X 0 (UNLESS NOTED)
INTERIOR HEADERS TO BE:
SPANS UP TO 3'-0" - USE (2) 2 X 4'S
3'-0" TO 6'-O" - USE 4 X 6
6'-0" 4 UP - USE 4 X 8
UNLESS OTHERWISE NOTED
FLOORS:
TJ I's AS NOTED W/ 3/4" T 4G PLYWOOD
NAIL 4 GLUE SUBFLOOR TO JOISTS W/ 106 NAILS -9 6" O.G. 6 EDGES 4 12" O.G. FIELD
USE APPROVED SUBFLOOR GLUE TO ALL JOISTS 4 SPLOOGE LOTS OF GLUE
INTO ANY JOIST HANGERS PRIOR TO INSTALLING J015TS (stops squeaks, you knowl)
M€CROLAM BEAMS: (WHERE APPLICABLE)
MULTIPLE 13/4" MICROLAMS MAY BE SUBSTITUTED FOR THICKER BEAMS
FASTEN MULTIPLES TOGETHER AS FOLLOWS:
2 LAMINATIONS - 2 ROWS OF 1/41IX3 1/2" SIMP SDS SCREWS -9 12" O.G. ON ONE SIDE, 2" FROM TOP 4 BOTTOM
3 LAMINATIONS - 2 ROWS OF 1/4"X3 1/2" SIMP SDS SCREWS 6 12" O.C. ON BOTH SIDES, 2" FROM TOP 4 BOTTOM
4 LAMINATIONS - 2 ROWS OF 1/2"XS" THROUGH BOLTS -S 12" O.C. 2" FROM TOP 4 BOTTOM
ROOF:
P.E. TRUSSES OR RAFTERS AS SPECIFIED W/ 1/2" 5 -PLY PLYWOOD OR 1116" OSB
TRUSS HOLDOWNS:
PROVIDE SIMPSON H2B CLIPS a ALL TRUSSES TO TOP PLATE
PROVIDE SIMPSON SDWC €5600 SCREWS 6 ALL TRUSSES TO
EXPOSED BEAMS BELOW - UNLESS NOTED OTHERWISE
USE PLYWOOD INSUL. BAFFLES OR EQUAL PROVIDE 1" AIR SPACE BELOW ROOF SHEATHING
HOUSE WRAP,4 EXTERIOR DRAINAGE
PROVIDE TYVECK DRAINWRAP SYSTEM (the crinkly stuff) ,w ALL EXTERIOR WALLS.
TAPE ALL LAPPED SEAMS AS WELL AS DOOR 4 WINDOW OPENINGS WITH TYVECK FLASHING TAPE
OVER ALL WINDOW 4 DOOR FLANGES
�E? SCRIPTIVE PATH 1 INSULATION REQUIREMENTS
EXTERIOR WALLS
ABOVE GRADE - R- 21
UNDER FLOORS - R- 30
FLAT CEILINGS - R- 3&
VAULTED CEILINGS - R- 30 (not to exceed 5050
of the total heated space floor area)
DUCTS - R- S
PLUS, PROVIDE A HIGH EFFICIENCY HVAC SYSTEM
NOTE: ALL PENETRATIONS IN THE BUILDING ENVELOPE ARE TO
BE SEALED, WINDOWS AND DOORS ARE CAULKED, TAPED
OR WEATHERSTRIPPED.
ALL HALF BATH FANS TO BE 50 CFM MIN.
ALL FULL BATHROOM FANS TO BE W CFM MIN.
POINT ALL FART FANS TOWARD THE OZONE LAYER!
PROVIDE SMOKE DETECTORS PER R-314
PROVIDE CARBON MONOXIDE DETECTORS PER R-315
45.15'
N89°46'7E
5' setback
w
0
(P M
r-
di�
46.11'
N 82
33'.3011 W
y STREET
SITE PLAN
SCrALE:: 1�8 aE = 1'
FLAT LOT
TIE: 5TOR1" I DRAIN& TO WEEP HOLES IN CURS
REVIEWEDP��pNCE
SITE I NFORMAT I ON
W
0
rm
'
OWNER: MARK 4 LINDA 6EBRING
FROf=ERT*r ADDRE55; H 5t, ('710 If ST
5PRINGFIELD , OR. 'B'14"11
i" IAF #: 11 03 3& 21
TAX LOT #: 20(o00
5QUARE FOOTAGE
0
Z
MAIN FLOOR 1378
5' setback
—18' Front yard setback
CONTfRACTOfR TO V fRIF`1' ,ALL D I1 IEN510N5 FfRIOF` TO OfRD fRINC; 4 CONSTfRUCTION
TOTAL LIVING 1310:#
GAR AGE /SNOW 310*
NOTICE:
THIS PERMIT SHALL EXPIRE IF THE WORK
AUTHORIZED UNDER THIS PERMIT IS NOT
COMMENCED OR IS ABANDONED FOR
ANY 180 DAY PERIOD.
ATTENTION: Oregon law requires you to
follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth
in OAR 952-001-0010 through OAR 952-001-
0090. You may obtain copies of the rules by
calling the center. (Note: the telephone
number for the Oregon Utility Notification
Center is 1-800-332-2344).