Loading...
HomeMy WebLinkAboutPermit Building 1997-04-29SPFINGFIELD o RESIDENIIAI, PERMIT APPI.ICATION CITY OF SPRINGFIEI.D COMMI'NITY SERVICES DIVISTON BUILDING SAFETY a office: Inspection Line: Page 1 .Tob Nnnber: 97 0325 726 -37 59 725 -37 59 225 Nortsh Fifth Street Springfield, OR 97477 Locatsion of Proposed Work: 810 S 44TH PL Assessors tutap #: 18020521 LoE: 89 Block: Tax Lot #: Subdivision: 03300 LUCERN MEADOWS SPruNGFTELD, Owner: PROF MGMI(I INC Address: PO BOX 938 Describe Work: S.F. RESIDENCE Phone #: 503-625-0628 city/staLe/zip: sHERWooD, oREGoN 97].40 NEW General: Plumbing: Mechanical: EIecErical: ConEracEor PROFESSIONAL MA 0029281, PO Box 938 Sherwood OR 971400938 CUSTOM PLUMBING 0081994 3248 Kentwood Dr Eugene OR 97401-000 HARVEY & SON 0055682 4680 Main St SpringfieLd OR 9747860 cRov{ VALLEY 00959L0 PO Box 22201, Eugene OR 974020000 Const. Contractor #Expires 03/Ls/eB os/05/e7 02 /26 / ee 01,/06/e8 Phone 235 -1,37 0 352-5233 746-7677 729-5L08 QUAD AREA: 3RSC # OF UNrTS: 1 CONSTR. TYPE: VN WATER HEATER: G SQ FOOTAGE: 1858 -- oFFrcE usE -- LAND USE: 1111 ZONING CODE: LDR # OF BDRMS: 3 RANGE: E # OF BLDGS: 1 OCCY GROUP: R3 HEAT SOURCE: FG INSUL PATH: Pl To requeat an inspection, call the 24 hour recording aE 726-3759 AI1 inspections requested before 7:00 a.m. wiLL be made Ehe same working day, inspections requested afEer 7:00 a.m. will be made Ehe following work day. -.- REQUIRED INSPECTIONS --- FOOTING - After trenches are excavated. FOITNDATfON - After forms are erected but prior to concrete placement. ITNDERFLOOR PITITMBING - Prior to insulation or decking. ITIIDERFLOOR DIECIIAI.IICAL - Prior to insulation or decking. POST AIID BEADI - Prior to ffoor insulation or decking. TNSULATION - Floor; prior to decking wal1/Ceiling; Prior Lo cover WATER LINE - Prior to filling trench. SAI{ITARY SEWER LINE - Prior to filling trench. STORM SEWER LINE - Prior to filling trench. ROUGH ELECTRICAL - Prior to cover. EIJECTRICAIJ SERVICE - Must be approved to obtain permanent power. ROUGH IIECIIAI{fCAL - Prior to cover. ROUGH cAS - after line is installed and capped if not, aLtached to an appli-ance cAS SERVICE - After line is instal-Ied and line has been connected to a minimum of one appliance. Pressure test done at this point. ROUGH PLITIIBING - Prior to cover. FRADTING - Prior to cover. INSITLATION - Floor,. prior to decking Wa1l/Ceiling; Prior Eo cover DRYWALL - Prior to taping. CITRBCII:r - Af t,er f orms are erected but prior to placement of concrete. SfDEWALK - After excavation is complete, forms and sub-base materiaL in place. SPFINGFIELD afr, ilob Number : 97 0325 a Page 2 FINAL PIJITIIBING - When all plumbing work is complete. FINAL MECIIAT{ICAL - When all mechanical work is complete. FINAL ELECTRfCAL - When all- electrical work is complete. PRE BACKFILT: To verify site is clean of debris prior to final grading and backfill. FINAL BUILDING - When all reguired inspections have been approved and the building is complete. Lot Faces: E Solar Approved: Y House Garage Total Height: 23 Lot, Type: IIfrIERIOR Setbacks SIIIE 64020 1_8 Setbk From NPL: 14 N 10 10 Item Main Garage ToLal Value Building Permit Fee Surcharge/Admin --- BUIIJDING PERMIT --- Square Feet x L422 436.75 $/Square Feet 64 .55 L6.27 VaIue 9L,947.OO 7, 105 . 00 99, 053 . 00 433.00 34 .54 TOTAL FEE (A)467.54 --- SYSTE}TS DEVELOP}TENT CIIARGE (SDC) (B) 2,425.05 Systems Development Charge is due on all undeveloped properEies within the City limits and the Citys Urban Growth Boundry which are being improved. --- PIJI'MBING PERIIIT --- Item ResidenEial Bath(s) Plumbing Permit Surcharge/admin TOTAL CIIARGE 3 Fee 1,92 .50 L92 .50 15.41 207.9L(c) --- MECIIAI{ICAL PERMIT .-- Furnace Exhaust Hood Vent Fan Dryer Vent GAS PIPING Mechanical Permit fssuance Surcharge/aamin TOTAL PERMIT 3 5.00 4.50 9.00 3.00 2.OO (D) 24 .50 10.00 L .97 35.47 --- MISCELTAI{EOUS PERMITS Surcharge/aamin Sidewalk Curb Cut WILLAMALANE SDC ELECTRICAL PERMIT 0.00 19.90 14.50 1, 000 . oo L24.20 TOTAL MISCELLAI'IEOUS PERMITS (E)1,158.50 SPFIi.GFIELO Job Nnmber: 970325 a SPilNGFTEI.D,a Page 3 (Excluding Electrical ) unless otherwise notsed --- TOTAI. A}IOI'NT DUE ---(A, B, C, D, and E conbined)4 ,295 .57 --- BUITDING VAI.UE, PLAIiI CHECK AT.ID BUILDING PERI{IT --- This permit is granted on the express condition Ehat t,he said const,ruction sha11, in all respects, conform to the Ordinance adopted by Ehe City of Springfield, including the Development Code, regulating the construction and use of buildings, and may be suspended or revoked at any time upon violation of any provisions of said ordinances. Plan Check Fee: 28L.45 Dat,e paid: Received By: LORNE PLEGER Plans Reviewed By: DON MOORE Date: Building Sit,e Reviewed By: LISA HOPPER 03/04/e7 04/04/e7 Receipt Number: 27452 - -. ADDITTONAIJ COMMEMTS - - - NORTH PROPERTY LINE SETBACK AT MINTMUM TO MEET THE SOLAR REQUIREMENTS DRIVEWAY REQUTRED TO BE PAVED 1 STREET TREES REQUTRED By aj.gnature, I atate and agree, that I have carefutly examined the completed application and do hereby certify that, all information hereon is true and correct,, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining uo the work described herein, and Ehat NO OCCUPAMY wi]l- be made of any sLrucEure without permission of Ehe Community Services Division, Building Safety. I further certify that only contractors and empl-oyees who are in compliance with ORs 701.055 will be used on Ehis project. f further agree to ensure that alf required inspections are requested at t,he proper time, that each address is readable from the street, that the permit card is locatsed at the front of the property, and the a seE of plans will in on t,he site at all times during const,ruction. 7n 4 f ,7 s ture -.- VALIDATION --- Receipt Number: Date Paid: Amount Received: Received By: %q:7 'va_ SPRINGFIELO ,% L 225 FIFTB STREET SPRINGFIELD, OREGON 97417 INSPECTI0N REQIEST. 726-3769 1032{ COHPI^ETE FEE SCffiDI'LE BELOV Nev Residential-Single or Multi-FamilY Per dvelling unit' Service Included: I tems Cos t c-PLICATION naturo OFFICE: 726-3759 1.ON LEGAL JOB DESCRTPTION Permits are non-transferable and expire if vork is not started vithin 180 days of issuance or if vork is suspended for 180 days. 2. CONTRACTOR INSTALI"A'TTON ONLY Electrical Contractor E> Hnu-K Address c) c,C.fe< Ci ty S P+D Phone 1to '7 Zt, -1bv -10L+o Supervisor License Number 3s 71 -S Expiration Date c-t-"y Constr Contr. UurUet I I t 2 8 9 Expiration Date 9- t-91 s 40.00 Services or Feeders Installation, Alterations or Relocation: 200 amps or less 201 amps to 400 amPs - 401 amps to.600 amPs - 601 amps to 1000 amPs- Over 1000 amPs/volts - Reconnect 0n1Y Temporary Services or Feeders Insia1lalion, Alteration or Relocation 200 amps"or less S 40'00 over 4b1 to 6oo amps - $ Bo.oo Over 600 amps or 1OOO vofTs see rrB* above Branch Circuits Nev, Alteration or Extension Per Panel One Circui t Each Addi tional Circuit or vith Service or Feeder Permit s 3s.00 s 2.00 1000 sq.ft. or less Each additional 500 sq. ft or Portion thereof Each Manuf'd Home- or Hodular DveIIing Sertice or Feeder SUBTOTAL OF ABOVE 5Z State Surcharge 32 Admini-strative Fee 3 A t Sum s 8s.00 8L L 30_ B $ 1s.00 not included) 40.00 40.00 20.00 00 00 00 00 00 00 50 60 r.00 130 300 40 s s s s s s t Signature I 0vners Name Address Ci ty of Supe rvising Electrician 7 Phone D( B C OVNER INSTALIATION The installation is being made on property I ovn vhich is not intended for sale, lease or rent' Ovners Signature: DATE: E Miscellaneous (Service/feeder -Each installation Pump or irrigation S Sign/outline Lighting- !Llill ted Energy/Res - $ D 7 5 tlrm t2c/.a O ELECTRICAL PERHIT ty Job Number SPFIi.GF!ELD o CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CEARGE (RESIDEMTIAI.) Page 1 SPilNGFIEI.O, Name or Company: PROF MGMNT INC Location: 8l-0 S 44TH PL Developement T)pe: R Building Size Job No.: 970325 Lot Size:Sq Ft 1. STORM DR,AINAGE Impervious Sq Ft 2. SNiIITARY SEWER - CITY Number Of PFUs (see Page 2) 3. TRAI.ISPORTATION Number Of Units 1X X O.2L5 Per Sq Ft = X 44.75 Per PFU = Cost Per Trip 45L.26 1967 23 Trip Rate 1.01_0 x ;4ss -77 $424.87 $L, O29 -2s ;45s.77 $48s.87 $86.1e $399.58 s2,309 .57 $r-r.s.48 TransportaEion Total 4. SAI.IITARY SEWER - M$MC Number Of PFUs 23 5. ADMINISTR.ATIVE FEES Base Charge (Subtotal above) x x Per PFU + 20.59O + MWMC Admin Fee r-0.00 MITMC CREDIT If Applicable (see Page 2) TOTAL - MWMC SDC SITBTOTAL - (Add Items L, 2, 3 & 4) x 0.50 TOTAL SDC Reviewed By: DENNIS ERNST Date: 03/05/97 $2,425 .05 SPF!NGFIELD Job Number : 97 0325 a Page 2 FIXTURE I'NIT CALCULATION TABLE SPruNGFTEI.O, Number of New Fixture Unit Eguivalent Fixture UnitsFixture Tlpe Bathtub Drinking Fountain Floor Drain Interceptors For Grease/Oi1/Solids/etc Inteceptors For Sand/Auto Wash/Etc Laundry Tub/Clot.heswasher Clotheswasher - 3 Or More Receptor For Refrigerator/Water Station/fEc Receptor for Commercial Sink/Dishwasher/Etc Shower, Single Sta11 Shower, Gang Sink, Bar, Commercial, Residential Kitchen Urinal, Stall/WaII Wash Basin/Lavatory, Single Water Closet, Public fnstallation Water Closet, Private Miscellaneous TOTAL FIXTURE UNITS =23 CREDIT CALCTILATION TABLE: Based on assessed va1ue. If improvements occured after annexation date, credits are cal-culaLed separately (calculations are by $1000) Year Annexed: L979 Credit For ParceL Or Land Only If Appticable: 24,840 X 3.47 = 85.19 Improvement (if after annexation date): 0 X 3.47 = O.OO CREDIT TOTAIJ = 585.19 (If land value is multiplied by 1 then the parcel/Iand credit is not accurate.) 0 0 0 0 1 0 0 0 0 0 1 0 3 0 3 0 4 0 0 0 0 2 0 0 0 0 0 2 0 3 0 L2 0 1 2 3 6 6 1 3 z z 1 5 4 Willamalane PaiL & Recreation District Job. No. NAM SYSTEM DEVELOPMENT CHARGE WORKSHEET PHONE: srArE: UQ- rrr'ADDRESS: LOCATION OF P ED BUILDING SITE: Street Add Plat Name Tax Lot Number: 1. DEVELOpMENT TypE (Check appropriate dwelling(s). SDC calculations and dwelling t ype delinitions are on the back.) A. Singte-Family DetacheC t Single Family home Manufactured home not in a Park No. oF uNlrs { x $1,ooo Per unit = $.CD B. Single-Family Attached NO. OF UNITS X $924 per unit = $ C. Multi-Family Apartment NO. OF UNITS X $692 per unit = $ D. Manufactured Home Park NO. OF UNITS X $699 per unit = $ WILLAMALANE SDC tD p 2. SDC CREDIT (if applicable) SDO-payer must fumish proot of Willamalane Credit approval. See SDC Credit Worksheet. 3. TOTAL WILLAMALANE NET SDC ASSESSED (if SDC reduced for Credit) Deve nt Se L 00 I $ $ $ L, rufl ? City of Springfield s Department Date { r0 zzs FrFrE srREEr , . l-DC ELECTRT sPRTNGFTELD, oREGoN 97417 Z - ) rt -t.r) INSPECTION REQLIEST: 726-376{ ' -7" -r 1, Citv Jo OFFICE: 726-3159 ' .1 ; .N ll,\. -..3".' COHPI,ETU f'EE sf: GFteLo CAL PERHIT APPLICATION b Number a ZO 3 ZS: 1.ION OF LEGAI DESCRIPTION JOB DESCRI Permits are non-transferable and expire if vork is not started vi thin 1-80 days of issuance or if vork is suspended for 180 days. 2. CONTRACTOR INSTAILATTON ONLY Electrical Contractor Address ci ty- Phone Super:visor License Number Expiration Date Constr Contr. Number Expiration Date Signature of Supervising Electrician SCEEDULE BELOV Nev Residential-Single or Multi-Family per dvelling unit. Service Included: f tems Cos t 1000 sq.ft. or less Each additional 500 sq. ft or portion the reo f Each Manuf'd Home or Modular Dvelling SerVice or Feeder s 8s.00 s 1s.00 s 40.00 Services or Feeders Installation, Alterations or Relocation: A Sum B C 200 amps or less 201 amps to 400 amps -401 amps to 600 amps _601 amp-" to 1000 amps_ Over 1000 amps/volts Reconnect 0n1y 200 amps''or less ./ 201 amps to 400 amps -Over 401 to 600 amps -Over 600 amps or 1000-tofTs SUBTOTAL OF ABOVE 5Z State Surcharge 3Z Administrative Fee TOTAI s s s s /or s s0.00 s 60.00 s100.00 s130.00 s300.00 s 40.00 Temporary Services or Feeders Installation, Alteration or Relocation 40.00 55.00 80.00 Ovners Name Address Ci ty Phone L OVNER INSTALLATION The installation is being made on property I ovn vhich is not intended for saIe, Iease or rent. Ovners Signature: DATE: D. Branch Circuits Nev, Alteration or Extension Per Panel One Circuit $ 35.00 Each Addi tional Circuit or vith Service or Feeder Permit $ 2.00 E. MiscellaneouS (Service/feeder not included) -Each installation Pump or irrigation _ Sign/Out1ine Light ing_ Limited Energy/Res Limited Energy/Comm @ ee *Brt a6ove rc .fiora\ s 40.00 $ 40.00 $ 20.00 s 36.00 RECEIVED 5 /24-4e ) M.r r - L3 'g7 a41.25P Mor\--er Eng i neer i ng fuTORTIER F NGINEERING, P,C. PO. aOX !39 . r2as PEARL STBEET FUGENt . ()REGON 974'10 FHONE (561) 484-9080 ' FAx (54r) 484-6859 (- *1 )4A4-685e P^Orl March 13, 1997 Robert Coryell 2759 S, Cloverleaf Loop Springfield, OR97477 RE - w 0. #9797-PSB As ygu rqluesrsl, a ve.tical load analysis has been pertbrmed by L{ortier En$noering, P C t-cr the fbun<lation of the Robert Coryell two-story house project located st Lot #810 S. 44th Street. Spnngfield, Oregon I 5 " Spetxt Form with a 9" stem with #4 rebar 8t I 2" on oenter is needed for the tbundation stem wall . l?" X t2' X 12" footing with 2 - #4 rebar each way is needed at porch posts The post and beam pads ard the expanded footings as per plan are more than adequate to carry the vertical loads<_4X*a € I hope that rhis repofi is adequate for your needs and purposes at this time Thank you for this opportunity to be of service. If you have funher questions, please contact me at 484-9080 Very truly yours, Owen Grover, P E OLGib3r Bf,c(r dry\Pu'truYcll,Irb STFIUCTURAL BUILDING DFSIGN r rlRE PRO?Ff. r nr'J CoDE CoNSULTAI.JT . PLAN C}IECKIN(; CONSTRUCTION INSPEC'ii()N dr1<E Ls,L! I 0- S 44!h Stre .et$pringfield. OR F-<I]N,,-HEEL. ENTERI-,RI5E5:,-i('-| i,;.' iE, l -pr,i PHONE ND. : 541E,87657I3 FROI.4 UJ ,Prl.-_ia- L?LDG_5pfir,vR 5:.127;3 i 6a l'1ay. 3A 1t57 11:12RH P2 fr- I..Jto{PQUA BUILDING & HARDWARE tNC. Codvlac tlonu, Ccntat' 350 Oreenr,od Aw. 'Rtedrport, Orcgon 0?46? Phme (s41) a713538.WALL EOAEO .HOtrlt'l0 MATERIAL .ELECTHCAI. SUPFIESrBGK {ETTE.IT .MOULD|NOS .FEEHUI{G DooRS .FAINTS €LJq'S6 'TrcLs.WALLPAPEH +LOOfi@VEHING .TNUSSE$ MAY 30, tg97 T0 \fl.IOM !T Iy{AY CONCERN: t]lllPquA BLIILD{NG e HARDWARB, IOCATED.{T 5J0 GREENBTooD AvE, IN REEDSFoRT, oR. GuAnAl'irEEs rtIAT oLrR N{ANUrAcrr/'RED TRus.E wLL cARR.y rHE LoAD REeSTEED tvITH TI.61 .TDDITION AFTIT, STICXFRq,MIT{G ADDBD BY DAVE ABEL OF ABEL ENTERPRI'ES. TITANX \-OU. BD PRLSTDENT Eto \\ Atl KirEs cf l-.urnber & Plnrci o Hrtr& hdsfbl PtumbirE $rDpty F1tDt"] .. rriEEL ENIERF.T<I=E5(-- iF- r cc-.-., ,i' j6nl Ftcl":AEEL Ei$,URFfi: SES t-3il-rgS' 9j r5r.U PHDNE N[i. : 54168?€,5?r:- Fi.L^r, rit 'DCUa_tsL0G_HFDruR E3 I !71 3153 pHor.€ NT. : 5ar6g?65?6 F?CD,' r|.1P;U:-ELCG-HE!)UrR Sr ) Z;1 3.; ai? I'1aU. lE 1997 1l:I2Al1 Ff t' ,1ac. iB !!.9? trg: S:len p1 -,-::_ ',r:,- i r, ,. (,o,w. }.YA a 1rlurf ,,}.{rfi !:,,1 D+1H,1-e LS: i-7-: i i,f l, 11 1;.;;';. ?. 1 :i -,1 l-' v l: : r-', r.a a3tsry ;;;ir.; |- t- (1 :r_-:=,rli\.- T\t* I !,; I lF' llt Nrr _ l( .tt!-.(j -E I r';.-4 .. i.-,itri{F:7-tr- r.,,\-Lcr!r.\ ,x,l 5 :x{ tL:1t-a-1. 0B.a C-:1-9,6 r! I l- {.-I,8 ,r arl L, iil 1| ::-' .!!L; 3-'/ "-t,0-t rlt ! IL ,6! --rrdl lrDt r,,-, F:ECE I 1-3g_.r E.i) 0Lrr-6-rJ t3..9""CLr!B-:'-aI LttIl-7-13 tL:;-+.tE cr:3-I*9 LE: i{ PG'AA-- -; 'f Hr'.S&ti+;ilr-L ,i --.. _..GEtr---'t h.o, SfDEfD EP D-l- r' :----- i{rtCLi6-6{2 LS:d-}-r --.-:trar---'--1 i 6IIor.E E[ ,'!l-i !l-{.i.i-:-i i-!)5.' { i:rl ,'-f t o 't-t 4( L '1sn, rJe ijtt C,JA5 C-J-,' Sr,L/ 5 r/ t^:oc) 4I Coile- 4S frbou4- a\.1€4'< l/u ,fr d,L ,*J.'t. t r1.,','jl.,r1:J.JLj 1t,:,17 7b73tJEL,ERNIE R-htL Il'l5 & INSUI.ATION (541) 741_1478 \4, BFg II[, ,nc P,C_ 70061 F-ugene, Oli 92401 fAF: 72a-30AQ 'Lf tlo:u- rwej trs pr"+ +',SAYngcrYl €' Ca,t( dnd, ahou* ask fr Gann" Git(ard' 845 Sircllev SpringfietrJ , OR 97477 s.tel on-€* e et-kEr: /]{to,aa,t , *ob Barhear{, O,tf ,f SPr'yfietd re ' Ernie- R*r;/'ngs Harses Th* /rnt{r, ts {" infir'n Yo?r to insu tate the f{oorc a't *fro /- za-94 as t" u$*t )l/a*rie/ &as qsed fil/oary tra(dvseses: BtogL,l 863 rlqth fta,e f [oors uri+t. R- ZS Btz B25 3 H'J t! Streel 88r En*qq G insutoted aL( 4he;e u n1#"i f'berglass batfs ' 4 t{'e se P-J Bilt LlE. or eds jlea:e m1s"t[ ' ctTY oF sPnNcF,ELD, OREGOTV D EV ELOP M ENT S ERVICES DE PARTM E NT sPRrrsc*rELo Springfield Utility Board Lane Council of Governments 9l I Dispatch, Public Safety Lane County Elections Ddpartment Sanipac Rainbow Water District Springfi eld News/Register Guard 225 FIFTH STREET SPRINGFIELD, OR 97477 (541) 726-375s FAX (541) 726-368e May 28,1997 Professional Management Inc PO Box'938 Sherwood, Oregon 97140 RE: Address Verification Recently, it was brought to-our attention that your property located on Lot 89 of Lucem Meadows, also known as Lane County Reference Number 18020521, Tax Lot Number 032b0 was incorrectly addressed on the plans at the time of permit issuance. The correct. street address for this property is 8 l0 South 44th Place, Springfield, Oregon Because of the importance of sequential addresses in the City for the purposes of emergency services, we request that your reference to the property and the construction site address sign be changed immediately, I will be notifing the following agencies of this verification Springfield Police Department Springfield Fire Department U.S. Post Office U.S. West Communications Northwest Natural Gas TCI Cable United Parcel Service We sincerely apologize for any inconvenience this may cause. If I may be of further assistance, please feel free to phone me at726-3790. Sincerely, ,AqPP Lisa Hopper Building Safety Coordinator t Qrub'ra tg te ofbetveen the City of Springfi hereinafter called City, and the Applicant. rpor a 10 -6f IIe Sta ru tion ts r development CTTY OF SPRINGFIELD COHH1JNITY SERVICES DIVISION BUILDING SAFETY AUTHORTZATION TO PROCEED AGREEMENT THIS AGREEMENT is entered into this dav of ,%l*zZ e a mun by and 0regon, , hereinafter called I{HEREAS, the applicant has applied to the City Community Services BuildingDivision for issuance of certa improvements to be located at 0regon or vithin the City's Ur Assessor's Map and Tax Lot num 1n an ov ber ct o rea; Springfield, County I,,HEREAS, the applicant has asked the City to authorize the Applicant to immediately commence development improvements vithout a. completed plan reviev or subsequent approval as required by the Springfield Building Safety CodeAdministrative Code section 303(a). IIHEREAS, the Applicant has submitted to the City a completed permit application,3 (three) sets of construction dravings, specifications, and other data requiredfor the City to conplete the necessary plan reviev of the proposed development improvement. VHEREAS, the intendbd development improvement is of a nature that requires noother reviev approval from other State or local agencies and is exempt from thecriteria established by the Building Safety Division, attached as trxhibit A ofthis Agreement. IIHEREAS, the City has not revieved or approved the submitted materials for thedevelopment improvement, the City is thlrefore unable to confirm at this timevhether - the permi t applicat i r-.: submi t ted vilL be approve<i , and uhether the ;, NOIJ' THEREF0RE, in consideration of the foregoing recitals and of the mutual promises contained herein, the City authorizes immediate commencement of the development improvement specified in the permit application subject to thefolloving terms and conditions: UHEREAS, the applicant has requested the city to provide expedited authorizationto proceed vith.certain phases of construction prior to the completion of theCity's reviev of the permit applieation. VH.EREAS,.the gity's fee for the administrative services rendered in providing t expedited authorization is S150.00. ur Authorizat ion Page 2. to Proceed Agreement 1. City agrees that the Applicant may immediately commence vith the development improvements set forth in the permit application. City,sauthorization to proceed is conditione! hovever, upon Applicant's agreementthat the project vill be constructed as set forth in the attached submitted dravings and specifications, except as may be modified by city, and vilI comply vith all applicable lavs and ordinances. Applicant's innediate commencement of construction is at cant's ovn risk. The City nakes no assurance tt e t or construc on ts vill be rovedortuconstructontsvter 2. City agrees to reviev Applicant's. permit application in the normal revievprocess and to thereafter: a) issue Applieant the appropriate construction permits; or b) advise Applicant of deficiencies in the proposed construction vhich must be remedied before permits can be issued; or c) advise Applicant of any statutes, ordinances or code provisions vithvhich Applicant must comply vith before city can issue the permit. 3. Applicant agrees that if City finds Applicant's permit application andsubmitted materials inadequate or deficient in any manner intluding.but notlimited to' the application or the proposed construction do not comply vithall appricable statutes, ordinances or code provisions, Appricant viriexpeditiously-cure the deficiencies so that the City may ilsue the requiredpermits. Should Applicant fail to expeditiously correct- submitted materials,or should correc_tion prove impossible, City may in it,s discretion, take anyor all of the folloving actions. ' a) stop all further construction of the project in the manner prescribedi1 the Springfield Building Safety Code Administrarive Code (B3CAC), sECrroN 201 (d) b) order disconnection of serving utilities in a manner as prescribed inBSCAC, SECTT0N 201 (f) c) issue a NOTICE -!-i.) OIDER, for removal of e-lL such vo::I: in a manner as -lprescribed in BSCAC, SECTIoN 204. ABATEHEI{T OF L]NSAFE, SUBSTAI,IDARD 0R DANGEROUS BUILDINGS' STRUCTTiRES OR BUILDING SERVICE EQUIPMENT. Uponreceipt of such notice, Applicant sha1l immediately remove the vorkspecified in the Notice and Order. 4. Applicant agrees, if the issuance of the permit is denied: a) to remove, at the Appricant's sore cost and expense, ar1 compretedconstruction or improvements; and b) to restore the site or structure to it's pre-agreement condition andfree of all hazards Authorization Page 3. to Proceed Agreement 5. Applicant agrees that unticonstruction vi11 not to procby the City,s Building Ofiici cant's permit application is approved. ond the point of authorization approvedIicant's Point of Authorization is 1 Appli eed bey 6. Applicant agrees that aII vork perfor under this agreement shall beaccessible and ex posed for inspection purposes and that neither the Buildin 60fficial nor Ci ty shall be liable f,or the expense entailed in the removal o rreplacement of any material necessary to a11ov inspection. 7' Applicant agrees that_any or all'deficiencies identified during thenecessary inspections vi11 be promptly remedied, at apllic.nii" sole costand expense before.proceeding vith-any furthei construttion. Applicant a1-soagrees that these inspections do not replace the required plan reviev nor dothey imply any approval of the submittei materials.' B' Applicant agrees that no vork shall be done on any part of the buildingor structure beyond the point indicated in each su"clsiirre inspectionvithout first obtaining the approval of the Buirdi.e-oiil"i;i:'such approvalshall-be given only aftet an irrspection has been made of eaeh successivestep in the construction as inditated on the attached Exhibit B. ,t, this Agreementirty (30) days fromicant understands hout any notice frompermit is issued. 9. Notvithstanding any other provisions of this Agreemenshall terminate upon issuance of a building peimit or ththe date of this Agreenent, vhichever firsi i""ur". AppIthat arl vork on the project sharr immediaieiy-cease vit !l,g city if this-Agreeruent terminates before . buitairrgThis agreenent shall teruinate on t 10' Applicant agrees-to defend, indemnify and hold city harmless from anyand alr costs (including attorney fees),'liabirity or a;;;.;-of any kind ornature vhatsoever, for personal injury'and property damage arising "fro, in"-Applicant's early commencement of lonstruction and the vork undertaken orcomple ted . 11' The terms of th'is Agreement shall extend to and be binding upon theparties hereto and t:,eir heirs, successors and assigns -r-'- -: !2- +t any suit, action or other proceeding, or an appeal therefrom, isinstituted to obtain, establish,. Lnforce, 6i "o*per any right or obligationresulting from this Agreement, ih. p..r.iting-party sharl be entitred torecover from the adverse party, :,n iddition io'cosis and disbursements, suchadditional sums as the "ourts, both triai-.ni-rpp.l1ater may judge treasonable attorney fees. Authorization to Proceed Agreement Page 4 BEFoRESIGNINGTHISAGREE!.IENT,PI,EASEREADANDUNDERSTANDTIIE ,EANTNG otr eAcr pAR:AGRApE--&-lnrs aenesr{iNr. rn--AFFEcTS YouR TN:TERESTS rN TEE pRopERTy nr;' iN-txr-"iiNr-or'opralrJT', rf Pr'acEs YOU PERSONAI,I,Y AT RISK iiJ, TN" ,UU"-"*. PNOPENTY AT RISN OF roREcLosI,RE FoR cosTs d; - EiPiNSSS T-NC,RRSO BY .-TIIE CITY IN ENFORCING TIIE TER}IS OT TTi! AGREEI'IENT' -.TN-TES EVENT TEAT YOU DO NOr T,NDERSTAND ANY TERI{S 6N CONOTTIONS Oi-'TTTTS AGREEUENT' PI'EASE 'EEK ANY LEGai on oursrDE oprNroNs You IIAY DESTRE' CITY APPLICANT ContractorCity of SPringf ield Business N By Bui ing official Address CC Registration # I,AND/PROPERTY OWNER ( S I r/wE EAVE READ TIIE ABOVE AUtrIIORIZATION TO PROCEED AGREE!'TEIiIII ' UNDERSTA}ID WEA1T IT EXPRES SES A}ID TEE RES PONSIBILItrIES IT UPON US AS TEE I,AND/PROPERTY OWNERS r/wE AGREE trO BE BOI'ND lTERMS AND CONDIT IONS OT TEE Name 9?r{D Address VALIDATION: CITY JOB # RSCSTPT NUMB DATE PAID AIIOUNT RECEIV r/wE PIJACES BY ALI, \ RECEIVED BY ED a-= ErHrgll 4 Purpose The purpose of this agreement is to a11ov certain development im occur prior to obtaining plan reviev approval from the Springfie Services Division. provements to Id Communi ty Scope The use of this agreement shall be limited to certain one and tvo-familydvellings not complex in nature as determined by the Building Official and minor alterations or modifications to existing commereial and industrialbuildings vhich are of a non-structural'type and do not adversely affect anystructural member of the building or any part of the building having fireresistant construction. One and tvo-fanily dvelling plans for structures that are complex in nature that have been prepared by an Oregon licensed architect or engineer and accompanied. by a letter of reviev prepared by said architect or engineer, stating that 'the submitted material is in compliance vith the One and Tr.,o-Family Dvelling Specialty Code, may be considered eligible for this agreement. The folloving items include but are not Iimited to certain conditions of development identified as ineligible for this agreement: a) development requiring site approval vhich has not been obtained; b) nev development located on land vith over six-percent slope; c) Iots having expansive (c1ay) soil; d) development located vithin flood hazard areas; e) development located vithin vetland areas; f) pole buildings or other such type of structure that is not of conventional cons truct ion...\ To reguest an inspection, you must call 726-3769. This is a 24 hour recording. AII inspections reguested before 7:00 a.m. will be made the same working day, Inspectlons requested after ?:00 a.m. will be made the following work day. t--' Temporary Electric I f *rtk2*61E EXHIBIT B : Reguired Inspections Site - To be made after excavation, but prior to settingr forms - Footiag - After trenches are excavated a-/ Fouudation - After forms are erected but prior to concrete placement Underfloor Pluobiag - Prior to filling trench L-,- Uaderfloor Mecbaaical - Prior to lnsulation or decking -.,18- Post & BeaB - Prlbr to floor lnsulation or decking l-'-'-Underfloor Insulation - Prior to decking a)- Sanitary sewer - Prior to filling trench L.- Storu Sewer - Prlor to filling trench ,. ]l- water Line - Prior to filling trench